V48B12T250BF2

V48B12T250BF2

  • 厂商:

    VICOR(怀格)

  • 封装:

    -

  • 描述:

    CONVERTERMODDC/DC12V250W

  • 详情介绍
  • 数据手册
  • 价格&库存
V48B12T250BF2 数据手册
Data Sheet 48V Input Mini Family DC-DC Converter Module Features • • • • • • • • • • • • RoHS Compliant (with F or G pin option) DC input range: 36 - 75 V Input surge withstand: 100 V for 100 ms DC output: 2 – 48 V Programmable output: 10 to 110% Regulation: ±0.2% no load to full load Efficiency: Up to 89% Maximum operating temp: 100°C, full load Power density: up to 100 W per cubic inch Height above board: 0.43 in. (10,9 mm) Parallelable, with N+M fault tolerance Low noise ZCS/ZVS architecture Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Overview These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Absolute Maximum Ratings Parameter +In to –In voltage PC to –In voltage PR to –In voltage SC to –Out voltage –Sense to –Out voltage Isolation voltage in to out in to base out to base Operating Temperature Storage Temperature Pin soldering temperature Rating -0.5 to +105 -0.5 to +7.0 -0.5 to +7.0 -0.5 to +1.5 1.0 3000 1500 500 -55 to +100 -65 to +125 500 (260) 750 (390) 5 (0.57) Unit Vdc Vdc Vdc Vdc Vdc Vrms Vrms Vrms °C °C °F (°C) °F (°C) in-lbs (N-m) Test voltage Test voltage Test voltage M-Grade M-Grade 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 46.4 31.8 5 Vout, 200 W (e.g. V48B5C200BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 84 6.03 Typ 85 73 6.25 4 ±0.02 46 46 Max 92 6.47 6 ±0.2 40 52 56 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 40.8 28 12 Vout, 250 W (e.g. V48B12C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 86 13.7 Typ 87 378 14.3 4.4 ±0.02 24 24 Max 473 14.9 6.5 ±0.2 20.83 27.2 26.2 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 21.3 14.6 15 Vout, 250 W (e.g. V48B15C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 87.5 17.1 Typ 88.5 160 17.8 5.3 ±0.02 19.2 19.2 Max 200 18.5 7.9 ±0.2 16.67 21.8 21.8 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 17 11.6 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 48V Mini Family Rev. 7.4 Page 4 of 11 Set your site on VICOR at vicorpower.com MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT) 24 Vout, 250 W (e.g. V48B24C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 88 27.1 Typ 89 220 28.1 5 ±0.02 12.1 12.1 Max 275 29.1 7.5 ±0.2 10.42 13.7 13.7 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 10.7 7.35 28 Vout, 250 W (e.g. V48B28C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 88.5 31.5 Typ 89.5 178 32.7 5.8 ±0.02 10.3 10.3 Max 223 33.9 8.7 ±0.2 8.93 12.1 12.1 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 9.1 5 36 Vout, 250 W (e.g. V48B36C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 88.5 40.4 Typ 89.3 250 41.9 6.9 ±0.02 7.98 7.98 Max 313 43.4 11.1 ±0.2 6.94 9.37 9.37 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 5.31 2.08 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 48V Mini Family Rev. 7.4 Page 5 of 11 Set your site on VICOR at vicorpower.com CONTROL FUNCTIONS - PC PIN Module Enable/Disable The module may be disabled by pulling PC below 2.3 V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either directly or via “OR’ing” diodes. See Figure 1. Primary Auxiliary Supply At 5.7 V, PC can source up to 1.5 mA. In the example shown in Figure 3, PC powers a module enabled LED. Module Alarm The module contains “watchdog” circuitry which monitors input voltage, operating temperature and internal operating parameters. In the event that any of these parameters are outside of their allowable operating range, the module will shut down and PC will go low. PC will periodically go high and the module will check to see if the fault (as an example, overtemperature) has cleared. If the fault has not been cleared, PC will go low again and the cycle will restart. The SC pin will go low in the event of a fault and return to its normal state after the fault has been cleared. See Figures 2 and 4. +In PC +Out +S SC –S +IN SW1 Auto Restart 2-20 ms typ. f (VIN) Input Undervoltage Input Overvoltage (See Note 1) Overtemperature Module Faults 50 Ω SW2 SW3 1K +OUT +S SC –S PC SW1, 2, & 3 shown in "Fault" position PR –IN 1M Disable PR –In 5.7 Vdc (0-3 mA) –Out 1 Not applicable for 300 Vdc input family 1.23 Vdc 6K – OUT Disable = PC
V48B12T250BF2
物料型号: - 型号示例:V48B12T250BL2,表示48V输入,12V输出,250W输出功率。

器件简介: - VICOR迷你家族DC-DC转换模块采用先进的功率处理、控制和封装技术,提供高性能、灵活性、可靠性和成本效益的成熟电源组件。高频ZCS/ZVS开关提供高功率密度、低噪声和高效率。

引脚分配: - PC引脚:模块使能/失能控制。 - PR引脚:并联操作和电流共享。 - SC引脚:输出电压编程和远程感应。

参数特性: - 输入电压范围:36Vdc至75Vdc。 - 输出电压:2V至48V,可编程输出10%至110%。 - 调节:±0.2%无负载至满载。 - 效率:最高可达89%。 - 最大工作温度:100°C(满载)。 - 功率密度:每立方英寸高达100W。 - 板高:0.43英寸(10.9毫米)。

功能详解: - 并行操作:支持N+1(N+M)冗余和相控阵能力。 - 高频ZCS/ZVS架构:低噪声、高效率。 - 多种封装和功率等级:提供微型(四分之一尺寸)和最大(全尺寸)数据表。

应用信息: - 分布式电源、医疗、自动测试设备(ATE)、通信、国防、航空航天。

封装信息: - 物理尺寸:2.28 x 2.2 x 0.5英寸(57.9 x 55.9 x 12.7毫米)。 - 安装扭矩:5英寸磅(0.57牛顿米)。 - 引脚风格:包括短引脚/长引脚、ModuMate、RoHS合规等选项。
V48B12T250BF2 价格&库存

很抱歉,暂时无法提供与“V48B12T250BF2”相匹配的价格&库存,您可以联系我们找货

免费人工找货