Datasheet
W-series terminal with clamping yoke connection
WSI 6
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com
The fuse terminals of the Weidmüller W Series are available in
two different forms:
• Fuse terminal with pivoting retaining lever
• Fuse terminal with plug-in SIHA fuse holder
General ordering data
Order No.
Type
Version
EAN
Qty.
1011000000
WSI 6
W-series terminal with clamping yoke
connection, Fuse terminal, Rated cross-section:
6 mm², Screw connection
4008190105624
50 pc(s).
Creation date September 20, 2011 9:56:40 PM CEST
Last update 08.08.2011 / We reserve the right to make technical changes.
1
Datasheet
W-series terminal with clamping yoke connection
WSI 6
Technical data
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com
Dimensions
Length
Height
Weight
60 mm
61 mm
19.4 g
Width
Height of lowest version
7.9 mm
62 mm
-50 °C...+120 °C
Storage temperature
200039-1057876
30 V
10 A
10 A
20 AWG
Voltage size B (CSA)
Voltage size D (CSA)
Current size C (CSA)
Wire cross section max. (CSA)
30 V
30 V
10 A
8 AWG
E60693VOL1SEC38
9.5 A
20 AWG
Voltage size C (UR)
Conductor size Factory wiring max. (UR)
Conductor size Field wiring max. (UR)
600 V
8 AWG
8 AWG
Wemid
V-0
Colour
dark beige
W-series terminal with
clamping yoke connection
on side
2
No
Yes
Type of connection
Number of levels
No. of clamping points per level
Mounting rail
Screw connection
1
2
TS 35
No
right
Number of identical terminals
Type of mounting
1
Snap-on
Temperatures
Operating temperature
CSA ratings data
Certificate No. (CSA)
Voltage size C (CSA)
Current size B (CSA)
Current size D (CSA)
Wire cross section min. (CSA)
UL ratings data
Certificate No. (UR)
Current size C (UR)
Conductor size Factory wiring min. (UR)
Material data
Material
Flammability class UL 94
System specifications
Product family
Connection direction
Number of connections
Levels cross-connected internally
End cover plate required
Additional technical data
Explosion-tested version
Open sides
Conductors for clamping (additional connection)
Conductor cross-section, flexible plus plastic
collar DIN 46228/1, further connection, min. 0.5 mm²
Conductor cross-section, flexible plus plastic
collar DIN 46228/1, further connection, max. 6 mm²
Creation date September 20, 2011 9:56:40 PM CEST
Last update 08.08.2011 / We reserve the right to make technical changes.
2
Datasheet
W-series terminal with clamping yoke connection
WSI 6
Technical data
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com
Conductors for clamping (rated connection)
Type of connection
Screw connection
Blade size
4.0 x 0.8 mm
Number of connections
2
Clamping range, rated connection, max.
10 mm²
Tightening torque, min.
0.8 Nm
Torque setting with DMS electric screwdriver 3
Conductor cross-section, solid, min.
0.5 mm²
Wire connection cross section, stranded,
rated connection, min.
1.5 mm²
Wire connection cross section, finely
stranded, max.
10 mm²
Wire connection cross section, finely
stranded with wire-end ferrules DIN 46228/1,
rated connection, min.
0.5 mm²
Cross-section for connected conductor,
finely stranded with wire-end ferrules
and plastic collars DIN 46228/4, rated
connection, min.
0.5 mm²
Wire connection cross section AWG, min.
AWG 20
Stripping length
Connection direction
Clamping range, rated connection, min.
Clamping screw
Tightening torque, max.
Gauge to IEC 60947-1
Wire connection cross section, solid core
max. rated connection
Wire connection cross section, stranded,
rated connection, max.
Conductor cross-section, flexible, min.
12 mm
on side
0.5 mm²
M 3.5
1.6 Nm
A5
500 V
Type of voltage for indicator
AC/DC
G-Si. 5 x 20
Pivoting
AC/DC
Display
Operating voltage, max.
Without LED
500 V
6 mm²
6 kV
6.3 A
3
Rated voltage to adjoining terminal
Rated current
Standards
500 V
6.3 A
IEC 60947-7-3
EC000899
EC000899
27-14-11-16
27-14-11-16
ETIM 3.0
UNSPSC
eClass 5.1
EC000899
30-21-18-11
27-14-11-16
10 mm²
10 mm²
0.5 mm²
Wire connection cross section, finely
stranded with wire-end ferrules DIN 46228/1,
rated connection, max.
6 mm²
Wire connection cross-section, finely
stranded with wire-end ferrules and plastic
collars DIN 46228/4, rated connection, max.
6 mm²
Wire connection cross section AWG, max. AWG 8
Display element
Operating voltage for display, max.
Fuse terminals
Cartridge fuse
Fuse holder (cartridge holder)
Type of voltage for indicator
Rating data
Rated cross-section
Rated impulse withstand voltage
Current at maximum wires
Pollution severity
Classifications
ETIM 2.0
ETIM 4.0
eClass 4.1
eClass 6.0
Approvals
Approvals
BURVER; CE; CSA;
DETNORVER;
GERMLLOYD; GOSTME25;
KEMAKEUR; LLOYDSREG;
MARITREG; NEMKO; RINA;
UR
Creation date September 20, 2011 9:56:40 PM CEST
Last update 08.08.2011 / We reserve the right to make technical changes.
3
Datasheet
W-series terminal with clamping yoke connection
WSI 6
Technical data
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com
Product notes
Note, ordering data
Note, technical data
Note, accessories
Product description
Max. power loss (1.6 W) at the cartridge fuse limits the rated current.
Fuse inserts or contact sleeves should be attached in the middle; variant with contact sleeve order number
1028200000 (Qty. 50/11A) wire connection H07V-K10. H07V-R10 and AWG 8/7 with 1.4 Nm tightening
torque
Screw M3 x 5 order No. 1052100000 for QL 2 - QL 10.
400V
Downloads
STEP
3D model
1011000000_09406_WSI_6_STP.stp
Creation date September 20, 2011 9:56:40 PM CEST
Last update 08.08.2011 / We reserve the right to make technical changes.
4
Datasheet
W-series terminal with clamping yoke connection
WSI 6
Drawings
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
www.weidmueller.com
Creation date September 20, 2011 9:56:40 PM CEST
Last update 08.08.2011 / We reserve the right to make technical changes.
5