200 V - 1,000 V Single Phase Bridge
3.0 A Forward Current 70 ns - 3000 ns Recovery Time
1202C - 1210C 1202FC - 1210FC 1202UFC - 1210UFC
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number Working Reverse Voltage (Vrwm) Average Rectified Current @TC (Io) 55°C Volts 1202C 1206C 1210C 1202FC 1206FC 1210FC 1202UFC 1206UFC 1210UFC Amps 100°C Amps Reverse Current @ Vrwm (Ir) 25°C µA 100°C µA 25°C Volts Amps Forward Voltage 1 Cycle Surge Current tp=8.3ms (Ifsm) 25°C Amps Repetitive Surge Current (Ifrm) 25°C Amps Reverse Recovery Time (1) (Trr) 25°C ns °C / W Thermal Impd.
(Vf)
uJ-C
200 600 1000 200 600 1000 200 600 1000
3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
25 25 25 25 25 25 25 25 25
1.1 1.1 1.1 1.5 1.5 1.5 1.7 1.7 1.7
3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
150 150 150 100 100 100 100 100 100
25 25 25 20 20 20 20 20 20
3000 3000 3000 150 150 150 70 70 70
21 21 21 21 21 21 21 21 21
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp.= -55°C to +150°C Stg. Temp.= -55°C to +150°C
10
.625 (15.87)
.275(6.98) .040(1.02) DIA. .200(5.08)
+
AC
AC
_
+
AC
_
.110(2.79) .50(12.7) MIN.
.825 (20.95)
AC
Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice.
VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291
TEL 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com
231
1202C - 1210C • 1202FC - 1210FC • 1202UFC - 1210UFC
3.5 3 Maximum Current (I) Forward Voltage (V) 2.5 2 1.5 1 0.5 0 25 50 75 100 125 Ambient Temperature (°C) Temperature (C) 150
MAXIMUM FORWARD CURRENT VS. TEMPERATURE
2.4 2.2 2.0 1.8 1.6 1.4 1.2
TYPICAL FORWARD VOLTAGE VS. FORWARD CURRENT AT 25°C
1200FC 1200UFC
1200C
1.0 0.8 0.6 0 3 6 9 Forward Current (A) 12 15
1000
REVERSE CURRENT VS. TEMPERATURE AT Vrwm
Reverse Current (uA)
100
10
1 25 50 75 100 Temperature (C) Temperature (°C) 125 150
232