Relay Coupler
58
Relay Coupler
Contact material
Properties
Application
Fine silver
AG 99 %
- inexpensive
- average tendency to weld and average
resistance to burn-off
- subject to corrosion in sulphurous atmosphere
- high mechanical stability
- low tendency to weld
- low contact resistance
- high resistance to burn-off
- mechanical stability > AgNi
- tendency to weld < AgNi
- resistance to burn-off > AgNi
- contact resistance > AgNi
- very low tendency to weld
- resistance to burn-off > AgCu3/Ni
universal use
1 V…250 V
up to medium-size loads 1 mA…5 A
Silver nickel
AgNi 0.15
Hard silver
AgCu3
Silver cadmium
oxide
AgCdO
Silver-tinoxide
AgSnO2
Tungsten
W
Hard gold
AuNi
universal use
at medium-size loads
U/I
≥ 12 V
5 mA…10 A
for use with medium-size ≥ 12 V
loads
10 mA…10 A
suitable for switching
inductive loads
≥ 12 V
≥ 100 mA
- high thermal decomposition temperature
- more arc-resistant with low material transfer
suitable for swiching
inductive loads
≥ 12 V
≥ 100 mA
-
circuits with extremely
high on/off loads
dry circuits in
damp atmospheres
≥ 60 V
≥1A
µV…60 V
µA…0.2 V
very high resistance to burn-off
high switching rate with short closed times
< lowest contact resistance
best resistance to corrosion
= preferred materials
Types of contact
Contact material
The standard range comprises numerous
types and combinations of contacts.
1 NC
(EGR EG2, EGR EG7, RS 30)
1 NO
(EGR EG2, EGR EG7, DKR,
RS 30)
1 NC and 1 NO
(EGR EG2, WRS)
2 NO
(WRS)
3 NO
(WRS)
1 Changeover
(EGR EG2, EGR/RST EG7,
WRS DKR PRS/PRZ MCZ R,
RS 30, RS 31)
2 Changeover
(EGR EG2, WRS, RS 32,
PRS/PRZ)
4/8/16 Changeover
(RSM)
The all-round capability of Weidmüller relay
modules is achieved by the choice of the
contact material.
The contact is responsible for both the
reliable transmission of the control signals
and for switching power contactors.
Weidmüller uses gold-plated or goldflashed AgNi contacts for most applications. Gold-plated contacts permit
the switching of the low-power applications up to 40 µW with a gold-plating
thicker than 2 µm. For switching higher
ratings we use AgSnO2 or AgCdO contacts (RS 31).
59
Digital signal
processing
The universal foot of the Weidmüller relay
modules allow them to be assembled on
TS 32, TS 35 x 7.5 and TS 35 x 15
mounting rails in accordance with
European standards EN 50 035 and
EN 50 022.
An LED status indicator in the coil of the
relay coupler indicates the relay switching
status.
Relay Coupler
Protective circuits of the contacts
Switching sparks may occur when switching inductive or capacitive loads that affect
the operational life of the relay.
The following protective circuits offer the
possibility of reducing contact wear:
Diode:
+
–
US
Last
UD
Load
Switching of small and large power
ratings
For automation technology, Weidmüller
offers the EGR EGR 7 relay coupler to
switch ratings up to 40 µW under resistive
loads. This allows signals to be reliably
relayed to control devices.
The switching of higher power ratings in
power supply technology is achieved by
the RS 31 relay coupler, which guarantees
switching capacity up to 3.5 kVA under
resistive loads.
Switching times of the relay modules
1
Advantage:
2
t
can be used for all ratings, low
overvoltage, minimum space requirements, economic
pick-up delay
drop-out delay
typ. < 10 ms
typ. < 12 ms
Disadvantage: very long drop-out delay
Switching behaviour/load limit curve
(dependimg on type)
Diode and Z-diode:
Single contact
US
Last
UZD
Load
1
Advantage:
2
t
The contact resistance is largely responsible for heat development within the relay.
This link is demonstrated by a derating
curve as a function of the permissible current subject to the ambient temperature.
We determine the current (curve a) for the
following operating conditions:
- continuous operation
- rated input voltage + 10 %
- several relay modules operating under
load, mounted horizontally in a row
without spacing on mounting rail
A higher load is applicable when modules
are mounted with a gap of 20 mm as
shown in curve "b". In addition, the function of curve "b" shows the max. values
for a switching or short-time operation
when assembled horizontally on the
mounting rail.
Number of operations
+
–
Derating curves
low overvoltage (determined by Zdiode), low drop-out delay
Disadvantage: not usable for high power ratings
Switching capacity (kVA)
RC combination:
+
(~)
US
R
Last
URC
Load
C
1
Advantage:
Notes for usage
Direct current (A)
–
(~)
Contact life
with resistive load
2
t
low overvoltage, low drop-out delay
Disadvantage: higher current loading on contacts at
switch-on, complex and expensive for
increased power rating
Direct Voltage (V)
DC-limit
with resistive load
Varistor:
+
(~)
Last
RC combination
US
VDR
Load
UVDR
1
Advantage:
2
t
Reduction factor F
–
(~)
low drop-out delay, economic
Disadvantage: not for all operating voltages and
power ratings
Power factor
US
1
2
Voltage curve
Close
Open
Reduction factor
with inductive load cos j < 1
Switching no. eff.
= switching no (at cos j = 1) x red. Factor F
Relay couplers with plugged relays
Relay couplers with plugged relays are
only conditionally suitable for use in applications subject to heavy vibrations. Relay
couplers with soldered relays are to be
preferred.
60
The characteristic data of the actuation
are to be meticulously observed when
using UC variants in DC circuitry. UC variants have a higher current input at the
moment of switching due to their series
circuitry. The internal current limiter of
commercially available initiators can result
in the operated relay coupler not being
switched through.
Long supply cables are particularly open
to electrical and electro-mechanical influences. These can lead to disturbances of
the function or even failure of the relay
module. A remedy for this problem is an
RC combination in series that filters out
unwanted disturbances. RC combinations
are available for all customary relay couplers: pluggable (PLUGSERIES) or as terminal block (WDU 12C and DKU 12C).
Definition of Technical Data
All equipment required to guarantee "protective separation" must be constructed in
such a way that, for example, a mechanical defect cannot reduce the level of insulation. In the case of a relay, this means
that if a mechanical defect occurs (bent
solder pin, break in winding conductor or
broken spring), "protective separation"
must be guaranteed.
Relays are specified and tested according
to IEC 255 and VDE 0435. Neither standard contains any reference to
EN 50 178 (Equipping power installations
with electronic equipment) nor is "protective separation" defined. To compound
matters the test voltages quoted for the
relays are based on different measurement
conditions. The test voltages cannot be
applied to EN 50 178 or DIN VDE 0106
Part 101. As more and more users employ
only equipment that guarantees "protective separation", a lot of manufacturers of
relays refer to DIN VDE 0106 and test their
products accordingly. Consequently, the
quoted values correspond to the requirements for "protective separation".
Standards
The following standards are fulfilled:
EN 50 178
Equipping power installations with electronic equipment
DIN VDE 0106 Part 101
Protection against flow of dangerous currents through the human body; basic
requirements for protective separation
within electrical equipment.
DIN VDE 0109
Insulation co-ordination within low-voltage
system including clearance and creepage
distances for assembled PCBs.
DIN VDE 0435
Electrical relays, all-or-nothing relays
Input circuit
Input voltage [V]
Input current [mA]
Rated power consumption [W/VA]
Pull-in voltage [V]
Pick-up current [mA]
Pull-in power [W/VA]
Drop-out voltage [V]
Self reset current [mA]
Reference voltage at which the relay coupler operates.
Typical reference voltages:
=> 5 V DC, 12, 24, 48, 60, 115, 230 V AC/DC
Quotient resulting from input voltage and input resistance.
Input resistance
=> coil resistance + resistance of drive (R, LED, rect. …)
Input voltage x input current AC/DC
with tolerance of +/- 10% or +5/-15%
Typical range for relay coupler:
250 mW > Pv > 1 W 0.4 VA > Pv > 1.2 VA
Smallest input voltage that relay coupler requires
in order to respond
(Tamb = 293 K)
Smallest input current required to switch relay
from inoperative to operating position
(Tamb = 293 K)
Product of pull-in voltage and pick-up current
Voltage level at which relay has definitely released
Input current level at which relay has definitely released
Output circuit
Output voltage [V]
Switching current [A]
Continuous current [A]
Switching power [W/VA]
Min. switching power [mW]
Service life
Pick-up lag [ms]
Drop-out lag [ms]
Contact bounce time [ms]
Switching frequency [Hz]
Withstand voltage [kV]
Reliable separation
Electric arc
Contact wear
Spark absorption
Reduction factor
Max. voltage that can be applied to relay contact
Current that can flow for max. of 4 sec.
after relay contact has closed
Current that flows continuously after contact has closed
Product of output voltage and switching current
with resistive, inductive and capacitive load
Smallest amount of power that can be
switched via contact
Number of switching operations before contact fails
- mechanical => with no electric load
- electrical => with resistive or inductive AC/DC load
Length of time from application of energizing voltage
until contact closes/opens
Length of time from breaking the energizing circuit
until contact closes/opens
Length of time between first and last closing/opening
of contact when relay picks up or drops out
Switching operations per sec.
with a duty factor of 1 : 2 (ton = toff)
Max. test voltage between input and output circuits
which does not cause any discharge
Feature of relay coupler that conform
to VDE 0160 and VDE 0106 Part 101
Current flow between contact surfaces
as they open, caused by ionization
Switching inductive loads leads to considerable
changes in the composition of the materials used.
The results are:
=> formation of pits or peaks on the surface of contacts
=> failure due to interlocking of contacts
Limitation of transient overvoltages by connecting
supplementary circuit across inductive loads
=> RC combinations
=> Z-diodes/suppressor diodes
=> varistors
Factor by which service life is reduced
when switching inductive loads
Digital signal
processing
Protective separation
61
Types of Housings for Relay Coupler
Component housing EG
Component housing WAVEBOX
Weidmüller coupling modules are enclosed
in housings appropriate for industrial applications. The housings are suitable for fitting onto mounting rails TS 32, TS 35 x
7.5 or TS 35 x 15 in accordance with
European standards EN 50 035 and EN
50 022.
It is important to provide modern electronics components with housings suitable for
the function. Setting and operating functions must be guaranteed; technical
requirements with respect to heat dissipation and EMC properties are to be supported.
An ideal design saves space and wiring
costs in the switchgear cabinet. In addition, ergonomics and design are becoming
increasingly important for high-quality relay
coupler interfaces.
The WAVEBOX fulfils these criteria and is
further distinguished by the following:
Optimal width for any application
(12.5 mm, 17.5 mm, 22.5 mm)
Large component assembly surface;
SMDs mountable on solder side
No tools required for assembly
Pluggable PCBs
Pluggable cross-connection
via ZQV 2.5 N
Hinged, transparent cover
Screw/plug and socket connector
BLZ 5.08
Optional tension clamp/plug and socket
connector BLFZ 5.08
Marking option with WS tags
Mount onto TS 35
Connection systems
BLZ screw/plug-in connectors and BLZF
tension clamp/plug-in systems for flexible
conductors up to 2.5 mm2, to guarantee
maximum wiring flexibility.
Removing printed circuit boards
Accomplished by depressing the locking
clips at the side of the headpiece, and
withdrawing the terminal level and PCB
from the housing. This is not permitted
when the supply is connected.
Cross-connection
The ZQV 2.5 N/2 cross-connector can
connect housings of the same family at
the base of the housing. The cross-connection can be loaded with a current of up
to 8 A. This allows the supply voltage to
be cross-connected from one electronics
module to another.
The voltage at the cross-connection must
not exceed 50 V.
Ventilation vents
Ventilation vents, arranged at an angle,
temper and ventilate the lower side of the
housings.
Weidmüller component housings EG 1
and EG 2 are 18 mm wide.
The fully enclosed EG housings are
equipped with clamping yoke screw connections or push-on connections to connect conductors. Conductors with the following cross-sections can be connected:
solid core:
0.5...4 mm2 or
flexible:
0.5...2.5 mm2.
The component housing EG 7 has a special status. It has been specifically
designed to accommodate 10-mm slim
relays and optocouplers.
EG 7 relay couplers can be optionally
mounted onto TS 32 or TS 35 rails.
The RST EG 7 locking socket is also available for use with the pluggable relays couplers.
The enclosed EG 7 housing are equipped
with clamping yoke screw connections.
The following conductor cross-sections
can be connected:
NO/NC: 0.5...1.5 mm2
Changeover (RST): 0.5...2.5 mm2.
62
Modular system
PLUGSERIES/PLUGRELAY
is a new generation of pluggable relay
couplers. The core of this system is an
innovative relay socket PXS or PXZ.
Weidmüller has combined the functionality
and experience from its relay and terminal
block business in this product.
The PLUGRELAY is the ideal connection
technology between the relay and the
application.
Modular system principle
The PLUGSERIES is particularly service
friendly.
Commercially available relays are plugged;
retainer and release clips ensure stability,
LED indicators with free-wheeling diodes
can be easily plugged.
Relays can be easily plugged
- suitable for small electric circuits
standard design and BGD
Independent connection technology:
screw or tension clamp rated
cross-section 0.5...2.5 mm2
Robust design of retainer / release clip
One or two changeover contacts Max.
current switched 16 A
Low wiring costs thanks to ZQV 25N
cross-connectors (pluggable)
Service-friendly modular system
- relay socket, LED indicators,
retainer clips and relays
- mount onto TS 35
- marking options with WS markers
on retainer clips
Pluggable LED indicator with
free-wheeling diode
Types of Housings for Relay Coupler
Weidmüller RS locking socket
Minicoupler DK
MICROSERIES
Locking sockets with relays RS 30, 31,
32 are either 11.2 mm or 25 mm wide
depending on version. The open profile
makes the use of pluggable relays
possible.
Modules mounted onto the locking sockets are provided with clamping yoke screw
connections or push-on connectors for
wiring conductors.
Conductors with the following cross-sections can be connected:
solid core: 0.5...4 mm2
flexible:
0.5...2.5 mm2.
All DKR mini coupler components fulfil
demands for slimmest possible design.
The sensational width of only 6 mm is
achieved by using state-of-the-art surface
mountable components SMDs. 4 and 5
screw-connections are offered for 0.5...4
mm2 conductor cross-sections. The mini
couplers offer a wide spectrum for coupling digital sensor/actuator signals
between automation devices and the field
process. DKR relay couplers can receive
and standardise signals with varying voltages from the field.
The relay coupler and optocoupler variants
from the MICROSERIES are used in
applications in industrial automation to
isolate and couple digital input and output
signals. Their compact design means that
they are particularly suitable for use on
sub-distribution boards as well as in
switchgear cabinets where they help the
user to make optimum use of valuable
switching space. With its compact design,
the MICROSERIES elegantly combines
the functionality of the classic coupling
level and the terminal level.
Locking sockets with multiple
interfaces
Miniconditioner MCZ
6.1-mm mounting width
Pluggable cross-connections of four
potentials in the inputs and outputs
Proven cross-connection
system ZQV 4 N
Wide input voltage
spectrum from 5 ... 230 V
Digital signal
processing
RSM multiple interfaces can be optionally
assembled with 4, 8 or 16 relays.
To save wiring costs on the input side,
variants are offered with joint positive and
negative potentials.
The PCB connectors are provided with
clamping yoke screw connections for conductors with the following cross-sections:
solid core: 0.5...4 mm2 or
flexible:
0.5...2.5 mm2.
Some versions of the RSM coupler have
a male connector block available for
connecting pre-assembled cables on
the input side in accordance with
IEC 603-1/DIN 41 651.
The 6-mm MCZ housing is one of the
slimmest of its kind. It has the following
distinguishing features:
- Z-spring reduces mounting costs
- integrated cross-connection options in
the input and outputs minimise wiring
costs
MCZR miniconditioner (relay coupler) are
available with 4 or 5 Z-spring connections.
The clampable conductor cross-section is
0.5...1.5 mm2.
LED-indicator reverse-connect
protection free-wheeling diode
Housing material: WEMID
Flammability class: V0 in accordance
with UL 94
Innovative retaining and release system
Marking surfaces for fitting standard WS
12/6 markers
CE-marking
Weidmüller relay couplers are marked with
the CE symbol and comply with the
requirements of EN 50 081 Part 1 and EN
50 082 Part 2. They can therefore be used
for both industrial as well as for applications in residential, commercial and light
industry.
Appropriate ESD measures should be
taken during installation. If supply cables
are particularly long, overvoltage protection should be provided to prevent interference from electrical disturbance in the
atmosphere.
63
Relay Coupler
Electromechanical switching
Output
24 V
2x
Housing
EG
0133660000
Page 72
0536260000
Page 72
3x
0133560000
2x
4x
8x
16 x
1173461001
1113161001
1113261001
1113361001
1100061001
1100161001
1113461001
1113561001
1113761001
1112361001
1113661001
8018221001
1112761001
1107761001
1107861001
1112661001
1113861001
1173561001
1113061001
0160260000
Page 72
Page 73
0542660000
0123060000
Page 72
Page 73
WAVESERIES
8275350000
8418240000
8418270000
WRS
8286280000
8418250000
8418280000 Page 79
8416210000 Page 76
8418220000
Page 77
8418330000
8418300000
8418310000
8418320000
Page 78
8418230000
Page 74
EG 7*
8216520000
8216530000
8216570000
8147120000
8147140000
8216560000
8092340000
8092350000
Page 80
Page 80
8216580000
Page 80
PLUGSERIES
PRS / PRZ
8530621001
8530701001
8536530000
8536560000
8536650000
Page 82
RS 30
1101661001
1100961001
1181511001
1101611001
1100911001
1181521001
1101621001
1100921001
1100260000
1101761001
1101061001
1100210000
1101711001
1101011001
1100220000
1101721001
1101021001
Page 91
RS 31
Page 91
8530631001
8530691001
8536680000
Page 82
1100360000
Page 91
1128361001
1128331001
1128311001
Page 92
RS 32
9406121001
9406221001
Page 94
RSM
Page 97
Page 97
1173661001
Page 97
DKR 32
8016620000
8008110000
Page 70
DKR 35
8016610000
8008170000
Page 70
8181980000
8181970000
Page 71
8215620000
Page 71
DKR 35/32
9454910000
Page 71
MCZ R
8365980000
8442960000
8390590000
Page 68
MICROSERIES
MRS / MRZ
8533640000
8533660000
8556050000
8556120000
Page 87
* Approval by Germanischer Lloyd
Reliable
separation
64
24 V dc
24 Vuc/ac
Relay Coupler
Electromechanical switching
Output
48 V
2x
Housing
EG
0662660000
Page 72
3x
0662460000
2x
4x
8x
16 x
0160360000
0123260000
Page 72
Page 73
WAVESERIES
8286280000
WRS
EG 7*
Page 74
8092370000
Page 81
RS 30
1101861001
1101811001
1101821001
1101961001
1101911001
1101921001
Page 91
8092380000
Page 81
8418250000
Page 76
8418280000
Page 77
8418310000
Page 78
8216590000
Page 81
1101161001 1100460000
1101111001 1100410000
1101121001 1100420000
1101261001 1100560000
1101211001 Page 91
1101221001
Page 91
RS 31
1150761001
Page 92
RS 32
9406321001
Page 94
9406421001
1122661001
Page 95
RSM
1114061001 1114161001
1113961001 1114261001
1112461001 Page 97
1173761001
1114361001
1114461001
Page 97
Page 97
MICROSERIES
MRS / MRZ
8556040000
8556110000
115 V
EG
Digital signal
processing
Page 87
0141360000
0160460000
Page 73
WAVESERIES
8418220000
WRS
EG 7*
Page 75
8092430000
Page 81
8092440000
Page 81
Page 82
Page 91
RS 31
Page 77
8216610000
8536510000
8536610000
8530640000
8530790000
1155161001
1155111001
1155121001
1102161001
1102111001
1102121001
Page 76
8418290000
Page 81
PLUGSERIES
PRS / PRZ
RS 30
8418260000
8536520000
8536630000
8530660000
8530720000
Page 82
1155211001
1155261001
1155221001
1101461001
1101411001
1101421001
Page 91
1150361001
1150461001
Page 92
RS 32
1122761001
9406621001
Page 95
RSM
1114561001
Page 97
MCZ R
1114661001
Page 97
1114761001
Page 97
8420880000
8467470000
Page 61
MICROSERIES
MRS / MRZ
8556030000
8556100000
Page 87
* Approval by Germanischer Lloyd
Reliable
separation
Vdc
Vuc/ac
65
Relay Coupler
Electromechanical switching
Output
230 V
2x
Housing
EG
0543860000
Page 72
0543660000
8418230000
Page 75
8092470000
8178200000 Page 81
Page 81
8418260000
Page 76
8418290000
Page 77
8418340000
Page 79
8418320000
Page 78
Page 81
8530731001
Page 82
1102261001
1101561001
1102211001
1101511001 Page 91
1102221001
16 x
8216620000
8530671001
Page 91
8x
8216630000
PLUGSERIES
PRS / PRZ
RS 30
4x
Page 73
WRS
8092460000
2x
0142460000
Page 72
WAVESERIES
EG 7*
3x
8530681001
8530741001
Page 82
1100860000
1101521001
Page 91
RS 31
1128461001
1128431001
1128411001
Page 93
RS 32
9406721001
1122761001
Page 95
RSM
1114861001
1114961001
1115061001
1123461001
1108061001
1108261001
Page 97
MCZ R
8237710000
Page 69
MICROSERIES
MRS / MRZ
8556020000
8556090000
Page 87
240 V
RS 30
1128561001
1128661001
1128511001
1128611001
1128521001
Page 91
1128621001
Page 91
* Approval by Germanischer Lloyd
Reliable
separation
66
230 Vuc/ac
Page 97
Page 97
Relay Coupler
Electromechanical switching
Output
12 V
2x
3x
Housing
EG
2x
4x
8x
16 x
4x
8x
16 x
0160160000
Page 73
WAVESERIES
8418240000
WRS
EG 7*
Page 76
8092310000
Page 80
8092320000
Page 80
8418270000
8418300000
Page 77
Page 78
8216550000
Page 80
PLUGSERIES
PRS / PRZ
8536471001
8536501001
8536571001
8536591001
Page 82
RS 30
1129421001
Page 91
1129521001
Page 91
Page 82
1129660000
Page 91
RS 32
9406021001
Page 94
DKR 35
8171100000
Page 70
MICROSERIES
MRS / MRZ
8556070000
8556140000
Page 86
Output
2x
Housing
WAVESERIES
Page 74
WAVESERIES
8418210000
WRS 60 V
Page 74
8092400000
Page 81
RS 30, 60 V
8092410000
Page 81
8216600000
Page 81
1102061001
1100660000
1102011001
1100610000
1102021001
Page 91
DKR 32, 5 V
2x
8275320000
WRS 2, 4…24 V
EG 7*, 60 V
3x
Digital signal
processing
4…60 V
9406521001
Page 94
1100620000
Page 91
8019600000
Page 70
DKR 35, 5 V
8019610000
Page 70
MCZ R, 60 V
8470380000
Page 68
MICROSERIES
MRS / MRZ, 5 V
8556080000
8556150000
Page 86
MICROSERIES
MRS / MRZ, 60 V
8556060000
8556130000
Page 87
* Approval by Germanischer Lloyd
Reliable
separation
Vdc
Vuc/ac
67
Relay Couplers in Component Housings
Miniconditioners MCZ R
MCZ R 24 Vdc
MCZ R 24 Vdc/Au
Limit diagram
MCZ R 24 Vac/dc
MCZ R 60 Vdc
Derating curve
rowed without clearances on the mounting rail
rowed with 20 mm spacing on the mounting rail
U/Vdc
IL/A
300
6
5
prohibited area
200
4
3
100
2
25
1
1
2
3
4
5
6
IL/Adc
20
25
30
35
40
45
50
°C
Schematic circuit diagram
This module can be used as a universal interface between the controller and actuator for
switching medium-sized loads.
