0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VI-J1B-EZ-S

VI-J1B-EZ-S

  • 厂商:

    VICOR(威科)

  • 封装:

    -

  • 描述:

    CONVERTERMODDC/DC95V25W

  • 详情介绍
  • 数据手册
  • 价格&库存
VI-J1B-EZ-S 数据手册
Half Brick, DC-DC Converters VI-J00 VE-J00 ® S US C C NRTL US 25 to 100 Watts Features & Benefits Product Highlights • Isolated output The VI-J00 MiniMod family established a new standard in component-level DC-DC converters. This “junior” size complement to the higher power VI-200 family offers up to 100W of isolated and regulated power in a board mounted package. With thousands of input/output/power combinations, and with a maximum operating temperature rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system designers to meet demanding time to market requirements. • Up to 50W/in3 • cURus, cTÜVus • CE Marked • Up to 90% efficiency Utilizing Vicor’s “zero-current-switching” forward converter technology, proven by an installed base of over 8 million units, the MiniMod family combines state of the art power density with the efficiency, low noise and reliability required by next generation power systems. • Size: 2.28” x 2.4” x 0.5” (57,9 x 61,0 x 12,7mm) • Remote sense and current limit • Logic disable • Wide range output adjust • ZCS power architecture • Low noise FM control • RoHS compliant (VE verisons) Part Numbering VI — J 6 1 — C W Family VI = Non-RoHS Series J = J00 VE = RoHS Note: For additional packaging options, please see page 5. VI-J00 DC-DC Converters Page 1 of 7 Input Output Grade Power 0 = 12V N = 48V Z = 2V M = 10V K = 40V E = –10 to 100°C V = 24V 4 = 72V Y = 3.3V 1 = 12V 4 = 48V C = –25 to 100°C W = 100W W = 20A 1 = 24V T = 110V 0 = 5V P = 13.8V H = 52V I = – 40 to 100°C X = 75W X = 15A W = 24V 5 = 150V X = 5.2V 2 = 15V F = 72V M = –55 to 100°C Y = 50W Y = 10A 2 = 36V 6 = 300V W = 5.5V N = 18.5V D = 85V Z = 25W 3 = 48V 7 = 150/300V V = 5.8V 3 = 24V B = 95V T = 6.5V L = 28V R = 7.5V J = 36V Rev 3.0 06/2017 ≥ 5V < 5V Z = 5A VI-J00, VE-J00 Maximum Power Available for VI-Jxx-xx Output Low Line 75% Max Power Transient[a] 12 (10 – 20) n/a 22 24 (10 – 36) n/a 24 (21 – 32) 3.3 5 5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95 VOUT Designators 2 Voltage Nom. (Range) VIN Designators Input Z Y 0 X W V T R M 1 P 2 N 3 L J K 4 H F D B 0 X X Y Y Y Y Y Y X X X X X X X X X X X X X X n/a V -- Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y -- -- -- -- 18 36 1 W W W W W W X X W W W W W W W W W W W W W W 24 (18 – 36) n/a n/a W W W W W W W X X W W W W W W W W W W W W W W 36 (21 – 56) 18 60 2 Y Y Y Y Y Y Y Y X X X X X X X X X X X -- -- -- 48 (42 – 60) 36 72 3 W W W W W W X X W W W W W W W W W W W W W W 48 (36 – 76) n/a n/a N W W X X X X X X W W W W W W W W W W W W W W 72 (55 – 100) 45 110 4 W W W W W W X X W W W W W W W W W W W W W W 110 (66 – 160) n/a n/a T W W X X X X X X W W W W W W W W W W W W -- -- 150 (100 – 200) 85 215 5 W W W W W W X X W W W W W W W W W W W W W W 150 (100 – 375) n/a n/a 7 Y Y Y Y Y Y Y Y X X X X X X X X X X X -- -- -- 300 (200 – 400) 170 425 6 W W W W W W X X W W W W W W W W W W W W W W [a] Transient voltage for 1 second. Converter Specifications (Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.) Input Specifications VI-J00 E-Grade Parameter Min Inrush charge Input reflected ripple current – pp Input ripple rejection VI-J00 C-, I-, M-Grade Typ Max Units Test Conditions 60 x 10-6 60 x 10-6 100 x 10-6 Coulombs Nominal line 10% 10% IIN Nominal line, full load dB 120Hz, nominal line dB 2400Hz, nominal line Typ 25+20 Log Max Min (VV ) (VV ) V 20+20 Log ( V ) IN 30+20 Log OUT IN OUT IN OUT No load power dissipation VI-J00 DC-DC Converters Page 2 of 7 1.35 2 1.35 Rev 3.0 06/2017 2 Watts VI-J00, VE-J00 Converter Specifications (Cont.) (Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.) Output Characteristics VI-J00 E-Grade Parameter Min Setpoint accuracy VI-J00 C-, I-, M-Grade Typ Max 1% Min Typ Max Units Test Conditions 2% 0.5% 1% VNOM Load/line regulation 0.5% 0.05% 0.2% VNOM LL to HL, 10% to Full Load Load/line regulation 1% 0.2% 0.5% VNOM LL to HL, No Load to 10% 0.02 % / °C Over rated temp. Output temperature drift 0.02 0.01 Long term drift 0.02 0.02 %/1K hours Output ripple – pp: 2V, 3.3V 200 100 150 mV 20MHz bandwidth 5V 5% 2% 3% VNOM 20MHz bandwidth 10 – 95V 3% 0.75% 1.5% VNOM 20MHz bandwidth 110% VNOM Trim range[a] Total remote sense compensation 50% 110% 0.5 50% 0.5 Volts 0.25V max. neg. leg Current limit 105% 135% 105% 125% IFULL LOAD Automatic restart Short circuit current 105% 140% 105% 130% IFULL LOAD Automatic restart [a] 10V to 15V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range. 95V output –50 + 0% trim range. Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information, please refer to output connections on page 5. Control Pin Specifications VI-J00 E-Grade Parameter Min Gate out impedance Gate in impedance Gate in high threshold Gate in low threshold Typ VI-J00 C-, I-, M-Grade Max Min Units 50 Ohms 1000 1000 Ohms 6 0.65 VI-J00 DC-DC Converters Page 3 of 7 Max 50 6 Gate in low current Typ 0.65 6 Volts 6 Rev 3.0 06/2017 Volts mA Test Conditions Use open collector VI-J00, VE-J00 Converter Specifications (Cont.) (Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.) Dielectric Withstand Characteristics VI-J00 E-Grade Parameter Input to output Output to baseplate Input to baseplate Min Typ VI-J00 C-, I-, M-Grade Max Min Typ Max Units Test Conditions Baseplate earthed 3,000 3,000 VRMS 500 500 VRMS 1,500 1,500 VRMS Thermal