V110A24M300BN

V110A24M300BN

  • 厂商:

    VICOR(怀格)

  • 封装:

  • 描述:

    V110A24M300BN - 110V Input Maxi Family DC-DC Converter Module Features - Vicor Corporation

  • 详情介绍
  • 数据手册
  • 价格&库存
V110A24M300BN 数据手册
Data Sheet Features • DC input range: 66 – 154 V (continuous) • Encapsulated circuitry for shock and 110V Input Maxi Family DC-DC Converter Module vibration resistance • Extended temperature range • • • • • • • • • • • • (–55 to +100°C) Input surge withstand: 250 V for 100 ms DC output: 3.3 – 48 V Programmable output: 10 to 110% Regulation: ±0.2% no load to full load Efficiency: Up to 90% Maximum operating temp: 100°C, full load Power density: up to 80 W per cubic inch Height above board: 0.43 in. (10,9 mm) Parallelable, with N+M fault tolerance Low noise ZCS/ZVS architecture RoHS Compliant (with F or G pin option) Agency approvals Shown actual size: 4.6 x 2.2 x 0.5 in 117 x 56 x 12,7 mm Product Overview These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Absolute Maximum Ratings Parameter +In to –In voltage PC to –In voltage PR to –In voltage SC to –Out voltage –Sense to –Out voltage Isolation voltage in to out in to base out to base Operating Temperature Storage Temperature Pin soldering temperature Mounting torque Rating –0.5 to +260 –0.5 to +7.0 –0.5 to +7.0 –0.5 to +1.5 1.0 3000 1500 500 –55 to +100 –65 to +125 500 (260) 750 (390) 5 (0.57) Unit Vdc Vdc Vdc Vdc Vdc Vrms Vrms Vrms °C °C °F (°C) °F (°C) in-lbs (N-m) Test voltage Test voltage Test voltage M-Grade M-Grade < 5 sec; wave solder < 7 sec; hand solder 6 each Notes Applications Railway/Transportation system applications including communications systems, information display, lighting, control systems, ticket machines, passenger entertainment, public address systems, door control, industrial power systems and power generation systems. Part Numbering e.g. V110A24C400BL V110A B Output Voltage 3 V 3 = 3.3 V 5 = 5V 8 = 8V 12 = 12 V 15 = 15 V 24 = 24 V 28 = 28 V 36 = 36 V 48 = 48 V Product Grade Temperatures (°C) Grade Operating Storage E = -10 to +100 - 20 to +125 C = - 20 to +100 - 40 to +125 T = - 40 to +100 - 40 to +125 H = - 40 to +100 - 55 to +125 M = - 55 to +100 - 65 to +125 VOUT 3.3 V 5V 8V 12 V 15 V 24 V 28 V 36 V 48 V Output Power POUT 150 W, 200 W 200 W, 300 W 200 W, 300 W 300 W, 400 W 300 W, 400 W 300 W, 400 W 300 W, 400 W 300 W, 400 W 300 W, 400 W Pin Style Blank: Short Tin/Lead L: Long Tin/Lead S: Short ModuMate N: Long ModuMate F: Short RoHS G: Long RoHS Baseplate Blank: Slotted 2: Threaded 3: Through-hole For a description of pin options, see page 11. Baseplate options include slotted flanges, threaded and through-hole. See page 12 for dimensions. For other package sizes and power levels, see the Mini (half size) and Micro (quarter size) datasheets. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 110V Maxi Family Rev. 2.1 Page 1 of 13 Set your site on VICOR at vicorpower.com MODULE FAMILY ELECTRICAL CHARACTERISTICS Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. MODULE INPUT SPECIFICATIONS Parameter Operating input voltage Input surge withstand Undervoltage turn-on Undervoltage turn-off Overvoltage turn-off/on Disabled input current 54 155.5 64 56 161.7 169.4 1.3 Min 66 Typ 110 Max 154 250 65.4 Unit Vdc Vdc Vdc Vdc Vdc mA PC pin low Notes EN50155 30 Ω, < 30 pF PC current = 1.0 mA PC voltage = 5.5 V Must be able to sink ≥4 mA. See Fig. 1 MODULE GENERAL SPECIFICATIONS Parameter Remote sense (total drop) Isolation test voltage in to out in to base out to base Isolation resistance (in to out) Weight Temperature limiting Agency approvals 7.4 (209.3) 100 3000 1500 500 10 8.2 (232.5) 115 cURus, TÜV, CE 9.0 (255.7) Min Typ Max 0.5 Unit Vdc Vrms Vrms Vrms MΩ ounces (grams) °C See Figs. 2 and 4 UL60950-1, EN60950-1, CSA60950-1, IEC60950-1. With appropriate fuse in series with the +Input Notes 0.25 V per leg (senses must be closed) Complies with reinforced insulation requirements Complies with basic insulation requirements Complies with operational insulation requirements Note: Specifications are subject to change without notice. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 110V Maxi Family Rev. 2.1 Page 3 of 13 Set your site on VICOR at vicorpower.com MODULE SPECIFIC OPERATING SPECIFICATIONS 3.3 Vout, 200 W (e.g. V110A3V3C200BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 79 4.14 Typ 81 90 4.3 6.1 ±0.02 69.7 69.7 Max 113 4.46 8.2 ±0.2 60.6 81.9 81.9 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage
V110A24M300BN
1. 物料型号: - 例如:V110A24C400BL,表示110V Maxi Family系列的DC-DC转换模块。

2. 器件简介: - 这些DC-DC转换模块采用先进的电源处理、控制和封装技术,提供性能、灵活性、可靠性和成本效益的成熟电源组件。高频ZCS/ZVS开关提供了高功率密度、低噪声和高效率。

3. 引脚分配: - +In(+输入):1号引脚 - Primary Control(PC,主控):2号引脚 - Parallel(PR,并行):3号引脚 - -In(-输入):4号引脚 - -Out(-输出):5号引脚 - -Sense(-感测):6号引脚 - Secondary Control(SC,次控):7号引脚 - +Sense(+感测):8号引脚 - +Out(+输出):9号引脚

4. 参数特性: - 输入电压范围:66 – 154 V - 输出电压可调:3.3 – 48 V - 效率高达90% - 功率密度:每立方英寸高达80瓦 - 工作温度范围:-55至+100°C

5. 功能详解: - 这些模块能够在输入电压、输出负载和基板温度的全操作范围内工作。它们支持通过固定电阻、电位计或电压DAC进行输出电压编程,并且支持并行操作以增加功率和实现N+1(N+M)冗余和相控阵能力。

6. 应用信息: - 适用于铁路/交通系统应用,包括通信系统、信息显示、照明、控制系统、售票机、乘客娱乐、公共广播系统、门控、工业电源系统和发电系统。

7. 封装信息: - 封装细节包括模块外形、PCB安装规格和基板选项,例如带槽法兰、螺纹和通孔。有关其他封装尺寸和功率级别的信息,请参阅Mini(半尺寸)和Micro(四分之一尺寸)数据手册。
V110A24M300BN 价格&库存

很抱歉,暂时无法提供与“V110A24M300BN”相匹配的价格&库存,您可以联系我们找货

免费人工找货