Reduces installation and commissioning
times by use of the proven Z-spring connection technology
Pluggable cross-connections in input and
output minimise wiring costs
6-mm width
Ordering data
for TS 35
Type
MCZ R 24 Vdc
Technical data
Input
Input voltage
Input current at UN
Type
Cat. No.
MCZ R 24 Vdc/Au 8442960000
Type
Cat. No.
MCZ R 24 Vac/dc 8390590000
Type
MCZ R 60 Vdc
24 Vdc ±20 % (19.2...28.8 V)
6.3 mA ±10 % (5.7...6.9 mA)
24 Vdc ±20 % (19.2...28.8 V)
6.3 mA ±10 % (5.7...6.9 mA)
60 Vdc ±20% (48...72 V)
3 mA ±20 % (12.4...3.6 mA)
Max. input power
156 mW ±10%
156 mW ±10%
Making threshold
Cut-out threshold
Reaction time at UN (typ.)
Release at UN (typ.)
Capacity working resistance to reduction at dissipated energy
Functionality
12 V...19 V
4 V...5.5 V
4.5 ms
10 ms
no
operating indication
reverse polarity protect. diode
free wheel diode
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106 switching operations
0.1 Hz
12 V...19 V
4 V...5.5 V
4.5 ms
10 ms
no
operating indication
reverse polarity protect. diode
free wheel diode
2, 3, 4
1 changeo. cont. (5 µ Au)
max. 300 Vdc / 400 Vac
max. 6 A* / max. 1500 VA
1) 0.1 mA
max. 6 A*
see limit diagram
20 x 106 switching operations
0.1 Hz
24 Vac/dc ±10% (21.6...26.4 V)
ac: 10.8 mA±15% (9.2…12.4 mA)
dc: 6.1 mA ±15% (5.2...7.1 mA)
ac: 160 mVA ±10 %
dc: 151 mW ±10 %
ac: ca. 17 V / dc: ca. 19 V
ac: ca. 7 V / dc: ca. 4 V
5 ms
30 ms
no
operating indication
bridge rectifier
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106 switching operations
0.1 Hz
ca. 38 V
ca. 14 V
4.5 ms
10 ms
no
operating indication
reverse polarity protect. diode
free wheel diode
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106 switching operations
0.1 Hz
300 V
4 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA, GL
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
4 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA, GL
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
4 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA, GL
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
4 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
Cross-connection on pin
Output
Switching voltage
ac: continuous current/switching power (see derating diagram)
Min. switching current
Switch-on current
dc: Continuous current/switching power
Mechanical service life
Max. switching frequency at nominal load
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Insulation coord.- and voltage proof, input/output mounting rail
Ambient temperature
Storage temperature
Conductor
Conductor cross-section
Approvals
Overall width
Accessories
End plate
Further accessories, dimensions and connection data see
68
Cat. No.
8365980000
1)
depends on load conditions
* the hard-gold plating is resistant for parameters 36 Vdc,
50 mA with 106 cycles
Cat. No.
8470380000
180 mW ±45 %
Relay Couplers in Component Housings
MCZ R 110 Vdc
MCZ R 120 Vac
MCZ R 230 Vac
Limit diagram
Derating curve
rowed without clearances on the mounting rail
rowed with 20 mm spacing
U/Vdc
IL/A
300
6
5
prohibited area
200
4
3
2
25
1
1
2
3
4
5
6
IL/Adc
20
25
30
35
Type
Cat. No.
MCZ R 110 Vdc 8467470000
Type
Cat. No.
MCZ R 120 Vac 8420880000
Type
Cat. No.
MCZ R 230 Vac 8237710000
110 Vdc ±10%
2.85 mA ±25%
120 Vac -15 %/+10 %
7 mA ±15 %
230 Vac ±10%
9.5 mA ±15 % (8...11mA)
340 mW ±25%
2.1 VA ±15 %
ca. 68 V / 1.6 mA
ca. 19 V / 0.4 mA
4.5 ms
10 ms
no
operating indication
bridge rectifier
0.85 VA ±15 %
( 380 mW ± 15 %)
ca. 70 V / 4 mA
ca. 22 V / 1.3 mA
8 ms
30 ms
yes
operating indication
bridge rectifier
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106 switching operations
0.1 Hz
2.3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 mA / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106 switching operations
0.1 Hz
2.3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106 switching operations
0.1 Hz
300 V
4 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
4 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
4 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
40
45
50
°C
Digital signal
processing
100
ca. 115 V / 5 mA
ca. 60 V / 2.5 mA
8 ms
30 ms
no
operating indication
bridge rectifier
69
Relay Couplers in Component Housings Mini coupler DKR
These modules are used for
protective separation of input
signals and adjustment of signal levels
DKR 5 Vdc
DKR 12 Vdc
DKR 24 Vac/dc
DKR 24 Vdc
Type
Cat. No.
DKR 24 Vac/dc 8008110000
DKR 24 Vac/dc 8016610000
Type
DKR 24 Vdc
DKR 24 Vdc
Cost-effective solution for
adjustment of power and
potential
Low input power
Screw connection technology
6-mm width
Schematic circuit diagram
Ordering data
for TS 32
for TS 35
With combination foot TS 32/TS 35
Technical data
Input voltage
Input current
Input current, limited = SPS able
Input power
Pick-up lag
Turn off delay
Y
W
Type
DKR 5 Vdc
DKR 5 Vdc
Cat. No.
8019600000
8019610000
Type
DKR 12 Vdc
Cat. No.
8171100000
Cat. No.
8016620000
8008170000
Input: bottom
5 Vdc ±5 %
12.5 mA
Input: bottom
12 Vdc ±10 %
12 mA
Input: bottom
24 Vac/dc ±20 %
11.5 mAac/9 mAdc
Input: bottom
24 Vdc ±20 %
9.3 mA
65 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
144 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
300 mVA/220 mW
0.6…4.5 ms ac/0.9…1.3 ms dc
12.7…25 ms ac/14.4…16.4 ms dc
225 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
500 mA
10 W/10 VA
100 V
500 mA
500 mA
10 W/10 VA
175 V
500 mA
500 mA
10 W/10 VA
170 V
500 mA
500 mA
10 W/10 VA
100 V
500 mA
200 Hz
RH/RU
1 normally-open contact
109 switching operations
5 x 108 switching operations
25 Hz
RH/RU
1 normally-open contact
109 switching operations
5 x 108 switching operations
5 Hz
RH/RU
1 normally-open contact
109 switching operations
5 x 108 switching operations
20 Hz
RH/RU
1 normally-open contact
109 switching operations
5 x 108 switching operations
150 V
1.5 kV
III
2
≥3 mm
150 V
1.5 kV
III
2
≥3 mm
150 V
1.5 kV
III
2
≥3 mm
150 V
1.5 kV
III
2
≥3 mm
Storage temperature
Conductor
Conductor cross-section
Overall width
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Accessories
End plate
Further accessories, dimensions and connection data see
Type
AP DKT4
Page 305
Max. switch-on current
Max. switching capacity
Max. output voltage
Max. output current
Min. output current
Max. switching frequency
Contact material
Contacts
Service life
mechanical
at lL= 10 mA
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature
70
without clearance
with clearance
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Relay Couplers in Component Housings Mini coupler DKR
Type
DKR 24 Vdc
Cat. No.
DK5R-1U
Type
DKR 24 Vdc
Cat. No.
8215620000
DKR 24 Vdc
DK5R-1U
9454910000
Input: bottom
24 Vac/dc ±20 %
9 mAac/7 mAdc
max. 240 mA
Input: top
24 Vdc ±20 %
9.3 mA
8181980000
Input: bottom
24 Vdc ±20 %
11.5 mA
Type
Cat. No.
DKR 24 Vac/dc 8181970000
384 mW
5A
2 kVA/192 W
250 Vac/dc
8A
100 mA
25 Hz
AgCdO
1 changeover contact
≥107 switching operations
≥3 x 106 switching operations
5A
2 kVA/192 W
250 Vac/dc
8A
100 mA
ac: 5 Hz dc: 25 Hz
AgCdO
1 changeover contact
≥107 switching operations
≥3 x 106 switching operations
300 V
4 kV
III
2
≥8 mm
300 V
6 kV
IV
2
≥8 mm
300 V
6 kV
IV
2
≥8 mm
-40 °C...+60 °C
-40 °C...+60 °C
-40 °C...+60 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
18 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
18 mm
6 ms
15 ms ac/dc
500 mA
10 W/10 VA
175 Vac/dc
500 mA
4A
1.5 kVA/140 W
250 Vac/dc
6A
25 Hz
RH/RU
1 normally-open contact
109 switching operations
5 x 108 switching operations
20 Hz
Ag Ni
1 changeover contact
2x107 switching operations
150 V
1.5 kV
III
2
≥3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Cat. No.
0687560000
Cat. No.
Input: bottom
24 Vac/dc ±20 %
20 mAac/16 mAdc
max. 100 mA
480 mWac/400 mWdc
225 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
Type
AP DKT4
Page 305
Type
DKR 24 Vac/dc
Type
AP DK5
Page 305
Cat. No.
8268870000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Type
AP DKT4
Page 305
Digital signal
processing
DKR 24 Vac/dc
Cat. No.
0687560000
71
Relay Coupler in Component Housings EG 2
with 1 NO or 1 NC
EGR EG 2
24 V
EGR EG 2
24 V
EGR EG 2
48 V
Direct and alternating voltage
AC/DC voltage
EGR EG 2
230 V
AC voltage
Schematic circuit diagram
Type
NC
NO
Ordering data
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay** (at 20 °C)
Max. output voltage
Continuous current
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance x 20 mm
Cat. No.
01335600001)
01336600001)
Type
NC
NO
Cat. No.
0542660000
0536260000
Type
NC
NO
Cat. No.
0662460000
0662660000
Type
NC
NO
Cat. No.
0543660000
0543860000
24 V–, ±10 %
0.36 W
–
1.5 mA
24 V0, ±10 %
0.35 W
0.6 VA
1.5 mA–/4 mA~
48 V0, ±10 %
0.8 W
0.9 VA
1.5 mA–/3.5 mA~
230 V~, +5 % –15 %
–
3.2 VA
4 mA
240 V~/100 V–
3A
240 V~/100 V–
3A
240 V~/100 V–
1A
240 V~/100 V–
1A
5A
600 VA/120 W
40 µW
< 2 ms
5A
600 VA/120 W
40 µW
< 2 ms
5A
600 VA/120 W
40 µW
< 2 ms
5A
600 VA/120 W
40 µW
< 2 ms
< 5.3 ms
< 8.3 ms
50 Hz
AgNi, gold-plated
> 107 switching operations
> 6 x 105 switching operations
> 105 switching operations
Green LED
–40 °C…+60 °C
< 8 ms
< 22 ms
30 Hz
AgNi, gold-plated
> 107 switching operations
> 6 x 105 switching operations
> 105 switching operations
Green LED
–40 °C…+60 °C
< 9 ms
< 12 ms
37 Hz
AgNi, gold-plated
> 107 switching operations
> 6 x 105 switching operations
> 105 switching operations
Green LED
–40 °C…+60 °C
< 5 ms
< 7 ms
40 Hz
AgNi, gold-plated
> 107 switching operations
> 6 x 105 switching operations
> 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
–25 °C…+50 °C
CSA (013366)
–25 °C…+40 °C
–25 °C…+50 °C
–25 °C…+40 °C
–25 °C…+50 °C
–25 °C…+40 °C
–25 °C…+50 °C
III
3
Page 306, Fig. II
III
3
Page 306, Fig. II
III
2
Page 306, Fig. II
III
2
Page 306, Fig. II
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Status indicator
Storage temperature
Ambient temperature
–, mounted on rail without clearance
–, mounted on rail with clearance ≥ 20 mm
Approvals
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Accessories, dimensions and connection data see
** Larger values on request
72
1)
no output varistor
Relay Coupler in Component Housings EG 2
with 2.8-mm tab connection
EGR EG 2
EGR EG 2
DC voltage
2 changeover contacts
AC/DC voltage
2 changeover contacts
Schematic circuit diagram
LED is parallel
to coil in 12 V DC
and 24 V DC
versions
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay** (at 20 °C)
Max. output voltage
Continuous current
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance x 20 mm
Type
Cat. No.
EGR 2 RT (12 V–) 0160160000
EGR 2 RT (24 V–) 0160260000
Type
Cat. No.
EGR 2 RT (48 V–) 0160360000
EGR 2 RT (115 V–) 0160460000
Type
Cat. No.
EGR 2 RT (24 V0) 0123060000
EGR 2 RT (48 V0) 0123260000
EGR 2 RT (115 V0) 0141360000
12 V–
0.61 W
–
12 mA
48 V–
0.65 W
–
2.5 mA
24 V0
0.7 W
1 VA
3.5 mA–/8 mA~
115 V0
0.6 W
0.6 VA
1 mA–/1 mA~
24 V–
0.54 W
–
5.5 mA
115 V–
0.6 W
–
1 mA
48 V0
0.7 W
0.9 VA
2 mA–/3.5 mA~
Type
Cat. No.
EGR 2 RT (230 V0) 0142460000
230 V0
1.2 W
1.2 VA
1 mA
250 V
5A
250 V
5A
250 V
5A
250 V
5A
15 A/200 ms
1100 VA/144 W
5A
4 ms
15 A/200 ms
1100 VA/144 W
5A
4 ms
15 A/200 ms
1100 VA/144 W
5A
4 ms
014246
15 A/200 ms
1100 VA/144 W
5A
4 ms
16 ms
22 ms
20 ms
15 ms
20 Hz
20 Hz
Ag, gold-flashed
30 x 106
105 (1100 VA, cos : = 1)
18 ms
14 ms
16 ms
23 ms
27 Hz
24 Hz
Ag, gold-flashed
30 x 106
105 (1100 VA, cos := 1)
23 ms
18 ms
25 ms
19 ms
19 Hz
21 Hz
Ag, gold-flashed
30 x 106
105 (1100 VA, cos := 1)
17 ms
13 ms
17 ms
18 ms
24 Hz
22 Hz
Ag, gold-flashed
30 x 106
105 (1100 VA, cos := 1)
Red LED
–40 °C…+85 °C
Red LED
–40 °C…+85 °C
Red LED
–40 °C…+85 °C
Red LED
–40 °C…+85 °C
–25 °C…+40 °C
–25 °C…+40 °C
–25 °C…+40 °C
–25 °C…+40 °C
III
2
Page 306, Fig. III
III
2
Page 306, Fig. III
III
2
Page 306, Fig. III
III
2
Page 306, Fig. III
Digital signal
processing
Ordering data
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. braking capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Status indicator
Storage temperature
Ambient temperature
–, mounted on rail without clearance
–, mounted on rail with clearance ≥ 20 mm
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Accessories, dimensions and connection data see
** Larger values on request
73
WAVESERIES Relay Coupler in Component Housings
With 1 changeover contact
WRS 1 2.4-24 VDC WRS 1 24 VDC
WRS 1 24/48 VUC
WRS 1 24/60 VUC
Ordering data
Screw connection
Type
Cat. No.
WRS 1 2.4-24 Vdc 8275320000
Type
WRS 1 24 Vdc
Cat. No.
8275350000
Type
Cat. No.
WRS 1 24/48 Vuc 8286280000
Type
Cat. No.
WRS 1 24/60 Vuc 8418210000
Tension clamp connection
WRZ 1
WRZ 1
8430180000
WRZ 1
WRZ 1
Input
Input voltage
Input current
2.4…24 Vdc +10 %
4.6 mAdc ±15% at Ue 12 V
24 Vdc±10 %
9 mAdc±15%
24 Vuc±10 % /48 Vuc±10%
14 mAuc±15% at Ue 24 V
14 mAuc±15% at Ue 48V
Input power
6 mW ±15% at Ue 2.4 V
220 mW±15%
0.5 VA (W)±15% at Ue=48V
0.35 VA (W)±15% at Ue=24V
Turn off delay
max. 150 Vdc /250 Vac
max. 5 A /max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
typ. 7 ms (NO) /
4.5 ms (NC)
typ. 6.3 ms (NO) /
max. 150 Vdc /250 Vac
max. 5 A /max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
typ. 7 ms (NO) /
4.5 ms (NC)
typ. 6.3 ms (NO) /
max. 150 Vdc /250 Vac
max. 5A /max. 1250 VA*
max. 10 A
100 mA/5Vdc
Ag-alloy
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
typ. 7 ms (NO) /
4.5 ms (NC)
typ. 6.3 ms (NO) /
max. 150 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 mΩ/max. 100 mΩ
at 1 A / 6 Vdc
typ. 5.4 ms (NO) /
4.2 ms (NC)
typ. 4.4 ms (NO) /
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
5.5 ms (NC)
20 x 106 switching operations
150 x 103 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
5.5 ms (NC)
20 x 106 switching operations
150 x 103 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
5.5 ms (NC)
20 x 106 switching operations
1.5 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
5.4 ms (NC)
20 x 106 switching operations
150 x 103 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
4 kVeff 1 min
4 kVeff 1 min
4 kVeff 1 min
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
Relay couplers in the WAVEBOX
Independent connection technology
- pluggable connection unit
screw or tension clamp technology
Fast commissioning and after-salesservice service
- pluggable PCBs
Save wiring tasks
- cross-connections possible at input
and output
Schematic circuit diagram
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
* at ambient temperature 20°C
74
8430170000
8430190000
8430200000
24 Vuc±10% / 60 Vuc±10%
11 mAac±15% at Ue=60 V
10 mAdc±15% at Ue=60 V
10.2 mAac±15% at Ue=24 V
9 mAdc±15% at Ue=24 V
0.7 VA ±15% at Ue=60 V
0.34 VA±15% at Ue=24 V
0.6 W ±15% at Ue=60 V
0.22 W±15% at Ue=24 V
WAVESERIES Relay Coupler in Component Housings
WRS 1 24/115 VUC WRS 1 24 VUC
230 VAC
Mounted
horizontally
waagerecht
montiert
Control 26.4Vdc
Ansteuerung
26,4Vdc
8
clearance
>= 10 mm
Abstand>=10mm
7
Output current [A]
6
mounted
5
4
3
2
1
0
0
20
40
60
80
100
Ambient temperature [°C] [°C]
Umgebungstemperatur
WRS 1 2.4-24 VDC • 8275320000
Mounted horizontally
waagerecht
montiert
Ansteuerung
52,8Vdc
Control 52.8Vdc
8
Output current [A]
7
Abstand>=10mm
clearance >= 10
mm
mounted
6
5
4
3
2
1
0
0
20
40
60
80
100
Ambient temperature [°C]
Umgebungstemperatur
[°C]
WRS 1 24/48 VUC • 8286280000
Type
Cat. No.
