0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VI-2T1-CV-B1

VI-2T1-CV-B1

  • 厂商:

    VICOR(威科)

  • 封装:

    POWER-MODULE-9P_116.8X61MM_TM

  • 描述:

    DC DC CONVERTER 12V 150W

  • 详情介绍
  • 数据手册
  • 价格&库存
VI-2T1-CV-B1 数据手册
DC-DC Converters VI-200 VE-200 ® S US C C NRTL US 50 to 200 Watts Features & Benefits Product Highlights • Isolated output The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of “zero-current-switching” component-level DC-DC converters. • Up to 50W/in3 Operating at frequencies up to 2MHz, VI-200 family converters offer exceptional power density, efficiency, noise performance, reliability and ease of use. Booster modules (VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output requirements. One or more boosters may be used to create synchronous arrays capable of supplying several kilowatts of output power. • cURus, cTÜVus • Up to 90% efficiency • Size: 4.6” x 2.4” x 0.5” (116,8 x 61,0 x 12,7mm) • Remote sense and current limit The flexibility of Vicor’s power components is also available in half-size, half-power VI-J00 MiniMods. • OVP, thermal shutdown • Logic disable • Wide range output adjust • Compatible power booster modules • ZCS power architecture • Low noise FM control • CE Marked • RoHS compliant (VE-200) Part Numbering VI — 2 6 1 — C W Family Series Input Output Grade Power VI = Non-RoHS 2 = 200 0 = 12V N = 48V Z = 2V M = 10V K = 40V E = –10 to 85°C ≥ 5V < 5V VE = RoHS B = Booster V = 24V 4 = 72V Y = 3.3V 1 = 12V 4 = 48V C = –25 to 85°C U = 200W U = 40A 1 = 24V T = 110V 0 = 5V P = 13.8V H = 52V I = – 40 to 85°C V = 150W V = 30A Note: For additional packaging options, please see page 5. W = 24V 5 = 150V X = 5.2V 2 = 15V F = 72V M = –55 to 85°C W = 100W W = 20A 2 = 36V 6 = 300 V W = 5.5V N = 18.5V D = 85V X = 75W X = 15A 3 = 48V 7 = 150/300V V = 5.8V 3 = 24V B = 95V Y = 50W Y = 10A T = 6.5V L = 28V R = 7.5V J = 36V VI-200 DC-DC Converters Page 1 of 7 Rev 3.9 08/2017 VI-200, VE-200 Maximum Power Available for VI-2xx-xx [a] Input 3.3 5 5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95 [b] 2 Transient VOUT Designators VIN Designators Voltage Nom. (Range) Low Line 75% Max Power Output Z Y 0 X W V T R M 1 P 2 N 3 L J K 4 H F D B 12 (10 – 20) n/a 22 0 X X X X X X X X X X X X X X X X X X X X X X 24 (10 – 36) n/a n/a V -- X Y Y Y Y Y X X X X X X X X X X X -- -- -- -- 24 (21 – 32) 18 36 1 U U U U U U V V U U U U U U U U U U U U U U 24 (18 – 36) n/a n/a W V V V V V V W W V V V V V V V V V V V V V V 36 (21 – 56) 18 60 2 W V W W W W W W W W W W W W W W W W W -- -- -- 48 (42 – 60) 36 72 3 U U U U U U U U U U U U U U U U U U U U U U 48 (36 – 76) n/a n/a N U U U U U U U U U U U U U U U U U U U U U U 72 (55 – 100) 45 110 4 v U U U U U V V U U U U U U U U U U U U U U 110 (66 – 160) n/a n/a T V V V V V V W W V V V V V V V V V V V V -- -- 215 5 U U V V V V V V U U U U U U U U U U U U U U n/a 7 W W Y Y Y Y W W W W W W W W W W W W W -- -- -- 425 6 U U U U U U V V U U U U U U U U U U U U U U 150 (100 – 200) 150 (100 – 375) 300 (200 – 400) 85 [c] n/a 170 [d] [a] For additional output power, “booster” modules are available. (VI-Bxx-xx). Transient voltage for 1 second. [c] 12V OUT, 13.8VOUT, 15VOUT, 200W models are limited to 90VDC. [d] 15V OUT, 200W models are limited to 185VDC. [b] Converter Specifications (Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.) Input Specifications VI-200 E-Grade Parameter Min Inrush charge Input reflected ripple current – pp Input ripple rejection Typ VI-200 C-, I-, M-Grade Max Min 120 x 10-6 10% 25+20 Log Max Units 120 x 10-6 200 x 10-6 Coulombs Nominal line IIN Nominal line, full load dB 120Hz, nominal line dB 2400Hz, nominal line 10% (VV ) (VV ) V 20+20 Log ( V ) IN 30+20 Log OUT IN OUT IN OUT No load power dissipation VI-200 DC-DC Converters Page 2 of 7 1.35 2 1.35 Rev 3.9 08/2017 Test Conditions Typ 2 Watts VI-200, VE-200 Converter Specifications (Cont.) (Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.) Output