0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2466910000

2466910000

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 12V 120W

  • 数据手册
  • 价格&库存
2466910000 数据手册
    Data sheet PROtop PRO TOP1 120W 12V 10A Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com     High-end power supplies must perform efficiently and reliably, even in challenging industrial environments. This requires high power reserves, a long service life and optimal protection against overvoltage, vibration and extreme temperature conditions. New DCL technology gives PROtop an outstanding dynamic range. This can be used for the reliable triggering of circuit breakers or for powerful motor starts. General ordering data   Type Order No. Version GTIN (EAN) Qty.   PRO TOP1 120W 12V 10A 2466910000 Power supply, switch-mode power supply unit, 12 V 4050118481495 1 pc(s). Creation date December 27, 2018 6:28:26 PM CET   Catalogue status 07.12.2018 / We reserve the right to make technical changes. 1     Data sheet PROtop PRO TOP1 120W 12V 10A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights   Width Height Depth Net weight   35 mm 130 mm 125 mm 850 g         Width (inches) Height (inches) Depth (inches)   1.378 inch 5.118 inch 4.921 inch 5...95 %, no condensation -25 °C -40 °C -40 °C...85 °C         Operating temperature, max. Storage temperature, max. Operating temperature   70 °C 85 °C -25 °C...70 °C Lead 7439-92-1     85…277 V AC 80 ... 410 V DC 45…65 Hz         Connection system Dielectric strength Input fuse (internal) Rated input voltage       Connection system   Output power         Output voltage Protection against inverse voltage Rated (nominal) output current @ UNom Reserve capacity @ URated   Triggerable circuit breakers Temperatures   Humidity at operating temperature Operating temperature, min. Storage temperature, min. Storage temperature   Environmental Product Compliance   REACH SVHC   Input   AC input voltage range DC input voltage range Frequency range AC Inrush current Surge protection   max. 5 A Varistor PUSH IN with actuator max. 300 V AC ≤ 15 s Yes 100 - 240 V AC / 120 340 V DC output   DCL - peak load reserve Mains failure bridge-over time Output voltage Parallel connection option Ramp-up time Rated output voltage Residual ripple, breaking spikes   150 % (5 s); 400 % (15 ms) > 20 ms @ 115V AC/ 230 VAC 12 V Passive Current Sharing ≤ 100 ms 12 V DC ± 1 % < 50 mVss @ UNenn, Full Load PUSH IN with actuator 120 W 11...15 V Yes 10 A @ 60 °C 130% permanent at ≤ 40°C B6, C2 Creation date December 27, 2018 6:28:26 PM CET   Catalogue status 07.12.2018 / We reserve the right to make technical changes. 2     Data sheet PROtop PRO TOP1 120W 12V 10A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data General data   AC failure bridging time @ INom Derating Housing version Mounting position, installation notice Power factor (approx.) Power loss, nominal load Series switching capability Surge voltage category   > 20 ms @ 230 V AC / > 20 ms @ 115 V AC > 60°C (2.5% / 1°C) Metal, corrosion resistant Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring active subassemblies with full load, 5 mm with passive neighbouring subassemblies, direct row mounting with 90% rated load > 0.85 13.3 W Yes III   Degree of efficiency     Earth leakage current, max. MTBF   Operating temperature         Power loss, idling Protection degree Short-circuit protection     Vibration resistance IEC 60068-2-6   Shock resistance IEC 60068-2-27 90% 3.5 mA > 1.000.000 h according IEC 1709 (SN29500) -25 °C...70 °C 5W IP20 Yes, internal EMC / shock / vibration   Noise emission in accordance with EN55032 Interference immunity test acc. to   Class B EN 55032:2015, EN 55024:2010/A1:2015, EN 55035:2017, EN 61000-3-2:2014, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-3:2007/ A1:2011, EN 61000-6-4:2007/ A1:2011 2.3 g (on DIN rail), 4 g (with direct mounting) 30 g in all directions Insulation coordination   Class of protection Insulation voltage input / earth Insulation voltage, input/output Surge voltage category   I, with PE connection 4 kV 4 kV III         Humidity at operating temperature Insulation voltage output / earth Pollution severity   5...95 %, no condensation 0.5 kV 2   For use with electronic equipment   Protective separation / protection against electrical shock Safety transformers for switch-mode power supplies Acc. to EN50178 / VDE0160 VDE0100-410 / acc. to DIN57100-410 Electrical safety (applied standards)   Electrical machine equipment Protection against dangerous shock currents Safety extra-low voltage   Acc. to EN60204 Acc. to VDE0106-101 SELV acc. to EN60950, PELV acc. to EN60204   nach EN61558-2-16 Creation date December 27, 2018 6:28:26 PM CET   Catalogue status 07.12.2018 / We reserve the right to make technical changes. 3     Data sheet PROtop PRO TOP1 120W 12V 10A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Connection data (input)   Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Wire connection cross section, flexible (input), max.   12 0.5 mm² 0.5 mm² 3 for L/N/PE 2.5 mm²           Conductor cross-section, AWG/kcmil , min. Conductor cross-section, rigid , max. Connection system Screwdriver blade   20 1.5 mm² PUSH IN with actuator 0.6 x 3.5 Conductor cross-section, AWG/kcmil , min. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals   26 0.2 mm² 0.2 mm² 5 (+ + / - - -) Wire connection cross-section, flexible (signal), min. Wire cross-section, AWG/kcmil , max. Wire cross-section, solid , max.   0.14 mm² 16 1.5 mm² Connection data (output)   Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , max. Conductor cross-section, rigid , max. Connection system Screwdriver blade   12 2.5 mm² 2.5 mm² PUSH IN with actuator 0.6 x 3.5           Connection data (signal)   Wire connection cross-section, flexible (signal), max. Wire connection method Wire cross-section, AWG/kcmil , min. Wire cross-section, solid , min.   1.5 mm² PUSH IN 26 0.14 mm²         Signalling   LED green/red   Green: Operation (failure-   free), Flashing green: advance warning I>90%, Green/red flashing: output switched off (switchoff mode), Flashing red: overload/error   Classifications   ETIM 6.0 eClass 9.1   EC002540 27-04-07-01     eClass 6.2   27-04-90-04 Product information   Descriptive text ordering data   Current technical data at catalog.weidmueller.com Approvals   ROHS   Conform Downloads   Approval/Certificate/Document of Conformity Engineering Data Engineering Data User Documentation   Declaration of Conformity EPLAN STEP IS PRO TOP1 120W 12V 10A Operating instructions Creation date December 27, 2018 6:28:26 PM CET   Catalogue status 07.12.2018 / We reserve the right to make technical changes. 4     Data sheet PROtop PRO TOP1 120W 12V 10A   Drawings Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Creation date December 27, 2018 6:28:26 PM CET   Catalogue status 07.12.2018 / We reserve the right to make technical changes. 5
2466910000 价格&库存

很抱歉,暂时无法提供与“2466910000”相匹配的价格&库存,您可以联系我们找货

免费人工找货