WRS 1 24 Vuc/230 Vac
8418230000
WRZ 1
8430220000
Vuc±10% / 230 Vac±10%
mAac±15% at Ue=230 V
mAac±15% at Ue=24 V
mAdc±15% at Ue=24 V
max. 150 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 mΩ/max. 100 mΩ
at 1 A / 6 Vdc
typ. 5.4 ms (NO) /
4.2 ms (NC)
typ. 4.4 ms (NO) /
max. 150 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 mΩ/max. 100 mΩ
at 1 A / 6 Vdc
typ. 5.4 ms (NO) /
4.2 ms (NC)
typ. 4.4 ms (NO) /
5.4 ms (NC)
20 x 106 switching operations
150 x 103 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
5.4 ms (NC)
20 x 106 switching operations
150 x 103 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
4 kVeff 1 min
4 kVeff 1 min
7
mounted
6
Abstand>=10mm
clearance >= 10
mm
5
4
3
2
Digital signal
processing
24
15
14
13
8
Output current [A]
24 Vuc±10% / 115 Vuc±10%
11 mAac±15% at Ue=115 V
10.5mAdc±15% at Ue=115 V
10.2 mAac±15% at Ue=24 V
9 mAdc±15% at Ue=24 V
1.3 VA ±15% at Ue=115 V
0.34 VA±15% at Ue=24 V
1.2 W ±15% at Ue=115 V
0.22 W±15% at Ue=24 V
Mounted horizontally
waagerecht
montiert
Control 66Vdc
Ansteuerung
66Vdc
1
3.5 VA ±15% at Ue=230 V
0.34 VA±15% at Ue=24 V
0.32 W±15% at Ue=24 V
0
0
20
40
60
80
100
Ambient temperature [°C]
[°C]
Umgebungstemperatur
WRS 1 24/60 VUC • 8418210000
Mounted horizontally
waagerecht
montiert
Ansteuerung
ac / dc
Control26,4V
26.4V ac/dc
8
7
clearance >= 10
Abstand>=10mm
Output current [A]
mm
mounted
6
5
4
3
2
1
0
0
20
40
60
80
100
Ambient temperature [°C] [°C]
Umgebungstemperatur
WRS 1 24/115 VUC • 8418220000
Mounted horizontally
waagerecht
montiert
Ansteuerung
253Vac
Control 253Vac
8
clearance >= 10
Abstand>=10mm
7
Output current [A]
Type
Cat. No.
WRS 1 24/115 Vuc
8418220000
WRZ 1
8430210000
6
mm
mounted
5
4
3
2
1
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
0
0
20
40
60
80
100
Ambient temperature [°C][°C]
Umgebungstemperatur
WRS 1 24 VUC/230 VAC • 8418230000
75
WAVESERIES Relay Coupler in Component Housings
with 2 NO contacts
WRS 2 12/24 VDC
WRS 2 24/48 VUC
WRS 2 115 VUC/
230 VAC
Type
Cat. No.
WRS 2 12/24 Vdc
8418240000
WRZ 2
8430230000
Type
Cat. No.
WRS 2 24/48 Vuc
8418250000
WRZ 2
8430240000
Type
Cat. No.
WRS 2 115 Vuc/230 Vac
8418260000
WRZ 2
8430250000
12 Vdc±10 % / 24 Vdc±10 %
21 mAdc±15% at Ue=24 V
20 mAdc±15%bei Ue=12 V
24 Vuc±10 % / 48 Vuc±10 %
10 mAac±15% at Ue=48 V
11.5 mAac±15% at Ue=24 V
8.5 mAdc±15% at Ue=48 V
7.2 mAdc±15% at Ue=24 V
0.48 VA±15% at Ue=48 V
0.21 VA±15% at Ue=24 V
0.4 W±15% at Ue=48 V
0.17 W±15% at Ue=24 V
115 Vuc±10%/ 230 Vac±10 %
11 mAac±15% at Ue=230 V
8.5 mAuc±15% at Ue=115 V
8 mAdc±15% at Ue=115 V
max. 250 Vdc / 250 Vac
(UL –> 13300/12300)
max. 5 A / max. 1250 VA*
max. 8 A
100 mA / 5 Vdc
AgSnO2
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
typ. 5 ms
typ. 6.3 ms (NO) /
max. 250 Vdc / 250 Vac
(UL –> 13300/12300)
max. 5 A / max. 1250 VA*
max. 8 A
100 mA / 5 Vdc
AgSnO2
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
typ. 5 ms
---
max. 250 Vdc / 250 Vac
(UL –> 13300/12300)
max. 5 A / max. 1250 VA*
max. 8 A
100 mA / 5 Vdc
AgSnO2
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
-----
5.5 ms (NC)
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA (nur 115 Vuc)
300 V
4 kV (1.2/50 µ)
III
2
≥ 8 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 8 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 8 mm
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
4 kVeff 1 min
4 kVeff 1 min
4 kVeff 1 min
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
WRS
2 12/24 VDC
-> 8418240000
Mounted
horizontally
waagerecht montiert
Control
26.4 Vdc
26.4 Vdc
Ansteuerung
26,4Vdc
8
clearance ≥ 10 mm
Output current [A]
7
Abstand>=10mm
mounted
angereiht
6
5
4
3
2
1
0
0
20
40
60
80
100
Ambient
temperature [°C]
[°C]
Umgebungstemperatur
WRS 2 12/24 VDC • 8418240000
WRS 2 24/48 VUC -> 8418250000
Mounted
horizontally
waagerecht
montiert
Ansteuerung 52,8Vdc
Control
26.4 Vdc 52.8 Vdc
8
7
Abstand>=10mm
clearance ≥ 10 mm
Output current [A]
angereiht
mounted
6
5
4
3
2
Schematic circuit diagram
1
0
0
20
40
60
80
100
Umgebungstemperatur
Ambient
temperature[°C]
[°C]
WRS 2 24/48 VUC • 8418250000
Mounted horizontally
253Vac
Control 26.4 Vdc 253 Vdc
WRS 2 115 VUC/ 230 VAC -> 8418260000
waagerecht montiert; Ansteuerung
8
clearance ≥ 10 mm
Output current [A]
7
Abstand>=10mm
mounted
6
5
4
3
2
1
0
0
10
20
30
40
50
60
70
80
Umgebungstemperatur [°C]
Ambient
temperature [°C]
WRS 2 115 VUC/ 230 VAC • 8418260000
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
Turn off delay
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
* at ambient temperature 20°C
76
0.5 W±15% at Ue=24 V
0.24 W±15% at Ue=12 V
2.5 VA±15% at Ue=230 V
1 VA±15% at Ue=115 V
0.9 W±15% at Ue=115 V
WAVESERIES Relay Coupler in Component Housings
with 1NC / 1 NO
WRS 2 12/24 VDC
WRS 2 24/48 VUC
WRS 2 115 VUC/
230 VAC
Type
Cat. No.
WRS 2 12/24 Vdc
8418270000
WRZ 2
8430260000
Type
Cat. No.
WRS 2 24/48 Vuc
8418280000
WRZ 2
8430270000
Type
Cat. No.
WRS 2 115 Vuc/230 Vac
8418290000
WRZ 2
8430280000
12 Vdc±10% / 24 Vdc±10%
19.7 mAdc±15% at Ue=12 V
20.5 mAdc±15% at Ue=24 V
24 Vuc±10 % / 48 Vuc±10 %
10 mAac±15% at Ue=48 V
11.5 mAac±15% at Ue=24 V
8.5 mAdc±15% at Ue=48 V
7.2 mAdc±15%bei Ue=24 V
0.48 VA±15% at Ue=48 V
0.21 VA±15% at Ue=24 V
0.4 W±15% at Ue=48 V
0.17 W±15% at Ue=24 V
115 Vuc±10 %/230 Vac±10 %
11 mAac±15% at Ue=230 V
10 mAuc±15% at Ue=115 V
8 mAdc±15% at Ue=115 V
Pick-up delay at nominal voltage
Turn off delay
max. 250 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 8 A
100 mA/5 V
AgSnO2
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
typ. 5ms
---
max. 250 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 8 A
100 mA/5 V
AgSnO2
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
-----
max. 250 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 8 A
100 mA/5 V
AgSnO2
max. 30 mΩ/max. 100 mΩ
at 1 A/6 Vdc
-----
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA (nur 115 Vuc)
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
300 V
4 kV (1.2/50 µ)
III
2
≥ 8 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 8 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 8 mm
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
4 kVeff 1 min
4 kVeff 1 min
4 kVeff 1 min
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
Mounted horizontally
Control 26.4 Vdc 26.4 Vdc
8
7
clearance ≥ 10 mm
Output current [A]
Abstand>=10mm
6
angereiht
mounted
5
4
3
2
1
0
0
20
40
60
80
100
Ambient temperature [°C]
WRS 2 12/24 VDC • 8418270000
WRS 2 24/48 VUC -> 8418280000
Mounted
horizontally
waagerecht montiert
Ansteuerung
52,8Vac
Control
26.4 Vdc
52.8 Vdc
Output current [A]
9
8
clearance ≥ 10 mm
7
Abstand>=10mm
6
angereiht
mounted
5
4
3
2
Schematic circuit diagram
1
0
0
20
40
60
80
100
Umgebungstemperatur
Ambient
temperature[°C]
[°C]
WRS 2 24/48 VUC • 8418280000
WRS 2 115 VUC/230 VAC -> 8418290000
Mounted horizontally 253Vac
Control 26.4 Vdc 253 Vdc
waagerecht montiert; Ansteuerung
8
Output current [A]
7
clearance ≥ 10 mm
Abstand>=10mm
mounted
6
5
4
3
2
1
0
0
20
40
60
80
100
Umgebungstemperatur
Ambient
temperature
[°C]
Ambient
temperature[°C]
[°C]
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
0.5 W±15% at Ue=24 V
0.24 W±15% at Ue=12 V
Digital signal
processing
WRS 2 115 VUC/230 VAC • 8418290000
2.5 VA±15% at Ue=230 V
1 VA±15% at Ue=115 V
0.9 W±15% at Ue=115 V
* at ambient temperature 20°C
77
WAVESERIES Relay Coupler in Component Housings
with 2 changeover contacts
WRS 2 12/24 VDC
WRS 2 24/48 VUC
WRS 2 24 VUC/
230 VAC
Type
Cat. No.
WRS 2 12/24 Vdc
8418300000
WRZ 2
8430290000
Type
Cat. No.
WRS 2 24/48 Vuc
8418310000
WRZ 2
8430300000
Type
Cat. No.
WRS 2 24 VUC/230 Vac
8418320000
WRZ 2
8430310000
12 Vdc±10% /24 Vdc±10 %
21 mAdc±15% at Ue=12 V
22 mAdc±15% at Ue=24 V
24 Vuc±10% /48 Vuc±10 %
14 mAuc±15% at Ue=48 V
14 mAuc±15% at Ue=24 V
24 Vuc±10% /230 Vac±10%
15 mAac±15% at Ue=230 V
14 mAuc±15% at Ue=24 V
0.26 W±15% at Ue=12 V
0.53 W±15% at Ue=24 V
0.7 VA(W)±15% at Ue=48 V
0.35 VA(W)±15% at Ue=24 V
0.35 W±15% at Ue=24 V
3.45 VA ±15% at Ue=230 V
Turn off delay
max. 150 Vdc /250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 mΩ / max. 100 mΩ
at 1 A / 6 Vdc
typ. 6.5 ms (NO) /
4.5 ms (NC)
typ. 8 ms (NO) /
max. 150 Vdc /250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 mΩ / max. 100 mΩ
at 1 A / 6 Vdc
typ. 6.5 ms (NO) /
4.5 ms (NC)
typ. 8 ms (NO)/
max. 150 Vdc /250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA / 5 Vdc
Ag-alloy
max. 30 mΩ / max. 100 mΩ
at 1 A / 6 Vdc
typ. 6 ms (NO)/4.2 ms
(NC)/Eingang: 24 Vuc/230 Vac
typ. 4.4 ms (NO)/
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
11 ms (NC)
20 x 106 switching operations
1.5 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
11 ms (NC)
20 x 106 switching operations
1.5 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
5.4 ms (NC)
20 x 106 switching operations
150 x 103 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
4 kVeff 1 min
4 kVeff 1 min
4 kVeff 1 min
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
WRS 2 12/24 VDC 8418300000
Mounted
horizontally
waagerecht
montiert
Ansteuerung 26,4Vdc
Control
26.4 Vdc 26.4 Vdc
7
clearance ≥ 10 mm
Abstand>=10mm
Output current [A]
6
angereiht
mounted
5
4
3
2
1
0
0
20
40
60
80
100
Umgebungstemperatur
Ambient
temperature[°C]
[°C]
WRS 2 12/24 VDC • 8418300000
WRS
2 24/48 VUC
8418310000
Mounted
horizontally
waagerecht montiert
Control
26.4 Vdc
26.4 Vdc
Ansteuerung
26,4Vac
8
Output current [A]
7
clearance
≥ 10 mm
Abstand>=10mm
6
angereiht
mounted
5
4
3
2
Schematic circuit diagram
1
0
0
20
40
60
80
100
Umgebungstemperatur
Ambient
temperature[°C]
[°C]
WRS 2 24/48 VUC • 8418310000
WRS 2 24 VUC/ 230 VAC 8418320000
Mounted
horizontally
waagerecht
montiert
Ansteuerung
253Vac
Control
26.4 Vdc
253 Vdc
Output current [A]
8
7
6
Abstand>=10mm
mounted
5
4
3
2
1
0
0
10
20
30
40
50
60
70
80
Umgebungstemperatur [°C]
Ambient
temperature [°C]
WRS 2 24 VUC/ 230 VAC • 8418320000
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
* at ambient temperature 20°C
78
WAVESERIES Relay Coupler in Component Housings
with 3 NO contacts
WRS 2 24 VUC
WRS 2 230 VAC
WRS 2 24 VUC 8418330000
Mounted horizontally26,4Vdc
Control 26.4 Vdc 26.4 Vdc
waagerecht montiert; Ansteurung
7
Output current [A]
6
Abstand>=10mm
clearance ≥ 10 mm
5
angereiht
mounted
4
3
2
1
0
0
20
40
60
80
100
80
100
Umgebungstemperatur [°C]
Ambient
temperature [°C]
WRS 2 24 VUC • 8418330000
WRS 2 230 VAC -> 8418340000
Mounted horizontally253Vac
Control 26.4 Vdc 253 Vdc
waagerecht montiert; Ansteuerung
7
Output current [A]
6
angereiht
mounted
5
Abstand>=10mm
clearance
≥ 10 mm
4
3
2
Schematic circuit diagram
1
0
0
20
40
60
Ambient temperature °C]
[°C]
WRS 2 230 VAC • 8418340000
Input
Input voltage
Input current
Type
WRS 2 24 Vuc
WRZ 2
Cat. No.
8418330000
8430320000
Type
Cat. No.
WRS 2 230 Vac 8418340000
WRZ 2
8430330000
3fach 24 Vac ±10 %
10.5 mAac ±15 % at Unenn
(per channel)
3 x 230 Vac ±10 %
10.3 mAac ±15 % at Unenn
(per channel)
0.3 VA ±15 % (per channel)
0.25 W ±15 %
2.4 VA ±15 % (per channel)
Pick-up delay at nominal voltage
max. 250 Vdc /250 Vac
max. 4 A/max. 1500 VA*
max. 6 A
12 V/10 mA
AgSnO2
max. 100 mΩ
at 1 A/24 Vdc
typ. 5 ms
max. 250 Vdc / 250 Vac
max. 4 A/max. 1500 VA*
max. 6 A
12 V/10 mA
AgSnO2
max. 100 mΩ
at 1 A/24 Vdc
typ. 8 ms
Turn off delay
typ. 21 ms
typ.11 ms
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
20 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
20 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
300 V
4 kV (1.2/50 µ)
III
2
≥ 5.5 mm
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
4 kVeff 1 min
4 kVeff 1 min
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
4 kVeff 1 s
Page 298 + 308
4 kVeff 1 s
Page 298 + 308
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Digital signal
processing
Ordering data
Screw connection
Tension clamp connection
* at ambient temperature 20°C
79
Relay Couplers in Components Housings EG 7
Plugs on to locking socket RS EG 7
with combination foot TS 32, 35
Overall width: 10 mm
With combination foot for TS 15, TS 32
or TS 35
Versions with 12 V, 24 V and 48 V fulfil
protective separation in accordance
with VDE 0160, Part 101
All EGR EG 7 and RST EG 7 are
approved by Germanischer Lloyd.
Approval No. 35962 HH
EGR EG 7
RST EG 7
RS EG 7
RST EG 7
RS EG 7
EGR EG 7
12 V0
24 V–
24 V–
24 V0
Schematic circuit diagram
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail, rowed with clearances
Continuous
current
Ambient temperature
Ordering data
Combination foot for TS 15, TS 32, TS 35
1 NO
1 NC
EGR EG 7 spare relays, without connection unit
Plug-in relay-coupl., without engagem. socket, 1 changeo. cont.
Engage.socket f. plug-in relay coupler w. combin.foot TS 32, 35
Rated data of the coil
Input voltage
Rated consumption
Max. switch-on current
Combination foot for drop current
Connection
– NO and NC
– changeover contacts
Rated data der Contacts
Max. output voltage
Continuous current
Max. switch-on current
Min. switching capacity/switching current
Bounce times
Contact material2)
Bounce times
Switching times
pick up delay
drop-out delay
Service life, mechanical
–, 24 V–, 1.1 A, inductive load
–, 230 V~, 5 A, resistive load
Status indicator
Storage temperature
Ambient temperature
Insulation coordination acc. to EN 50178
Safe isolation according to VDE 0106 part 101
Rated impulse voltage
Clearances and creepage distances
Overvoltage category
Pollution severity
Accessories
Cross-connection comb. 16fold
Accessories, dimensions and connection data see
1) Serves only as a spare part for NO and NC
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
Cat. No.
8092310000
8092320000
80923300001)
8216550000
8193830000
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
Cat. No.
8216520000
8216530000
82182000001)
8216570000
8193830000
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
Cat. No.
8092340000
8092350000
80923600001)
8216580000
8193830000
12 V0 +15 % –10 %
320 mW +20 % –10 %
120 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
24 V– +15 % –10 %
280 mW +20 % –10 %
12 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
24 V– +15 % –10 %
280 mW +20 % –10 %
12 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
24 V0 +15 % –10 %
280 mW +20 % –10 %
240 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5A
8A
100 mW/10 mA
≤ 1 ms
AgNi 0.15 gold-flashed
≤ 1 ms
250 V
5A
8A
100 mW/10 mA
≤ 1 ms
AgNi 0.15 gold-flashed
≤ 1 ms
250 V
5A
8A
40 µW2)
≤ 1 ms
AgNi 0.15 5 µ Au
≤ 1 ms
250 V
5A
8A
100 mW/10 mA
≤ 1 ms
AgNi 0.15 gold-flashed
≤ 2.4 ms
≤ 8 ms
≤ 6 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
≤ 8 ms
≤ 6 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
≤ 8 ms
≤ 6 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
≤ 11 ms
≤ 10 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
DIN VDE 0106
8 kV
≥ 8 mm
III
2
DIN VDE 0106
8 kV
≥ 8 mm
III
2
DIN VDE 0106
8 kV
≥ 8 mm
III
2
DIN VDE 0106
8 kV
≥ 8 mm
III
2
QB 16/10.16
Page 304
1650330000
QB 16/10.16
Page 304
1650330000
QB 16/10.16
Page 304
2) The following ratings can safely be
b ) 5 V… 24 V dc/10 mA … 1.2 A
c ) 24 V ... 60 V dc/10 mA ... 500 mA
switched:
5A
a ) 100 mV…60 V ac/dc/100 µA…300 mA d ) 10 V…250 V ac/10 mA …
80
Cat. No.
8147120000
8147140000
81600300001)
8216560000
8193830000
1650330000
QB 16/10.16
Page 304
1650330000
After switching higher powers (b…d)
lower powers (a) can no longer be switched.
Relay Couplers in Components Housings EG 7
RST EG 7
RS EG 7
EGR EG 7
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
60 V~
Cat. No.
