USER GUIDE | UG:311
QPI-x-EVAL1
QPI™ Series Active EMI Filters Evaluation Board
The QPI-x-EVAL1 (x refers to the specific QPI model) is an easy-to-use evaluation board for testing
the QPI family of active EMI filters. The board can be used in different EMI configurations
(see Figures 1 and 2), with many of the standard DC-DC converters available. Consult the converter
manufacturer’s recommendation for proper EMI re-circulation. The evaluation board includes a mounted
QPI filter, input and output capacitors, and terminals blocks for easy electrical connection.
When using the QPI-x-EVAL1 evaluation board, close attention must be paid to wiring and grounding.
Wires should be kept as short as possible and positioned to minimize radiated noise pick up around the
QPI filter. Refer to the Vicor QPI-AN1 application note for proper EMI measurement set up.
Filter performance in the application is highly dependent on several factors and cannot be extrapolated
from insertion loss curves alone. Final noise performance is a complex function of filter elements,
equipment grounding and noise source impedances, which vary in magnitude and phase over the
frequency spectrum of interest.
Designers should be aware that to select and quantify an EMI filter for conducted noise, they must test
the filter in their product under the set up and conditions specified in the applicable EMI standards.
Measurements should be made in consultation with in-house compliance testing or an independent
EMI test facility.
Check www.vicorpower.com for data sheets, application notes and additional product information.
Figure 1
Typical for “open-frame”
EMI topology
Input BUS
Converter
+
C1
QPI
CY
+
C2
–
DC-DC
–
CY
SHIELD
SHIELD
QPI-Active EVAL1
Figure 2
Typical for “baseplate”
EMI topology
Input BUS
Converter
+
C1
QPI
–
SHIELD Plane
+
C2
DC-DC
–
CY
SHIELD
CY
CY
CY
SHIELD
QPI-Active EVAL1
UG:311
Page 1
Figure 3
QPI-x-EVAL1 schematic
2
IN–
15
16
1
BUS–
BUS–
BUS–
1
5
Input BUS
Thermal
SHIELD
3
QPI+
QPI+
QPI+
9
8
7
QPI™
6
C1
47µF
SHIELD
J1
BUS+
BUS+
BUS+
Thermal
12
13
14
IN+
11
Thermal2
10
Thermal1
QPI–
QPI–
QPI–
4
3
2
OUT+
C2
47µF
OUT–
1
J2
2
3
Converter
SHIELD
Figure 4
QPI-x-EVAL1 board showing
location of components
and connectors
Ordering Information
Part Number
Description
QPI-3-EVAL1
Evaluation board for QPI-3LZ
QPI-4-EVAL1
Evaluation board for QPI-4LZ
QPI-5-EVAL1
Evaluation board for QPI-5LZ
QPI-6-EVAL1
Evaluation board for QPI-6LZ
UG:311
Page 2
Limitation of Warranties
Information in this document is believed to be accurate and reliable. HOWEVER, THIS INFORMATION
IS PROVIDED “AS IS” AND WITHOUT ANY WARRANTIES, EXPRESSED OR IMPLIED, AS TO THE
ACCURACY OR COMPLETENESS OF SUCH INFORMATION. VICOR SHALL HAVE NO LIABILITY FOR THE
CONSEQUENCES OF USE OF SUCH INFORMATION. IN NO EVENT SHALL VICOR BE LIABLE FOR ANY
INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT
LIMITATION, LOST PROFITS OR SAVINGS, BUSINESS INTERRUPTION, COSTS RELATED TO THE REMOVAL
OR REPLACEMENT OF ANY PRODUCTS OR REWORK CHARGES).
Vicor reserves the right to make changes to information published in this document, at any time
and without notice. You should verify that this document and information is current. This document
supersedes and replaces all prior versions of this publication.
All guidance and content herein are for illustrative purposes only. Vicor makes no representation or
warranty that the products and/or services described herein will be suitable for the specified use without
further testing or modification. You are responsible for the design and operation of your applications
and products using Vicor products, and Vicor accepts no liability for any assistance with applications or
customer product design. It is your sole responsibility to determine whether the Vicor product is suitable
and fit for your applications and products, and to implement adequate design, testing and operating
safeguards for your planned application(s) and use(s).
VICOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN LIFE SUPPORT,
LIFE-CRITICAL OR SAFETY-CRITICAL SYSTEMS OR EQUIPMENT. VICOR PRODUCTS ARE NOT CERTIFIED
TO MEET ISO 13485 FOR USE IN MEDICAL EQUIPMENT NOR ISO/TS16949 FOR USE IN AUTOMOTIVE
APPLICATIONS OR OTHER SIMILAR MEDICAL AND AUTOMOTIVE STANDARDS. VICOR DISCLAIMS
ANY AND ALL LIABILITY FOR INCLUSION AND/OR USE OF VICOR PRODUCTS IN SUCH EQUIPMENT OR
APPLICATIONS AND THEREFORE SUCH INCLUSION AND/OR USE IS AT YOUR OWN RISK.
Terms of Sale
The purchase and sale of Vicor products is subject to the Vicor Corporation Terms and Conditions of Sale
which are available at: (http://www.vicorpower.com/termsconditionswarranty)
Export Control
This document as well as the item(s) described herein may be subject to export control regulations.
Export may require a prior authorization from U.S. export authorities.
Contact Us: http://www.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
©2019 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
01/19
Rev 1.4
Page 3
很抱歉,暂时无法提供与“QPI-6-EVAL1”相匹配的价格&库存,您可以联系我们找货
免费人工找货