0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VI-PUL0-CVY

VI-PUL0-CVY

  • 厂商:

    VICOR

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 28V 5V 150W

  • 数据手册
  • 价格&库存
VI-PUL0-CVY 数据手册
New Configurations Are Not Available FlatPAC™ 50 to 600 Watts Autoranging, AC-DC Switchers Features & Benefits Configuration Chart • • • • 0 1 1 E U U U Typical Model: VI-RU - RoHS compliant (VE versions) Microcontroller architecture Inputs: 115/230 Vac autoranging Meets FCC Part 15, EN55022, Class B conducted emissions • 80 – 90% efficiency • Any output: 1 to 95VDC Input Characteristics 90–132/180–264 Vac U = Autoranging Substitute VE– for VI– for RoHS compliant versions Total Power # of Converters Dimensions Configuration • Module enable/disable (except LU series) • UL, TÜV, CE marked • Remote sense and current limit • BUS OK and AC OK (except LU series) • 40ms ride-through time • OVP and thermal shutdown • 1 output; up to 200W • 1 or 2 outputs; up to 400W Single Output 9.25” x 2.5” x 1.37” VI-LU 50 – 200W 1 (234,8 x 124,5 x 34,8mm) VI-MU - 200 – 400W 2 9.25” x 4.9” x 1.37” (234,8 x 124,5 x 34,8mm) FF AA F A 9.25” x 7.3” x 1.37” VI-NU - 300 – 600W 3 FF AA (234,8 x 185,4 x 34,8mm) A F Dual Output FF AA 9.25” x 4.9” x 1.37” VI-PU - 100 – 400W 2 (234,8 x 124,5 x 34,8mm) VI-QU - 150 – 600W 3 9.25” x 7.3” x 1.37” (234,8 x 185,4 x 34,8mm) A A F FFFA FAA • 1, 2, or 3 outputs; up to 600W F Triple Output Product Highlights F VI-RU If you’re looking for the convenience of a complete, A flat plate heat sink for use in conduction cooled applications may be specified as an alternate to the standard finned version by adding “CC” to the end of the model number. The Vicor FlatPAC is also available with a current controlled output using BatMod converter modules of 12, 24, or 48VDC outputs. This option is specified by appending “BM” or “BC” (for conduction cooled versions) to the end of the FlatPAC model number. F - 150 – 600W 3 A W = 5.5V M = 10V N = 18.5V K = 40V D = 85V Y = 3.3V V = 5.8V 1 = 12V 3 = 24V 4 = 48V B = 95V T = 6.5V P = 13.8V L = 28V H = 52V R = 7.5V 2 = 15V J = 36V F = 72V X = 5.2V Product Grade Temps. °C Grade F Operating Output Power/Current Storage E = 0 to +85 –20 to +100 A C = 0 to +85 –20 to +100 F I = –30 to +85 –55 to +100 Temperatures apply to product case. A Output Power/Current F 9.25” x 7.3” 1.37” (234,8 x 185,4 x 34,8mm) Z = 2V A F 0 = 5V Mixing VI-200 and BatMods in a single FlatPAC is not permissible. The FlatPAC’s contemporary design allows us to configure your order quickly and provide rapid turnaround on standard models. It is truly a complete power solution, enabling you to spend more time designing your system and less time worrying about how to power it. A A A FFA FA F FA Voltage FFA FAA FA Output low-profile, agency-approved switching power supply, look no further. The FlatPAC combines the Vicor workhorse VI-200 family of DC-DC converters with a modular package and front-end subassembly to provide from 50 to 600W of output power from one to three outputs. FlatPAC™ Page 1 of 6 Output F FA A 1: 5 VDC at 200W 2: 