8092370000
8092380000
80923900001)
8216590000
8193830000
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
115 V0
Cat. No.
8092400000
8092410000
80924200001)
8216600000
8193830000
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
230 V~
Cat. No.
8092430000
8092440000
80924500001)
8216610000
8193830000
Type
EGR EG7
EGR EG7
EGR EG7
RST EG7
RS EG7
230 V~
Cat. No.
8092460000
8092470000
80924800001)
8216620000
8193830000
Type
EGR EG7
Cat. No.
8178200000
RST EG7
RS EG7
8216630000
8193830000
48 V0 +15 % –10 %
280 mW +15 % –10 %
480 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
60 V0 +15 % –10 %
280 mW +15 % –10 %
600 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
115 V0 +15 % –10 %
330 mW +15 % –10 %
160 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
230 V~ +15 % –10 %
280 mW +15 % –10 %
185 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
230 V~ +15 % –10 %
280 mW +15 % –10 %
185 mA
≤ 3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5A
8A
100 mW/10 mA
≤ 1 ms
AgNi 0.15 gold-flashed
≤ 2.5 ms
250 V
5A
8A
100 mW/10 mA
≤ 1 ms
AgNi 0.15 gold-flashed
≤ 3.8 ms
250 V
5A
8A
100 mW/10 mA
≤ 1 ms
AgNi 0.15 gold-flashed
≤ 3.8 ms
250 V
5A
8A
100 mW/10 mA
≤ 1 ms
AgNi 0.15 gold-flashed
≤ 2 ms
250 V
5A
8A
40 µW2)
≤ 1 ms
AgNi 0.15 5 µ Au
≤ 2 ms
≤ 12 ms
≤ 12 ms
≤ 12 ms
≤ 12 ms
≤ 12 ms
≤ 10 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
≤ 10 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
≤ 10 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
≤ 10 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
≤ 10 ms
> 15 x 106 switching operations
≥ 2 x 106 switching operations
with free wheel diode
> 2 x 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
DIN VDE 0106
8 kV
≥ 8 mm
III
2
8 kV
≥ 8 mm
III
2
8 kV
≥ 8 mm
III
2
8 kV
≥ 8 mm
III
2
8 kV
≥ 8 mm
III
2
QB 16/10.16
Page 304
1650330000
QB 16/10.16
Page 304
1650330000
QB 16/10.16
Page 304
1650330000
QB 16/10.16
Page 304
1650330000
QB 16/10.16
Page 304
Digital signal
processing
48 V0
1650330000
81
PLUGSERIES Relays on Sockets
PRZ/PRS
PRS/PRZ xxx 1CO
PRS/PRZ xxx 2CO
DC-Version
Type/Version
Screw connection
PRS 12Vdc LD 1CO
PRS 12Vdc LD 2CO
PRS 24Vdc LD 1CO
PRS 24Vdc LD 2CO
PRS 115Vdc LD 1CO
PRS 115Vdc LD 2CO
PRS 24Vdc LD 2CO SGR 282
with gold-plated
relay contacts:
PRS 24Vdc LD 2CO AU
Modular system comprising:
- Relay socket for mounting rails
- LED indicator unit / RC combination
- retainer clip
- pluggable relays
Independent connection technology:
screw or tension clamp technology
Compatible with low power relays type
RT / Standard with 1 or 2 CO contacts
Coil and root-contacts cross-connectable with cross-connection type
ZQV 2.5 N
Available as complete module or as
spare parts
PRZ/PRS
Tension clamp connection
PRZ 12Vdc LD 1CO
PRZ 12Vdc LD 2CO
PRZ 24Vdc LD 1CO
PRZ 24Vdc LD 2CO
PRZ 115Vdc LD 1CO
PRZ 115Vdc LD 2CO
PRZ 24Vdc LD 2CO SGR 282
with gold-plated
relay contacts:
PRZ 24Vdc LD 2CO AU
Other variants on request
Technical data
Input voltage
Rated consumption, typ
Status indicator
Output
Contact version
Max. output voltage
Max. switching current
Continuous current
Rated braking capacity
Service life, mech.
Input/output
Clearance and creepage path
Protective separation
Dielectric strength
Insulation coordinates acc. to
EN 50178
Miscellaneous data
Ambient temperature
Protection class
Rated cross-section
Flammability
Relay type
Dimensions WxHxT
Approvals
Rail mounted
Accessories
Cross-connection
2-pole
black
2-pole
red
2-pole
blue
Marking tags
AC-Version
Cat. No.
8536471001
8536501001
8530621001
8530631001
8536510000
8536520000
8596000000
10
10
10
10
10
10
10
8561760000
10
8536571001
8536591001
8530691001
8530701001
8536610000
8536630000
8595970000
10
10
10
10
10
10
10
8552440000
10
12 V dc ... 24Vdc ... 115Vdc
400 mW
pluggable LED-housing,
green LED
1 CO /2 CO contacts
1 x UM / 2 x UM
250Vuc
16A / 2 x 8A
10A
4kVA / 2 x 2kVA
30 x 106
> 8mm
DIN VDE 0106 T. 101
> 4kV eff
III / 2
-40°C ... +50°C
IP 20
0.5...2.5mm2
V0
Schrack RT1 / RT2
15.2 x 91 x 85
CE, UL recognized, cUL
TS 35
ZQV 2.5N/4-2 SW1784270000 60
ZQV 2.5N/4-2 RT 1784280000 60
ZQV 2.5N/4-2 BL 1784290000 60
WS 10/5
WS 15/5
82
Qty.
1060860000
1609880000
Type/Version
Screw connection
PRS 24Vac LD 1CO
PRS 24Vac LD 2CO
PRS 120Vac LD 1CO
PRS 120Vac LD 2CO
PRS 230Vac LD 1CO
PRS 230Vac LD 2CO
8536530000
8536560000
8530641001
8530661001
8530671001
8530681001
10
10
10
10
10
10
with gold-plated
relay contacts:
PRS 120Vac LD 2CO AU
PRS 230Vac LD 2CO AU
8595960000
8595990000
10
10
Tension clamp connection
PRZ 24Vac LD 1CO
PRZ 24Vac LD 2CO
PRZ 120Vac LD 1CO
PRZ 120Vac LD 2CO
PRZ 230Vac LD 1CO
PRZ 230Vac LD 2CO
8536651001
8536681001
8530710000
8530720000
8530731001
8530741001
10
10
10
10
10
10
8575940000
8575950000
10
10
with gold-plated
relay contacts:
PRZ 120Vac LD 2CO AU
PRZ 230Vac LD 2CO AU
Other variants on request
Technical data
Input voltage
Rated consumption, typ
Status indicator
Output
Contact version
Max. output voltage
Max. switching current
Continuous current
Rated braking capacity
Service life, mech.
Input/output
Clearance and creepage path
Protective separation
Dielectric strength
Insulation coordinates acc. to
EN 50178
Miscellaneous data
Ambient temperature
Protection class
Rated cross-section 0.5 mm2
Flammability
Relay type
Dimensions WxHxT
Approvals
Rail mounted
Accessories
Cross-connection
2-pole
black
2-pole
red
2-pole
blue
Marking tags
Cat. No.
Qty.
24Vac ...120Vac ... 230Vac
760 VA
pluggable LED-housing,
green LED
1 CO /2 CO contacts
1 x UM / 2 x UM
250Vuc
16A / 2 x 8A
10A
4kVA / 2 x 2kVA
5 x 106
> 8mm
DIN VDE 0106 T. 101
> 4kV eff
III / 2
-40°C ... +50°C
IP 20
0.5...2.5mm2
V0
Schrack RT1 / RT2
15.2 x 91 x 85
CE, UL recognized, cUL
TS 35
ZQV 2.5N/4-2 SW1784270000 60
ZQV 2.5N/4-2 RT 1784280000 60
ZQV 2.5N/4-2 BL 1784290000 60
WS 10/5
WS 15/5
1060860000
1609880000
PLUGSERIES Relays on Sockets
Accessories
marking field
retaining-clip
87 (PXZ35)
87
95 (PXS35)
Cross-connection
channel
11 / 21
Cross-connections
channel
A1 / A2
92
92
Screw
connection
15,3
15.3
15.3
22
12
(NC)
22
12
(NC)
21
11
(COM)
21
11
(COM)
24
14
(NO)
24
14
(NO)
Empty base for rail mounted TS 35
Screw connection
Tension clamp connection
Type
PXS35
PXZ35
Technical data
Rated current
Rated voltage
Dielectric strength coil/contacts
Protection class
Rated cross-section
Insulation stripping length
- Screw connection
- Tension clamp connection
Ambient temperature
Flammability class UL 94
A2
A2
A1
(COIL)
Cat. No.
8536700000
Qty.
100
6 ... 24 Vdc
6 ... 24 Vdc
48 ... 60 Vdc
115 Vdc
12 ... 24 Vac
115 Vac
230 Vac
230 Vac
RC combination 120...230 VAC/DC
PLED 24 Vdc
PLED 24 Vdc red
PLED 48 Vdc
PLED 115 Vdc
PLED 24 Vac
PLED 120 Vac
PLED 230 Vac
PLED 230 Vac red
PLRC 200 nF/200Ω
8536710000
8611010000
8536720000
8536730000
8536750000
8536760000
8536780000
8611000000
8566530000
20
20
20
20
20
20
20
20
20
ZQV 2.5N/4-2SW
ZQV 2.5N/4-2RT
ZQV 2.5N/4-2BL
1784270000
1784280000
1784290000
60
60
60
Type
WS 10/5
WS 15/5
Cat. No.
1060860000
1609880000
Qty.
200
96
Pluggable cross-connectionen
14
A1
Type
PRC
8 mm
10 mm
-40°C ... +60°C
V0
Operating indication
LED indicator with free-wheeling diode
Operating indication
DC-Version
Qty.
10
10
16 A
250 V
> 4 kV
IP 20
2.5 mm2
Holding clamp
A1
(COIL)
Cat. No.
8533771001
8536691001
12
24
2-pole black
2-pole red
2-pole blue
22
*
Marking tags
10 x 5 mm
A2
21
11
*
free wheel
diode
AC-Version
A1
A2
14
12
11
24
22
21
83
Digital signal
processing
Tension
clamp
PLUGSERIES Relays on Sockets
Pluggable relay types
1 changeover contact
SCHRACK RT
Print figure/circuit diagram
Relay type RT/SGR
2 changeover contacts
Pluggable relay
12 Vdc 1 changeover contact
12 Vdc 2 changeover contacts
Type Schrack RT Cat. No.
RT 314012
4058470000
RT 424012
4058560000
24 Vdc 1 changeover contact
24 Vdc 1 changeover contact AU
RT 314024
RT 315024
4058480000
4058490000
20
20
24 Vdc 2 changeover contacts
24 Vdc 2 changeover contacts AU
RT 424024
RT 425024
4058570000
4058580000
20
20
48 Vdc 1 changeover contact
48 Vdc 2 changeover contacts
RT 314048
RT 424048
4058740000
4058750000
20
20
60 Vdc 2 changeover contacts
RT 424060
4058760000
20
110 Vdc 1 changeover contact
110 Vdc 2 changeover contacts
RT 314110
RT 424110
4058500000
4058590000
20
20
24 Vac 1 changeover contact
24 Vac 2 changeover contacts
RT 315524
RT 424524
4058510000
4058600000
20
20
115
115
115
115
Vac
Vac
Vac
Vac
1
1
2
2
changeover
changeover
changeover
changeover
contact
contact AU
contacts
contacts AU
RT
RT
RT
RT
314615
315625
424615
425615
4058520000
4058530000
4058610000
4058620000
20
20
20
20
230
230
230
230
Vac
Vac
Vac
Vac
1
1
2
2
changeover
changeover
changeover
changeover
contact
contact AU
contacts
contacts AU
RT
RT
RT
RT
314730
315730
424730
425730
4058540000
4058550000
4058630000
4058640000
20
20
20
20
Technical data
Contact number and type
Contact material
Switching current
Switching voltage
Braking capacity
Min. switching current / braking capacity
Min. braking capacity AU contact
Rated consumption
Dielectric strength Sp./Kont.
Response / drop out time:
Bounce time NO contact/normally closed contact
Mechanical service life:
Braking capacity
Miscellaneous data
Protection class
Flammability class UL
Ambient temperature
Weight
Approvals
84
DC coil
AC coil
DC coil
AC coil
1-pole DC 13
2-pole DC 13
2-pole AC 15
DC coil
AC coil
1 changeover contact or 2 changeover contacts
AgNi 90/10, AgNi 0.15 htv
16 A 1We/2 x 8 A 2We
250 V ac
4 kVA
10 mA /100 mW
40 µW
400 mW dc/0.55 VA ac
5 kV
typ. 7/3 ms
9/45 ms
typ. 1/3 ms
> 30 x 106 switching operations
> 30 x 106 switching operations
1.25A, L/R = 80 ms 2.3 x 105
1.25A, L/R = 80 ms 2.8 x 105
1.2A, cosL/R = 0.3 6050x
IP 40
V0
-40°C ... +85°C
-40°C ... +70°C
14 g
UL, CSA, VDE, ÖVE
Qty.
20
20
PLUGSERIES Relays on Sockets
ELESTA SGR
Relais with manual operation
Type ELESTA SGR Cat. No.
SGR 662 24 Vdc T 8550510000
24 Vdc 2 changeover contacts with test button
SGR 282 24 Vdc T
24 Vdc 1 normally-open contact
Technical data
Contact number and type
Contact material
Switching current
Peak inrush current
Switching voltage
Braking capacity
Min. switching current / braking capacity
Rated consumption
Dielectric strength Sp./Kont.
Response / drop out time:
Bounce time NO contact/normally closed contact
Mechanical service life:
Miscellaneous data
Protection class
Flammability class UL
Ambient temperature
Weight
Approvals
8550520000
Qty.
10
Type Schrack RP 3SL
DC coil
DC coil
DC coil
250 Vac
4 kVA
10 mA /100 mW
500 mW
5 kV
typ. 10/3 ms
typ. 0.5/5 ms
> 30 x 106 switching operations
IP 40
V1
-25°C ... +70°C
20 g
SEV, UL, CSA, DEMKO, VDE, PTB
8588510000
20
1 normally-open contact
AgSnO2
25 A
120 A / 20 ms
250 V
4 kVA
500 mW
4 kV
typ. 8/2 ms
typ. 2 ms
30 x 106 switching operations
IP 40
-40°C ... +70°C
18 g
SEV, UL, CSA, VDE
Contact service life
Type Load
switch. oper.
RP3SL 12 A, 250 V~, cosϕ=1
3x105
RP3SL TV 8
25x103
RP3SL 2500 W, 230 V~, halogene lamps >104
RP3SL 1000 W, 250 V~, glow lamps
2.3x105
RP3SL 3000 W, 250 V~, glow lamps
3.6x104
RP3SL 1500 VA, flurescent tubes 163 µF 104
Regulation
UL 508
Power relay RP 3SL
Electrical life
Operations
Leistungsrelais Type RT2
2 changeover contacts
Qty.
10
RP3SL 24 Vdc 1NO
2 changeover contacts with test button
AgCuNi
16 A 1We/2 x 8 A 2We
Cat. No.
85
Digital signal
processing
Pluggable relay
24 Vdc 1 changeover contact with test button
RP 3SL
Relays for high switching currents
Relay Couplers on Sockets MICROSERIES in Terminal Format
MICRORELAY
MRS/MRZ
This module can be used as a universal
interface between the controller and actuator
for switching small to medium-sized loads.
MRS 5 Vdc 1CO
MRS 12 Vdc 1CO
MRZ 5 Vdc 1CO
MRZ 12 Vdc 1CO
Schematic circuit diagram
Pluggable cross-connection in the input
and output reduces wiring costs
6-mm width
Flexible thanks to screw and tension
clamp connection versions
Ordering data
for TS 35
Screw connection
Tension clamp connection
Limit diagram
Output current [A]
Type
Cat. No.
MRS 12 Vdc 1CO 8556070000
MRZ 12 Vdc 1CO 8556140000
5 Vdc ± 20 % (4...6 V)
12 Vdc ±20 % (9.6...14.4 V)
38 .5 mAdc ±10 %
193 mW ±10%
3.2 V / 21.6 mA
1.6 V / 8 mA
Green LED
6.2 ms
3.9 ms
5V
17.2 mAdc ±10 %
210 mW ±10%
6.4 V / 8.4 mA
2.5 V / 2.4 mA
Green LED
5.8 ms
6.9ms
12 V
yes
yes
yes
yes
yes
yes
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
Approvals
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Insulation coord.- and voltage proof, input/output mounting rail
Achieved clearances and creepage distances
300 V
4 kV (1.2 / 50 µs)
III
2
4 kVeff / 1 min
≥ 5.5 mm
300 V
4 kV
III
2
4 kVeff / 1 min
≥ 5.5 mm
Technical data
Input
Input voltage
Input voltage ac with UNenn
Input voltage dc with UNenn
Input power
Making threshold , (typ.)
Cut-out threshold (typ.)
Status indicator
Reaction time at UN (typ.)
Release at UN (typ.)
Voltage of relay coil
Output
Switching voltage
ac: continuous current/switching power (see derating diagram)
Switch-on current
dc: Continuous current/switching power
Min. braking capacity
Contact material
Mechanical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Climate
Ambient temperature [°C]
86
Cat. No.
MRS 5 Vdc 1CO 8556080000
MRZ 5 Vdc 1CO 8556150000
Functionality
Operating indication
Reverse polarity protection
Free wheel diode
Current temperature-rise curve
Type
Relay Couplers on Sockets MICROSERIES in Terminal Format
MRS 24 Vdc 1CO
MRS 24 Vuc 1CO
MRS 48 Vuc 1CO
MRS 60 Vdc 1CO
MRS 120 Vuc 1CO MRS 230 Vac 1CO
MRZ 24 Vdc 1CO
MRZ 24 Vuc 1CO
MRZ 48 Vuc 1CO
MRZ 60 Vdc 1CO
MRZ 120 Vuc 1CO MRZ 230 Vac 1CO
Type
Cat. No.
Type
Cat. No.
Type
Cat. No.
Type
Cat. No.
Type
Cat. No.
Type
Cat. No.
MRS 24 Vuc 1CO8556050000
MRZ 24 Vuc 1CO 8556120000
MRS 48 Vuc1CO 8556040000
MRZ 48 Vuc1CO 8556110000
MRS 60 Vdc1CO 8556060000
MRZ 60 Vdc1CO 8556130000
MRS 120 Vuc 1CO 8556030000
MRZ 120 Vuc 1CO 8556100000
MRS 230 Vac1CO8556020000
MRZ 230Vac1CO 8556090000
24 Vdc ± 20 % (19.2...28.8 V)
48 Vuc ±10% (43.2...52.8 V)
5 mA ±20 %
4 mA ±20 %
190 mW ±20 %
29 V / 2.2 mA
11 V / 1.3 mA
Green LED
6.1 ms
5.8 ms
48 V
60 Vdc ±20% (48...72 V)
120 Vuc +10% / -15% (102...132 V)
3.5 mAac ±15 %
230 Vac ±10% (207...253 V)
7.6 mA ±15%
6.6 mAdc ±10 %
160 mW ±10%
15.4 V / 4 mA
6.5 V / 1.2 mA
Green LED
6.6 ms
5.8 ms
24 V
24 Vuc ±10% (21.6...26.4 V)
11 mA ± 10 %
6.4 mA ±20 %
154 mW ±10 %
15.8 V / 3.6 mA
7 V / 1.3 mA
Green LED
7.3 ms
9 ms
24 V
3.3 mAdc ±20 %
200 mW ±10 %
35 V / 1.6 mA
11 V / 0.6 mA
Green LED
5.9 ms
6.5 ms
60 V
0.42 VA ±15 %
71 V / 1.8 mA
22 V / 0.5 mA
Green LED
6.7 ms
8.1 ms
60 V
1.55 VA ±15 %
103 V / 5 mA
49 V / 2.5 mA
Green LED
13 ms
11 ms
24 V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
–
–
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
1 changeover contact
250 V ~ acc. to VDE
240 V ~ acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
1 changeover contact
250 V ~ acc. to VDE
240 V ~ acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
1 changeover contact
250 V ~ acc. to VDE
240 V ~ acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
≥ 5.5 mm
300 V
4 kV
III
2
4 kVeff / 1 min
≥ 5.5 mm
300 V
4 kV
III
2
4 kVeff / 1 min
≥ 5.5 mm
300 V
4 kV
III
2
4 kVeff / 1 min
≥ 5.5 mm
300 V
4 kV
III
2
4 kVeff / 1 min
≥ 5.5 mm
300 V
4 kV
III
2
4 kVeff / 1 min
≥ 5.5 mm
Digital signal
processing
MRS 24 Vdc 1CO 8533640000
MRZ 24 Vdc 1CO 8533660000
87
Relay Couplers on Sockets MICROSERIES in Terminal Format
Accessories
Tension clamp version MRZ
Screw version MRS
92 mm
91 mm
94 mm
93 mm
6.1 mm
6.1 mm
General technical data
Clampable conductor:
Solid H07V-U
mm2
Fsolid H07V-K
mm2
„f“ with ferrules acc. to DIN 46 228/1*
mm2
„f“ with ferrules with plastic collar*
mm2
Max. clampable range in mm2 /gauge pin acc. to IEC 60 947-1 Size
0.5…2.5
0.5…2.5
0.5…1.5
0.5…1.5
0.13…2.5
Rated torque
Continuous current of cross-connection 2-pole
Continuous current of cross-connection multipole
Insulation stripping length
Protection class
Housing material
Flammability class UL 94
Rated current
Rated voltage
10
10
10
IP 20
Wemid
V0
6A
250 V
Cross-connection
Pluggable cross-connection
ZQV
Markings
12 x 6 mm
Screwdriver
88
A
A
mm
Tension clamp version
0.5…4
0.5…2.5
0.5…1.5
0.5…1.5
0.13…4
A2
A3
0.6 Nm
10
10
7
IP 20
Wemid
V0
6A
250 V
Type
yellow
Screw version
Cat. No.
