0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2730460000

2730460000

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

  • 描述:

    SURGE PROTECTION - OVP

  • 数据手册
  • 价格&库存
2730460000 数据手册
    Data sheet VPU AC II US 1 R 120/50 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com     Abb.ähnlich • compact SPD to install in application by NFPA 79 • no additional overcurrent protection devices needed • short circuit current rating (SCCR) up to 200 kA • tested according to IEC/EN 61643-11 and UL 1449 4.Ed General ordering data   Version Order No. Type GTIN (EAN) Qty.   Surge voltage arrester, Low voltage, Surge protection, with remote contact, Single-phase, UP(L/N-PE) ≤ 1.25 kV 2730460000 VPU AC II US 1 R 120/50 4050118807646 1 pc(s). Creation date March 1, 2021 6:08:17 PM CET   Catalogue status 26.02.2021 / We reserve the right to make technical changes. 1     Data sheet VPU AC II US 1 R 120/50   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Technical data Dimensions and weights   Depth Depth including DIN rail Height (inches) Net weight Width (inches)   68 mm 76 mm 4.37 inch 132 g 0.709 inch           Depth (inches) Height Mounting dimension - height Width   2.677 inch 111 mm 75 mm 18 mm -40 °C...85 °C 5 - 95% rel. humidity     Operating temperature   -40 °C...85 °C ≤ 4000 m 120 V 200 kA SPD TYPE 1CA AWG 6 all modes AC               Ambient temperature (operational), max. 85 °C VPR (N-PE) 600 V In 20 kA Connection cross-section AWG, min. AWG 14 Ambient temperature (operational), min. -40 °C VPR (L-PE) 600 V UL Energy Networks Split-Phase     Cross-section for connected wire, solid core, max. Cross-section for connected wire, solid core, min. Stripping length   Design   Optical function display       Rail UL 94 flammability rating       Pollution severity   Temperatures   Storage temperature Humidity   Rated data UL   Operating altitude Rated Voltage UN SCCR Category Connection cross-section AWG, max. MODE Voltage type   Connection data, remote alert   Connection type Cross-section for connected wire, solid core, max. (AWG) Cross-section for connected wire, solid core, min. (AWG)   PUSH IN AWG 10 AWG 30   1.5 mm² 0.14 mm² 12 mm General data   Colour Operating altitude Protection degree Segment Version   orange, black ≤ 4000 m IP20 in installed state Power distribution Surge protection, with remote contact Installation housing, Insta IP 20 green = OK; red = arrester is defective - replace TS 35 V-0 Insulation coordination acc. to EN 50178   Operating altitude Surge voltage category   ≤ 4000 m III 2 Creation date March 1, 2021 6:08:17 PM CET   Catalogue status 26.02.2021 / We reserve the right to make technical changes. 2     Data sheet VPU AC II US 1 R 120/50   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Technical data Rated data IEC / EN   Discharge current Imax (8/20µs) wire-PE 50 kA Energy coordination (≤10 m) Type II, Type III Frequency range, max. 60 Hz Fuse No Fuse neccessary ≤315 A gG, 250 A gG @50 kA Isccr, 315 A gG @25 kA Isccr Low voltage network Single-phase Number of poles 1 Rated voltage (AC) 120 V Requirements class, acc. to EN 61643-11 T2 SPD type T2 Signalling contact 250 V 1A 1CO Temporary surge voltage (over-voltage) TOV 229 V               Discharge current In (8/20µs) wire-PE Follow-on current extinguishing capability Ifi Frequency range, min. Leakage current at Un   Max. continuous voltage, Uc (AC) Protection level UP (typ.) Requirements category acc. to IEC 61643-11 Response time     Short-circuit current rating ISCCR Standards   Voltage type           Type of connection Tightening torque, min. Clamping range, rated connection Clamping range, max. Wire connection cross section AWG, max. Wire cross-section, solid, max. Wire connection cross section, finely stranded, max. Conductor cross-section, flexible, AEH (DIN 46228-1), max. Connection cross-section, stranded, max.   20 kA Follow current need not be taken into account 50 Hz 0.3 mA 150 V ≤ 1.25 kV Type II ≤ 25 ns 50 kA IEC61643-11, EN61643-11, UL 1449 Ed.4, NFPA 79 AC Connection data   Wire connection method Screw connection Stripping length, rated connection 18 mm Tightening torque, max. 4.5 Nm Clamping range, min. 4 mm² Wire connection cross section AWG, min. AWG 14 Wire cross-section, solid, min. 2.5 mm² Wire connection cross section, finely stranded, min. 4 mm² Conductor cross-section, flexible, AEH (DIN 46228-1), min. 2.5 mm² Connection cross-section, stranded, min. 2.5 mm²           Screw connection 2 Nm 16 mm² 35 mm² AWG 6 35 mm² 35 mm² 35 mm² 35 mm² Ratings IECEx/ATEX/cUL   Certificate no. (cULus)   E354261     5 years     EC000941 27-13-08-05 27-13-08-05       ETIM 7.0 ECLASS 9.1 ECLASS 11.0 Guarantee   Time interval   Classifications   ETIM 6.0 ECLASS 9.0 ECLASS 10.0   EC000941 27-13-08-05 27-13-08-05 Creation date March 1, 2021 6:08:17 PM CET   Catalogue status 26.02.2021 / We reserve the right to make technical changes. 3     Data sheet VPU AC II US 1 R 120/50   Technical data Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Approvals   Approvals ROHS UL File Number Search   Conform E354261 Downloads   Approval/Certificate/Document of Conformity Engineering Data User Documentation   Declaration of Conformity STEP IS VPU AC II US Creation date March 1, 2021 6:08:17 PM CET   Catalogue status 26.02.2021 / We reserve the right to make technical changes. 4     Data sheet VPU AC II US 1 R 120/50   Drawings Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany   www.weidmueller.com Electric symbol Schematic circuit diagram Creation date March 1, 2021 6:08:17 PM CET   Catalogue status 26.02.2021 / We reserve the right to make technical changes. 5
2730460000 价格&库存

很抱歉,暂时无法提供与“2730460000”相匹配的价格&库存,您可以联系我们找货

免费人工找货