0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
7940099737

7940099737

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

  • 描述:

    802/115SQB LUG 90 DEGREE

  • 数据手册
  • 价格&库存
7940099737 数据手册
9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – A C Ve r s i o n Circuit Breakers Hydraulic Magnetic Type 9926 Series Double Pole Single pole and double pole versions 120/240 VAC, 50/60 Hz Up to 25A Just 13 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering Data Technical Data Voltage Current Type: Single Pole Current Ratings (amps) Part No. TS 35 0.5 1 Description Part No. TS 35 Description 9926251000 9926251001 QL-1-13-DM-KM-0.5 QL-1-13-DM-KM-01 0.5 1 9926252000 9926252001 QL-2-13-DM-KM-0.5 QL-2-13-DM-KM-01 2 9926251002 QL-1-13-DM-KM-02 2 9926252002 QL-2-13-DM-KM-02 3 4 9926251003 9926251004 QL-1-13-DM-KM-03 QL-1-13-DM-KM-04 3 4 9926252003 9926252004 QL-2-13-DM-KM-03 QL-2-13-DM-KM-04 5 6 7 9926251005 9926251006 9926251007 QL-1-13-DM-KM-05 QL-1-13-DM-KM-06 QL-1-13-DM-KM-07 5 6 7 9926252005 9926252006 9926252007 QL-2-13-DM-KM-05 QL-2-13-DM-KM-06 QL-2-13-DM-KM-07 8 10 13 15 16 9926251008 9926251010 9926251013 9926251015 9926251016 QL-1-13-DM-KM-08 QL-1-13-DM-KM-10 QL-1-13-DM-KM-13 QL-1-13-DM-KM-15 QL-1-13-DM-KM-16 8 10 13 15 16 9926252008 9926252010 9926252013 9926252015 9926252016 QL-2-13-DM-KM-08 QL-2-13-DM-KM-10 QL-2-13-DM-KM-13 QL-2-13-DM-KM-15 QL-2-13-DM-KM-16 20 25 9926251020 9926251025 QL-1-13-DM-KM-20 QL-1-13-DM-KM-25 20 25 9926252020 9926252025 QL-2-13-DM-KM-20 QL-2-13-DM-KM-25 9926 Series AC Version - dimensions in mm (in.) 120/240 VAC, 50/60Hz 0.5A 25A 66 (2.6) -40…+65°C 14AWG min., 10AWG max. 10AWG min. Although the 9926 series uses a magnetic only trip mechanism, CSA testing indicates a trip characteristic similar to thermal magnetic trip mechanisms. No de-rating is required at elevated temperatures. Additional trip curves and amp ratings are available upon request. Tripping Time 10 Seconds 1 0.1 Minutes 0.001 0.001 (%) Rated Current 4000 5000 0.4 1 0.01 4000 5000 0.6 Ambient Temperature 30°C 10 0.01 2000 2500 3000 1.5 0.1 1500 4 1 1000 28 10 400 500 125% 150% 200% 400% 600% 800% 1000% minimum 15 8 4 0.7 0.09 0.007 0.005 (sec) 10 100 105 130 150 200 Sample trip characteristics - KM Tripping Time Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 100 Ambient Temperature 30°C 1 Seconds The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Operating Characteristics Curve KM Operating Characteristics Curve 1 100 *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. 9926 Series–AC version Trip Curve 1000 1000 2000 2500 3000 9926 Series–AC version Trip Curve 1500 67101960 67101961 67101913 64.8 (2.55) 1000 Power lug, straight Power lug, 90° Lock-out handle 45 (1.77) 400 500 67101974 5 (0.2) 300 Bus-bar end cap, 2 pole 13 (0.51) 32 (1.26) Minutes Part No. 67101904 67101972 67101973 19 (0.75) 20 in.