12 VDC at 200W 3: 12 VDC at 200W Input 115/230 Vac V AOUT ≥5V W = 100W V = 150W U = 200W S = 300W Q = 400W VOUT < 5V VOUT ≥5V VOUT < 5V Y = 50W X = 75W W = 100W V = 150W U = 200W Y = 10A X = 15A W = 20A V = 30A U = 40A Output Power/Current F W = 20A V = 30A U = 40A S = 60A Q = 80A A VOUT ≥5V S = 300W P = 450W M = 600W VOUT < 5V S = 60A P = 90A M = 120A Options A BC = BatMod/Conduction Cooled BM = BatMod CC = Conduction Cooled Note: Product images may not highlight current product markings. Rev 1.8 11/2021 FlatPAC™ New Configurations Are Not Available Specifications (typical at 25°C, nominal line and 75% load, unless otherwise specified) INPUT SPECIFICATIONS Parameter Min Typ Max Unit Notes AC line input Autoranging 90 – 132/180 – 264 Vac Line frequency 47 – 63 47 – 440 Hz Hz (C-Grade and E-Grade) (I-Grade) Inrush current: 115 Vac operation: 1 converter 2 converters 3 converters 16 23 39 A A A @ peak line @ peak line @ peak line Inrush current: 230 Vac operation 1 converter 2 converters 3 converters 32 47 78 A A A @ peak line @ peak line @ peak line Ride-through time (full load) 90/180 Vac low line 115/230 Vac nominal line 5 40 ms ms minimum minimum AC fail warning time 5 ms minimum (low line, full load) V V @ 1mA (1.5mA max.) AC and BUS OK (2 and 3 converter models only) Off state – Vce On state – Vcesat 70 0.4 Module disable (2 and 3 converter models only, optically isolated LED input) Continuous forward current 1 – 30 Forward voltage 1.65 mA V Dielectric withstand Primary to chassis GND Primary to secondary Secondary to chassis GND VDC VDC VDC 2,121 4,242 707 @ 30mA OUTPUT SPECIFICATIONS E-Grade Parameter Min Set point accuracy C-, I-Grade Typ Max 1% 2% Load/line regulation Min 0.5% 1% Typ Max Unit Notes 0.5% 1% VNOM 0.05% 0.2% 0.2% 0.5% VNOM VNOM LL to HL, 10% to Full Load LL to HL, No Load to full load 0.02 %/°C Over rated temperature Output temperature drift 0.02 0.01 Long term drift 0.02 0.02 %/1k hours Output ripple 2V 150mV 60mV 100mV p-p 20MHz bandwidth 5V 5% 2% 3% p-p 20MHz bandwidth 10 – 48V 3% 0.75% 1.5% p-p 20MHz bandwidth Output voltage trimming[a] 50% 110% 50% 110% Total remote sense compensation 0.5 OVP set point Current limit [b] Short circuit current FlatPAC™ Page 2 of 6 125% 0.5 115% 125% 135% Volts 0.25V max. neg. leg VNOM Recycle power 105% 135% 105% 125% INOM 20% 140% 20% 130% INOM Rev 1.8 11/2021 Automatic restart New Configurations Are Not Available FlatPAC™ Specifications (Cont.) THERMAL CHARACTERISTICS E-Grade Parameter Min Efficiency C-, I- Grade Typ Max Min 78 – 88% Typ Max Units 80 – 90% Test Conditions @ 5V and higher Shut down temp. — case 90 95 105 90 95 105 °C Cool and recycle power to restart Operating temp. — case See Thermal Curves 85 85 °C Max Units MECHANICAL SPECIFICATIONS E-Grade Parameter Min [c] Weight Typ C-, I- Grade Max Min Typ Test Conditions 22.4 22.4 Ounces (652) (652) (Grams) AGENCY APPROVALS Safety Standards Markings UL1604, UL60950-1 cURus UL / CSA / EN / IEC 60950-1 Notes cTÜVus, CE Mark Low Voltage Directive EMI / EMC Characteristics (Performed on selected samples representative