200 V - 1,000 V Three Phase Bridge
2.0 A Forward Current 70 ns - 3000 ns Recovery Time
3102 - 3110 3102F - 3110F 3102UF - 3110UF
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number Working Reverse Voltage (Vrwm) Average Rectified Current @TC (Io) 55°C Volts 3102 3106 3110 3102F 3106F 3110F 3102UF 3106UF 3110UF Amps 100°C Amps Reverse Current @ Vrwm (Ir) 25°C µA 100°C µA 25°C Volts Amps Forward Voltage 1 Cycle Surge Current tp=8.3ms (Ifsm) 25°C Amps Repetitive Surge Current (Ifrm) 25°C Amps Reverse Recovery Time (1) (Trr) 25°C ns °C / W Thermal Impd.
(Vf)
uJ-C
200 600 1000 200 600 1000 200 600 1000
2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
25 25 25 25 25 25 25 25 25
1.1 1.1 1.1 1.3 1.3 1.3 1.7 1.7 1.7
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
30 30 30 25 25 25 25 25 25
10 10 10 6 6 6 5 5 5
3000 3000 3000 150 150 150 70 70 70
22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp.= -55°C to +150°C Stg. Temp.= -55°C to +150°C
.42(10.67)
.18(4.57) .09(2.29) 22 AWG Tinned Copper Wire
AC
11
+ AC AC AC _
.62 (15.75)
+
_
.19 (4.83) .87(22.10) MIN.
AC
AC
.25(6.35)
1.00(25.4)
Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice.
VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291
TEL 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com
251
3102 - 3110 • 3102F - 3110F • 3102UF - 3110UF
2.5
MAXIMUM FORWARD CURRENT VS. TEMPERATURE
2.5
TYPICAL FORWARD VOLTAGE VS. FORWARD CURRENT AT 25°C
2 Maximum Current (I) Forward Voltage (V)
2.0
3100UF 3100F
1.5
1.5
3100
1
1.0
0.5
0.5
0 25 50 75 100 125 Temperature (C) Ambient Temperature (°C) 150
0.0 0 1 2 3 4 5 6 Forward Current (A) 7 8 9
1000
REVERSE CURRENT VS. TEMPERATURE AT Vrwm
Reverse Current (uA)
100
10
1 25 50 75 100 Temperature (C) Temperature (°C) 125 150
252
很抱歉,暂时无法提供与“3102UF”相匹配的价格&库存,您可以联系我们找货