0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2618040000

2618040000

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

  • 描述:

    通用 继电器 SPDT(1 Form C) 12VDC 线圈 DIN 轨道

  • 数据手册
  • 价格&库存
2618040000 数据手册
    Data sheet TRP 12VDC 1CO 16A Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com     Product image Similar to illustration • 1 CO contact • Contact material: AgNi • Unique multi-voltage input from 24 to 230 V UC • Input voltages from 5 V DC to 230 V UC with coloured marking: AC: red, DC: blue, UC: white General ordering data   Version Order No. Type GTIN (EAN) Qty.   TERMSERIES, Relay module, Number of contacts: 1, CO contact AgNi, Rated control voltage: 12 V DC ±20 %, Continuous current: 16 A, PUSH IN, Test button available: No 2618040000 TRP 12VDC 1CO 16A 4050118670790 10 pc(s). Creation date May 9, 2023 7:32:48 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 1     Data sheet TRP 12VDC 1CO 16A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Technical data Dimensions and weights   Depth Height Width Net weight   87.8 mm 89.4 mm 12.8 mm 58 g         Depth (inches) Height (inches) Width (inches)   3.457 inch 3.52 inch 0.504 inch -40 °C...85 °C -40 °C 5-95% relative humidity, Tu = 40°C, without condensation       Operating temperature Operating temperature, max.   -40 °C...60 °C 60 °C     Connection cross-section AWG, min. Type of conductor     AWG 26 rigid copper conductor, flexible copper conductor Temperatures   Storage temperature Operating temperature, min. Humidity   Rated data UL   Ambient temperature (operational), max. 60 °C Connection cross-section AWG, max. AWG 14 Pollution severity level 2   Control side   Rated control voltage Power rating Pull-in/drop-out current, typ. Protective circuit Coil voltage of the replacement relay     12 V DC ±20 %   420 mW   21 mA / 5 mA DC   Free-wheeling diode, Reverse polarity protection   12 V DC Rated current DC Pull-in/drop-out voltage, typ. Status indicator Coil voltage of the replacement relay deviating from the rated control voltage   33.3 mA 8 V / 3 V DC Green LED Continuous current Max. switching voltage, DC AC switching capacity (resistive), max. Switch-on delay Contact type Min. switching power 16 A 250 V 4000 VA ≤ 11 ms 1 CO contact (AgNi) 10 mA @ 10 V, 100 mA @ 5V No Load side   Rated switching voltage Max. switching frequency at rated load Inrush current DC switching capacity (resistive), max. Switch-off delay Mechanical service life   250 V AC 0.1 Hz 30 A / 4 s 384 W @ 24 V ≤ 8 ms 30 x 106 switching cycles             General data   Operating altitude Rail Test button available Mechanical switch position indicator Colour UL94 flammability rating component   ≤ 2000 m, above sea level TS 35 No No black Component UL94 flammability rating Component UL94 flammability rating Component UL94 flammability rating Housing V-0 Retaining clip V-0 Pusher V-0 Creation date May 9, 2023 7:32:48 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 2     Data sheet TRP 12VDC 1CO 16A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Technical data Insulation coordination   Rated voltage Surge voltage category 300 V       Pollution severity Clearance and creepage distances for control side - load side Type of isolation at input and output     Dielectric strength to mounting rail Protection degree E141197     PUSH IN 1.5 mm²       Stripping length, rated connection Clamping range, min. Wire connection cross section AWG, min. Wire cross-section, solid, min. III Dielectric strength for control side - load 1.2 kVeff / 5 s side Dielectric strength of open contact 1 kVeff / 1 min Impulse withstand voltage 6 kV (1.2/50 µs)   2 ≥ 6 mm reinforced insulation 4 kVeff / 1 Min. IP20 Further details of approvals / standards   Certificate no. (cULus)   Connection data   Wire connection method Clamping range, rated connection Clamping range, max. Wire connection cross section AWG, max. Wire cross-section, solid, max. Wire cross-section, solid, max. (AWG) 2.5 mm² AWG 14 1.5 mm² AWG 16 Wire connection cross section, finely stranded, max. 2.5 mm² Wire cross-section, finely stranded, max. (AWG) AWG 14 Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 1.5 mm² Conductor cross-section, flexible, AEH (DIN 46228-1), max. 1.5 mm² Twin wire-end ferrules, max. 1 mm²             Wire cross-section, solid, min. (AWG) Wire connection cross section, finely stranded, min. Wire cross-section, finely stranded, min. (AWG) Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. Conductor cross-section, flexible, AEH (DIN 46228-1), min. 9 mm 0.14 mm² AWG 26 0.14 mm² AWG 26 0.14 mm² AWG 26 0.14 mm² 0.14 mm²   Twin wire-end ferrules, min.   Blade size 0.5 mm² 0.4 x 2.0 mm         ETIM 7.0 ECLASS 9.0 ECLASS 10.0 ECLASS 12.0 EC001437 27-37-16-01 27-37-16-01 27-37-16-01   Classifications   ETIM 6.0 ETIM 8.0 ECLASS 9.1 ECLASS 11.0   EC001437 EC001437 27-37-16-01 27-37-16-01 Environmental Product Compliance   REACH SVHC SCIP   Lead 7439-92-1 9e2cbc49-76d9-4611-b8ec-5b4f549a0aa9 Creation date May 9, 2023 7:32:48 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 3     Data sheet TRP 12VDC 1CO 16A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Technical data Approvals   Approvals ROHS UL File Number Search Certificate no. (cULus)   Conform UL Website E141197 Downloads   Approval/Certificate/Document of Conformity Engineering Data User Documentation Catalogues   EU Konformitätserklärung / EU Declaration of Conformity CAD data -- STEP Beipackzettel / Package Insert – multilingual Catalogues in PDF-format Creation date May 9, 2023 7:32:48 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 4     Data sheet TRP 12VDC 1CO 16A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Drawings Wiring diagram Graph Graph DC load limit curve Resistive load Dimensional drawing Electrical service life230 V AC resistive load 230 V AC resistive load Creation date May 9, 2023 7:32:48 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 5     Data sheet TRP 12VDC 1CO 16A   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Drawings Miscellaneous Type codes Creation date May 9, 2023 7:32:48 PM CEST   Catalogue status 28.04.2023 / We reserve the right to make technical changes. 6
2618040000 价格&库存

很抱歉,暂时无法提供与“2618040000”相匹配的价格&库存,您可以联系我们找货

免费人工找货