Characteristics VI-J00 E-Grade Parameter Min Typ Efficiency Baseplate to sink [d] VI-J00 C-, I-, M-Grade Max Min Typ Max 78 – 88% 80 – 90% 0.14 0.14 Units Test Conditions °C/Watt With Vicor P/N 20267 Test Conditions No overtemp protection in booster modules. Mechanical Specifications VI-J00 E-Grade Parameter Weight VI-J00 C-, I-, M-Grade Min Typ Max Min Typ Max Units 2.9 (82.8) 3.2 (92) 3.6 (101.2) 3.4 (96.3) 3.8 (107) 4.1 (117.7) Ounces (Grams) Product Grade Temperatures Parameter Storage Operating Units E -20 to +105 -10 to + 100 °C C -40 to +105 -25 to + 100 °C I -55 to +105 -40 to + 100 °C M -65 to +105 -55 to + 100 °C Notes Maximum Capacitance, Rated Output Voltage 28 ≤50 150 >50 to 100 250 VI-J00 DC-DC Converters Page 4 of 7 Rev 3.0 06/2017 VI-J00, VE-J00 Basic Module Operation F1 +IN C3 C3 (µF) = C2a C1a –IN Zero Current Switching Converter +OUT –OUT C1b 400 VIN Minimum C2b Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Design Guide & Applications Manual. Storage Output Connections and Considerations The permissible load current [e] must never be exceeded during normal, abnormal or test conditions. Converters subject to dynamic loading exceeding 25% of rated current must be reviewed by Vicor Applications Engineering to ensure that the converter will operate properly. Vicor products, when not installed in customer units, should be stored in ESD safe packaging in accordance with ANSI/ESD S20.20, “Protection of Electrical and Electronic Parts, Assemblies and Equipment” and should be maintained in a temperature controlled factory/warehouse environment not exposed to outside elements controlled between the temperature ranges of 15ºC and 38ºC. Humidity shall not be condensing, no minimum humidity when stored in an ESD compliant package. Under dynamic load, light load, or no load conditions, the converter may emit audible noise. Converters that utilize remote sense may require compensation circuitry to offset the phase lag caused by the external output leads and load impedance. Remote Sense leads must be protected for conditions such as lead reversal, noise pickup, open circuit, or excessive output lead resistance between the sense point and the converters output terminals. For applications that may draw more than the rated current, a fast acting electronic circuit breaker must be utilized to protect the converter. Under no circumstance should the rated current be exceeded. Utilizing or testing of current limit or short circuit current will damage the converter. Ensure that the total output capacitance connected to the converter does not exceed the limits on Page 4. [e] Permissible load current: Nominal Power Rating VI-J00 DC-DC Converters Page 5 of 7 Nominal VOUT Rev 3.0 06/2017 VI-J00 Mechanical Diagram VI-J00, VE-J00 Mechanical Drawing .49 (12,4) .30±.015 (7,6)±(0,38) 2.28 (57,9) 1.30 (33,0) Standard 0.080 Dia (2) places Solder plate over copper alloy .65 (16,5) RoHS 0.080 Dia (2) places Matte tin over copper alloy Pin # 2.10 (53,4) 4 9 3 8 VI-J00 7 2 6 1 5 .15 (3,8) .70 .40 (17,8) (10,2) .15 (3,8) .12 (3,0) Gate In 3 Gate Out 4 -In 5 +Out +Sense Trim 7 8 –Sense 9 –Out RoHS 0.040 Dia (7) places Matte tin over copper alloy 2.40 (61,0) Product ID this surface .30 (7,6) Min. .22 (5,6) Min. .50 (12,7) +In 2 6 .35± .015 (8,9)±(0,38) Standard 0.040 (1,0) Dia (7) places Solder plate over copper alloy FULL R 1.90 (48,3) 1.40 1.00 (35,6) (25,4) Function 1 1.75 (44,4) Max. +.030 (0,76) -.000 (0) .01 Aluminum Base PACKAGING OPTIONS Flangeless package 2.28”L x 1.80”W x 0.50”H (57,9 x 45,7 x 12,7mm) Flangeless package with integral heat sink Longitudinal, 0.25”(6.35mm) fins — add suffix “–F1” Longitudinal, 0.50”(12.7mm) fins — add suffix “–F2” To order the SlimMod configuration add the suffix “–S” to the standard module part number. MegaMod Jr. Chassis mount alternatives, one, two or three outputs: up to 300W 1 up – 2.58¨ x 2.5¨ x 0.62¨ (65,5 x 63,5 x 15,7mm) 2 up – 2.58¨ x 4.9¨ x 0.62¨ (65,5 x 124,5 x 15,7mm) 3 up – 2.58¨ x 7.3¨ x 0.62¨ (65,5 x 185,4 x 15,7mm) BusMod Qty (2) grounding clips are included with each SlimMod P/N 32187 Transverse, 0.25”(6.35mm) fins — add suffix “–F3” Transverse, 0.50”(12.7mm) fins — add suffix “–F4” Available with longitudinal or transverse fins of 0.25”(6.35mm) or 0.50”(12.7mm) height. Add the appropriate suffix to the module part number. Qty (4) grounding clips are included with each FinMod F1, F2 P/N 32185 F3, F4 P/N 32186 VI-J00 DC-DC Converters Page 6 of 7 Rev 3.0 06/2017 2.28”L x 2.40”W x 1.08”H (57,9 x 61,0 x 27,4mm) To order the BusMod fully assembled, add suffix “–B1” to the standard module part number. To order the BusMod separately: Half-sized BusMod — P/N 18952 See BusMod Mechanical Drawings for more details. VI-J00, VE-J00 Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information. Vicor’s Standard Terms and Conditions and Product Warranty All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage (http://www.vicorpower.com/termsconditionswarranty) or upon request. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department. Contact Us: http://www.vicorpower.com/contact-us Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 www.vicorpower.com email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com ©2017 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation. All other trademarks, product names, logos and brands are property of their respective owners. VI-J00 DC-DC Converters Page 7 of 7 Rev 3.0 06/2017
VI-J1B-EZ-S
物料型号: VI-J00, VE-J00

