0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2439420000

2439420000

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

  • 描述:

    1 接线板 - 面板安装螺栓/螺丝夹 - 导线入口 90° 至面板 灰色

  • 数据手册
  • 价格&库存
2439420000 数据手册
    Data sheet WGK 10 VP/Z GY BX Weidmüller Interfaces GmbH & Co. KG Postfach 3030 32760 Detmold Tel.    +49 5231 14-0     Fax.    +49 5231 14-2083 info@weidmueller.com Product image www.weidmueller.com Similar to illustration The V versions of the WGK feed-through terminals with an insulated housing and clamping yoke connections on the external side, and a solder connection on the internal side for use in encapsulated devices (e.g. EMC filters). General ordering data   Version Order No. Type GTIN (EAN) Qty. Product data Packaging   OMNIMATE Power - series WGK, Feed-through terminal, Rated cross-section: 10 mm², Wemid (PA), Feed-through (bushing) 2439420000 WGK 10 VP/Z GY BX 4050118468052 50 pc(s). IEC: 500 V / 57 A / 0.5 - 16 mm² UL: 300 V / 65 A / AWG 24 - AWG 6 Box Creation date May 9, 2023 7:11:39 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 1     Data sheet WGK 10 VP/Z GY BX Weidmüller Interfaces GmbH & Co. KG Postfach 3030   32760 Detmold Technical data Tel.    +49 5231 14-0 Fax.    +49 5231 14-2083 Dimensions and weights   Net weight   info@weidmueller.com 13 g     -50 °C   Operating temperature, max. OMNIMATE Power - series WGK 180° 0.8 x 4.0 2.4 Nm   Wire connection method           Fitted by customer Tightening torque, min. Clamping screw Touch-safe protection acc. to DIN VDE 0470               Colour UL 94 flammability rating Contact surface Storage temperature, max. Operating temperature, max. Temperature range, installation, max. www.weidmueller.com Temperatures   Operating temperature, min.   120 °C System parameters   Product family Conductor outlet direction Screwdriver blade Tightening torque, max. Stripping length Protection degree   11 mm IP20 Screw / solder connection Yes 1.2 Nm M4 IP 20 Material data   Insulating material Colour chart (similar) Contact material Storage temperature, min. Operating temperature, min. Temperature range, installation, min.   Wemid (PA) RAL 7035 E-Cu -40 °C -50 °C -25 °C grey V-0 tinned 70 °C 120 °C 120 °C Conductors suitable for connection   Clamping range, min. Clamping range, max. Wire connection cross section AWG, min. Wire connection cross section AWG, max. Solid, min. H05(07) V-U Solid, max. H05(07) V-U Stranded, min. H07V-R Stranded, max. H07V-R Flexible, min. H05(07) V-K Flexible, max. H05(07) V-K w. wire end ferrule, DIN 46228 pt 1, min. w. wire end ferrule, DIN 46228 pt 1, max. 0.5 mm² 16 mm² AWG 24 AWG 6 0.5 mm² 16 mm² 10 mm² 16 mm² 0.5 mm² 10 mm² 0.5 mm² 10 mm² Creation date May 9, 2023 7:11:39 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 2     Data sheet WGK 10 VP/Z GY BX Weidmüller Interfaces GmbH & Co. KG Postfach 3030   Technical data Clampable conductor Reference text   32760 Detmold Tel.    +49 5231 14-0 Fax.    +49 5231 14-2083 Type fine-wired info@weidmueller.com nominal 0.5 mm² Stripping length nominal 10 mm wire end ferrule www.weidmueller.com Recommended wire- H0,5/10 end ferrule Type fine-wired Cross-section for conductor connection nominal 0.75 mm² Stripping length nominal 10 mm wire end ferrule Recommended wire- H0,75/10 end ferrule Type fine-wired Cross-section for conductor connection nominal 1 mm² Stripping length nominal 10 mm wire end ferrule Recommended wire- H1,0/10 end ferrule Length of ferrules is to be chosen depending on the product and the rated voltage., The outside diameter of the plastic collar should not be larger than the pitch (P) Cross-section for conductor connection Rated data acc. to IEC   tested acc. to standard     Rated current, min. number of poles (Tu=20°C) Rated voltage for surge voltage class / pollution degree III/3           Rated voltage (Use group C / CSA) Rated current (Use group B / CSA) Rated current (Use group D / CSA) Wire cross-section, AWG, max.   