Characteristics VI-200 E-Grade Parameter Min Setpoint accuracy VI-200 C-, I-, M-Grade Typ Max 1% Min Typ Max Units Test Conditions 2% 0.5% 1% VNOM Load/line regulation 0.5% 0.05% 0.2% VNOM LL to HL, 10% to Full Load Load/line regulation 1% 0.2% 0.5% VNOM LL to HL, No Load to 10% 0.02 % / °C Over rated temp. Output temperature drift 0.02 0.01 Long term drift 0.02 0.02 %/1K hours Output ripple – pp: 2V, 3.3V 150 60 100 mV 20MHz bandwidth 5V 5% 2% 3% VNOM 20MHz bandwidth 10 – 95V 3% 0.75% 1.5% VNOM 20MHz bandwidth 110% VNOM Trim range [a] Total remote sense compensation 50% 110% 0.5 OVP set point 50% Volts 0.25V max. neg. leg 135% VNOM Recycle power 0.5 125% [b] 115% 125% [b] Current limit 105% 135% 105% 125% IFULL LOAD Automatic restart Short circuit current [c] 20% 140% 20% 130% IFULL LOAD Automatic restart [a] 10V to 15V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range. 3.3V output trim range 2.20 to 3.63V, 95V output –50 + 0% trim range. [b] 131% nominal for booster modules. [c] Output voltages of 3.3V or 5V incorporate foldback current limiting; For output voltages from 5.2V to 7.5V consult factory; All other outputs provide constant current limiting. Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information, please refer to output connections on page 5. Control Pin Specifications VI-200 E-Grade Parameter Min Gate out impedance Gate in impedance Gate in open circuit voltage Gate in low threshold Max Min VI-200 DC-DC Converters Page 3 of 7 Max Units 50 Ohms 1000 1000 Ohms 6 6 Volts 0.65 6 0.95 Typ 50 0.65 Gate in low current Power sharing accuracy Typ VI-200 C-, I-, M-Grade 1.05 Volts 6 0.95 Rev 3.9 08/2017 1.05 mA Test Conditions Use open collector VI-200, VE-200 Converter Specifications (Cont.) (Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.) Dielectric Withstand Characteristics VI-200 E-Grade Parameter Input to output Output to baseplate Input to baseplate Min Typ VI-200 C-, I-, M-Grade Max Min Typ Max Units Test Conditions Baseplate earthed 3,000 3,000 VRMS 500 500 VRMS 1,500 1,500 VRMS Thermal Characteristics VI-200 E-Grade Parameter Min Efficiency Baseplate to sink thermal impedance Thermal shutdown [d] (Drivers only) [d] 90 Typ VI-200 C-, I-, M-Grade Max Min Typ 78 – 88% 80 – 90% 0.07 0.07 95 105 90 Units Test Conditions °C/Watt With Vicor P/N 20266 105 °C Cool and recycle power to restart Test Conditions Max 95 No overtemp protection in booster modules. Mechanical Specifications VI-200 E-Grade Parameter Weight VI-200 C-, I-, M-Grade Min Typ Max Min Typ Max Units 5.7 (160.2) 6.3 (178) 6.9 (195.8) 6.6 (187.2) 7.3 (208) 8.1 (228.8) Ounces (Grams) Product Grade Temperatures Parameter Storage Operating Units E -20 to +100 -10 to + 85 °C C -40 to +100 -25 to + 85 °C I -55 to +100 -40 to + 85 °C M -65 to +100 -55 to + 85 °C Notes Overtemperature shutdown 95°C typical (recycle power to restart) Maximum Capacitance, Rated Output Voltage 28 ≤50 150 >50 to 200 250 Maximum Capacitance, Rated Output Voltage ≥5V Rated VOUT (V) VI-200 DC-DC Converters Page 4 of 7 Rev 3.9 08/2017 VI-200, VE-200 Basic Module Operation F1 +IN C3 C3 (µF) = 400 VIN Minimum C2a C1a –IN Zero Current Switching Converter +OUT –OUT C1b C2b Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Design Guide & Applications Manual. Storage Output Connections and Considerations The permissible load current [e] must never be exceeded during normal, abnormal or test conditions. Converters subject to dynamic loading exceeding 25% of rated current must be reviewed by Vicor Applications Engineering to ensure that the converter will operate properly. Vicor products, when not installed in customer units, should be stored in ESD safe packaging in accordance with ANSI/ESD S20.20, “Protection of Electrical and Electronic Parts, Assemblies and Equipment” and should be maintained in a temperature controlled factory/warehouse environment not exposed to outside elements controlled