of the U Series FlatPac product family.) Parameter Notes Conducted emissions, LISN EN 55022 and FCC R&R, Part 15, Subpart B, Class B Radiated emissions, 10 meters EN 55022; 1998 and FCC R&R, Part 15, Subpart B, Class A Electrostatic discharge IEC 61000-4-2: 1995, Level 4; ±8kV Contact, ± 15kV Air Discharge RF radiated immunity, E-field IEC 61000-4-3: 1997; 80MHz to 1.0GHz, 3V/M, CW Electrical fast transients/burst EN 61000-4-4: 1995, Level 3; ±2kV, Surge immunity EN 61000-4-5: 1996 Class 3; ±2kV Line to Ground, ±1kV Line to Line RF conducted immunity IEC 61000-4-6: 1996, class 3, 10VRMS, 150kHz to 80MHz Power frequency magnetic field immunity IEC 61000-4-8: 1994, 30 to 300 A/M, 50Hz Voltage dips and interrupts IEC 61000-4-11: 1994 [a] 10V to 15V outputs, trim range ± 10%. Consult factory for wider trim range. [b] Output voltages of 5V or less incorporate foldback current limiting, outputs greater [c] For MU, PU series, multiply value by 2; for NU, QU, RU series, multiply value by 3. FlatPAC™ Page 3 of 6 Rev 1.8 11/2021 than 5V incorporate straight line current limiting. FlatPAC™ New Configurations Are Not Available Thermal Curves FREE AIR 50LFM 100LFM 250LFM 750LFM 500LFM 1000LFM 5V Output 350 Output Power (Watts) Output Power (Watts) 150 200LFM FREE AIR 400LFM 125 100 75 150 50 0 5 10 15 20 25 30 35 40 45 50 Temperature (°C) AmbientAmbient Temperature (Deg. C) 55 60 65 70 75 80 85 1000LFM 200 25 FREE AIR, V 800LFM 250 100 FREE AIR, H 525 600LFM 300 50 0 600 Output (Watts) Output Power Power (Watts) 400 175 Output Power (Watts) Output Power (Watts) 200 375 300 225 150 75 200LFM 0 450 0 5 10 15 20 400LFM 25 30 35 40 45 50 55 60 AmbientTemperature Temperature (°C) Ambient (Deg. C) LU Series 600LFM 65 70 75 80 800LFM 0 85 0 5 10 15 20 25 30 1000LFM 35 40 45 50 55 60 65 70 75 80 85 65 70 75 80 85 Ambient Temperature (°C) C) Ambient Temperature (Deg. MU, PU Series NU, QU, RU Series 400 600 175 350 525 150 300 450 125 100 75 250 200 150 50 100 25 50 0 0 0 5 10 15 20 25 30 35 40 45 50 AmbientAmbient Temperature (Deg. C) Temperature (°C) 55 60 65 70 75 80 Output (Watts) Output Power Power (Watts) 200 Output Power (Watts) Output Power (Watts) Output Power (Watts) Output Power (Watts) 10 to 48V Output 85 375 300 225 150 75 0 5 LU Series 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 0 85 0 5 10 15 20 25 30 35 40 45 50 55 60 AmbientTemperature Temperature (°C) Ambient (Deg. C) Ambient Temperature (°C) C) Ambient Temperature (Deg. MU, PU Series NU, QU, RU Series Application Circuits VLINE > 90 (180)Vac AC Line AC Line Interrupted AC-OK BUS-OK T0 T1 T2 T4 T3 Conditions: Full Load 90 (180)Vac, AC Line MOD-DIS – MOD-DIS + AC-OK – AC-OK + BUS-OK – BUS-OK + AC Mains Earth Ground Internal Supervisory Circuits (Optocouplers) L1 L2/N 2-Up and 3-Up Time Interval Min Typ Max Units T0-T1 0 0.1 1.0 ms T2-T3 0 40 – ms T2-T4 5 – – ms T3-T4 5 – – ms Notes Ride-through time Hold-up time AC fail warning time Power Up and Power Down Sequencing 1-Up GND + Vout +O +S Trim –S AC Mains Connections R1 R2 10K –O Vout RTN Resistor Values for Trimming Standard