-lb 100 105 125 150 200 Torque Approval UL 489 listed, CSA C22.2 No. 5-02, CE, VDE Accessories Bus-bar (1 pole, insulated, 1 m) Bus-bar (2 pole, insulated, 1 m) Bus-bar end cap, 1 pole 90 26 (1.02) 92.8 (3.65) 10000 mechanical operations Operating temperature Wire size* 0.5-15A: 20-25A: 57 (2.24) Operating life 13 (0.51) 28.5 (1.12) 10,000A 1500V, 50/60Hz 100MM 71.4 (2.81) Interrupting capacity Dielectric strength Insulation resistance 17.9 (0.7) 74 (2.91) minimum maximum maximum 300 (sec) Type: Double Pole Current Ratings (amps) 300 • • • • • • • 9926 Series Single Pole (%) Rated Current Trip Curve 1 applies to the following part numbers where "XX" is the current rating: Single Pole— 99262512XX Double Pole— 99262522XX 3 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – A C Ve r s i o n w i t h C o n t a c t s Circuit Breakers with Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact) • AC voltages (120/240V) • Single and double pole versions • UL 489 and CSA listed • Factory fitted auxiliary or trip alarm • Compact 6.5mm width • Attached to right hand side of circuit breaker Technical Data Type: Single Pole Aux Voltage 120/240 VAC, 50/60Hz Current minimum Current Ratings (amps) Part No. 1 9926261001 2 9926261002 5 9926261005 10 9926261010 15 9926261015 20 9926261020 25 9926261025 0.5A maximum Interrupting capacity 25A 10,000A Dielectric strength Insulation resistance Operating life 1500V, 50/60Hz 100MM 10000 mechanical operations Operating temperature -40…+65°C Wire size* 0.5-15A: 20-25A: Torque 14AWG min., 10AWG max. 10AWG min. 20 in.-lb Description QL-A-1-13-DM-KM-1 QL-A-1-13-DM-KM-2 QL-A-1-13-DM-KM-5 QL-A-1-13-DM-KM-10 QL-A-1-13-DM-KM-15 QL-A-1-13-DM-KM-20 QL-A-1-13-DM-KM-25 Current Ratings (amps) Part No. 1 9926281001 2 9926281002 5 9926281005 10 9926281010 15 9926281015 20 9926281020 25 9926281025 Description QL-T-1-13-DM-KM-1 QL-T-1-13-DM-KM-2 QL-T-1-13-DM-KM-5 QL-T-1-13-DM-KM-10 QL-T-1-13-DM-KM-15 QL-T-1-13-DM-KM-20 QL-T-1-13-DM-KM-25 9926 Series Double Pole Trip (Alarm Contact) 9926 Series Double Pole w/ Auxiliary Contact Approval UL 489 listed, CSA C22.2 No. 5-02, CE, VDE Type: Single Pole Combo Type: Single Pole Trip Current Ratings (amps) Part No. 1 9926271001 2 9926271002 5 9926271005 10 9926271010 15 9926271015 20 9926271020 25 9926271025 Description QL-AT-1-13-DM-KM-1 QL-AT-1-13-DM-KM-2 QL-AT-1-13-DM-KM-5 QL-AT-1-13-DM-KM-10 QL-AT-1-13-DM-KM-15 QL-AT-1-13-DM-KM-20 QL-AT-1-13-DM-KM-25 9926 Series Double Pole Combination (Auxiliary & Alarm Contact) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Type: Double Pole Aux Current Ratings (amps) Part No. 1 9926262001 2 9926262002 5 9926262005 10 9926262010 15 9926262015 20 9926262020 25 9926262025 Type: Double Pole Trip Description QL-A-2-13-DM-KM-1 QL-A-2-13-DM-KM-2 QL-A-2-13-DM-KM-5 QL-A-2-13-DM-KM-10 QL-A-2-13-DM-KM-15 QL-A-2-13-DM-KM-20 QL-A-2-13-DM-KM-25 1000 Operating Characteristics Curve KM 9926272005 QL-T-2-13-DM-KM-5 9926272010 QL-T-2-13-DM-KM-10 9926272015 QL-T-2-13-DM-KM-15 9926272020 QL-T-2-13-DM-KM-20 9926272025 QL-T-2-13-DM-KM-25 31.3 (1.23) 26.2 (1.03) (N/O)16 (N/C)18 (C)15 Ambient