Qty.
Type
Cat. No.
Qty.
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 GE
3 GE
4 GE
10 GE
41 GE
1758250000
1762630000
1762620000
1758260000
1758270000
60
60
60
20
10
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 GE
3 GE
4 GE
10 GE
41 GE
1758250000
1762630000
1762620000
1758260000
1758270000
60
60
60
20
10
red
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 RT
3 RT
4 RT
10 RT
41 RT
1793950000
1793980000
1794010000
1794040000
1794070000
60
60
60
20
10
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 RT
3 RT
4 RT
10 RT
41 RT
1793950000
1793980000
1794010000
1794040000
1794070000
60
60
60
20
10
blue
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 BL
3 BL
4 BL
10 BL
41 BL
1793960000
1793990000
1794020000
1794050000
1794080000
60
60
60
20
10
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 BL
3 BL
4 BL
10 BL
41 BL
1793960000
1793990000
1794020000
1794050000
1794080000
60
60
60
20
10
black
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 SW
3 SW
4 SW
10 SW
41 SW
1793970000
1794000000
1794030000
1794060000
1794090000
60
60
60
20
10
ZQV
ZQV
ZQV
ZQV
ZQV
4N
4N
4N
4N
4N
/
/
/
/
/
2 SW
3 SW
4 SW
10 SW
41 SW
1793970000
1794000000
1794030000
1794060000
1794090000
60
60
60
20
10
Cat. No.
1060960000
1061160000
Qty.
200
200
Cat. No.
1060960000
1061160000
Qty.
200
200
Cat. No.
9008330000
Qty.
10
Cat. No.
9008330000
Qty.
10
Type
WS 10/6
WS 12/6
Type
SD 0.6 x 3.5 x 100
Type
WS 10/6
WS 12/6
Type
SD 0.6 x 3.5 x 100
Relay Couplers on Sockets MICROSERIES in Terminal Format
Accessories
acc. to
Pluggable relay
Coil voltage 5 V, 1 changeover contact
Coil voltage 12 V, 1 changeover contact
Coil voltage 24 V, 1 changeover contact
Coil voltage 48 V, 1 changeover contact
Coil voltage 60 V, 1 changeover contact
Coil voltage 24 V, 1 changeover contact, 5 µAU
Type NAIS APE...
… 30005V
… 30012V
… 30024V
… 30048V
… 30060V
… 30124V
Cat. No.
4061580000
4061610000
4060120000
4061620000
4061630000
4061590000
Qty.
20
20
20
20
20
20
Coil voltage 60 V, 1 changeover contact, 5 µAU
… 30160V
4061600000
20
Technical data (of relay manufacturer)
Contact number and type
Contact version
Switching current
Switching voltage / max. Switching voltage
Braking capacity
Contact material
Recommended min. load
Typ. bounce time NO contact
Typ. bounce time normally closed contact
1 changeover contact
Single contact
6A
300 Vdc / 400 Vac
1500 VA
AgSnO2
≥ 100 mA, 12 V
1 ms
5 ms
Miscellaneous data
Flammability class UL
Ambient temperature
Max. switching operations with rated load / without load
Response / drop out time
Bounce time NO contact / normally closed contact
Protection class Housing
V-0
-40 ... +85 °C
6/1200 switching operations per minute
5 / 2.5 ms
1.5 / 5 ms
IP 67
For further data see also
Digital signal
processing
switch. operations
switch. operations
Contact service life
Material AgSnO2
www.matsushita.de
89
Relay Couplers on Sockets RS 30
1 NC, 1 NO
or 1 changeover contact
Schematic circuit diagram
1
Rated data
Input voltage 5…60 V ± 10%; 115 V/230 V + 5% – 15%
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay (at 20 °C)
Drop-out current of the relay (at 20 °C)
Pick-up current
Max. output voltage
Continuous current
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance x 20 mm
5 VTTL
0.45 W1)
–
–
–
–
250 V
5A
12 V–
0.45 W
–
3 mA
–
–
250 V
6A
2
24 V–
0.45 W
–
3 mA
–
12 mA
250 V
6A
24 V0
0.45 W
0.7 VA
2.5 mA–
3.5 mA~
–
250 V
6A
3
48 V–
0.45 W
–
2 mA
–
10 mA
250 V
6A
48 V0
0.45 W
0.6 VA
2.5 mA–
4.5 mA~
–
250 V
5A
60 V–
0.45 W
–
1 mA–
–
–
250 V
5A
115 V~
–
0.8 VA
–
1 mA~
6 mA
250 V
5A
4
115 V–
0.82 W
–
2 mA–
–
4.3 mA
250 V
5A
230 V~2)
–
0.8 VA
–
1 mA~
–
250 V
3A
240 V~
–
1.2 VA
0.5 mA–
1 mA~
–
250 V
3A
Continuous current
Continuous operation
Clearance > 20 mm
Continuous
current
48 V~/230 V~/240 V~
On/off switch. mode
< 1 min (50/50 %)
Ambient temperature
Switch-on current
Switching capacity with resistive load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Storage temperature
Ambient temperature
–, mounted on rail without clearance
–, mounted on rail with clearance ≥ 20 mm
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Mounting width
Length (perpendicular to mounting rail)
Height TS 32/TS 35 x 7.5
8A
2000 VA/100 W
250 mW/10 mA
≤ 3 ms
≤ 8 ms
≤ 8 ms
≤ 8 ms
≤ 7 ms
≤ 7 ms
≤ 7 ms
70 Hz
70 Hz
70 Hz
AgNi, gold-flashed
>107 switching operations
> 5 x 105 switching operations
>7 x 105 switching operations
–40 °C…+60 °C
≤ 12 ms
≤ 11 ms
70 Hz
–25 °C…+40 °C
–25 °C…+50 °C
III
2
11.2 mm NO/NC, 25 mm changeover contacts
70 mm (74 mm BL/SL version)
56 mm/51.5 mm
1)
2)
90
≤ 8 ms
≤ 16 ms
30 Hz
Rated consumption with 24 VDC auxilary voltage.
230 V– on request
≤ 13 ms
≤ 12 ms
20 Hz
≤ 12 ms
≤ 11 ms
70 Hz
≤ 9 ms
≤ 8 ms
30 Hz
≤ 12 ms
≤ 11 ms
70 Hz
≤ 10 ms
≤ 9 ms
30 Hz
≤ 10 ms
≤ 9 ms
30 Hz
Relay Couplers on Sockets RS 30
RS 30
RS 30
RS 30
RS 30 TTL
Screw connection
Screw connection
Disconnect plug with
Disconnect plug with
1 NO
1 changeover contact
screw connection
screw connection
1 changeover contact
1 NO and 1 NC
1 NC
6
7
8
Ordering data
Connection method
Screw connection (LP)
Schematic circuit diagram
1
2
3
4
5
6
7
8
8
Contact
NO
NO
NC
NC
changeo. c.
changeo. c.
changeo. c.
NO
NC
1167760000
1167660000
Input
voltage
5 V–, TTL
12 V–
24 V–
24 Vb
48 V–
48 Vb
60 V–
115 V–
115 V~
230 V~
240 V~
Disconnect plug with screw connection (BL/SL)
Digital signal
processing
5
Function
indicator
None
None
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
1129660000
1129421001
1101661001
1101611001
1101621001
1129521001
1100961001
1100911001
1100921001
1101761001
1101711001
1101721001
1101861001
1101811001
1101821001
1181511001
1181521001
1101061001
1101011001
1101021001
1101161001
1101111001
1101121001
1101961001
1101911001
1101921001
1102061001
1102011001
1102021001
1155161001
1155111001
1155121001
1100260000
1100210000
1100220000
1100360000
1100460000
1100410000
1100420000
1101261001
1101211001
1101221001
1100560000
1100660000
1100610000
1100620000
1155261001
1155211001
1155221001
1102161001
1102111001
1102121001
1102261001
1102211001
1102221001
1128561001
1128511001
1128521001
1101461001
1101411001
1101421001
1101561001
1101511001
1101521001
1128661001
1128611001
1128621001
1100760000
1100860000
91
Relay Couplers on Sockets RS 30
RS 31
1 changeover contact
with power contacts
Usable for high switching-power
Suitable for switching inductive loads
Schematic circuit diagram
Type
RS 31, 24 V–
RS 31, 24 V–
RS 31, 24 V–
Ordering data
Rated data
Input voltage
Rated consumption – (W)
Rated consumption – (VA)
Drop-out current of the relay (at 20 °C)
Drop-out current of the relay (at 20 °C)
Max. output voltage
Continuous current
Derating curve
mounted horizontally on rail without clearance
Cat. No.
1128361001
1128331001
1128311001
Type
RS 31, 48 V–
Cat. No.
1150761001
Type
RS 31, 115 V–
Cat. No.
1150361001
Type
RS 31, 115 V~
Cat. No.
1150461001
24 V–, ±10 %
1W
–
11.5 mA–
–
250 V
16 A
48 V–, ±10 %
1W
–
13.5 mA–
–
250 V
16 A
115 V–, +5 % –15 %
1W
–
5.5 mA–
–
250 V
16 A
115 V~, +5 % –15 %
–
1 VA
–
1.5 mA~
250 V
16 A
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 3 ms
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
< 9 ms
< 10 ms
< 12 ms
< 8 ms
< 10 ms
< 12 ms
< 4 ms
< 11 ms
AgCdO
3 x 107 switching operations
2.5 x 105 switching operations
1128361001
1128331001
1128311001
–40 °C…+60 °C
–25 °C…+40 °C
AgCdO
3 x 107 switching operations
2.5 x 105 switching operations
1150761001
AgCdO
3 x 107 switching operations
2.5 x 105 switching operations
1150361001
AgCdO
3 x 107 switching operations
2.5 x 105 switching operations
1150461001
–40 °C…+60 °C
–25 °C…+40 °C
–40 °C…+60 °C
–25 °C…+40 °C
–40 °C…+60 °C
–25 °C…+40 °C
III
2
III
2
III
2
III
2
25 mm
70 mm
58 mm/53.5 mm
25 mm
70 mm
58 mm/53.5 mm
25 mm
70 mm
58 mm/53.5 mm
25 mm
70 mm
58 mm/53.5 mm
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
– 230 V, 50 Hz, 3.5 kV A
Status indicator
Storage temperature
Ambient temperature
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Mounting width
Length (perdendicular to mounting rail)
Height with TS 32/TS 35 x 7.5
92
Red LED
Yellow LED
Green LED
Relay Coupler on Locking Socket Profile RS 31
RS 31
with power contacts
Type
RS 31, 230 V~
RS 31, 230 V~
RS 31, 230 V~
Cat. No.
1128461001
1128431001
1128411001
Digital signal
processing
230 V~, +5 % –15 %
–
1 VA
–
2.2 mA~
250 V
16 A
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
< 10 ms
< 8 ms
AgCdO
3 x 107 switching operations
2.5 x 105 switching operations
1128461001
1128431001
1128411001
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
58 mm/53.5 mm
93
Relay Couplers on Sockets RS 32
with 2 changeover contacts
RS 32
RS 32
Schematic circuit diagram
9406021001
Ordering data
Type
RS 32
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay** (at 20 °C)
Drop-out current of the relay** (at 20 °C)
Max. output voltage
Continuous current
Derating curve
mounted horizontally on rail without clearance
Cat. No.
9406021001
Type
RS 32
9406121001
9406321001
9406521001
Cat. No.
9406121001
Type
RS 32
Cat. No.
9406221001
Type
RS 32
Cat. No.
9406321001
12 V–, ±10 %
0.6 W
–
9.5 mA
–
250 V
2x4A
24 V–, ±10 %
0.6 W
–
5 mA
–
250 V
2x4A
24 V0, ±10 %
0.6 W
0.9 VA
24 V–: 4.5 mA
24 V~: 2.5 mA
250 V
2x4A
48 V–, ±10 %
0.6 W
–
2 mA
–
250 V
2x4A
2x6A
1400 VA
2x6A
1400 VA
2x6A
1400 VA
2x6A
1400 VA
≤ 4 ms
≤ 4 ms
≤ 4 ms
≤ 4 ms
≤ 13 ms
≤ 10 ms
≤ 13 ms
≤ 10 ms
≤ 13 ms
≤ 10 ms
≤ 13 ms
≤ 10 ms
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
CSA
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
CSA
III
2
III
2
III
2
III
2
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Status indicator
Storage temperature
Ambient temperature
Approvals
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Mounting width
Length (perpendicular to mounting rail)
Height with TS 32/TS 35 x 7.5
94
Relay Couplers on Sockets RS 32
RS 32
Type
RS 32
Cat. No.
9406421001
Type
RS 32
Cat. No.
9406521001
Type
RS 32
Cat. No.
9406621001
1122661001
1122761001
Type
RS 32
Cat. No.
9406721001
Type
RS 32
Cat. No.
1122661001
Type
RS 32
Cat. No.
1122761001
48 V0, ±10 %
0.6 W
0.9 VA
48 V–: 2 mA
48 V~: 4.5 mA
250 V
2x4A
60 V–, ±10 %
0.6 W
–
1.5 mA
–
250 V
2x4A
115 V0, +5 % –15 %
0.5 W
0.6 VA
115 V–: 1 mA
115 V~: 1.5 mA
250 V
2x4A
230 V0, +5 % –15 %
1W
1 VA
230 V–: 1.2 mA
230 V~: 2 mA
250 V
2x4A
24 V/48 V0, ±10 %
0.5 W/0.6 W
0.7 VA/0.9 VA
–: 5 mA/2 mA
~: 3 mA/4.5 mA
250 V
2x4A
115 V/230 V0, +5 % –15 %
0.5 W/1 W
0.6 VA/1 VA
–: 1 mA/1.2 mA
~: 1.5 mA/2 mA
250 V
2x4A
2x6A
1400 VA
2x6A
1400 VA
2x6A
1400 VA
2x6A
1400 VA
2x6A
1400 VA
2x6A
1400 VA
≤ 4 ms
≤ 4 ms
≤ 4 ms
≤ 4 ms
≤ 4 ms
≤ 4 ms
≤ 13 ms
≤ 10 ms
≤ 10 ms
≤ 10 ms
≤ 13 ms
≤ 10 ms
≤ 13 ms
≤ 10 ms
≤ 13 ms
≤ 10 ms
≤ 13 ms
≤ 10 ms
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
AgNi0.15, gold-flashed
> 30x106 switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
III
2
III
2
III
2
III
2
III
2
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
25 mm
70 mm
68 mm/63.5 mm
95
Digital signal
processing
9406221001
9406421001
9406621001
9406721001
Multiple Socket Interface RSM
(Relay Coupler)
RSM 4 R
with one changeover contact each
RSM 4 RS
Also available as opto-coupler (max. 48 V),
See page 120/121
Schematic circuit diagram
Rated data
Input voltage
Rated consumption –(W)
Rated consumption ~(VA)
Pick-up current – (mA)
– (mA)
Pick-up current ~ (mA)
– (mA)
soldered relay
plug-in relay
soldered relay
plug-in relay
soldered relay
plug-in relay
soldered relay
plug-in relay
Drop-out current of the relay (at 20 °C)
Max. output voltage
Continuous current
Derating-curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance ≥ 20 mm
RSM 8 R
4 relays, soldered
8 relays, soldered
RSM 8 RS
4 relays, plug-in
8 relays, plug-in
Fixing feet can also be mounted turned through 180°
DC voltage, positive switching
24 V–
0.45 W
0.55 W
–
–
12 mA
23 mA
–
–
24 V0
0.45 W
–
0.5 VA
–
–
12 mA
–
16.5 mA
48 V–
0.45 W
0.55 W
–
–
10 mA
14 mA
–
–
48 V0
0.45 W
–
0.6 VA
–
–
–
–
–
115 V~
–
–
0.6 VA
0.6 VA
–
–
–
5 mA
115 V0
–
–
0.6 VA
0.6 VA
5 mA
–
6 mA
–
230 V~
–
–
0.9 VA
1.2 VA
–
–
–
4 mA
230 V0
–
–
0.9 VA
1.2 VA
3 mA
–
3.5 mA
–
2 mA
250 V
6A
250 V
6A
1.5 mA
250 V
6A
250 V
6A
1 mA
250 V
6A
250 V
6A
1 mA
250 V
3A
250 V
3A
≤ 10 ms/12 ms
≤ 15 ms/20 ms
≤ 3 ms
8A
2000 VA
≤ 10 ms
≤ 10 ms
≤ 3 ms
8A
2000 VA
≤ 8 ms/10 ms
≤ 5 ms/8 ms
≤ 3 ms
8A
2000 VA
≤ 10 ms
≤ 10 ms
≤ 3 ms
8A
2000 VA
≤ 8 ms/10 ms
≤ 7 ms/8 ms
≤ 3 ms
8A
2000 VA
Continuous
current
Ambient temperature
Switching times, typical
–, pick-up lag (–/~)
–, turn off delay (–/~)
Bounce times
Switch-on current
Switching capacity with resistive load
Min. switching capacity/switching current
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Storage temperature
Ambient temperature
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Conductor cross-section (screw connection)
Spare relay (pluggable)
for 24 V-RSM types
for 48 V-RSM types
for 115 V, 230 V-RSM types
96
≤ 8 ms
≤ 10 ms/10 ms ≤ 12 ms
≤ 7 ms
≤ 15 ms/20 ms ≤ 11 ms
≤ 3 ms
≤ 3 ms
≤ 3 ms
8A
8A
8A
2000 VA
2000 VA
2000 VA
250 mW/10 mA
AgNi 90/10, AgNi0,15, gold-flashed
> 30x106 switching operations
>5 x 105 switching operations
>7 x 105 switching operations
–40 °C…+60 °C
–25 °C…+50 °C
III
2
0.5…2.5 mm2
Input voltage
24 V–
24 V–
48 V–
48 V–
115 V–
115 V–
115 V–
Contact material
AgNi 90/10
AgNi 90/10
AgNi 90/10
AgNi 90/10
AgNi 90/10
AgNi 90/10
Au 5
Cat. No.
8630780000
4058480000
8630790000
4058740000
8630770000
4058500000
4156970000
Notes
RT 314024 with yoke
RT 314024 without yoke
RT 314048 with yoke
RT 314048 without yoke
RT 314110 with yoke
RT 314110 without yoke
ZLT input relay KHU/BV 1680
Multiple Socket Interface RSM
RSM 16 RS
16 relays, plug-in
Red LEDs, further colours on request
Ordering data
Connection technology
Input/output
Ribbon cable/
Screw connection
Male connector block with interlock
according to DIN 41651/Parts 1 and 2
Input
voltage
24 VDC
AC-DC/DC voltage
RSM 4 R/RS RSM 8 R/RS RSM 16 R/RS Positve
4 relays
8 relays
16 relays
switching1)
Relay
pluggable
–
Relay
pluggable
11133610013)
11134610013)
11135610013)
11136610013)
11137610013)
11138610013)
1173461001
1173561001
1173661001
24 VDC
Screw connection
• Input:
- Relay pluggable
Screw connection and
male conn. block acc. to
IEC 603-1/ DIN 41651
- Relay soldered
male conn. block acc. to
IEC 603-1/ DIN 41651
• Output: Screw connection
Negative
switching2)
24 V0
48 VDC
1113961001
1114061001
1114161001
1114261001
1114361001
1114461001
1173761001
48 V0
Relay
soldered
1113161001
1100061001
1113261001
1100161001
80175810014)
1112361001
1112761001
• 80036710014) • 1107761001
•
1112661001
• 80182210014) • 1107861001
•
1113061001
Mounted
width
145 mm
145 mm
285 mm
285 mm
75 mm
75 mm
145 mm
145 mm
285 mm
285 mm
75 mm
145 mm
285 mm
1112461001
75 mm
75 mm
145 mm
145 mm
285 mm
285 mm
75 mm
•
•
•
•
115 V0
1114561001
1114661001
1114761001
75 mm
145 mm
285 mm
230 V~
1114861001
1114961001
1115061001
75 mm
145 mm
285 mm
75 mm
145 mm
285 mm
230 V0
1123461001
1108061001
1108261001
Digital signal
processing
DC voltage, negative switching
Spare relays
on request
1)
2)
Common negative potential, positive is switched
Common negative potential, negative is switched
3)
4)
Approval by the Germanischer Lloyd
Empty modules without relays
97
Relay Socket Module for Industry Relays
Weidmüller relay sockets for mounting rails
enable plug-in relays most commonly
used in industry to be mounted; they
make possible installations in which the
control section and power section are perfectly separated. The coil terminals and
the connection terminals are located on
opposite sides of the locking socket modules.
