Data sheet
TERMSERIES
TRZ 24-230VUC 1CO AU
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
TERMSERIES relay module, complete modules consisting
of
a relay and a base with AC/DC/UC coils,
available in different versions:
• With screw and tension-clamp connection
• AgNi contact, optionally with hard gold-plated contacts
• 1 and 2 COs
• Optionally with multiple-voltage input: 24...230 V UC
• With various protective circuits
in the input (free-wheel diode, RC element)
• Illuminated ejection lever
General ordering data
Type
Order No.
Version
GTIN (EAN)
Qty.
TRZ 24-230VUC 1CO AU
1123210000
TERMSERIES, Relay module, No. of contacts: 1
CO contact AgNi 5µm Au, Rated control voltage:
24…230 V UC ±10 %, Continuous current: 6 A,
Tension clamp connection
4032248905027
10 pc(s).
Creation date April 13, 2018 10:12:41 PM CEST
Catalogue status 06.04.2018 / We reserve the right to make technical changes.
1
Data sheet
TERMSERIES
TRZ 24-230VUC 1CO AU
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Dimensions and weights
Width
Height
Depth
Net weight
6.4 mm
90.5 mm
87.8 mm
31.6 g
Width (inches)
Height (inches)
Depth (inches)
5–95% rel. humidity, Tu =
40°C, no condensation
-40 °C
-40 °C
-40 °C...85 °C
Operating temperature, max.
Storage temperature, max.
Operating temperature
Rated current AC
0.252 inch
3.563 inch
3.457 inch
Temperatures
Humidity
Operating temperature, min.
Storage temperature, min.
Storage temperature
60 °C
85 °C
-40 °C...60 °C
Input
Rated control voltage
24...230 V UC ± 10 %
22 mA @ 24 V DC ±10 %
Pull-in/drop-out voltage, typ.
13 V / 7 V AC
13 V / 5 V DC
Status indicator
Green LED
Coil voltage of the replacement relay
deviating from the rated control voltage Yes
Rated current DC
Power rating
Pull-in/drop-out current, typ.
Protective circuit
Coil voltage of the replacement relay
4 mA @ 230 V AC ±10 %,
28 mA @ 24 V AC ±10 %
530 mW @ 24 V DC,
930 mVA @ 230 V AC
28.5 mA / 11 mA AC
23 mA / 6.5 mA DC
Rectifier
24 V DC
Output
Rated switching voltage
Max. switching voltage, DC
Inrush current
DC switching capacity (resistive), max.
Switch-off delay
Max. switching frequency at rated load
250 V AC
250 V
20 A / 20 ms
144 W @ 24 V
< 140 ms
0.1 Hz
Max. switching voltage, AC
Continuous current
AC switching capacity (resistive), max.
Switch-on delay
Min. switching power
1 CO contact (AgNi 5µm
Au)
Mechanical service life
TS 35
No
Test button
UL 94 flammability rating
300 V
2
Surge voltage category
III
Protection degree
IP20
Creepage and clearance distance input –
output
≥ 5.5 mm
Dielectric strength to mounting rail
4 kVeff / 1 min.
250 V
6A
1500 VA
≤ 30 ms
1 mA @ 1 V
Contact data
Contact type
5 x 106 switching cycles
General data
Mounting rail
Mechanical switch position indicator
No
V-0
Insulation coordination
Rated voltage
Pollution severity
Dielectric strength input – output
Dielectric strength of open contact
Impulse withstand voltage
4 kVeff / 1 min.
1 kVeff / 1 min
6 kV (1.2/50 µs)
Creation date April 13, 2018 10:12:41 PM CEST
Catalogue status 06.04.2018 / We reserve the right to make technical changes.
2
Data sheet
TERMSERIES
TRZ 24-230VUC 1CO AU
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Further details of approvals / standards
Standards
Certificate no. (cULus)
EN 50178, EN 55011, EN
61000-6-1, 2, 4
E141197
Certificate No. (DNVGL)
TAA00001E5
Connection data
Wire connection method
Clamping range, rated connection
Clamping range, max.
Tension clamp connection
1.5 mm²
2.5 mm²
Wire connection cross section AWG,
max.
AWG 14
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely
stranded, max.
2.5 mm²
Wire cross-section, finely stranded, max.
(AWG)
AWG 14
Wire connection cross-section, finely
stranded with wire-end ferrules DIN
46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH
(DIN 46228-1), max.
1.5 mm²
Twin wire-end ferrules, max.
1 mm²
Gauge to IEC 60947-1
A1, B1
Stripping length, rated connection
Clamping range, min.
Wire connection cross section AWG,
min.
Wire cross-section, solid, min.
8 mm
0.14 mm²
Connection cross-section AWG, min.
Type of conductor
AWG 26
rigid copper conductor,
flexible copper conductor
ETIM 6.0
eClass 7.1
eClass 9.0
AWG 26
0.14 mm²
Wire connection cross-section, finely
stranded, min.
0.14 mm²
Wire cross-section, finely stranded, min.
(AWG)
AWG 26
Wire connection cross-section, finely
stranded with wire-end ferrules DIN
46228/4, min.
0.14 mm²
Conductor cross-section, flexible, AEH
(DIN 46228-1), min.
0.14 mm²
Twin wire-end ferrules, min.
0.5 mm²
Blade size
0.6 x 3.5 mm
Rated data UL
Ambient temperature (operational), max. 40 °C
Connection cross-section AWG, max.
AWG 14
Pollution severity level
2
Classifications
ETIM 5.0
eClass 6.2
eClass 8.1
eClass 9.1
EC001437
27-37-16-01
27-37-16-01
27-37-16-01
EC001437
27-37-16-01
27-37-16-01
Product information
Descriptive text ordering data
Descriptive text technical data
Spare relay
Type: RSS112024
Orderno.: 4061590000
Accessories and dimensional drawings: refer to the TERMSERIES
Accessories page.
Creation date April 13, 2018 10:12:41 PM CEST
Catalogue status 06.04.2018 / We reserve the right to make technical changes.
3
Data sheet
TERMSERIES
TRZ 24-230VUC 1CO AU
Technical data
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Approvals
Approvals
ROHS
Conform
Downloads
Approval/Certificate/Document of
Conformity
Brochure/Catalogue
Engineering Data
Engineering Data
User Documentation
DE_PA5600_160229_001.pdf
CAT 4.2 ELECTR 15/16 EN
EPLAN, WSCAD, Zuken E3.S
STEP
Operating Instructions
Creation date April 13, 2018 10:12:41 PM CEST
Catalogue status 06.04.2018 / We reserve the right to make technical changes.
4
Data sheet
TERMSERIES
TRZ 24-230VUC 1CO AU
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Drawings
Wiring diagram
Graph
Graph
DC load limit curve
Resistive load
Dimensional drawing
Electrical service life230 V AC resistive load
230 V AC resistive load
Creation date April 13, 2018 10:12:41 PM CEST
Catalogue status 06.04.2018 / We reserve the right to make technical changes.
5
Data sheet
TERMSERIES
TRZ 24-230VUC 1CO AU
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Drawings
Miscellaneous
Type codes
Creation date April 13, 2018 10:12:41 PM CEST
Catalogue status 06.04.2018 / We reserve the right to make technical changes.
6