Certificate No. (cURus) 300 V 300 V 65 A AWG 24 Specifications are maximum values, details see approval certificate.           Rated voltage (Use group C / UL 1059) Rated current (Use group B / UL 1059) Rated current (Use group D / UL 1059) Wire cross-section, AWG, max.   Box 120 mm     VPE length VPE height IEC 60664-1 Rated current, max. number of poles (Tu=20°C) 57 A Rated impulse voltage for surge voltage class/ contamination degree III/3 6 kV   57 A 500 V   Rated data acc. to CSA   Rated voltage (Use group B / CSA) Rated voltage (Use group D / CSA) Rated current (Use group C / CSA) Wire cross-section, AWG, min.   300 V 300 V 65 A AWG 24 300 V 65 A 10 A AWG 6 Rated data acc. to UL 1059   Institute (cURus) Rated voltage (Use group B / UL 1059) Rated voltage (Use group D / UL 1059) Rated current (Use group C / UL 1059) Wire cross-section, AWG, min. Reference to approval values   E60693 300 V 65 A 10 A AWG 6 Packing   Packaging VPE width   195 mm 75 mm Creation date May 9, 2023 7:11:39 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 3     Data sheet WGK 10 VP/Z GY BX Weidmüller Interfaces GmbH & Co. KG Postfach 3030   32760 Detmold Technical data Tel.    +49 5231 14-0 Fax.    +49 5231 14-2083 Classifications   ETIM 6.0 ETIM 8.0 ECLASS 9.1 ECLASS 11.0   info@weidmueller.com EC001283 EC001283 27-14-11-34 27-14-11-34         ETIM 7.0 ECLASS 9.0 ECLASS 10.0 ECLASS 12.0 EC001283 www.weidmueller.com 27-14-11-34 27-14-11-34 27-14-11-34 Important note   Notes • Clearance and creepage distances to other components must be devised in accordance with the relevant application standard. This can be achieved in the device by full encapsulation or by the use of additional spacer plates. • Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. • Colours: SW = black; GN/YL = green/yellow; GY = grey • Additional variants on request • WGK: Rated voltage plastic walls: 1 - 4 mm = 500 V; metal walls: 1 - 2.5 mm = 400 V; metal walls: 2.5 4 mm = 250 V   • Long term storage of the product with average temperature of 50 °C and average humidity 70%, 36 months Approvals   Approvals ROHS UL File Number Search Certificate No. (cURus)   Conform UL Website E60693 Downloads   Approval/Certificate/Document of Conformity Engineering Data Product Change Notification Catalogues Brochures   Declaration of the Manufacturer CAD data -- STEP 20220114 Change color for feedthrough terminals – WGK GY 20220114 WGK GY - Farbänderung Catalogues in PDF-format FL DRIVES EN MB DEVICE MANUF. EN FL DRIVES DE FL_BASE_STATION_EN FL ELEVATOR EN FL POWER SUPPLY EN FL 72H SAMPLE SER EN PO OMNIMATE EN Creation date May 9, 2023 7:11:39 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 4     Data sheet WGK 10 VP/Z GY BX Weidmüller Interfaces GmbH & Co. KG Postfach 3030   Drawings Dimensional drawing 32760 Detmold Tel.    +49 5231 14-0 Fax.    +49 5231 14-2083 info@weidmueller.com www.weidmueller.com Derating curve Creation date May 9, 2023 7:11:39 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 5
2439420000 价格&库存

很抱歉,暂时无法提供与“2439420000”相匹配的价格&库存,您可以联系我们找货

免费人工找货