Temperature 30°C TRIP ALARM Q. CONNECTORS 21.1 (0.83) 10 5.5 (0.22) 0.5 (0.02) Tripping Time Minutes 100 57.0 (2.24) 1 10 14(N/O) 21.3 (0.84) (%) Rated Current 4000 5000 2000 2500 3000 1500 1000 400 500 300 0.001 32.9 (1.3) 10.7 (0.42) 0.5 (0.02) 0.1 100 105 125 150 200 7 (0.28) 2.8 (0.11) 11(C) Seconds 12(N/C) AUX SWITCH Q. CONNECTORS 1 0.01 4 Part No. Description 9926272001 QL-T-2-13-DM-KM-1 9926272002 QL-T-2-13-DM-KM-2 Dual Mount Dimensions in mm (in.) Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC Additional trip curves and amp ratings are available upon request. Type: Double Pole Combo Current Ratings (amps) Part No. 1 9926282001 2 9926282002 5 9926282005 10 9926282010 15 9926282015 20 9926282020 25 9926282025 2 (0.08) 9926 Series–AC version Trip Curve Current Ratings (amps) 1 2 5 10 15 20 25 Description QL-AT-2-13-DM-KM-1 QL-AT-2-13-DM-KM-2 QL-AT-2-13-DM-KM-5 QL-AT-2-13-DM-KM-10 QL-AT-2-13-DM-KM-15 QL-AT-2-13-DM-KM-20 QL-AT-2-13-DM-KM-25 9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – D C Ve r s i o n Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole (80 VDC) 9926 Series Single Pole (125 VDC) • Single pole versions only • U2 trip curve for general purpose applications • 80 and 125 VDC • Up to 60A • Just 13 mm wide • Mounts on 35mm DIN-rail • UL 489A listed • VDE Type: Single Pole (80 VDC) Current Ratings (amps) 0.5 1 2 3 4 5 10 15 20 25 30 35 40 45 50 60 Accessories Part No. 9926251900 Description QY-1-13-DM-U2-0.5 9926251901 9926251902 QY-1-13-DM-U2-01 QY-1-13-DM-U2-02 9926251903 9926251904 QY-1-13-DM-U2-03 QY-1-13-DM-U2-04 9926251905 9926251910 9926251915 QY-1-13-DM-U2-05 QY-1-13-DM-U2-10 QY-1-13-DM-U2-15 9926251920 9926251925 9926251930 9926251935 9926251940 QY-1-13-DM-U2-20 QY-1-13-DM-U2-25 QY-1-13-DM-U2-30 QY-1-13-DM-U2-35 QY-1-13-DM-U2-40 9926251945 9926251950 QY-1-13-DM-U2-45 QY-1-13-DM-U2-50 9926251960 QY-1-13-DM-U2-60 9926 Series–DC version Trip Curve 9926251840 QY-1-13-DM-U2-40-B1 9926251845 9926251850 9926251860 QY-1-13-DM-U2-45-B1 QY-1-13-DM-U2-50-B1 QY-1-13-DM-U2-60-B1 74 (2.91) 66 (2.6) 13 (0.51) 92.8 (3.65) Minutes Ambient Temperature 30°C 10 1 19 (0.75) 1 32 (1.26) 0.1 5 (0.2) 45 (1.77) 64.8 (2.55) 0.01 300 0.001 100 105 130 150 200 Approval UL 489A Listed, CE, VDE Tripping Time 100 MM 10000 mechanical operations Operating temperature -40…+65°C Wire size* 1-15A: 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb QY-1-13-DM-U2-15-B1 QY-1-13-DM-U2-20-B1 QY-1-13-DM-U2-25-B1 QY-1-13-DM-U2-30-B1 QY-1-13-DM-U2-35-B1 10 Seconds Insulation resistance Operating life 9926251815 9926251820 9926251825 9926251830 9926251835 Dimensions in mm (in.) Operating Characteristics Curve U2 DC (4% Ripple Factor) 100 80,125 VDC 0.5 A 60 A 10,000 A 1500 V, 50/60 Hz QY-1-13-DM-U2-05-B1 QY-1-13-DM-U2-10-B1 Additional trip curves and amp ratings are available upon request. 