The conductors are connected via screw
terminals; the securing in the terminal is
achieved by a clamping yoke system. This
method has been used by Weidmüller for
many years, and is the only method that
guarantees a reliable connection in industrial applications.
Thanks to their combination foot, these
modules can be mounted onto TS 32, TS
35x7.5, TS 35x15 mounting rails in accordance with European standards EN 50035
and EN 50022.
The connections are marked according to
European Standard EN 50005. The modules are designed for DC relays (with a
damping diode parallel to the coil, as well
as a protection diode for reverse polarity
protection) and AC relays.
They can be provided with an LED on
request.
The contacts available at the output are:
2, 3 or 4 changeover contacts.
The marking of the contacts in the following diagram corresponds to European
standard EN 50005.
The standard range of relay socket modules is divided as follows:
DC voltage
Ac voltage
The input terminals are doubled, in order
to pick off the poles. Note the following for
DC current operation:
A1 = +
A2 = –
98
Group 1:
RS 3 (2 changeover contacts)
RS 4, RS 14 (4 changeover contacts)
For relays of the type “international”
Group 2:
RS 6 (2 changeover contacts)
Size 1
RS 7, 17 (3 changeover cont.)
Size 2
RS 8, 18 (4 changeover cont.)
Size 2
RS 9 (2 changeover cont.)
Size 2
For relays of the type "European".
Relays with 4 changeover contacts (size 2)
can be secured to RS 7, RS 17 and RS 9;
however, only 3 or 2 changeover contacts
are connected to the terminals, which
results in space savings.
Group 3: RS 21 (2 changeover contacts)
RS 23 (3 changeover contacts)
RS 24 (2 x 3 changeover cont.)
For relays with one socket with 8 or 11
pins.
The table on page 87 offers an overview of
the most important manufacturers of
relays in groups 2, 3 and 4. The list is provided for information purposes only, and
does not claim to be complete
List of Plug-in Relays for Weidmüller Relay Socket Modules
Group 1
International relays
Group 2
European relays
Group 3
Relays with socket oktal
• RS 3 2 changeover contacts
• RS 4, RS 14 4 changeover contacts
• RS 6 2 changeover contacts (Size 1)
• RS 7, RS 17 3 changeover cont. (Size 2)
• RS 8, RS 18 4 changeover cont. (Size 2)
• RS 9 2 changeover cont. (Size 2)
Relay type
•
–
• Type 40701
• Type 40701
• RS 21 2 changeover contacts
• RS 23 3 changeover contacts
• RS 24 2x3 changeover contacts
Relay type
•
•
–
–
ELESTA
•
•
–
–
FEME
•
•
–
–
GRUNER
•
•
–
–
HALLER
•
•
–
–
ITT (MTI)
• MAT 2
• MAT 4
FUJITSU
• FRL 263-02
• FRL 263-04
KUHNKE
•
• Type 111 A4
–
KUKE
•
•
–
–
NATIONAL
• HC 2
• HC 4
OMRON
• MY 2
• MY 4
POTTER & BRUMFIELD
•
• Series KH
–
RAPA
•
•
–
–
Tyco/SCHRACK
• ZT 4
• PT 4
SDS
• HC 2
• HC 4
TEC
•
• Type 1301
–
ZETTLER
•
• TEC 1401
–
•
•
•
•
•
•
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
Series
Series
Series
Series
Series
Series
9065 G
9059 G/9066 G
9059 G/9066 G
9059 G/9066 G
H-561 Size 1
H-561 Size 2
Relay type
•
• Type 41454
• Type 41454
–
• SKR 085
• SKR 115
• RCP 8
• RCP 11
• RCP 11
• Series 668 B 2 changeover contacts
• Series 668 A 3 changeover contacts
• Series 668 A 3 changeover contacts
• HB-1/1
• HB-1/2
• Series H-561 Size 2
• Series H-561 Size 2
• Type 24
• HB-1/2
•
–
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
–
–
Type 25
Type 25
Type 25
–
–
–
–
–
–
–
–
Miniature
Miniature
Miniature
Miniature
relays
relays
relays
relays
Type
Type
Type
Type
01
02
02
02
–
–
–
–
MHS-2
MHS-4
MHS-4
MHS-4
• Universal relays-M/-H/-U
• Universal relays-M/-H/-U
• Universal relays-M/-H/-U
•
•
•
–
–
–
•
•
•
–
–
–
• MK 2
• MK 3
• MK 3
–
Series R 10
Series R 10
Series R 10
Series 012 Size 1
Series 012 Size 2
Series 012 Size 2
Series 012 Size 2
Relays N, S, W Size 1
Relays N, S, W Size 2
Relays N, S, W Size 2
Relays N, S, W Size 2
K2
K4
K4
K4
Type 1350
Type 1360
Type 1360
Type 1360
AZ E 20, AZ 420, AZ 420
AZ E 21, AZ 421, AZ 421
AZ E 21, AZ 421, AZ 421
AZ E 21, AZ 421, AZ 421
• FRL 256-02
• FRL 256-04
• FRL 256-04
Digital signal
processing
Manufacturer
EBERLE
• Series KAP
• Series KAP
• Series KAP
• Series C-Type CKR
• Series C-Type CKR
• Series C-Type CKR
• Series RN/RC
• Series RN/RC
• Series RN/RC
• Type 1210
• Type 1210
• Type 1210
W
W
W
W
• AZ 1010 – AZ 509 2 C
• AZ 1010 – AZ 509 3 C
• AZ 1010 – AZ 509 3 C
99
Relay Sockets for Industry Relays
PT 4 industry relays
4-pole, with test button
Rated data
Contact data
Contact number and type
Contact version
Contact material
Max. braking capacity AC
Rated voltage
Continuous current
Switch-on current
Min. contact rating
4 changeover contacts
Single contacts
AgNi 90/10, AgNi 90/10 htv
1500 VA
250 V~
6 A / contact
12 A / contact
24V, 10 mA / 20 m, 1 mA htv
DC coil > 30x106
AC coil > 20x106
15/10 ms
5 ms
2.5 kVeff coil / contact
B, 60 V~/75 V
250 V
2
III
B/250
VDE, UL, CSA
Mechanical service life
Response / drop out time
Bounce time
Test voltage
Isolation acc. to IEC664
Rated voltage
Pollution severity
Overvoltage category
Insulation group / reference voltage
Approvals
Miscellaneous data
Protection class
Flammability class UL 94
Ambient temperature
DC coil
AC coil
Weight
IP50
V-0
-40 … + 70 °C
-40 … + 70 °C
30g
Correspond. relay socket
• Relay sockets Type RS 3, RS 4 and RS 14
• Alternatives to ZT 4 see table on page 99
6
12
24
48
60
115
V–
V–
V–
V–
V–
V–
Type (ZT 4)
PT 570006
PT 570012
PT 570024
PT 570048
PT 570060
PT 570110
Best.-Nr
8074650000
8054360000
1180700000
8074670000
8074680000
8074700000
6
12
24
48
60
115
230
V~
V~
V~
V~
V~
V~
V~
PT
PT
PT
PT
PT
PT
PT
8074710000
8074730000
1181800000
1180900000
8074760000
1180800000
1181100000
Ordering data
Retainer clip for SIEMENS-Relays
100
570506
570512
570524
570548
570560
570615
570730
PT 28800
8572170000
Relay Sockets for Industry Relays
RS 3
RS 4
RS 14
Relay sockets for DC and AC
voltage relays
0125661001
Relay type*
Contacts on module
Ordering data
Relay socket for AC relays
(without diode)
With red LED (230 V~)
Relay socket for DC relays
with suppressor diode and reserve voltage protection
(diode 1 N 4007)
With red LED (24 V–)
With green LED (24 V–)
Dimensions
Relay socket width
Insulation stripping length
Connection data
Screw connection, solid
Screw connection, flexible
Conductor cross-section
Rated data
Coil voltage (types without LED)
Contact voltage
Contact current
Accessories
Mounting rail (2 m lenghts)
End bracket (thickness mm)
Insert tag (blanc)**
Protective strip, transparent**
Retainer clip for Schrack relays
Sockeltyp
Schrack
Type PT 5
4-pole
Schrack
Type PT 5
4-pole
Schrack
Type PT 5
4-pole
2 changeover contacts
4 changeover contacts
4 changeover contacts
RS 3
0115161001
RS 4
0116261001
RS 14
0125561001
Digital signal
processing
with fixing foot for TS 32/TS 35x7.5 and TS 35x15
1157561001
0115061001
0116161001
0125661001
0116121001
1127661001
0115011001
8025451001
35 mm
7 mm
65 mm
7 mm
45 mm
7 mm
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
250 V0
250 V~
5A
Type
TS 32
TS 35x7.5
TS 35x15
EWK 2
EW 35
ESo 7
SSt 7
ZG 28800
250 V0
125 V~
5A
Cat. No.
0122800000
0383400000
0498000000
0199360000
0383560000
0515200000
0515300000
0116000000
250 V0
125 V~
5A
Type
TS 32
TS 35x7.5
TS 35x15
EWK 2
EW 35
ESo 7
SSt 7
ZG 28800
Qty.
–
–
–
50
50
–
100
25
Cat. No.
0122800000
0383400000
0498000000
0199360000
0383560000
0515200000
0515300000
0116000000
Qty.
–
–
–
50
50
–
100
25
* Relay not included in delivery
101
Relay Sockets for Industry Relays
Relay socket for DC and AC voltage relays
with locking foot
for TS 32
TS 35x7.5
and TS 35x15
RS 6
Assigning commercially available relays to the
Weidmüller relay sockets RS 6...RS 24:
• Relay socket RS 6
Siemens cradle relay, size I
Zettler cradle-operated relay AZ 420
RAPA range 012, size 1
• Relay socket type RS 7, RS 8, RS 9, RS 17
and RS 18
Siemens cradle relay, size II
Zettler cradle-operated relay AZ 421
RAPA range 012, size II
• Relay socket type RS 21, RS 23 and RS 24
Siemens/Schrack Universal
Industry relay RS/RN/RC
Siemens industry relay 10
Kuhnke universal relay
Zettler industrial relay AZ 1010
RAPA range C
0115461001
RS 6
RS 8
RS 9
RS 17
RS 18
0126061001
(No claim is made that this is a complete list of manufacturers of relays or types of relays.)
Relay type*
Ordering data
Relay socket for AC relays
(without diode)
Socket type
Relay socket for DC relays
with suppressor diode and reserve voltage protection
(diode 1 N 4007)
With red LED (24 V–)
Kamm-R.®
Gr. I
Kamm-R.®
Gr. II
Kamm-R.®
Gr. II
Kamm-R.®
Gr. II
Kamm-R.®
Gr. II
Kamm-R.®
Gr. II
2 changeov. c. 3 changeov. c. 4 changeov. c. 2 changeov. c.
(e. g. B 104) (e. g. B 110) (e. g. B 110) (e. g. B 104)
RS 6
RS 7
RS 8
RS 9
0115361001
3 changeov. c. 4 changeov. c.
(e. g. B 110) (e. g. B 110)
RS 17
RS 18
0115261001
0125861001
0115461001
0116361001
0188961001
0126061001
0126011001
With green LED (24 V–)
Dimensions
Relay socket width
Insulation stripping length
Connection data
Screw connection, solid
Screw connection, flexible
Conductor cross-section
35 mm
7 mm
50 mm
7 mm
65 mm
7 mm
35 mm
7 mm
35 mm
7 mm
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2 0.5…4 mm2
0.5…2.5 mm2 0.5…2.5 mm2
AWG 26…14 AWG 26…14
Rated data
Coil voltage (types without LED)
Contact voltage
Contact current
Accessories
Mounting rail (2 m lenghts)
250 V0
250 V~
5A
Type
TS 32
TS 35x7.5
TS 35x15
EWK 2
EW 35
ESo 7
SSt 7
250 V0
250 V~
5A
250 V0
125 V~
5A
Cat. No.
0122800000
0383400000
0498000000
0199360000
0383560000
0515200000
0515300000
250 V0
250 V~
5A
50 V0
125 V~
5A
Type
TS 32
TS 35x7.5
TS 35x15
EWK 2
EW 35
ESo 7
SSt 7
End bracket (thickness mm)
Insert tag (blanc)**
Protective strip, transparent**
Retainer clip for Schrack relays
* Relay not included in delivery
102
Qty.
–
–
–
50
50
–
100
45 mm
7 mm
250 V0
125 V~
5A
** Not suitable for RS 12
Cat. No.
0122800000
0383400000
0498000000
0199360000
0383560000
0515200000
0515300000
Qty.
–
–
–
50
50
–
100
Relay Coupler, Relay Sockets Module for Industry Relays
RS 21
RS 23
RS 24
0167161001
Plug-in relay for
Octal socket
8-pole
Plug-in relay for
submagnal socket
11-pole
RS 21
on request
RS 23
8010061001
RS 24
on request
0167161001
0188661001
on request
35 mm
7 mm
40 mm
7 mm
75.5 mm
7 mm
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
250 V0
250 V~
6A
Type
TS 32
TS 35x7.5
TS 35x15
EWK 2
EW 35
ESo 7
SSt 7
250 V0
250 V~
6A
250 V0
250 V~
6A
Cat. No.
0122800000
0383400000
0498000000
0199360000
0383560000
0515200000
0515300000
Digital signal
processing
2 changeov. c. 3 changeov. c. 2 x 3 changeov. c.
Qty.
–
–
–
50
50
–
100
103
Opto-coupler
104
Opto-coupler
- low power uptake on control side
- high switching frequency
- no contact bounce
- wear-free switching
- insensitive to vibration
- use independent of location
- no mechanical parts
- long life
- high insulation voltage
Because of these features, opto-coupler
are an alternative to conventional, mechanical relay interfaces.
For industrial usage, Weidmüller offers
modules with various input voltages and
housings.
Basic construction of the opto-coupler To eliminate these effects where possible,
interface:
Weidmüller opto-coupler use almost
exclusively semiconductors which have a
The heart of the system is the optolong life in terms of CTR.
electronic component (opto-coupler) that
effects the coupling.
Moreover, the insulation of a module is
highly important, since the actual coupling
of the input and output circuits takes
place optically. Thus the optical
component has to guarantee separation of
Input from
Output to
both circuits even in case of a defect.
control
periphery
Weidmüller opto-coupler comply with
DIN VDE 0884 to provide a maximum level
of safety.
Sender
Receiver
An important parameter of this type of
modules is the CTR = current transfer
rate.
Appropriate switching circuits need to be
included to ensure that the entire component provides reliable separation in
accordance with DIN VDE 0106,
Part 101.
The CTR is given in % and is the ratio
between the input current IF and the
maximum available output current IC.
Example: IF = 10 mA; CTR = 100%
=> IC = 10 mA.
The CTR is affected by a number of
parameters such as:
- Ambient temperature
- efficiency of the luminescence diode
- geometric dimensions within the module
Circuit diagram of an opto-coupler
It also drops with time. The result is that
the switching levels change due to ageing.
Opto-coupler for protective separation
or galvanic isolation
The most important precondition for
achieving protective separation with optoelectronic coupling modules is the partial
discharge test in accordance with DIN
VDE 0884. Double or reinforced insulation
for protective separation must be discharge proof. High voltage tests, as are
usual with relays, cannot be carried out
with semi-conductors, because they could
lead to the destruction of the semi-conductor. Safe separation for the given rated
voltage is applicable to coupling modules
that are integrated into opto-couplers if:
CTR
in %
- the opto-couplers are tested according
to DIN VDE 0884
CTR as a function of operating life
t (Life time)
- clearance and creepage distances on
the PCB and connection elements correspond to EN 50 178, DIN VDE 0106
and 0109.
105
Digital signal
processing
With increasing automation, potential
separation between the control and field
sides of circuits is becoming increasingly
important. The control unit being the core
of the automation must be electrically safe
and free from feedback when coupled with
the various sensors and actuators. Optocoupler are being used in a growing number of applications. They offer the necessary safety and have further advantages
such as:
Opto-coupler
Control side of the opto-coupler
interface
3 basic circuits are to be differentiated on
the input side of the opto-coupler#s interface:
- as a pure DC input with polarity protection diode wich prevents the opto-coupler from being destroyed if the input
polarity is reversed.
- as an AC/DC input:
Wrong polarity of the DC input signal is
not possible with this switching.
The disadvantage of an AC/DC input circuit (driven by DC signal) is the low
switching rate since the charging capacitor
(CL, necessary for AC-input signal) lowers
the max. switching rate.
- pure AC-Input:
* Sample circuit
Here, too, the charging capacity lowers
the max. switching rate considerably.
Weidmüller opto-coupler with AC/DC
or AC input signals are designed for
40…60 Hz power supply.
With AC-signal input the max. switching
rate is below half the power supply
frequency.
A high switching rate is not possible, otherwise continuous switching in tune with
the power frequency would occur.
106
Output side of the opto-coupler
Weidmüller opto-coupler are designed and
sized for a wide variety of applications.
Demands regarding the load side of optocouple modules could be:
- power amplification
- signal conditioning
AC/DC, DC/AC
- short-circuit protection
- interference proof, etc.
To fulfil these requirements, the opto-coupler must contain additional electronic
components which determine the functionality of the opto-coupler.
Thus there are 2 basic output variations
for opto-coupler
Output as
- 2 pole and
- 3 pole circuits
2-pole DC output
* Wiring example
The 2-pole DC output is comparable to a
conventional switch. With this type it is
immaterial where the load is in the output
circuit. It is, however, important to provide
the necessary output supply voltage with
the right polarity.
Opto-coupler
2-pole AC output
Zero voltage switch
Sample circuit
A special semiconductor element (TRIAC)
in the output stage of the opto-coupler is
used to switch AC voltages.
As for the DC-versions the appropriate
parameters (such as voltage, frequency,
max. load current, ambient temperature)
should be given consideration.
A neutral voltage switch ensures that the
load is switched only in the voltage zero.
To protect against voltage spikes, the
modules are allways fitted with appropriate
protection elements (varistors, RC-combination).
To prevent decoupling of interference
signals to other leads the load side
should be protected.
Protection
Standards
Weidmüller opto-coupler comply with the
following standards:
Protective circuit for DC output
EN 50 178
Furnishing of power engineering systems
with electronic equipment
DIN VDE 0106 Part 101
Protection against flow of dangerous
currents into the human body; basic
requirements for reliable separation within
electrical equipment.
DIN VDE 0884
Optoelectronic coupling devices for reliable Protective circuit for AC output
separation
Application example
DIN VDE 0109
Insulation coordination within low-voltage
PLC
Inputs
Inputs
system including clearance and creepage
distances for equipment
Protection
Opto-coupler output
Optoc-oupler input
Digital signal
processing
The derating curve shows the dependency
of the output current as a function of the
Ambient temperature (see under the
respective product on the following
pages).
This type of output stage requires for safe
function a potential-linked output voltage
supply with an output that is either positive
switching (common reference potential is
GND or 0 V) or negative switching
(common reference potential is the positive
voltage pole).
All opto-coupler have a protective circuit in
the output (generally a free-wheeling
diode).
Load
The load current should not be higher than
the stated max. output current.
Continuously exceeding this value will
destroy the output stage.
Protective circuit
Load
Opto-couplers are normally given with an
3-pole DC output
output voltage supply from 5…48 VDC.
These values should not be cut or exceeded on any occasion.
PLC
Opto-coupler output
Opto-coupler input
Namurinitiator
Actuator, e. g.
solenoid
Monitoring an actuator
Position monitoring
with namur intiator
107
Types of housing for opto-coupler
Weidmüller coupler modules are enclosed
in housings that are appropriate for
industrial applications. The housings are
suitable for fitting onto mounting rails
TS 32, TS 35 x 7.5 or TS 35 x 15 in
accordance with European Standards
EN 50 035 and EN 50 022.
Component housing EG
Weidmüller component housings EG 1
and EG 2 are 18 mm wide. The fully
enclosed EG housings are fitted with
clamping yoke screw connections or
push-on blade connectors for attaching
wires. Conductors with the following
cross-sectional dimensions can be connected:
solid conductors:
0.5…4 mm2 or
flexible conductors: 0.5…2.5 mm2.
The component housing EG 7 has a special status. Is has been specifically
designed to accommodate 10-mm slim
opto-couplers.