between the temperature ranges of 15ºC and 38ºC. Humidity shall not be condensing, no minimum humidity when stored in an ESD compliant package. Under dynamic load, light load, or no load conditions, the converter may emit audible noise. Converters that utilize remote sense may require compensation circuitry to offset the phase lag caused by the external output leads and load impedance. Remote Sense leads must be protected for conditions such as lead reversal, noise pickup, open circuit, or excessive output lead resistance between the sense point and the converters output terminals. For applications that may draw more than the rated current, a fast acting electronic circuit breaker must be utilized to protect the converter. Under no circumstance should the rated current be exceeded. Utilizing or testing of current limit or short circuit current will damage the converter. Ensure that the total output capacitance connected to the converter does not exceed the limits on Page 4. [e] Permissible load current: Nominal Power Rating Nominal VOUT VI-200 DC-DC Converters Page 5 of 7 Rev 3.9 08/2017 VI-200, VE-200 VI-200 Mechanical Drawing Mechanical Drawing .50 (12,7) .30±.015 (7,6)±(0,38) 1.80 (45,7) 4.60 (116,8) 3.60 (91,4) 4 9 3 2.10 (53,3) VI-200 2 1 .15 (3,8) Standard 0.080 (2,0) Dia (2) places Solder plate over copper alloy 8 7 6 5 .15 (3,8) FULL R Product ID this surface 4.20 (106,7) 1.40 1.00 (35,6) .70 (25,4) .40 (17,8) (10,2) .35±.015 (8,9)±(0,38) Pin # Function 1 +In 2 Gate In 3 Gate Out 4 -In 5 +Out 6* +Sense 7* Trim 8* -Sense 9 -Out * Do not connect on booster modules Standard .040 (1,0) Dia (7) places Solder plate over copper alloy .22 (5,6) MIN .50 (12,7) .12 (3,0) .30 (7,6) Min RoHS 0.080 (2,0) Dia (2) places Matte tin over copper alloy RoHS .040 (1,0) Dia (7) places Matte tin over copper alloy 2.40 (61,0) 1.75 Max. (44,5) +.030 (0,76) -.000 (0) .01 Aluminum Base Packaging Options SlimMod Flangeless package 4.60”L x 1.80”W x 0.50”H (116,8 x 45,7 x 12,7mm) FinMod MegaMod Flangeless package with integral heat sink Chassis mount alternatives, one, two, or three outputs: up to 600W Longitudinal, 0.25”(6.35mm) fins — add suffix “–F1” Longitudinal, 0.50”(12.7mm) fins — add suffix “–F2” 1 up – 4.9¨ x 2.5¨ x 0.62¨ (124,4 x 63,5 x 15,7mm) 2 up – 4.9¨ x 4.9¨ x 0.62¨ (124,4 x 124,4 x 15,7mm) 3 up – 4.9¨ x 7.3¨ x 0.62¨ (124,4 x 185,4 x 15,7mm) BusMod To order the SlimMod configuration add the suffix “–S” to the standard module part number. Qty (2) grounding clips are included with each SlimMod P/N 32187 Transverse, 0.25”(6.35mm) fins — add suffix “–F3” Transverse, 0.50”(12.7mm) fins — add suffix “–F4” Available with longitudinal or transverse fins of 0.25”(6.35 mm) or 0.50”(12.7mm) height. Add the appropriate suffx to the module part number. Qty (4) grounding clips are included with each FinMod F1, F2 P/N 32185 F3, F4 P/N 32186 VI-200 DC-DC Converters Page 6 of 7 Rev 3.9 08/2017 4.60”L x 2.40”W x 1.08”H (116,8 x 61,0 x 27,4mm) To order the BusMod fully assembled, add suffix “–B1” to the standard module part number. To order the BusMod separately: Full-sized BusMod — P/N 06322 See BusMod Mechanical Drawings for more details. VI-200, VE-200 Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information. Vicor’s Standard Terms and Conditions and Product Warranty All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage (http://www.vicorpower.com/termsconditionswarranty) or upon request. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department. Contact Us: http://www.vicorpower.com/contact-us Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 www.vicorpower.com email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com ©2017 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation. All other trademarks, product names, logos and brands are property of their respective owners. VI-200 DC-DC Converters Page 7 of 7 Rev 3.9 08/2017
VI-2T1-CV-B1
物料型号: VI-200, VE-200