1000 minimum maximum Interrupting capacity Dielectric strength 9926251805 9926251810 57 (2.24) 67101913 QY-1-13-DM-U2-02-B1 QY-1-13-DM-U2-03-B1 QY-1-13-DM-U2-04-B1 28.5 (1.12) Lock-out handle 9926251802 9926251803 9926251804 71.4 (2.81) 67101961 Description QY-1-13-DM-U2-01-B1 4000 5000 Power lug, 90° 2000 2500 3000 67101973 67101960 1500 Bus bar end cap, 1 pole Power lug, straight 1000 Part No. 67101904 Part No. 9926251801 Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 400 500 Type Bus-bar (1 pole, insulated 1m) Technical Data Voltage Current Type: Single Pole (125 VDC) Current Ratings (amps) 1 2 3 4 5 10 15 20 25 30 35 40 45 50 60 17.9 (0.7) Ordering Data (%) Rated Current *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. 5 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s Circuit Breakers Hydraulic Magnetic Type 9926 Series Single Pole 9926 Series Double Pole 9926 Series Triple Pole • AC Voltages 240/480V • Trip curve 2 for general purpose applications • UL 1077 recognized • VDE, CSA, and CE Approved • Just 13 mm wide • Mounts to 35 mm DIN-rail • Factory fitted auxiliary or trip alarm • Single, double and triple pole versions Ordering Data Type: Single Pole Current Ratings (amps) 1 2 3 4 5 6 8 10 15 20 25 35 40 50 60 Accessories Part No. Description 9926251501 QZ-1-13-D-2-01 9926251502 9926251503 QZ-1-13-D-2-02 QZ-1-13-D-2-03 9926251504 9926251505 QZ-1-13-D-2-04 QZ-1-13-D-2-05 9926251506 9926251508 QZ-1-13-D-2-06 QZ-1-13-D-2-08 9926251510 9926251515 9926251520 QZ-1-13-D-2-10 QZ-1-13-D-2-15 QZ-1-13-D-2-20 9926251525 9926251535 9926251540 QZ-1-13-D-2-25 QZ-1-13-D-2-35 QZ-1-13-D-2-40 9926251550 9926251560 QZ-1-13-D-2-50 QZ-1-13-D-2-60 Part No. Description 9926252501 QZ-2-13-D-2-01 9926252502 9926252504 QZ-2-13-D-2-02 QZ-2-13-D-2-04 9926252505 9926252506 QZ-2-13-D-2-05 QZ-2-13-D-2-06 9926252510 9926252515 QZ-2-13-D-2-10 QZ-2-13-D-2-15 9926252520 9926252525 9926252530 QZ-2-13-D-2-20 QZ-2-13-D-2-25 QZ-2-13-D-2-30 9926252535 9926252540 9926252550 QZ-2-13-D-2-35 QZ-2-13-D-2-40 QZ-2-13-D-2-50 9926252560 QZ-2-13-D-2-60 Part No. Description 9926253510 QZ-3-13-D-2-10 9926253515 9926253520 QZ-3-13-D-2-15 QZ-3-13-D-2-20 9926253525 9926253530 QZ-3-13-D-2-25 QZ-3-13-D-2-30 9926253540 9926253550 QZ-3-13-D-2-40 QZ-3-13-D-2-50 9926253560 QZ-3-13-D-2-60 65 (2.56) 13 (0.51) 60 (2.36) 26 (1.02) 39 (1.54) 92.8 (3.65) 25.9 (0.94) 45 (1.77) 13 (0.51) 63.8 (2.51) 73 (2.87) Operating Characteristics Curve 2 Minutes 100 Ambient Temperature 30°C 10 1 10 1 0.1 0.01 (%) Rated Current 4000 5000 2000 2500 3000 1500 1000 0.001 400 500 The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit).The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Additional trip curves and amp ratings are available upon request. 1000 300 *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. 9926 Series–Supplemental Trip Curve Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 100 105 130 150 200 Technical Data Voltage 277/480 VAC @ 50/60 Hz Current minimum 0.5 A maximum 60 A Interrupting capacity 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V Dielectric strength 1500 V, 50/60 Hz Insulation resistance 100 MM Operating life 10000 mechanical operations Operating temperature -40…+65°C Wire size* 1-15A: 14 AWG min., 10 AWG max. 20-25A: 10 AWG min. Torque 20 in.