EG 7 opto-coupler modules can be
mounted onto TS 32 or TS 35 rails.
The RS EG7 locking socket is also available for the OST opto-couplers.
The fully-enclosed EG 7 housing is fitted
with clamping yoke connections.
Conductors with the following crosssections can be connected:
Component housing EG7: 0.5…1.5 mm2
Locking socket:
0.5…2.5 mm2.
108
Component Housing WAVEBOX
Component housing WAVEBOX
It is important for modern electronics to
create a functional housing. Setting and
operating functions must be guaranteed,
technical demands regarding heat dissipation and EMC properties are to be supported. The ideal design saves space and
mounting costs in the switchgear cabinet.
Moreover, ergonomics and the design are
gaining in importance for high-quality
opto-couplers interfaces. The WAVEBOX
fulfils these criteria and has the following
distinguishing features:
The WAVEBOX is characterised by:
• Optimal width for any application
(12.5 mm, 17.5 mm, 22.5 mm)
• Large component assembly surface;
SMD’s can be mounted on the solder
side
• No tools required for assembly
• Plug-in printed circuit board
• Plug-in cross-connection via ZQV 2.5 N
• Hinged, transparent cover
• BLZ 5.08 screw/plug and socket
connector
• BLFZ 5.08 optional tension clamp/plug
and socket connector
• Marking option with WS tags
• Suitable for snap-fitting on TS 35
Connection systems
Available are BLZ screw-type connectors
as well as the BLZF tension clamp system
for up to 2.5 mm2 flexible conductors for
maximum wiring flexibility.
Printed-circuit board removal
This takes place by pushing in the locking
hooks in way of the cover and with drawing of the terminal level and printed circuit
board from the housing. This must not
take place with the supply connected.
Cross-connection
Housings of the same family arranged side
by side, can be cross-connected in the
base of the housing with the ZQV 2.5 N/2
cross-connector. The cross-connection
can be loaded with a current of up to 8 A.
By means of this arrangement, the supply
voltage can be cross-connected from one
electronic module to another. The voltage
transferred from the cross-connection to
the terminal level must not exceed 50 V.
Air vents
Slanted air vents control the temperature
and ventilate the housing base.
Modular system
PLUGSERIES/PLUGOPTO
is a new generation of pluggable SSR.
The core is an innovative relay socket
PXS or PXZ.
Both products combine Weidmüller
functionality and experience gained from
the relay and terminal business.
The PLUGopto is the ideal connection
technology between SSR and the
application.
Modular principle
The new PLUGSERIES is particularly service friendly. Commercially available SSRs
are simply plugged: holding / dismounting
clamps guarantee secure mounting; LED
indicators with free-wheeling diode can be
simply plugged.
• Easy plugging of SSR
- suitable for the standard design
and RT
• Independent connection technology:
screw or tension clamp
Rated cross-section 0.5 2.5 mm2
• Robust holding / dismounting clamp
• Control voltage 24 Vac/Vdc
• Rated switching voltage 24 Vdc, 24
Vac/Vdc, 230 Vac
• Up to 5 A continuous current
• Low wiring costs thanks to ZQV 2.5N
(pluggable) cross-connectors
• Service-friendly modular system
- relay socket, LED indicator
- holding clamp and SSR
- mount onto TS 35
- marking options with WS marking
tags and holding clamps
• Pluggable LED indicator with free-wheeling diode
Mini-coupler
Miniconditioner MCZ
The locking socket with opto-couplers RS
40 have a width of 11.2 mm. The modules
on locking socket profiles are equipped
with clamping yoke (screw connection)
units for conductor connection.
Connectable are:
solid conductors: 0.5…4 mm2
flexible conductors: 0.5…2.5 mm2.
All parts of the mini-coupler DKR and DKO
meet the specifications for a design that is
as slim as possible. The sensational width
of a mere 6 mm can be achieved by
employing the latest surface-mounted
devices (SMD). There are 4 or 5 screw
connections available which accept
conductors with cross-sectional
dimensions from 0.5…4 mm2. The minicoupler offer a wide range of options for
coupling digital sensor/actuator signals
between automation devices and the
process stage. With DKO opto-coupler,
signals from the field with different voltages can be picked up and unified.
The MCZ-housing is distinguished as one
of the slimest component-housings. A tool
width of only 6 mm reduces space
requirements in cabinets.
The MCZ is characterized by:
- Tension-clamp connection
- integrated cross-connection option for
input and output minimise wiring costs.
The mini conditioner MCZO (opto-couplers) have 4 and 5 Z-tension spring connections. The clampable conductor crosssection is 0.5...1.5 mm2.
Locking socket with multiple
interfaces
Multiple interfaces RSM are optionally
available assembled with 4, 8 or 16 pluggable opto-couplers. Versions are available with joint positive and negative potentials in order to reduce wiring on the input
side.
PCB clamping yoke screw connecter elements have clamping yoke units for connecting conductors with the following
cross-sections:
solid conductors: 0.5...4 mm2
flexible conductors: 0.5...2.5 mm2
Digital signal
processing
Weidmüller locking socket RS
Variants of the RSM couplers have male
connector blocks on the input side for
connecting pre-assembled cables, in
accordance with IEC 603-1/DIN 41651.
CE-marking
Weidmüller opto-coupler are marked with
the CE symbol and comply with the
requirements of
EN 50 081 Part 1 and EN 50 082 Part 2.
They can therefore be used for both
industrial as well as for commercial and
light industry.
Appropriate ESD measures should be
taken during installation. If connecting
wires are particularly long, overvoltage
protection should be provided in order to
prevent interference from electrical
disturbance in the atmosphere.
109
Opto-coupler
Electronic switching
Output
24 V
4x
5 - 48 V
≤ 20 mA
Housing
EG
0558160000
Page 122
5 - 48 V
≤ 0.1 A
5 - 48 V
≤ 0.5 A
5 - 48 V
≤ 20 mA
5 - 48 V
≤ 2.5 A
0609860000
5 - 48 V
≤5A
24 - 250 V
≤ 3.5 A
5 - 48 V
≤ 0.1 A
8x
5 - 48 V
≤ 0.1 A
16 x
5 - 48 V
≤ 0.1 A
8220870000
Page 123
Page 130
WAVESERIES
8275190000
WOS
8237720000
Page 126
EG 7
8269050000
Page 131
Page 128
8281720000
Page 131
8092530000
8234580000
Page 132
RS 40
1160961001
1117461001
1161761001
8065031001
1177860000
Page 137
1119460000
Page 137
RSM
1123861001
1124261001
1124661001
1123761001
1125261001
8018220000
1125161001
8003671001
1124900000
8017581001
1124900000
1170200000
1153200000
1124900000
1170200000
1170200000
1153200000
1121300000
1153200000
1121300000
8082471001
1121300000
8021391001
1124900000
Page 139
1124900000
1170200000
1170200000
1153200000
1153200000
1121300000
1121300000 Page 139
Page 139
DKO 32
8008090000
8019580000
Page 116
DKO 35
Page 117
8008150000
8019590000
Page 116
Page 117
8028300000
8215630000
8215600000
8181990000
Page 118
Page 118
8215640000
8248790000
Page 117
DKO 35/32
8228640000
8228630000
Page 119
MCZ O
8365940000
Page 114
Page 118
8398940000
Page 115
8287730000
Page 114
8324610000
(5 V TTL)
Page 115
PLUGSERIES
POS/POZ
8610840000
8610860000
8610920000
8610930000
8610900000
8610910000
8610970000
8610980000
8610890000
8615590000
8610960000
8615630000
8615600000 Page 134
8615640000
8615620000
8615650000
Page 134
Reliable
separation
110
24 V dc
24 Vuc/ac
Replacement opto-coupler dc and ac/dc
Empty socket
Opto-coupler
Electronic switching
Output
48 V
4x
5 - 48 V
≤ 20 mA
Housing
EG 7
5 - 48 V
≤ 0.1 A
5 - 48 V
≤ 0.5 A
5 - 48 V
≤ 20 mA
5 - 48 V
≤ 2.5 A
5 - 48 V
≤5A
24 - 250 V
≤ 3.5 A
5 - 48 V
≤ 0.1 A
8x
5 - 48 V
≤ 0.1 A
16 x
5 - 48 V
≤ 0.1 A
8092550000
Page 132
8234590000
Page 132
RS 40
1161061001
Page 137
1161860000
Page 137
DKO 35
8151230000
Page 120
Output
115 V
4 xx
4
5 - 48 V
≤ 20 mA
Housing
EG
5 - 48 V
≤ 0.1 A
5 - 48 V
≤ 0.5 A
5 - 48 V
≤ 20 mA
5 - 48 V
≤ 2.5 A
5 - 48 V
≤5A
24 - 250 V
≤ 3.5 A
5 - 48 V
≤ 0.1 A
8 xx
8
5 - 48 V
≤ 0.1 A
16 xx
16
5 - 48 V
≤ 0.1 A
0131860000
Page 123
8235180000
WOS
Page 125
EG 7
8296250000
Page 126
8259950000
Page 127
8275360000
Digital signal
processing
WAVESERIES
Page 128
8092570000
8234600000
8397420000
8315590000
Page 133
RS 40
1161161001
1161960000
Page 137
DKO 32
8027980000
Page 119
DKO 35
8077860000
Page 119
8131660000
Page 120
MCZ O
8421060000
Page 114
Reliable
separation
Vdc
Vuc/ac
111
Opto-coupler
Electronic switching
Output
230 V
4x
Housing
EG
5 - 48 V
≤ 20 mA
5 - 48 V
≤ 0.1 A
5 - 48 V
≤ 0.5 A
5 - 48 V
≤ 20 mA
5 - 48 V
≤ 2.5 A
5 - 48 V
≤5A
24 - 250 V
≤ 3.5 A
5 - 48 V
≤ 0.1 A
0546360000
Page 123
WAVESERIES
8275380000
WOS
Page 125
EG 7
8092590000
8234610000
8387580000
8394990000
Page 133
RS 40
1161461001
1162060000
8182690000
Page 137
DKO 32
8008100000
Page 119
DKO 35
8008160000
Page 119
MCZ O
8421380000
Page 114
230 Vuc/ac
112
8275220000
Page 126
8275400000
Page 127
8275340000
Page 128
8x
5 - 48 V
≤ 0.1 A
16 x
5 - 48 V
≤ 0.1 A
Opto-coupler
Electronic switching
Output
12 V
4x
5 - 48 V
≤ 20 mA
Housing
EGO
8011250000
Page 122
5 - 48 V
≤ 0.1 A
5 - 48 V
≤ 0.5 A
5 - 48 V
≤ 20 mA
5 - 48 V
≤ 2.5 A
5 - 48 V
≤5A
24 - 250 V
≤ 3.5 A
5 - 48 V
≤ 0.1 A
8x
5 - 48 V
≤ 0.1 A
16 x
5 - 48 V
≤ 0.1 A
0114260000
Page 122
WAVESERIES
8275500000
WOS
Page 124
EGO 7
8092510000
8234570000
Page 132
RS 40
1118760000
1161660000
Page 137
RSM O
8017581001
8003671001
8018221001
1121200000
1121200000
1121200000
1124800000
1124800000
1124800000
Page 139
8021391001
8082471001
1121200000
1121200000
1124800000
Page 139
DKO 35
1124800000
Page 139
8184030000
Page 116
3…60 V
EGO, 3…5 V
0266160000
Page 122
EGO, 3…12 V
8011250000
Page 122
WAVESERIES
8275430000
WOS 5 V
Page 124
WAVESERIES
Digital signal
processing
8275210000
WOS 5 V TTL
Page 129
WAVESERIES
8275390000
WOS 3.5 - 15 V
Page 124
WAVESERIES
8275450000
WOS 12 - 28 V
Page 129
WAVESERIES
8237730000
WOS 15 - 60 V
Page 124
EGO, 7.5 V
8237730000
Page 124
8275440000
Page 127
8092490000
8234560000
Page 132
RS 40, 5 V
1118861001
1161560000
Page 137
RSM, 5 V
1123661001
1124061001
1124461001
1121100000
1121100000
1121100000
Page 139
DKO 32
Page 139
Page 139
8018620000
Page 116
DKO 35
8018630000
Page 116
DKO 32/35
8067100000
Page 120
8228650000
Page 116
Reliable
separation
12 Vdc
12 Vuc/ac
Replacement opto-coupler dc and ac/dc
Empty socket
113
Opto-coupler in component housing mini coupler MCZ
Opto-couplers MCZ O
MCZ O
24 Vac/dc 20 mA
MCZ O
24 Vac/dc 2 A2*
MCZ O
120 Vac/dc
MCZ O
230 Vac
Output current
Derating curve
rated to ambient temperature
a+b at Uin
a = rowed without clearances on the mounting rail
b = rowed with clearances ≥ 20 mm
Ambient temperature
28 Vac/dc
126 Vac/dc
2A
241.50 Vac
26.4 Vac/dc
b
a
50 mA
b
a
20 mA
40 50 °C
50°C
20 mA
40 50 °C
50°C
Schematic circuit diagram
This module can be used:
• between controller and sensor, for feedback of
different statuses.
• for direct switching of load currents up to a Adc, but
also provides “online” information about the
behaviour of the load current.
The MCZ-O modules do have following features:
• Reduction of installation- and power-up times by
using the proved tension-clamp technology
• Pluggable cross-connection units in the input side
reduce wiring costs
• 6 mm width
Ordering data
For TS 35
Technical data
Input
Input voltage
Making threshold
Input current at Unom
Rated input consumption
Max. input frequency
Capacity working resistance to reduction at dissipated energy
Functionality
Output
Supply voltage
Max. output current
Voltage drop at max. load current
Pulse duration, limiting overload current (not periodic)
Reverse current (close-circuit current) at Uout = 48 V
Reverse polarity protection
Free-wheel diode
- typ. Switch-on delay (at ac phase position dependent)
- typ. Switch-off delay (at ac phase position dependent)
Short-circuit proof
Insulation coordin./Reliable separation acc. to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Insulation coordin.- and voltage proof, input/output mounting rail
Opto-coupler
Ambient temperature rowed on mounting rail without clearances
Ambient temperature rowed with clearances ≥ 20 mm
Storage temperature
Conductor
Conductor cross-section
Approvals
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
114
Type
Cat. No.
MCZ O 24 Vac/dc
8365940000
Type
Cat. No.
MCZ O 24 Vac/dc
8287730000
Type
Cat. No.
MCZ O 120 Vac/dc
8421060000
Type
Cat. No.
MCZ O 230 Vac
8421380000
24 Vac/dc ±10 % (21.6...26.4ac/dc)
24 Vac/dc ±20 % (19.2...28.8ac/dc)
ac: 14.1 Vac / dc: 16.8 Vdc
ac: 11.4 mA / dc: 9.6 mA
approx.16 Vac/dc
ac: 13 mA / dc: 12 mA
ac: approx.220 mW
dc: ca.195 mW
ac: ≤10 Hz duty factor 1:2
dc: ≤ 30 Hz duty factor 1:2
no
operating indication
120 Vac/dc -15 % +5 %
approx.65 Vac/approx.70 Vdc
approx.3 mA
230 Vac -15 % +5 %
approx.170 Vac
ac: 10 mA
ac: 5 Hz duty factor 1:2
dc: 20 Hz duty factor 1:2
no
operating indication
ac: 5 Hz duty factor 1:2
5...48 Vdc
50 mA
< 1.6 V
< 150 mA / 10 ms
max.0.16 mA
5...48 Vdc
20 mA
< 1.6 V
< 150 mA / 10 ms
max.0.16 mA
present
≤ 30 ms
≤ 40 ms
present
300 V
6 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
6 kV
III
2
≥ 3 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+50 °C
ac: 5 Hz duty factor 1:2
dc: 10 Hz duty factor 1:2
no
operating indication
5...48 Vdc
20 mA
≤1V
< 150 mA / 10 ms
max. 0.16 mA
present
ac: ≤ 10 ms / dc: ≤ 20 ms
ac: ≤ 45 ms / dc: ≤ 40 ms
24 Vdc ±20 %
2A
(19.2...28.8 Vdc)
present
external necessary
yes
operating indication
yes
300 V
6 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+50 °C
-40 °C...+85 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
6 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
-40 °C...+85 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
Opto-coupler in component housing mini coupler MCZ
Opto-couplers MCZ O
MCZ O
24 Vdc/5 VTTL1*
MCZ O
5 V TTL/5...48 Vdc2*
Derating curve
rated to ambient temperature
a = rowed on the mounting rail without clearances
b = rowed with clearances ≥ 20 mm
This module can be used:
1* - between controller and actuator, for the signal
conversion of 24 Vdc to 5 VTTL
2* - between controller and actuator, for the signal
conversion of 5 VTTL to 5...48 Vdc
Output current
5.25 Vdc
a+b at Uin
28.8 Vdc
100 mA
8 mA
a
b
a
b
40 50 °C
40 50 °C
Ambient temperature
Schematic circuit diagram
Input signal
2 µs
Output signal
2.5 µs
at 832461
Ordering data
For TS 35
Technical data
Input
Supply voltage
Input voltage
Making threshold
Input current at Unom
Rated input consumption
Max. input frequency
Min. input impulse width
Output
Supply voltage
Output voltage
Max. output current
Voltage drop at max. load current
Pulse duration, limiting overload current (not periodic)
Reverse current (static current) at Uout = 48 V
Reverse polarity protection
Free-wheel diode
- typ. switch-on delay
- typ. switch-off delay
Insulation coordin./Reliable separation acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Insulation coordination/dielectric strength I/O to TS
Opto-coupler
Ambient temperature rowed on mounting rail without clearances
Ambient temperature rowed with clearances ≥ 20 mm
Storage temperature
Conductor
Conductor cross-section
Approvals
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
Type
Cat. No.
MCZ O 24 Vdc 8324610000
24 Vdc ±16 % (20…28 Vdc)
approx.17 Vdc
4.7 mA (2.9.2..6.5 mA)
dc: 112 mW
100 kHz switching ratio 1:2
50 kHz switching ratio 1:10
2 µs
5 V (4.75...5.25 V)
5 V TTL (4.75...5.25 V)
8 mA, Fan Out = 20 LS-TTL
Type
Cat. No.
MCZ O 24 Vdc 8398940000
5 Vdc ± 5 %
5 V TTL
Digital signal
processing
1µs
IIL = 1 µA / IIH = 8 µA
2.4 kHz
5...48 Vdc
100 mA
≤ 1.8 V
1 µs (at 20 Vdc)
2.5 µs (at 28 Vdc)
present (input)
present
approx.27 µs
approx.210 µs
300 V
6 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
300 V
6 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C...+85 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type
Cat. No.
AP MCZ 1.5
8389030000
Page 305
115
Opto-coupler in component housing mini coupler DK
Opto-couplers DKO
DKO 5 Vdc
DKO 5 VTTL
DKO 12 Vdc
DKO 24 Vac/dc
• Coupling of digital sensor-/actuator-signals between
PLC and process
• Low cost solution for level- and potential-equalization
• Low input power
• Screw clamp connection technology
• 6 mm width
Schematic circuit diagram
Switching ratio
Switching ratio
Ordering data
For TS 32
For TS 35
With combination foot TS 32/TS 35
Technical data
Input voltage
Switch-on voltage
Input current
Max. input power
Output voltage
Max. output current
Min. output current
Max. switching frequency; switching ratio 1: 2
Y
W
Type
DKO 5 Vdc
DKO 5 Vdc
Cat. No.
8018620000
8018630000
Type
Cat. No.
DKO 12 Vdc
DKO DK5 5 VTTL 8228650000
Input: bottom
5 VTTL
Input: bottom
5 Vdc ±5 %
2.4 Vdc
≤10 mA
50 mW
5…48 Vdc
20 mA
50 µA
20 Hz
Type
Cat. No.
8184030000
Type
Cat. No.
DKO 24 Vac/dc 8008090000
DKO 24 Vac/dc 8008150000
5…48 Vdc
100 mA
50 µA
3 kHz
Input: bottom
12 Vdc ±20 %
approx.7 V
11 mA
130 mW
24 Vdc ±10 %
50 mA
50 µA
10 kHz
Input: bottom
24 Vac/dc ±10 %
112.8 Vac/16.8 Vdc
11.4 mAac/9.6 mAdc
280 mVA/230 mW
5…48 Vdc
20 mA
50 µA
ac: 5 Hz dc: 10 Hz
1 µA
Switch-on delay
≤15 µs
approx.27 µs
1 µs
≤15 ms at dc
Switch-off delay
≤70 µs
approx.35 µs
2.5 µs
≤25 ms at dc
Voltage drop at max. load
≤1.6 V
≤1.6 V
≤1 V
≤1 V
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
150 V
4 kV
IV
2
≥4 mm
300 V
6 kV
IV
2
≥5.5 mm
300 V
6 kV
IV
2
≥5.5 mm
300 V
4 kV
III
2
≥4 mm
Storage temperature
Conductor
Conductor cross-section
Overall width
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
12 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Accessories
End plate
Further accessories, dimensions and connection data
Type
AP DKT4
Page 305
Operating temperature
116
without clearances
with clearances
Cat. No.
