9912800005

9912800005

  • 厂商:

    WEIDMULLER(魏德米勒)

  • 封装:

    -

  • 描述:

    CB2212-108ANCAUX

  • 数据手册
  • 价格&库存
9912800005 数据手册
VAL-SQ SI… 25 and 40 kA Surge Protective Device for small installation protection TRABTECH Data Sheet 2532_en_A 1 © PHOENIX CONTACT - 07/2008 Description 2 The VAL-SQ SI… Surge Protective Device (SPD) provides surge protection in a compact, affordable package. – – A high-energy suppression circuit provides 25 or 40 kA (depending upon the model) of surge current rating per phase. Each surge suppression mode in the VAL-SQ SI… is individually fused. – – The VAL-SQ SI… SPD uses a sealed, NEMA 4X housing, allowing installation in harsh environments with limited space. Operating status lights are easily observed and provide verification of protection. – Features Compact design for flexible mounting locations 25 or 40 kA surge current capacity per phase (L-N and N-G) protects against high-energy lightning strikes and transient voltages NEMA Type 4X enclosure LEDs provide continuous feedback on the status of each phase UL/cUL listed; meets UL 1449 2nd edition February 2007 requirements DANGER: Risk of electric shock. Disconnect power before installing or servicing. Service to be performed by qualified personnel only. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for all products listed on the following page: VAL-SQ SI… 3 Ordering Data Products Description Type Part No. Pcs./Pkt. Surge protective device, 25 kA, 2-phase, 2-wire + ground for 120 V (L-N) applications with common GND-N VAL-SQ SI 25-2C-120 2800003 1 Surge protective device, 40 kA, 2-phase, 2-wire + ground + neutral for 120 V (L-N) applications with separate GND and N VAL-SQ SI 40-2S-120 2800005 1 Surge protective device, 40 kA, 2-phase, 2-wire + ground + neutral for 240 V (L-N) applications with separate GND and N VAL-SQ SI 40-2S-240 2800006 1 Surge protective device, 40 kA, 3-phase, 3-wire + ground for up to 600 V (L-N) applications with common GND-N VAL-SQ SI 40-3C-600 2800007 1 2800007 4 Technical Data Surge Protection Data 2800003 2800005 2800006 Maximum surge current per phase 25 kA 40 kA 40 kA 40 kA Short circuit current rating (SCCR) 22 kA 25 kA 10kA 200 kA Nominal voltage 120 V 120 V 240 V 600 V1 Type 1 + 2 (Surge arrestor & TVSS) Type 2 (TVSS) Circuit type MOV technology UL Class 1 Type 2 (TVSS) Type 1 + 2 (Surge arrestor & TVSS) Up to 600 V Surge Voltage Rating (SVR) L-N N-G L-L Part No. Type 2800003 VAL-SQ SI 25-2C-120 MCOV 150 500 – 900 2800005 VAL-SQ SI 40-2S-120 150 500 800 – 2800006 VAL-SQ SI 40-2S-240 320 900 900 – 2800007 VAL-SQ SI 40-3C-600 650 1800 2000 – General Data 2800003 2800005 2800006 2800007 Dimensions (WxHxD) 2.24 x 2.08 x 2.25 in. (56.9 x 52.8 x 56.9 mm) 3.00 x 2.73 x 3.60 in. (76.2 x 69.3 x 91.4 mm) 3.00 x 2.73 x 3.60 in. (76.2 x 69.3 x 91.4 mm) 3.60 x 2.73 x 3.00 in. (91.4 x 69.3 x 76.2 mm) 1.0 lb. (0.45 kg) Weight 0.53 lb. (0.24 kg) 1.2 lb. (0.54 kg) 1.2 lb. (0.54 kg) Enclosure material Non-metallic Non-metallic Non-metallic Non-metallic Housing rating NEMA 4X NEMA 4X NEMA 4X NEMA 4X Phase connection Parallel #14 AWG Parallel #10 AWG Parallel #10 AWG Parallel #12 AWG Conduit connector 1/2-in. NPT Operating frequency 50/60 Hz Operating temperature -40 to 70°C (-40 to 160°F) Operating altitude 0 to 12,000 ft. (3,658 m) Approvals UL/cUL 1449 2nd edition, February 2007 requirements 1283 CSA C22.2 No. 8-M1986 IEEE C62.41.1-2002 C62.41.2-2002 C62.45-2002 2532_en_A PHOENIX CONTACT 2 VAL-SQ SI… Dimensions 2800005 & 2800006 3.00 in. 76.2 mm 3.60 in. 91.4 mm 2.73 in. 69.3 mm 0.65 in. 16.5 mm 2.24 in. 56.9 mm 2.08 in. 52.8 mm 0.65 in. 16.5 mm 2532_en_A 3.00 in. 76.2 mm 3.60 in. 91.4 mm 2.24 in. 56.9 mm Figure 1 2800007 2.73 in. 69.3 mm 2800003 0.65 in. 16.5 mm 5 Dimensions PHOENIX CONTACT 3 VAL-SQ SI… 6 Installation DANGER: Turn off all power supplying this equipment before working on or inside equipment. 2 Always follow federal and local regulations during installation. Apply appropriate personal protective equipment (PPE) and follow electrical work practices. 1 Only qualified electrical personnel may install and service this equipment. 