0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1065020000

1065020000

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
1065020000 数据手册
    Data sheet... VSSC6 RS485 PA EX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com     Overvoltage coupling along the conductor path may disturb or destroy sensitive signal inputs. It is important to provide protection in the immediate vicinity of I&C devices. Weidmüller's broad product range for the I&C sector offers products in a 2-piece, pluggable design and modular terminals for tension clamp or screw connection. These products are suitable for both binary and analogue signals. Weidmüller also offers other designs with integrated components such as gas discharge tubes or varistors. VARITECTOR stands for flexible and variable surge protection by Weidmüller, tested according to product standard IEC61643-21. The VARITECTOR series can be used in applications according to IEC 61643-22 / VDE 0845-3 for classes C1, C2, C3 and D1. The VARITECTOR SPC, SSC and MCZ OVP product families optimally combine electrical and mechanical properties. Size and easy handling play an important role. This surge protection is suited for confined spaces in industrical and process automation as well as in building automation applications. General ordering data   Order No. Type Version GTIN (EAN) Qty.   1065020000 VSSC6 RS485 PA EX Surge protection for instrumentation and control 4032248830251 5 pc(s). Creation date April 26, 2013 10:12:36 PM CEST   Catalogue status 12.03.2013 / We reserve the right to make technical changes. 1     Data sheet... VSSC6 RS485 PA EX   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights   Width Depth   12.2 mm 81 mm     Height Net weight 88.5 mm 49.2 g 5...96 % -40 °C...+80 °C     Operating temperature   -40 °C...+70 °C 29     3,936 Years   MTTF SFF         Isolating function Optical function display Segment     No No Instrumentation and Control   Surge voltage category     94 V     12 V 35 V       Rated current 300 mA Discharge current In (8/20µs) wire-wire 2.5 kA Discharge current In (8/20µs) wire-PE 2.5 kA Discharge current, max. (8/20 µs) 10 kA Standards IEC61643-21:2009, DIN EN 60079-0.2009, DIN EN 60079-26:2007, DIN EN 61241-11:2006 Humidity 5...96 % Lightning test current Iimp (10/350 µs) 0.5 kA Residual voltage, UP typical 94 V Overload - failure mode Modus 2 Temperatures   Humidity Storage temperature   Probability of failure   λges -9 PFH in 1*10 per hour SIL in compliance with IEC 61508   1.75 3 93.97 % General data   Colour Mounting rail Protection degree UL 94 flammability rating   Light Blue TS 35 IP 20 V-0 Insulation coordination acc. to EN 50178   Pollution severity   2 III Interference voltage   Protection level on output side Wire-PE 1kV/µs, typically 94 V   Protection level   Protection level, UP wire - PE   technical data   Rated voltage (DC) Max. continuous voltage, Uc (DC) Discharge current Imax (8/20µs) wirewire Discharge current Imax (8/20µs) wire-PE Protection level UP (typ.) Colour Requirements category acc. to IEC 61643-21 Volume resistance Dielectric strength at FG against PE   5 kA 5 kA ≤ 1830 V Light Blue C2, C3, D1 1.8 Ω 10 % ≥ 500 V             Creation date April 26, 2013 10:12:36 PM CEST   Catalogue status 12.03.2013 / We reserve the right to make technical changes. 2     Data sheet... VSSC6 RS485 PA EX   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Connection data   Clamping range, rated connection, min. 0.5 mm² Wire connection cross section, stranded, rated connection, min. 0.5 mm² Tightening torque, min. 0.5 Nm         Clamping range, rated connection, max. 4 mm² Wire connection cross section, stranded, rated connection, max. 4 mm² Tightening torque, max. 0.8 Nm EX protection data   Input power, max. PI Internal inductance, max. LI 0.75 W 0 µH Temperature class T5/100°C (-40 ° C ... +85 °C) li 300 mA         Internal capacitance, max. CI Temperature class T4/135°C (-40°C ... +120 °C) li Temperature class T6/85 °C (-40 °C ... +70 °C) li 1 nF 300 mA 300 mA Further details of approvals   GOST certificate   GOST-Zertifikat     UL Zertifikat     ATEX Certificate   IEC Ex certificate IECEX Zertifikat EC000943 27-13-08-01 27-14-02-01       UNSPSC eClass 5.1 eClass 7.1 30-21-19-21 27-13-08-01 27-13-08-05 Rated data UL   UL certificate   Ratings IECEx/ATEX   ATEX certificate   Classifications   ETIM 3.0 eClass 4.1 eClass 6.2   Approvals   Approvals ROHS   Conform Probability of failure   SIL PAPER 3-D model SIL Paper   Downloads   Package insert Declaration of Conformity PDF 3-D model Instruction sheet VSSC K378_02_11.pdf Type examination certificate   Creation date April 26, 2013 10:12:36 PM CEST   Catalogue status 12.03.2013 / We reserve the right to make technical changes. 3     Data sheet... VSSC6 RS485 PA EX   Drawings Similar to illustration Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Circuit diagram Creation date April 26, 2013 10:12:36 PM CEST   Catalogue status 12.03.2013 / We reserve the right to make technical changes. 4
1065020000 价格&库存

很抱歉,暂时无法提供与“1065020000”相匹配的价格&库存,您可以联系我们找货

免费人工找货