UFB60FA40P
Vishay Semiconductors
Insulated Ultrafast Rectifier Module, 60 A
FEATURES
• Two fully independent diodes • Ceramic fully insulated package (VISOL = 2500 VAC) • Ultrafast reverse recovery • Ultrasoft reverse recovery current shape • Low forward voltage
SOT-227
• Optimized for power conversion: welding and industrial SMPS applications • Industry standard outline • Plug-in compatible with other SOT-227 packages • Easy to assemble • Direct mounting to heatsink • UL approved file E78996 • Compliant to RoHS directive 2002/95/EC • Designed and qualified for industrial level
PRODUCT SUMMARY
VR IF(AV) at TC = 90 °C trr 400 V 60 A 46 ns
DESCRIPTION
The UFB60FA40P insulated modules integrate two state of the art Vishay Semiconductors ultrafast recovery rectifiers in the compact, industry standard SOT-227 package. The planar structure of the diodes, and the platinum doping life time control, provide a ultrasoft recovery current shape, together with the best overall performance, ruggedness and reliability characteristics. These devices are thus intended for high frequency applications in which the switching energy is designed not to be predominant portion of the total energy, such as in the output rectification stage of welding machines, SMPS, dc-to-dc converters. Their extremely optimized stored charge and low recovery current reduce both over dissipation in the switching elements (and snubbers) and EMI/RFI.
ABSOLUTE MAXIMUM RATINGS
PARAMETER Cathode to anode voltage Continuous forward current per diode Single pulse forward current per diode Maximum power dissipation per module RMS isolation voltage Operating junction and storage temperatures SYMBOL VR IF IFSM PD VISOL TJ, TStg TC = 90 °C TC = 25 °C TC = 90 °C Any terminal to case, t = 1 minute TEST CONDITIONS MAX. 400 30 A 250 64 2500 - 55 to 150 W V °C UNITS V
Document Number: 94521 Revision: 21-Jul-10
For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
www.vishay.com 1
UFB60FA40P
Vishay Semiconductors
Insulated Ultrafast Rectifier Module, 60 A
ELECTRICAL SPECIFICATIONS PER DIODE (TJ = 25 °C unless otherwise specified)
PARAMETER Cathode to anode breakdown voltage Forward voltage SYMBOL VBR VFM IR = 100 μA IF = 30 A IF = 30 A, TJ = 150 °C VR = VR rated TJ = 150 °C, VR = VR rated VR = 400 V TEST CONDITIONS MIN. 400 TYP. 1.13 0.93 68 MAX. 1.39 1.07 100 1.0 μA mA pF V UNITS
Reverse leakage current Junction capacitance
IRM CT
DYNAMIC RECOVERY CHARACTERISTICS PER DIODE (TJ = 25 °C unless otherwise specified)
PARAMETER SYMBOL TEST CONDITIONS IF = 1.0 A, dIF/dt = 200 A/μs, VR = 30 V Reverse recovery time trr TJ = 25 °C TJ = 125 °C Peak recovery current IRRM TJ = 25 °C TJ = 125 °C TJ = 25 °C TJ = 125 °C IF = 30 A dIF/dt = 200 A/μs VR = 200 V MIN. TYP. 32 67 120 6.8 15 228 900 MAX. 46 A nC ns UNITS
Reverse recovery charge
Qrr
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER Junction to case, single leg conducting Junction to case, both leg conducting Case to heatsink Weight Mounting torque SYMBOL TEST CONDITIONS MIN. RthJC RthCS Flat, greased surface 0.05 30 1.3 0.95 K/W g Nm TYP. MAX. 1.9 UNITS °C/W
www.vishay.com 2
For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
Document Number: 94521 Revision: 21-Jul-10
UFB60FA40P
Insulated Ultrafast Rectifier Module, 60 A
100
1000
Reverse Current - I R (µA)
Vishay Semiconductors
Tj = 150˚C
10 1 0.1
125˚C
25˚C
0.01 0.001 0 100 200 300 400
Reverse Voltage - VR (V)
Instantaneous Forward Current - I F (A)
100
Fig. 2 - Typical Values of Reverse Current vs. Reverse Voltage
Tj = 150˚C
Junction Capacitance - C T (pF)
1000
Tj = 125˚C
10
Tj = 25˚C
100
T = 25˚C
J
1 0 0.5 1 1.5 2
Forward Voltage Drop - VFM (V)
10 1 10 100 1000
Reverse Voltage - VR (V)
Fig. 1 - Maximum Forward Voltage Drop Characteristics (Per Diode)
10
