V48B24T250BL3

V48B24T250BL3

  • 厂商:

    VICOR(怀格)

  • 封装:

    POWER-MODULE

  • 描述:

    CONVERTER MOD DC/DC 24V 250W

  • 详情介绍
  • 数据手册
  • 价格&库存
V48B24T250BL3 数据手册
Data Sheet 48V Input Mini Family DC-DC Converter Module Features • • • • • • • • • • • • RoHS Compliant (with F or G pin option) DC input range: 36 - 75 V Input surge withstand: 100 V for 100 ms DC output: 2 – 48 V Programmable output: 10 to 110% Regulation: ±0.2% no load to full load Efficiency: Up to 89% Maximum operating temp: 100°C, full load Power density: up to 100 W per cubic inch Height above board: 0.43 in. (10,9 mm) Parallelable, with N+M fault tolerance Low noise ZCS/ZVS architecture Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Overview These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Absolute Maximum Ratings Parameter +In to –In voltage PC to –In voltage PR to –In voltage SC to –Out voltage –Sense to –Out voltage Isolation voltage in to out in to base out to base Operating Temperature Storage Temperature Pin soldering temperature Rating -0.5 to +105 -0.5 to +7.0 -0.5 to +7.0 -0.5 to +1.5 1.0 3000 1500 500 -55 to +100 -65 to +125 500 (260) 750 (390) 5 (0.57) Unit Vdc Vdc Vdc Vdc Vdc Vrms Vrms Vrms °C °C °F (°C) °F (°C) in-lbs (N-m) Test voltage Test voltage Test voltage M-Grade M-Grade 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 46.4 31.8 5 Vout, 200 W (e.g. V48B5C200BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 84 6.03 Typ 85 73 6.25 4 ±0.02 46 46 Max 92 6.47 6 ±0.2 40 52 56 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 40.8 28 12 Vout, 250 W (e.g. V48B12C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 86 13.7 Typ 87 378 14.3 4.4 ±0.02 24 24 Max 473 14.9 6.5 ±0.2 20.83 27.2 26.2 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 21.3 14.6 15 Vout, 250 W (e.g. V48B15C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 87.5 17.1 Typ 88.5 160 17.8 5.3 ±0.02 19.2 19.2 Max 200 18.5 7.9 ±0.2 16.67 21.8 21.8 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 17 11.6 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 48V Mini Family Rev. 7.4 Page 4 of 11 Set your site on VICOR at vicorpower.com MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT) 24 Vout, 250 W (e.g. V48B24C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 88 27.1 Typ 89 220 28.1 5 ±0.02 12.1 12.1 Max 275 29.1 7.5 ±0.2 10.42 13.7 13.7 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 10.7 7.35 28 Vout, 250 W (e.g. V48B28C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 88.5 31.5 Typ 89.5 178 32.7 5.8 ±0.02 10.3 10.3 Max 223 33.9 8.7 ±0.2 8.93 12.1 12.1 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 9.1 5 36 Vout, 250 W (e.g. V48B36C250BL) Parameter Efficiency Ripple and noise Output OVP setpoint Dissipation, standby Load regulation Load current Current limit Short circuit current Min 88.5 40.4 Typ 89.3 250 41.9 6.9 ±0.02 7.98 7.98 Max 313 43.4 11.1 ±0.2 6.94 9.37 9.37 Unit % mV Volts Watts % Amps Amps Amps Notes Nominal input; full load; 25°C p-p; Nominal input; full load; 20 MHz bandwith 25°C; recycle input voltage to restart (>100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage 100 ms off) No load No load to full load; nominal input Output voltage 95% of nominal Output voltage < 250 mV 0 5.31 2.08 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 48V Mini Family Rev. 7.4 Page 5 of 11 Set your site on VICOR at vicorpower.com CONTROL FUNCTIONS - PC PIN Module Enable/Disable The module may be disabled by pulling PC below 2.3 V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either directly or via “OR’ing” diodes. See Figure 1. Primary Auxiliary Supply At 5.7 V, PC can source up to 1.5 mA. In the example shown in Figure 3, PC powers a module enabled LED. Module Alarm The module contains “watchdog” circuitry which monitors input voltage, operating temperature and internal operating parameters. In the event that any of these parameters are outside of their allowable operating range, the module will shut down and PC will go low. PC will periodically go high and the module will check to see if the fault (as an example, overtemperature) has cleared. If the fault has not been cleared, PC will go low again and the cycle will restart. The SC pin will go low in the event of a fault and return to its normal state after the fault has been cleared. See Figures 2 and 4. +In PC +Out +S SC –S +IN SW1 Auto Restart 2-20 ms typ. f (VIN) Input Undervoltage Input Overvoltage (See Note 1) Overtemperature Module Faults 50 Ω SW2 SW3 1K +OUT +S SC –S PC SW1, 2, & 3 shown in "Fault" position PR –IN 1M Disable PR –In 5.7 Vdc (0-3 mA) –Out 1 Not applicable for 300 Vdc input family 1.23 Vdc 6K – OUT Disable = PC
V48B24T250BL3
1. 物料型号: - 例如:V48B12T250BL2,表示48V输入,12V输出,250W输出功率的型号。

2. 器件简介: - 该DC-DC转换模块使用先进的电源处理、控制和封装技术,提供高性能、灵活性、可靠性和成本效益的成熟电源组件。高频ZCS/ZVS开关提供高功率密度、低噪声和高效率。

3. 引脚分配: - 文档中提到了PC、PR和SC三个引脚的功能,包括模块使能/禁用、输出电压编程和并行操作等。

4. 参数特性: - 输入电压范围:36V至75V。 - 输出电压:2V至48V,可编程输出10%至110%。 - 调节率:±0.2%(无负载至全负载)。 - 效率:高达89%。 - 最高工作温度:100°C(全负载)。 - 功率密度:高达100W每立方英寸。 - 板高:0.43英寸(10.9毫米)。

5. 功能详解: - 模块包含“看门狗”电路,监控输入电压、工作温度和内部运行参数。如果这些参数超出允许范围,模块将关闭,PC引脚将变为低电平。 - 输出电压可通过固定电阻、电位器或电压DAC进行调整或编程。

6. 应用信息: - 分布式电源、医疗、自动测试设备(ATE)、通信、国防、航空。

7. 封装信息: - 物理尺寸为2.28 x 2.2 x 0.5英寸(57.9 x 55.9 x 12.7毫米)。 - 底板选项包括开槽法兰、螺纹和通孔。其他封装尺寸和功率级别的数据表可参见Micro(四分之一尺寸)和Maxi(全尺寸)数据表。
V48B24T250BL3 价格&库存

很抱歉,暂时无法提供与“V48B24T250BL3”相匹配的价格&库存,您可以联系我们找货

免费人工找货