-lb Approval UL 1077 Recognized, VDE (EN 60947-2), CSA C22.2 No. 235, CE Approved Tripping Time 5.0 (0.2) 13 (0.51) Seconds Part No. 67101904 67101972 67101971 67101973 67101974 67101960 67101961 67101913 44 (1.73) 6 Type: Triple Pole Current Rating (amps) 10 15 20 25 30 40 50 60 9926 Series Supplemental – dimensions in mm (in.) 22.5 (0.86) Type Bus bar (1 pole, insulated 1m) Bus bar (2 pole, insulated 1m) Bus bar (3 pole, insulated 1m) Bus bar end cap, 1 pole Bus bar end cap, 2 pole or 3 pole Power lug, straight Power lug, 90° Lock-out handle Type: Double Pole Current Rating (amps) 1 2 4 5 6 10 15 20 25 30 35 40 50 60 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s w i t h C o n t a c t s Circuit Breakers Auxiliary switch, Trip alarm, Combination of both 9926 Series Single Pole w/ Auxiliary Contact 9926 Series Single Pole Trip (Alarm Contact) 9926 Series Single Pole Combination (Auxiliary & Alarm Contact) • AC Voltages 240/480V • Trip curve 2 for general purpose applications • UL 1077 recognized • VDE, CSA, and CE Approved • Just 13 mm wide • Mounts to 35 mm DIN-rail • Factory fitted auxiliary or trip alarm • Single, double and triple pole versions Type: Single Pole Aux Technical Data Voltage 277/480 VAC @ 50/60 Hz Current minimum 0.5 A maximum 60 A Interrupting capacity 5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V Dielectric strength Insulation resistance Operating life 1500 V, 50/60 Hz 100 MM 10000 mechanical operations Operating temperature Wire size* 1-15A: 20-25A: Torque Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926261501 9926261502 Description QZ-A-1-13-D-2-01 QZ-A-1-13-D-2-02 9926261505 QZ-A-1-13-D-2-05 9926261510 QZ-A-1-13-D-2-10 9926261515 9926261520 QZ-A-1-13-D-2-15 QZ-A-1-13-D-2-20 9926261525 QZ-A-1-13-D-2-25 Type: Single Pole Trip Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926271501 9926271502 Description QZ-T-1-13-D-2-01 QZ-T-1-13-D-2-02 9926271505 QZ-T-1-13-D-2-05 9926271510 QZ-T-1-13-D-2-10 9926271515 9926271520 QZ-T-1-13-D-2-15 QZ-T-1-13-D-2-20 9926271525 QZ-T-1-13-D-2-25 Type: Single Pole Combo Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926281501 9926281502 Description QZ-AT-1-13-D-2-01 QZ-AT-1-13-D-2-02 9926281505 QZ-AT-1-13-D-2-05 9926281510 QZ-AT-1-13-D-2-10 9926281515 9926281520 QZ-AT-1-13-D-2-15 QZ-AT-1-13-D-2-20 9926281525 QZ-AT-1-13-D-2-25 -40…+65°C 14 AWG min., 10 AWG max. 10 AWG min. 20 in.-lb Approval UL 1077 Recognized, VDE (EN 60947-2), CSA C22.2 No. 235, CE Approved 9926 Series Double Pole w/ Auxiliary Contact 9926 Series Double Pole Combination (Auxiliary & Alarm Contact) 9926 Series Double Pole Trip (Alarm Contact) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags.The part number for adhesive SchS2 is 1720600000. 