Output Voltages Nom. Output Voltage 5V 12V 15V 24V 28V 48V Trim Range R1(kΩ) 0.953 15.8 22.1 41.2 48.7 90.9 +10%, -10% R2(kΩ) 90 90 90 90 90 90 FlatPAC™ Page 4 of 6 Rev 1.8 11/2021 Output Trimming FlatPAC™ New Configurations Are Not Available Mechanical Drawings Inputs 1 MOD DIS– Input connector, 2 MOD DIS+ TE Connectivity P/N 644488-6; 3 AC OK– mating connector 4 AC OK+ 5 BUS OK– 6 BUS OK+ 7 AC IN L1 Terminals for 8 AC IN L2/N #16-12 AWG wire 9 CHASSIS GND Outputs 10 +OUT (#10-32 Stud) 11 +OUT 12 +SENSE (VTRIM*) 13 TRIM (ITRIM*) 14 –SENSE (IMON*) 15 –OUT 16 –OUT (#10-32 Stud) STANDARD Models 1.375 ±0.020 (34,91 ±0,51) 1.11 ( 28,19) 0.50 (12,57) Output connector, TE Connectivity P/N 644486-5; mating connector 9.245 ±0.030 (234,82 ±0,76) CONDUCTION COOLED Models “–CC” *On FlatPACs with BatMODs only. LU Series 2.156 ±0.010 (54,76 ±0,25) 1.27 (32,26) 10 11 12 13 14 15 16 OUTPUT 1 2.540 ±0.030 (64,52 ±0,76) MOUNTING HOLE ø 0.15 ±0.01 THRU 4 PLACES 7 8 9 0.192 ±0.010 (4,88 ±0,25) 0.18 (4,57) 6.00 (152,4) MU Series PU Series 7 8 9 6.00 (152,4) NU Series QU Series MOUNTING HOLE ø 0.15 ±0.01 THRU 6 PLACES 10 7.380 ±0.030 (187,45 ±0,76) 1 2 3 4 5 6 7.000 ±0.010 (177,8 ±0,25) + 16 10 11 12 13 14 15 16 10 10 16 16 10 11 12 13 14 15 16 10 11 12 13 14 15 16 RU Series + 2.290 ±0.010 (58,17 ±0,25) 0.190 ±0.010 (4,83 ±0,25) 0.18 (4,57) 6.00 (152,4) Rev 1.8 11/2021 OUTPUT 1 1.93 (49,02) OUTPUT 1 7 8 9 – 10 11 12 13 14 15 16 10 11 12 13 14 15 16 10 11 12 13 14 15 16 – 4.710 ±0.010 (119,63 ±0,25) 5.48 (139,19) FlatPAC™ Page 5 of 6 10 11 12 13 14 15 16 OUTPUT 3 0.199 ±0.010 0.199 ±0.010 (5,05 ±0,25) 0.18 (5,05 ±0,25) 0.18 6.00 (4,57) (152,4) (4,57) 10 11 12 13 14 15 16 – OUTPUT 2 1.17 (29,72) 72.281 ±0.010 8(57,94 ±0,25) 9 10 11 12 13 14 15 16 OUTPUT 1 1.17 (29,72) 2.281 ±0.010 (57,94 ±0,25) OUTPUT 2 3.83 (97,16) – 10 11 12 + 13 14 15 16 + + OUTPUT 1 3.83 (97,16) 4.562 ±0.010 (115,87 ±0,25) 10 11 12 13 14 15 16 OUTPUT 2 4.562 ±0.010 (115,87 ±0,25) 4.960 ±0.030 (125,98 ±0,76) + OUTPUT 2 4.960 ±0.030 (125,98 ±0,76) 10 11 12 13 14 15 16 OUTPUT 1 MOUNTING HOLE MOUNTING HOLE ø 0.15 ±0.01 THRU ø 0.15 ±0.01 THRU 5 PLACES 5 PLACES + – New Configurations Are Not Available FlatPAC™ Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Visit https://www.vicorpower.com/ac-dc/power-systems/50-600-watt-power-system for the latest product information. Vicor’s Standard Terms and Conditions and Product Warranty All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage (http://www.vicorpower.com/termsconditionswarranty) or upon request. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department. Contact Us: http://www.vicorpower.com/contact-us Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 www.vicorpower.com email Customer Service: custserv@vicorpower.com Technical Support: apps@vicorpower.com ©2021 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation. All other trademarks, product names, logos and brands are property of their respective owners. FlatPAC™ Page 6 of 6 Rev 1.8 11/2021
VI-PUL0-CVY 价格&库存

很抱歉,暂时无法提供与“VI-PUL0-CVY”相匹配的价格&库存,您可以联系我们找货

免费人工找货