Thermal Impedance Z thJC (°C/W)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage
1
Single Pulse (Thermal Impedance)
PDM
t1
0.1
Notes: 1. Duty factor D = t1/ t2
t2
2. Peak Tj = Pdm x ZthJC + Tc
0.01 0.0001
0.001 0.01 0.1 t 1, Rectangular Pulse Duration (Seconds)
1
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics (Per Diode)
Document Number: 94521 Revision: 21-Jul-10
For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
www.vishay.com 3
UFB60FA40P
Vishay Semiconductors
Insulated Ultrafast Rectifier Module, 60 A
150
If = 30A Vrr = 100V
160
Allowable Case Temperature (°C)
140 130 120
DC
trr ( ns )
140 120 100 80
Square wave (D = 0.50)
Tj = 125˚C
110 100 90 80
60 Rated Vr applied 40 see note (1)
70
Tj = 25˚C
20 0 10 20 30 40 50 60 70
60 50 100
dI F /dt (A/µs ) Average Forward Current - I F(AV) (A)
1000
Fig. 5 - Maximum Allowable Case Temperature vs. Average Forward Current (Per Leg)
Fig. 7 - Typical Reverse Recovery Time vs. dIF/dt
2400
70
RMS Limit
Average Power Loss ( W )
60 50
DC
Qrr ( nC )
2000
If = 30A Vrr = 100V Tj = 125˚C
1600
40 30 20 10 0 0 10 20 30 40 50 60 70
Average Forward Current - I F(AV) (A)
1200
D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50
800
Tj = 25˚C
400
0 100
dI F /dt (A/µs )
1000
Fig. 6 - Forward Power Loss Characteristics (Per Leg)
Fig. 8 - Typical Stored Charge vs. dIF/dt
Note (1) Formula used: T = T - (Pd + Pd C J REV) x RthJC; Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6); PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR
www.vishay.com 4
For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
Document Number: 94521 Revision: 21-Jul-10
UFB60FA40P
Insulated Ultrafast Rectifier Module, 60 A
VR = 200 V
Vishay Semiconductors
0.01 Ω L = 70 μH D.U.T.
dIF/dt adjust
D G IRFP250 S
Fig. 9 - Reverse Recovery Parameter Test Circuit
(3)
IF
0
trr ta tb
Qrr
(2)
(4)
IRRM
0.5 IRRM dI(rec)M/dt (5) 0.75 IRRM
(1) dIF/dt (1) dIF/dt - rate of change of current through zero crossing (2) IRRM - peak reverse recovery current (3) trr - reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current. (4) Qrr - area under curve defined by trr and IRRM Qrr = trr x IRRM 2
(5) dI(rec)M/dt - peak rate of change of current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and Definitions
Document Number: 94521 Revision: 21-Jul-10
For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
www.vishay.com 5
UFB60FA40P
Vishay Semiconductors
ORDERING INFORMATION TABLE
Device code
Insulated Ultrafast Rectifier Module, 60 A
UF
1 1 2 3 4 5 6 7 -
B
2
60
3
F
4
A
5
40
6
P
7
Ultrafast rectifier Ultrafast Pt diffused Current rating (60 = 60 A) Circuit configuration (2 separate diodes, parallel pin-out) Package indicator (SOT-227 standard isolated base) Voltage rating (40 = 400 V) P = Lead (Pb)-free
CIRCUIT CONFIGURATION
1 4
2
3
LINKS TO RELATED DOCUMENTS Dimensions Packaging information www.vishay.com/doc?95036 www.vishay.com/doc?95037
www.vishay.com 6
For technical questions within your region, please contact one of the following: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
Document Number: 94521 Revision: 21-Jul-10
Outline Dimensions
Vishay Semiconductors
SOT-227
DIMENSIONS in millimeters (inches)
38.30 (1.508) 37.80 (1.488) Ø 4.40 (0.173) Ø 4.20 (0.165) 4 4 x M4 nuts -A3 6.25 (0.246) 12.50 (0.492) 1 7.50 (0.295) 15.00 (0.590) 30.20 (1.189) 29.80 (1.173) 8.10 (0.319) 4x 7.70 (0.303) 2.10 (0.082) 1.90 (0.075) 2 R full 25.70 (1.012) 25.20 (0.992) -BChamfer 2.00 (0.079) x 45°
0.25 (0.010) M C A M B M 2.10 (0.082) 1.90 (0.075) -C0.12 (0.005)
12.30 (0.484) 11.80 (0.464)
Notes • Dimensioning and tolerancing per ANSI Y14.5M-1982 • Controlling dimension: millimeter
Document Number: 95036 Revision: 28-Aug-07
For technical questions, contact: indmodules@vishay.com
www.vishay.com 1
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000 Revision: 11-Mar-11
www.vishay.com 1