器件简介: - VI-200系列是Vicor的“零电流开关”组件级DC-DC转换器,已出货超过1400万单位。 - 这些转换器在高达2MHz的频率下运行,提供出色的功率密度、效率、噪声性能、可靠性和易用性。

引脚分配: - 1: +In (输入正) - 2: Gate In (门控输入) - 3: Gate Out (门控输出) - 4: -In (输入负) - 5: +Out (输出正) - 6: +Sense (远程感测正,注意不要在增压模块上连接) - 7': Trim (微调) - 8: -Sense (远程感测负) - 9: -Out (输出负)

参数特性: - 效率: VI-200 E-Grade 78-88%, VI-200 C-,I-, M-Grade 80-90% - 热阻抗: Baseplate to sink thermal impedance 0.07°C/Watt - 输入到输出的介电强度: 3,000 VRMS - 工作温度范围: E级 -10 to +85°C, C级 -25 to +85°C, M级 -55 to +85°C

功能详解: - 隔离输出 - 远程感测和电流限制 - 过压保护(OVP)和热关断 - 逻辑禁用 - 宽范围输出调节 - 兼容的功率增压模块 - ZCS功率架构 - 低噪声FM控制

应用信息: - 适用于需要高功率密度和高效率的应用场合。 - 增压模块(VI-Bxx)提供了一个简单、成本效益高、现成的解决方案,用于更高的功率输出需求。

封装信息: - 尺寸: 4.6” x 2.4” x 0.5” (116.8 x 61.0 x 12.7mm) - 封装选项包括SlimMod、FinMod和MegaMod等。
VI-2T1-CV-B1 价格&库存

很抱歉,暂时无法提供与“VI-2T1-CV-B1”相匹配的价格&库存,您可以联系我们找货

免费人工找货