9926 Series–Supplemental Trip Curve Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC 1000 Operating Characteristics Curve 2 Type: Double Pole Aux Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926262501 9926262502 9926262505 Description QZ-A-2-13-D-2-01 QZ-A-2-13-D-2-02 QZ-A-2-13-D-2-05 9926262510 9926262515 9926262520 QZ-A-2-13-D-2-10 QZ-A-2-13-D-2-15 QZ-A-2-13-D-2-20 9926262525 QZ-A-2-13-D-2-25 Type: Double Pole Trip Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926272501 9926272502 9926272505 Description QZ-T-2-13-D-2-01 QZ-T-2-13-D-2-02 QZ-T-2-13-D-2-05 9926272510 9926272515 9926272520 QZ-T-2-13-D-2-10 QZ-T-2-13-D-2-15 QZ-T-2-13-D-2-20 9926272525 QZ-T-2-13-D-2-25 Type: Double Pole Combo Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926282501 9926282502 9926282505 Description QZ-AT-2-13-D-2-01 QZ-AT-2-13-D-2-02 QZ-AT-2-13-D-2-05 9926282510 9926282515 9926282520 QZ-AT-2-13-D-2-10 QZ-AT-2-13-D-2-15 QZ-AT-2-13-D-2-20 9926282525 QZ-AT-2-13-D-2-25 Tripping Time Minutes 100 Ambient Temperature 30°C 10 9926 Series Triple Pole w/ Auxiliary Contact 1 10 9926 Series Triple Pole Trip ( Alarm Contact) 9926 Series Triple Pole Combination (Auxiliary & Alarm Contact) Seconds 1 0.1 0.01 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 130 150 200 0.001 Type: Triple Pole Aux (%) Rated Current Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926263501 9926263502 9926263505 Description QZ-A-3-13-D-2-01 QZ-A-3-13-D-2-02 QZ-A-3-13-D-2-05 9926263510 9926263515 9926263520 QZ-A-3-13-D-2-10 QZ-A-3-13-D-2-15 QZ-A-3-13-D-2-20 9926263525 QZ-A-3-13-D-2-25 Type: Triple Pole Trip Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926273501 9926273502 9926273505 Description QZ-T-3-13-D-2-01 QZ-T-3-13-D-2-02 QZ-T-3-13-D-2-05 9926273510 9926273515 9926273520 QZ-T-3-13-D-2-10 QZ-T-3-13-D-2-15 QZ-T-3-13-D-2-20 9926273525 QZ-T-3-13-D-2-25 Type: Triple Pole Combo Current Ratings (amps) 1 2 5 10 15 20 25 Part No. 9926283501 9926283502 9926283505 Description QZ-AT-3-13-D-2-01 QZ-AT-3-13-D-2-02 QZ-AT-3-13-D-2-05 9926283510 9926283515 9926283520 QZ-AT-3-13-D-2-10 QZ-AT-3-13-D-2-15 QZ-AT-3-13-D-2-20 9926283525 QZ-AT-3-13-D-2-25 7 9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s – G F C I Ground Fault Current Interrupt Ordering Data 230 (CE) / 240 (UL) 5 kA – 0.26 1000 2 -40 to +65ºC - CB CB CB CB W/GFI W/GFI W/GFI W/GFI QF17A2550 - CB W/GFI Operating Characteristics Curve 2 100 44 (1.73) Ambient Temperature 30°C 10 68.8 (2.71) 1 10 26 (1.02) 1 Seconds Approval UL 1077 and UL 1053, CE QF17A2515 QF17A2520 QF17A2525 QF17A2530 Trip Curves—Hydraulic Magnetic Type Typical time/current characteristics at 30ºC Minutes Trip Curve (standard) Operating Temperature 73 (2.87) 65 (2.56) QF17A2510 - CB W/GFI 0.1 7.8 (0.307) 30 (CE) / 22 (UL) 1+N Earth Leakage/GFCS Rated Voltage (V) Rated Interrupting/ Withstand Capacity (kA) Weight (kg) Description QF17A2505 - CB W/GFI 9926 Series–AC version Trip Curve 5 to 50A Tripping Time Technical Data Standard Ampere Ratings (A) Sensitivity (mA) Number of Poles Equipment Type 9926 Series GFCI – dimensions in mm (in.) Type: Single Pole GFCI