0687560000
Type
AP DK5
Page 305
Cat. No.
8268870000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Opto-coupler in component housing mini coupler DK
Opto-couplers DKO
DKO 24 Vdc
DKO 24 Vdc
DKO 24 Vdc
DKO 24 Vdc
Schematic circuit diagram
Switching ratio
Switching ratio
Type
Y
W
DKO 24 Vdc
Cat. No.
8028300000
Type
DKO 24 Vdc
Cat. No.
8215640000
Type
DKO 24 Vdc
Cat. No.
8248790000
Type
DKO 24 Vdc
DKO 24 Vdc
Technical data
Input voltage
Switch-on voltage
Input current
Max. input power
Output voltage
Max. output current
Min. output current
Max. switching frequency; switching ratio 1: 2
Input: top
24 Vdc ±10 %
approx.19 V/7.5 mA
≤15 mA
360 mW
5…48 Vdc
20 mA
50 µA
3 kHz
Input: bottom
24 Vdc ±10 %
approx.19 V/7.5 mA
≤15 mA
360 mW
5…48 Vdc
20 mA
50 µA
3 kHz
Input: bottom
24 Vdc ±10 %
approx.19 V/7.5 mA
≤8.5 mA
204 mW
5…48 Vdc
20 mA
50 µA
3 kHz
Input: bottom
24 Vdc ±10 %
approx.17 V
6 mA
145 mW
5…48 Vdc
500 mA
50 µA
200 Hz
Switch-on delay
approx.50 µs
approx.50 µs
approx.50 µs
approx.40 µs
Switch-off delay
approx.80 µs
approx.80 µs
approx.80 µs
approx.65 µs
Voltage drop at max. load
≤900 mV
≤900 mV
≤900 mV
≤800 mV
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
300 V
4 kV
II
2
≥4 mm
300 V
4 kV
II
2
≥4 mm
300 V
4 kV
III
2
≥4 mm
300 V
4 kV
II
2
≥4 mm
Storage temperature
Conductor
Conductor cross-section
Overall width
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Accessories
End plate
Further accessories, dimensions and connection data
Type
AP DKT4
Page 305
Operating temperature
without clearances
with clearances
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
8019580000
8019590000
Digital signal
processing
Ordering data
For TS 32
For TS 35
Cat. No.
0687560000
117
Opto-coupler in component housing mini coupler DK
Opto-couplers DKO
DKO 24 Vdc
DKO 24 Vdc
DKO 24 Vdc
DKO 24 Vac/dc
• Coupling of digital sensor-/actuator-signals between
PLC and process
• Low cost solution for level- and potential-equalization
• Low input power
• Screw clamp connection technology
• 6 mm width
Schematic circuit diagram
Switching ratio
Switching ratio
Mode:
Ordering data
For TS 32
For TS 35
With combination foot TS 32 / TS 35
Technical data
Input voltage
Switch-on voltage
Input current
Max. input power
Output voltage
Max. output current
Min. output current
Max. switching frequency; switching ratio 1: 2
Type
Y
W
DKO 24 Vdc
Cat. No.
8215630000
Input: top
24 Vdc ±10 %
approx.17 Vdc
6 mA
145 mW
5…48 Vdc
500 mA
50 µA
200 Hz
Type
DKO 24 Vdc
green
yellow
red
Cat. No.
8181990000
Load current ≥ 500mA
Idling
Short circuit
Type
DKO 24 Vdc
Cat. No.
Type
8215600000
Input: bottom
24 Vdc ±10 %
approx.18 Vdc
12 mA
290 mW
24 Vdc ±10 %
2A
Input: top
24 Vdc ±10 %
approx.18 Vdc
12 mA
290 mW
24 Vdc ±10 %
2A
DKO 24 Vac/dc 8228630000
Input: bottom
24 Vac/dc ± 20 %
approx.16 Vac/dc
13 mAac/12 mAdc
220 mVA/195 mW
24 Vdc ± 20 %
2A
100 Hz
100 Hz
ac: 10 Hz dc: ≤30 Hz
Switch-on delay
approx.40 µs
2 ms
Switch-off delay
approx.65 µs
7 ms
Voltage drop at max. load
≤800 mV
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature
Storage temperature
Conductor
Conductor cross-section
Overall width
300 V
4 kV
III
2
≥4 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Accessories
End plate
Further accessories, dimensions and connection data
Type
AP DKT4
Page 305
118
without clearances
with clearances
300 V
4 kV
III
2
≥3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
12 mm
Cat. No.
0687560000
Cat. No.
Type
AP DKT4
Page 305
300 V
4 kV
III
2
≥3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
12 mm
Cat. No.
0687560000
Type
AP DKT4
Page 305
300 V
6 kV
IV
2
≥5.5 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Cat. No.
0687560000
Type
AP DK 5
Page 305
Cat. No.
8268870000
Opto-coupler in component housing mini coupler DK
Opto-couplers DKO
DKO DK5 24 Vdc
DKO 115 Vac/dc
DKO 230 Vac/dc
Type
Cat. No.
DKO 115 Vac/dc 8027980000
DKO 115 Vac/dc 8077860000
Type
Cat. No.
DKO 230 Vac/dc 8008100000
DKO 230 Vac/dc 8008160000
DKO 24 Vdc
8228640000
Input: top
24 Vdc ±20 %
approx.17 Vdc
4.7 mA
112 mW
5 VTTL
8 mA, Fan Out = 20 LS-TTL
Input: bottom
115 Vac/dc +5 % -15 %
approx.65 Vac/approx.66 Vdc
2.65 mAac/3 mAdc
390 mVA/350 mW
5…48 Vdc
50 mA
100 kHz 1:2/50 kHz 1:10
ac: 5 Hz/dc: 20 Hz
Input: bottom
230 Vac/dc +5 % -15 %
approx.130 Vac/approx.140 Vdc
1.8 mAac/1.7 mAdc
395 mVA/370 mW
5…48 Vdc
20 mA
50 µA
ac: 5 Hz/dc: 20 Hz
Switch-on delay
1 µs
17.4 ms
20 ms
Switch-off delay
2.5 µs
27.4 ms
20 ms
4 mm
3.75 kVeff / 5.3 kVdc
4 kVeff
>5 mm
Operating temperature
Storage temperature
-25 °C…+50 °C
-40 °C…+60 °C
-25 °C…+50 °C
-40 °C…+60 °C
-25 °C…+50 °C
-40 °C…+60 °C
Conductor
Conductor cross-section
Overall width
AWG 22…12
0.5…4 mm2
6 mm
AWG 22…12
0.5…4 mm2
6 mm
AWG 22…12
0.5…4 mm2
6 mm
Accessories
End plate
Type
AP DKT4
120
Cat. No.
0687560000
Type
AP DKT4
Cat. No.
0687560000
Type
AP DKT4
Cat. No.
0687560000
Opto-coupler in component housing mini coupler DK
DKO switching amplifiers/opto-couplers for Namur initiators
Application example:
Signals for consumers are normally transferred
via an interface. Generally, this interface must
conform with DIN 43867 (interface for signal
transmission). There must be a differentiation
between the passive interface and active S0
interface. The actual signals, that are correspondingly proportional to the relevant consumption (electrical energy, gas consumption,
water, district heating, etc.) are shown at
measuring sensors (electric meter, etc.) The
interface itself is purely passive (acceptor) and
must be supplied via a source. The source for
providing the current is built into the active
interface. The following threshold values are
specified:
Imax = 27 mAdc
Umax = 27 Vdc
fmax = 16.66 Hz
For the recognition of the corresponding consumption signals, the following currents are
integrated:
ON (active) -> 10…27 mA
Off (inactive) -> 0…2 mA
The module accepts the input from the signal
sensor and outputs the opto-decoupled output
signal, i. e. galvanically isolated.
Ordering data
For TS 32
For TS 35
With combination foot TS 32 / TS 35
Technical data
Input
Input voltage
Input current
Pulse generator
Y
W
DKO DK4 S0
W
Schematic circuit diagram
Type
DKO DK4 S0
DKO DK4 S0
Cat. No.
8467030000
8100180000
24 Vdc ±10 %
≤13 mA
Specification acc. to DIN
43864 (current interface for
connection to pulse generator
acc. to DIN 43864)
Output
Output voltage
Output current
5…48 Vdc
max. 100 mA
Voltage proof input-output/mounting rail
4 kVeff
Insulation coordination to DIN VDE 0160, Draft 11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
300 V
6 kV
IV
2
≥5.5 mm
Storage temperature
Conductor
Conductor cross-section
Overall width
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
12 mm
Accessories
End plate
Type
AP DKT4
Operating temperature
without clearances
with clearances
DKO
Schematic circuit diagram
Ordering data
For TS 32
For TS 35
With combination foot TS 32 / TS 35
Technical data
Input
Input voltage
Input current
Reverse polarity protection
DKO
Cat. No.
8164250000
24 Vdc ±20 %
≤35 mA
up to 1 kV available
NAMUR-Input (N+ and N-)
Switching frequency
Switch-on delay
Switch-off delay
300 Hz f. pulse duty factor 1:1
approx.45 µs
approx.450 µs
Input (E+ and 0)
Switch-on point
Switch off-point
Current consumption
Max. switching frequency
Switch-on delay
Switch-off delay
approx.18 V
ca 15 V
< 5 mA
300 Hz f. pulse duty factor 1:1
approx.20µs
approx.400 µs
Output (A+ and A-)
Output voltage
Output current
Switching capacity
Internal voltage drop
Protective measure
5…30 Vdc
max. 100 mA
max. 3 W
max. 1 V
Free-wheel. diode btwn. A+…A-
Voltage proof input-output/mounting rail
Operating temperature
Cat. No.
0687560000
Type
Y
W
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
without clearances
with clearances
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
12 mm
Type
Cat. No.
AP DKT4
0687560000
121
Digital signal
processing
Opto-couplers DKO
S0 signal sensor
Opto-coupler in component housing EG
Opto-couplers EGO
EGO 1
EGO 1
5V
EGO 1
5V
EGO 1
12 V
24 V
For low voltage
alternatively positive
or negative switching
Schematic circuit diagram
Switching ratio
t1 = t2
1=1:2
Switching ratiott1 = 2
3
* Wiring option
Ordering data
Type
EGO 1, 5 V
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Cat. No.
0266160000
Type
EGO 1, 12 V
Cat. No.
8011250000 3)
Type
EGO 1, 12 V
Cat. No.
0114260000
Type
EGO 1, 24 V
3…5 V–2)
9…45 mW
–
3…12 V–
30…280 mW
–
12 V0, ±10 %
0.35 W
0.45 VA
24 V–, ±10 %
0.6 W
–
5…48 V–1)
10 ms
Relay output
1 changeover
AgCdO
5 x 106 switching operations
105 switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529 / IEC 664 / IEC 801 / IEC 255
VDE 0435/ VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
green LED
yellow LED
UL / CSA
IEC 529 / IEC 664 / IEC 801 / IEC 255
VDE 0435/ VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2 x 1.5 mm2
2 x 2.5 mm2 / 1 x 4 mm2
2 x 1.5 mm2
2 x 2.5 mm2 / 1 x 4 mm2
self extinguishing
100 g
self extinguishing
100 g
Cat. No.
8287770000
Digital signal
processing
Ordering data
149
Timers
ITR
Response delay timer relay
Schematic circuit diagram
Ordering data
Contact
Time periods
Repeat accuracy (const. parameter)
Accuracy of indication acc. to IEC 1812-1
Input
Input voltage
Voltage tolerance
Duty factor
Rated power consumption
Min pulse duration type
Max. reset time at voltage interruption
Protection against voltage interruption
Output
Contact
Contact material
Service life
- mechanical
- electrical
Switching current
- max.
- min.
Max. switching voltage
Switching current
Status indicators
Voltage applied
Relay output active
Approvals
Standards
Temperature
- Storage temperature
- Operating temperature
Clearance/creepage path. acc. to IEC 664/VDE 0110
Protection category IEC 529 - Terminal block
- Front
Mounting
Installation category to IEC 664
Connection
- with ferrule
- without ferrule
Enclosure material
Weight, typ.
150
Type
ITR
Changeover
0.1 s - 100 h
(0.1 - 1 s, 1 s - 10 s, 0.1 min. - 1 min.,
1 min. - 10 min., 0.1 h - 1 h, 1 h - 10 h, 100 h)
± 0.5%
± 10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 115% UN (110% for 240 V)
100 %
0.5 W / 24 V1.5 VA / 24 V~
12 VA / 230 V~
≥ 50 ms
≤ 100 ms
> 10 ms
Relay output
1 changeover
AgCdO
5 x 106 switching operations
105 switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529 / IEC 664 / IEC 801 / IEC 255
VDE 0435/ VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2 x 1.5 mm2
2 x 2.5 mm2 / 1 x 4 mm2
self extinguishing
100 g
Cat. No.
8362570000
Timers
Signal conditioning
DKZ/DKZA timer modules
• Components for extending
short pulses
• Provides PLC versions with
switch-on/off delay
• Fixed times
DKZ
DKZA
DKZ 24 Vac/dc
DKZA 24 Vac/dc
DKZA 24 Vac/dc
Type
Cat. No.
DKZ 24 Vac/dc 328008130000
DKZ 24 Vac/dc 35 8008190000
Type
Cat. No.
DKZA 24 Vdc 32 8008120000
DKZA 24 Vdc 35 8008180000
Type
Cat. No.
DKZA 24 Vdc 32 8020990000
DKZA 24 Vdc 35 8022110000
24 Vac/dc ±10 %
5.1 mAdc/6.1 mAac ±10 %
24 Vdc ±18 %
6.7 mA ±10 %
200 mA ±10 %
160 mW ±10 %
24 Vdc ±10 %
6.7 mA ±10 %
200 mA ±10 %
160 mW
50 ms
2 ms
150 ms
2.5 ms
Ordering data
For TS 32
For TS 35
Y
W
Technical data
Input
Input voltage
Input nominal current
Input current (at first-time power-up)
Input power
Switch-on delay
Switch-off delay
Min. pulse duration of input voltage
130 mW ±10 %/150 mVA ±10 %
1s
≤ 0.7 ms
Digital signal
processing
Schematic circuit diagram
Output
Max. output voltage
Max. output voltage
Reverse current, max. (closed-circuit current)
Max. voltage drop at max. load current
Max. switching frequency
5…48 Vdc
20 mA
≤ 0,16 mA (at 48 V)
≤1V
0.9 Hz
5…48 Vdc
20 mA
≤ 0,16 mA (at 48 V)
≤ 1.6 V
20 Hz
5…48 Vdc
20 mA
≤ 0,16 mA (at 48 V)
≤ 1.6 V
20 Hz
Isolation coordinates acc. to DIN VDE 0160, Draft11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof, input/output-TS
Operating temperature
without clearances
with clearances
Storage temperature
Total width
Conductor
Conductor cross-section
Reverse polarity protection
300 V
4 kV
III
2
≥4 mm
4 kVeff
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
ja
300 V
4 kV
III
2
≥4 mm
4 kVeff
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
ja
300 V
4 kV
III
2
≥4 mm
4 kVeff
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
ja
Accessories
End plate
Type
AP DKT4
Dimensions see
Page 305
Cat. No.
0687560000
Type
AP DKT4
Page 305
Cat. No.
0687560000
Type
AP DKT4
Cat. No.
0687560000
Page 305
151
Timers
Pulse conditioning
DKZ/DKZA timer modules
DKZ
DKZA
DKZ DK5
DKZ DK5
DKZ DK5
Schematic circuit diagram
Ordering data
For TS 32
For TS 35
With combi foot TS32/TS 35
Technical data
Input
Supply voltage
Supply current
Control voltage
Control input current
Type
DKZ DK5
Cat. No.
8228680000
Type
DKZ DK5
Cat. No.
8243780000
Type
DKZ DK5
Cat. No.
8019650000
24 Vdc ± 20 %
ca. 12 mA
24 Vdc ± 20 %
ca. 12 mA
24 Vdc ± 20 %
ca. 12 mA
Output
Output voltage
Max. output current
Internal voltage drop
Range of switch-on delay
5…48 Vdc
100 mA
≤ 1.6 V
10…100 ms (adjustable)
5…48 Vdc
100 mA
≤ 1.6 V
100 ms…1 s (adjustable)
5…48 Vdc
100 mA
≤ 1.6 V
1…100 s (adjustable)
Isolation coordinates acc. to DIN VDE 0160, Draft11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof, input/output-TS
Operating temperature
without clearances
with clearances
Storage temperature
Total width
Conductor
Conductor cross-section
300 V
6 kV
IV
2
≥ 5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
300 V
6 kV
IV
2
≥ 5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
300 V
6 kV
IV
2
≥ 5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
Accessories
End plate
Type
AP DK5
Dimensions see
Page 305
152
Cat. No.
8268870000
Type
AP DK5
Page 305
Cat. No.
8268870000
Type
AP DK5
Page 305
Cat. No.
8268870000
Timers
Signal conditioning
DKZA timer modules
• Components for extending short pulses
• Provides PLC versions with switch-on/off
delay
• Fixed times
DKZA DK5
DKA DK5
DKZA DK5
Schematic circuit diagram
Type
DKZA DK5
Cat. No.
8228690000
Type
DKZA DK5
Cat. No.
8243770000
Type
DKZA DK5
Cat. No.
8019630000
24 Vdc ± 20 %
ca. 11 mA
24 Vdc ± 20 %
ca. 0.5 mA
2 ms
24 Vdc ± 20 %
ca. 11 mA
24 Vdc ± 20 %
ca. 0.5 mA
2 ms
24 Vdc ± 20 %
ca. 11 mA
24 Vdc ± 20 %
ca. 0.5 mA
2 ms
5…48 Vdc
100 mA
≤ 1.6 V
10…100 ms (adjustable)
5…48 Vdc
100 mA
≤ 1.6 V
100 ms…1s (adjustable)
5…48 Vdc
100 mA
≤ 1.6 V
1…100 s (adjustable)
Isolation coordinates acc. to DIN VDE 0160, Draft11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof input/output-TS
Storage temperature
Operating temperature
without clearances
with clearances
Total width
Conductor
Conductor cross-section
300 V
6 kV
IV
2
≥ 5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
300 V
4 kVeff
IV
2
≥ 5.5 mm
6 kV
-40…+85 °C
-25…+40 °C
-25…+50 °C
6 mm
AWG 22…12
0.5…4 mm2
300 V
4 kVeff
IV
2
≥ 5.5 mm
6 kV
-40…+85 °C
-25…+40 °C
-25…+50 °C
6 mm
AWG 22…12
0.5…4 mm2
Accessories
End plate
Type
AP DK5
Dimensions see
Page 305
Cat. No.
8268870000
Type
AP DK5
Page 305
Cat. No.
8268870000
Type
AP DK5
Digital signal
processing
Ordering data
For TS 32
For TS 35
With combi foot TS 32/TS 35
Technical data
Input:
Supply voltage
Supply current
Control voltage
Control input curren
Min. pulse duration of input voltage
Output:
Output voltage
Max. output current
Internal voltage drop
Range of switch-off delay
Cat. No.
8268870000
Page 305
153
Timers
Turn off delay module MCZ TO
MCZ TO 24 Vdc turn-off delay 50 ms
MCZ TO 24 Vdc turn-off delay 150 ms
Ordering data
For TS 35
Type
MCZ TO 24 Vdc turn-off delay 50 ms
Type
MCZ TO 24 Vdc turn-off delay 150 ms
Technical data
Input
Input voltage
Min. pulse duration
Power consupmtion
Input power
Power consumption when pulse applied
24 Vdc ± 10 %
2 ms
6.7 mA ± 10 %
160 mW
200 mA
Output
Output voltage
Max. output current
Max. voltage drop at max. load
Impulse loading/limiting overload current
Reverse current at 48 V (static current)
Switch-off delay
Switching frequency dc
5…48 Vdc
20 mA
≤ 1.6 V
200 mA
max. 0,16 mA
50 ms
20 Hz
Insulation coordination/safe disconnection to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof, input/output mounting rail
300 V
6 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
300 V
6 kV
III
2
≥ 5.5 mm
4 kVeff / 1 min
Opto coupler
to VDE 0884
to VDE 0884
Ambient temperature
Storage temperature
Conductor
Conductor cross-section
Approvals
Total width
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
1.5 mm2
CE, UL, CSA
6 mm
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
1.5 mm2
CE, UL, CSA
6 mm
tv = var
The timer module can be used for extending
short pulses and fixed times. Provides PLC versions with switch off delay.
Schematic circuit diagram
154
Cat. No.
8324590000
24 Vdc ± 10 %
2.5 ms
6.7 mA ± 10 %
160 mW
200 mA
5…48 Vdc
20 mA
≤ 1.6 V
200 mA
max. 0,16 mA
150 ms
5 Hz
Cat. No.
8286410000
155
Digital signal
processing