12 1-800-735-6200
VI-200
DC-DC Converters 50 to 200 Watts
Features
s Up to 50W/Cubic Inch s UL, CSA, TÜV, VDE, BABT, AUSTEL s Up to 90% Efficiency s Size: 4.6" x 2.4" x 0.5" (116,8 x 61,0 x 12,7) s Remote Sense and Current Limit s OVP, Thermal Shutdown s Logic Disable s Wide Range Output Adjust s Compatible Power Booster Modules s ZCS Power Architecture s Low Noise FM Control s CE Marked Nominal
0 1 W 2 3 N 4 T 5 6 7 = 12V = 24V = 24V = 36V = 48V = 48V = 72V = 110V = 150V = 300V = 150/300V
Rev 3 1 of 2
Converter Selection Chart
VI-2
Input Voltage Range Brownout /Transient*
10 21 18 21 42 36 55 66 100 200 100 20V 32V 36V 56V 60V 76V 100V 160V 200V 400V 375V (1) (4) (2) (3) (4) (4) (4) (2) (5) (4) (6) n/a 18V n/a 18V 36V n/a 45V n/a 85V 170V 90V 22V 36V n/a 60V 72V n/a 110V n/a 215V 425V n/a
Output Voltage
Z= 2V Y = 3.3V 0= 5V X = 5.2V W = 5.5V V = 5.8V T = 6.5V R = 7.5V M = 10V 1 = 12V P = 13.8V 2 N 3 L J K 4 H F D B = 15V = 18.5V = 24V = 28V = 36V = 40V = 48V = 52V = 72V = 85V = 95V
Product Grade/ Product Grade/ Operating Temp. Storage Temp.
E= C= I= M= -10°C to -25°C to -40°C to -55°C to +85°C +85°C +85°C +85°C E C I M = = = = -20°C to +100°C -40°C to +100°C -55°C to +100°C -65°C to +100°C
Output Power/Current
VOUT ≥ 5V Y = 50W X = 75W W = 100W V = 150W U = 200W Y X W V U VOUT < 5V = 10A = 15A = 20A = 30A = 40A
Product Highlights
The VI-200 Family, with over 8 million shipped, is Vicor’s first generation of “zero-current-switching” component-level DC-DC converters. Operating at frequencies up to 2 MHz, VI-200 Family Converters offer exceptional power density, efficiency, noise performance, reliability and ease of use. Power Boosters provide a simple, cost effective, off-the-shelf solution for higher power output requirements. One or more boosters may be used to create synchronous arrays capable of supplying several kilowatts of output power. The flexibility of Vicor’s power components is also available in half-size, half-power VI-J00 MiniMods. (pg. 72)
Overtemperature shutdown 95°C typical (recycle power to restart).
Max. Output For (1) (2) (3) 5V Outputs 75W 150W 100W > 5V Outputs 75W 150W 100W < 5V Outputs 15A 30A 20A
For additional output power use “Boosters”. Change (VI-2xx-xx) to (VI-Bxx-xx).
Max. Output For (4) (5) (6) 5V Outputs 200W 150W 75W > 5V Outputs 200W 200W 100W < 5V Outputs 40A 40A 20A
* Brownout 75% of rated load; transient voltage for 1 second.
Mechanical Drawing
.50 (12,7)
.30±.015 (7,6)±(0,38)
1.80 (45,7)
4.60 (116,8) 3.60 (91,4)
.080 (2,0) Dia (2) places Solder plate over copper alloy
4 2.10 (53,3) 3
9
Packaging Options
SlimMods™, high power density, flangeless packages and FinMods™, featuring integral finned heatsinks. SlimMod: Option suffix: - S Example: VI - 2XX - XX - S FinMod: Option suffix: - F1 and - F2 Examples: VI - 2XX - XX -F1, 0.75" height VI - 2XX - XX -F2, 1.00" height
VI-200
2 1
8 7 6 5
1.40 1.00 (35,6) .70 (25,4) .40 (17,8) (10,2) .35±.015 (8,9)±(0,38)
Pin # 1 2 3 4 5 6* 7* 8* 9
Function +In Gate In Gate Out -In +Out +Sense Trim -Sense -Out
.15 (3,8)
FULL R .15 (3,8) Product ID this surface
.040 (1,0) Dia (7) places Solder plate over copper alloy
* Do not connect on Booster modules
2.40 (61,0) 4.20 (106,7) .22 (5,6) MIN .30 (7,6) Min 1.75 (44,5)
.50 (12,7) .12 (3,0)
+.030 (0,76) -.000 (0)
.01 Aluminum Base
70
For the latest Vicor Product Information: www.vicorpower.com
12 1-800-735-6200
Converter Specifications
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
VI-200 E-Grade PARAMETER
s Input Characteristics Inrush charge Input reflected ripple current – pp Input ripple rejection
Rev 3 2 of 2
VI-200 C-, I-, M-Grade MIN. TYP. MAX. UNITS TEST CONDITIONS
MIN.
TYP.
MAX.
120x10 -6 10% 25+20Log Vin Vout
()
2
120x10 -6 200x10-6 10% 30+20Log Vin Vout 20+20Log Vin Vout
Coulombs IIN dB dB Watts
Nominal line Nominal line, full load 120 Hz, nominal line 2400 Hz, nominal line
() ()
No load power dissipation s Output Characteristics Setpoint accuracy Load/line regulation Load/line regulation Output temperature drift Long term drift Output ripple - pp: 2V, 3.3V 5V 10-48V Trim range1 Total remote sense compensation OVP set point Current limit Short circuit current 3 s Control Pin Characteristics Gate out impedance Gate in impedance Gate in open circuit voltage Gate in low threshold Gate in low current Power sharing accuracy s Dielectric Withstand Characteristics Input to output Output to baseplate Input to baseplate s Thermal Characteristics Efficiency Baseplate to sink Thermal shutdown4 (Drivers only) s Mechanical Specifications Weight
1 2
1.35
1.35
2
1%
2% 0.5% 1%
0.02 0.02 150 mV 5% 3% 110% 125%2 105% 20% 135% 140%
0.5% 0.05% 0.2% 0.01 0.02 60 mV 2% 0.75% 50% 0.5 115% 105% 20%
1% 0.2% 0.5% 0.02
VNOM VNOM VNOM % / °C %/1K hours
LL to HL, 10% to Full Load LL to HL, No Load to 10% Over rated temp.
50% 0.5
100 mV 3% 1.5% 110% 135% 125% 130% Volts VNOM INOM INOM
20 MHz bandwidth 20 MHz bandwidth 20 MHz bandwidth 0.25V max. neg. leg Recycle power Automatic restart
125%2
50 10 3 6 0.65 0.95 6 1.05 0.65 0.95
50 10 3 6 6 1.05
Ohms Ohms Volts Volts mA
Use open collector
3,000 500 1,500
3,000 500 1,500
VRMS VRMS VRMS
Baseplate earthed
90
78-88% 0.2 95
105
90
80-90% 0.2 95
105
°C/Watt °C
With Vicor P/N 01777 Cool and recycle power to restart
6.0 (170)
6.0 (170)
Ounces (Grams)
10V, 12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range. 131% nominal for booster modules. 3 Output voltages of 3.3V or 5V incorporate foldback current limiting; all other outputs provide constant current limiting. 4 No overtemp protection in booster modules.
For the latest Vicor Product Information: www.vicorpower.com
71