0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1478110000

1478110000

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 24V 120W

  • 数据手册
  • 价格&库存
1478110000 数据手册
    Data sheet PROmax PRO MAX 120W 24V 5A Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com     PROmax offers diverse solutions for demanding automation. Our high performance and durable PROmax switchmode power supply units are designed for especially demanding requirements. PROmax reliably copes with continuous overload of up to 20% or short-term peak loads of 300% occurring with high control cabinet temperatures. High boost capability and full power are also made possible in a wide temperature range. Our switch-mode power supply units can be used around the world and are also suitable for confined spaces thanks to their low width. Together with our uninterruptible DC USPs, the diode modules or CAP modules, you can create a power supply solution that is tailored to your requirements. General ordering data   Type Order No. Version GTIN (EAN) Qty.   PRO MAX 120W 24V 5A 1478110000 Power supply, switch-mode power supply unit, 24 V 4050118285956 1 pc(s). Creation date February 7, 2018 7:41:04 PM CET   Catalogue status 26.01.2018 / We reserve the right to make technical changes. 1     Data sheet PROmax PRO MAX 120W 24V 5A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights   Width Height Depth Net weight   40 mm 130 mm 125 mm 859 g         Width (inches) Height (inches) Depth (inches)   1.575 inch 5.118 inch 4.921 inch 5...95 %, no condensation     -40 °C...85 °C Operating temperature   -25 °C...70 °C   AC input voltage range   DC current consumption       Frequency range AC Inrush current Recommended back-up fuse       Continuous output current @ URated     Output voltage Parallel connection option Temperatures   Humidity at operating temperature Storage temperature   Input   AC current consumption Connection system DC input voltage range Input fuse (internal) Rated input voltage Standby power consumption, max.   1A @ 230 VAC / 2,5A @ 115 VAC Screw connection 80...370 V DC Yes 100...240 V AC (widerange input) 1W 85…277 V AC 1,5A @ 370 VDC / 2,5A @ 120 VDC 45…65 Hz max. 15 A 6 A, Char. B, circuit breaker, 6 A, char. C circuit breaker output   Connection system Output power Output voltage Power reserve at nom. voltage Pulsed current capacity @ URated Rated output voltage   Screw connection 120 W 22.5...29.5 V (adjustable via potentiometer) 6 A (1 min), 7.5 A (4s) 15 A (2ms) 24 V DC ± 1 % 6.0 A @ 45 °C, 3,75 A @ 70 °C 24 V       yes, max. 5 Protection against inverse voltage Yes Rated (nominal) output current @ UNom 5 A @ 60 °C Residual ripple, breaking spikes < 50 mVss @ UNenn, Full Load         Current limiting Derating Housing version Mounting position, installation notice       Power factor (approx.) Power loss, nominal load Protection degree     Short-circuit protection Status indication     General data   AC failure bridging time @ INom Degree of efficiency Earth leakage current, max. MTBF min. 20 ms 89% 3.5 mA >500.000h (25°C, IEC 61709) -25 °C...70 °C 1.2 W Operating temperature Power loss, idling Protection against reverse voltages from the load 30…35 V DC Series switching capability Yes Start-up Surge voltage category   ≥ -40 °C III > 120 % IN > 60°C / 75% @ 70°C Metal, corrosion resistant Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between. > 0.90 @ 230 V AC 14.8 W IP20 Yes LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED red, relay off) Creation date February 7, 2018 7:41:04 PM CET   Catalogue status 26.01.2018 / We reserve the right to make technical changes. 2     Data sheet PROmax PRO MAX 120W 24V 5A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data EMC / shock / vibration   Vibration resistance IEC 60068-2-6 Shock resistance IEC 60068-2-27     Interference immunity test acc. to 2.3 g 30 g in all directions     I, with PE connection 3.5 kV 4 kV III         Humidity at operating temperature Insulation voltage output / earth Pollution severity   5...95 %, no condensation 0.5 kV 2   For use with electronic equipment   Protective separation / protection against electrical shock Safety transformers for switch-mode power supplies Acc. to EN50178 / VDE0160 VDE0100-410 / acc. to DIN57100-410 EN 55024, EN 55022, IEC61000-3-2,-3, IEC61000-4-2,-3,-4,-5,-6,-8,-11 Insulation coordination   Class of protection Insulation voltage input / earth Insulation voltage, input/output Surge voltage category   Electrical safety (applied standards)   Electrical machine equipment Protection against dangerous shock currents Safety extra-low voltage   Acc. to EN60204 Acc. to VDE0106-101 SELV acc. to EN60950, PELV acc. to EN60204, IEC61204   nach EN61558-2-16 Connection data (input)   Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, max. Wire connection cross section, flexible (input), max.   10 0.22 mm² 0.18 mm² 3 for L/N/PE 0.6 Nm 4 mm²   Conductor cross-section, AWG/kcmil , min. Conductor cross-section, rigid , max. Connection system Screwdriver blade Tightening torque, min.   26 6 mm² Screw connection 0.8 x 4.0, PZ 1 0.5 Nm           Conductor cross-section, AWG/kcmil , min. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, max.   26 0.5 mm² 0.5 mm² 8 (++,---,11,13,14) 0.6 Nm     Floating contact             Connection data (output)   Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , max. Conductor cross-section, rigid , max. Connection system Screwdriver blade Tightening torque, min.   12 4 mm² 6 mm² Screw connection 0.6 x 3.5 0.5 Nm   Signalling   Contact load (NO contact) Status indication   max. 30 V DC / 1 A LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED red, relay off) Yes Creation date February 7, 2018 7:41:04 PM CET   Catalogue status 26.01.2018 / We reserve the right to make technical changes. 3     Data sheet PROmax PRO MAX 120W 24V 5A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Approvals   Institute (GERMLLOYD)   Certificate No. (GERMLLOYD) Institute (cULus)   Certificate no. (cULus) Institute (cULusEX)   Certificate no. (cULusEX) Institute (cURus)   Certificate No. (cURus) TAA00000TT E258476 E470829 E255651   Classifications   ETIM 5.0 eClass 6.2 eClass 8.1 eClass 9.1   EC002541 27-04-90-04 27-04-90-04 27-04-07-01         ETIM 6.0 eClass 7.1 eClass 9.0   EC002540 27-04-90-04 27-04-07-03 Product information   Descriptive text ordering data   The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Approvals   Approvals ROHS   Conform Downloads   Approval/Certificate/Document of Conformity Brochure/Catalogue Engineering Data User Documentation   DE_PA5200_160310_001.pdf CAT 4.3 ELECTR 15/16 EN EPLAN, WSCAD, Zuken E3.S Operating instructions Creation date February 7, 2018 7:41:04 PM CET   Catalogue status 26.01.2018 / We reserve the right to make technical changes. 4     Data sheet PROmax PRO MAX 120W 24V 5A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Drawings Electric symbol Derating curve Derating curve Creation date February 7, 2018 7:41:04 PM CET   Catalogue status 26.01.2018 / We reserve the right to make technical changes. 5
1478110000 价格&库存

很抱歉,暂时无法提供与“1478110000”相匹配的价格&库存,您可以联系我们找货

免费人工找货