3 Never open SPD. No serviceable parts are inside. WARNING: This equipment depends upon an effective ground. Failure to obtain a quality ground connection may result in explosion or arc flash. NOTE: Megger® or hi-potential tests will damage this surge protective device. Turn off all power supplying the equipment and isolate the surge protective device before testing. 1 2 Figure 2 4. 6.1 1. Mounting and connection Position the VAL-SQ SI… so the LEDs are visible and the wires are as short and straight as possible. The SPD can be mounted in any orientation. It attaches through any side of the enclosure being protected using 1/2-NPT threaded nipple. SPD Protected device 3 Strain relief nut Mounting the SPD Connect the VAL-SQ SI… to the appropriate phases and ground lines as shown on the following illustrations. Wires are color coded as shown. If equipped with a green wire, it must be connected to ground. VAL-SQ SI Series NOTE: Surge Protective Device TRABTECH Cover or remove components inside any enclosure before drilling to prevent shavings from causing short-circuits across terminals and races. 2. 3. www.phoenixcontact.com 1 2 121 Create a hole in the enclosure, 2, for 1/2-in. conduit attachment, approximately 7/8 in. (22 mm) diameter. Route the wires and nipple through the hole and secure the VAL-SQ SI… to the enclosure with the strain relief nut, 3. Black White C N A Figure 3 2532_en_A Single-phase, 3-wire, 120/240 V AC VAL-SQ SI 25-2C-120 connection PHOENIX CONTACT 4 VAL-SQ SI… VAL-SQ SI Series VAL-SQ SI Series Surge Protective Device TRABTECH 1 2 Black White www.phoenixcontact.com 12 1 Surge Protective Device TRABTECH www.phoenixcontact.com 12 1 1 4 5 1 4 55 Green/yellow Blue Brown A C A N N C B Figure 4 Figure 6 1- or 2-phase, 240 V AC VAL-SQ SI 40-2S-240 connection 3-phase Wye, 208 V AC VAL-SQ SI 25-2C-120 connection VAL-SQ SI Series Surge Protective Device TRABTECH 1 2 3 1 2 33 www.phoenixcontact.com 2 111 1 2 Green White Black Black White A C A N N C Figure 5 2532_en_A 1- or 2-phase, 120 V AC VAL-SQ SI 40-2S-120 connection B Figure 7 3-phase Wye, 208, 480 or 600 V AC VAL-SQ SI 40-3C-600 connection PHOENIX CONTACT 5 VAL-SQ SI… All wires must be attached to the appropriate wires; phase, neutral or ground. The SPD must be connected to power through a circuit breaker rated appropriately for the connected wire gauge. Use an appropriate breaker, i.e., 2- or 3-pole, for the electrical configuration. VAL-SQ SI Series 1 2 Surge Protective Device TRABTECH www.phoenixcontact.com Black White All wires must be connected for the SPD to function correctly. 2 1 11 The wires between the SPD and protected device should be twisted 1/2 turn every 12 in. (300 mm). Do not loop or coil wire. Excess wire must be removed without applying stress to wires. N A C 7 B Figure 8 3-phase High-Leg Delta, 120/240 V AC VAL-SQ SI 40-3C-600 connection Operation LEDs indicate the operating status of the individual phases of the VAL-SQ SI… The LEDs illuminate when the relevant phase is operating correctly. Device Phase Phase LED LEDs LEDs VAL-SQ SI Series VAL-SQ SI Series VAL-SQ SI Series Surge Protective Device Surge Protective Device Surge Protective Device VAL-SQ SI Series TRABTECH www.phoenixcontact.com TRABTECH www.phoenixcontact.com TRABTECH Surge Protective Device TRABTECH www.phoenixcontact.com www.phoenixcontact.com Figure 10 2 1 11 1 2 Black White A LED location If a phase is not operating correctly or a fault occurs, the corresponding LED is not lit. When a phase LED is not lit, verify the correct voltage is present on each phase. If power is present, the VAL-SQ SI… must be replaced. There are no serviceable parts. C B Figure 9 3-phase, Delta, 240, 480, 600 V AC, VAL-SQ SI 40-3C-600 connection Type 1 (Lightning Arrestor) SPDs can be connected on either side of the service entrance. Type 2 (TVSS) SPDs must be connected on the load side of the service entrance breakers as shown. Disconnects to the SPD are recommended. 2532_en_A PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com 6
9912800005 价格&库存

很抱歉,暂时无法提供与“9912800005”相匹配的价格&库存,您可以联系我们找货

免费人工找货