Current Ratings (amps) Part No. 5 9926291105 10 9926291110 15 9926291115 20 9926291120 25 9926291125 30 9926291130 50 9926291150 4000 5000 2000 2500 3000 1500 1000 400 500 300 100 105 130 150 200 0.001 16.4 (0.646) 8.0 (0.315) 71.4 (2.81) 0.01 26 (1.02) • (2.24) • • 57 • CE approved UL1077 and UL1053 recognized Small frame size (26mm wide) Single pole plus switched neutral earth leakage protection Trip point is unaffected by ambient temperature Current ratings up to 50A Trip indication (mid trip handle position) Trip curve 2 for general purpose applications 93 (3.66) 82.4 (3.24) • • • • 9926 Series GFCI (%) Rated Current 35.7 (1.406) 8 9926 Series Mounting Options and Accessories Mounting Options 93% 95 ON OFF 95 OF F ON OF F ON 5 N VERT 45 W ON OFF 100% ON VERT D 4 O R 5 N HO IZ DO 4 W 10 ON OF F ON OF F % ON OF F 5% 100% HORIZ 4 5 OFF UP UP It is important to note that in environments that are exposed to a high degree of vibration, the cables that connect to the circuit breaker must be securely held in place, as the breaker is not designed to carry the weight of the cables. A maximum of 35N can be applied to the terminal area, in a direction perpendicular to the mounting axis. % % If the product is not vertically mounted in the normal DIN-rail mounting orientation, a rating factor must be applied. Figure 1 shows a diagram of the rating factor to apply. The published curves for these circuit breaker products are produced with the circuit breaker in the vertical mounting position. The rating factor only applies to the must hold and must trip points of the curve as the other parts (instantaneous trip point) stay largely unaffected. 10 5 107% Accessories Technical Data Current Rating Part Number Table - Example 80A max. Voltage Short Circuit Strength 500V max. 25kA Type Bus bar (1 pole, insulated 1m) Bus bar (2 pole, insulated 1m) Part No. 67101904 67101972 Bus bar (3 pole, insulated 1m) 67101971 To order 9926 Series Single Pole Circuit Breaker Part No. 9926251100 • Current Rating of 1.0 amp • Internal Resistance per Pole of 1.1 ohms • Trip Curve – M1, Medium (Standard) 9 9 2 6 2 5 1 0 0 0 Amperage Type Part No. Bus bar end cap, 1 pole 67101973 Bus bar end cap, 2 pole or 3 pole 67101974 "00" - 0.5A "01" - 1A "02" - 2A / "60" - 60A Trip Curves "0" - Branch AC KM (Standard) "1" - Branch AC OP (Instantaneous) "2" - Branch AC 1 (Fast) "4" - Branch 80VDC 1 (Fast) "5" - Supplemental 2 (Standard) "6" - Branch 125VDC OP (Instantaneous) "7" - Branch 80VDC OP (Instantaneous) "8" - Branch 125VDC U2 (Standard) "9" - Branch 80VDC U2 (Standard) Technical Data Current Rating Wire Size Dimensions Poles 85A max. 10 AWG min., 4 AWG max. A: 6 mm B: 32 mm 1 Pole 2 Pole 3 Pole Type Type Power lug, straight Part No. 67101960 Power lug, 90° 67101961 Type Lock-out handle "5" - Base Breaker "6" - With Auxiliary Contact "7" - With Trip Alarm Contact "8" - Combo Aux/Trip Contact "9" - GFCI Part No. 67101913 9
7940099737 价格&库存

很抱歉,暂时无法提供与“7940099737”相匹配的价格&库存,您可以联系我们找货

免费人工找货