器件简介: - VI-J00 MiniMod 系列是高功率密度的板载DC-DC转换器,提供高达100W的隔离和稳压电源。 - 采用Vicor的零电流开关正向转换器技术,具有高效率、低噪音和可靠性。

引脚分配: - 1: +in - 2: Gate in - 3: Gate Out - 4: -In - 5: +Out - 6: +Sense - 7: Trim - 8: -Sense - 9: -Out

参数特性: - 尺寸: 2.28” x 2.4” x 0.5” (57.9 x 61.0 x 12.7mm) - 效率: 最高可达90% - 隔离输出 - 远程感测和电流限制 - 逻辑禁用 - 宽范围输出调整 - 低噪音FM控制 - 符合RoHS标准(VE版本)

功能详解: - 利用Vicor的零电流开关正向转换器技术,MiniMod系列结合了先进的功率密度和下一代电源系统所需的效率、低噪音和可靠性。

应用信息: - 适用于需要高功率密度和高效率的电源系统设计。 - 提供多种输入/输出/功率组合,满足严格的市场需求。

封装信息: - 提供多种封装选项,包括无法兰封装、带集成散热器的无法兰封装、MegaMod Jr.、BusMod等。 - 还提供了不同尺寸和形状的散热片选项。
VI-J1B-EZ-S 价格&库存

很抱歉,暂时无法提供与“VI-J1B-EZ-S”相匹配的价格&库存,您可以联系我们找货

免费人工找货