9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – A C Ve r s i o n
Circuit Breakers
Hydraulic Magnetic Type
9926 Series
Double Pole
Single pole and double pole versions
120/240 VAC, 50/60 Hz
Up to 25A
Just 13 mm wide
Mounts on 35mm DIN-rail
UL 489 listed, CSA C22.2 No. 5-02, CE
VDE
Ordering Data
Technical Data
Voltage
Current
Type: Single Pole
Current Ratings
(amps)
Part No.
TS 35
0.5
1
Description
Part No.
TS 35
Description
9926251000
9926251001
QL-1-13-DM-KM-0.5
QL-1-13-DM-KM-01
0.5
1
9926252000
9926252001
QL-2-13-DM-KM-0.5
QL-2-13-DM-KM-01
2
9926251002
QL-1-13-DM-KM-02
2
9926252002
QL-2-13-DM-KM-02
3
4
9926251003
9926251004
QL-1-13-DM-KM-03
QL-1-13-DM-KM-04
3
4
9926252003
9926252004
QL-2-13-DM-KM-03
QL-2-13-DM-KM-04
5
6
7
9926251005
9926251006
9926251007
QL-1-13-DM-KM-05
QL-1-13-DM-KM-06
QL-1-13-DM-KM-07
5
6
7
9926252005
9926252006
9926252007
QL-2-13-DM-KM-05
QL-2-13-DM-KM-06
QL-2-13-DM-KM-07
8
10
13
15
16
9926251008
9926251010
9926251013
9926251015
9926251016
QL-1-13-DM-KM-08
QL-1-13-DM-KM-10
QL-1-13-DM-KM-13
QL-1-13-DM-KM-15
QL-1-13-DM-KM-16
8
10
13
15
16
9926252008
9926252010
9926252013
9926252015
9926252016
QL-2-13-DM-KM-08
QL-2-13-DM-KM-10
QL-2-13-DM-KM-13
QL-2-13-DM-KM-15
QL-2-13-DM-KM-16
20
25
9926251020
9926251025
QL-1-13-DM-KM-20
QL-1-13-DM-KM-25
20
25
9926252020
9926252025
QL-2-13-DM-KM-20
QL-2-13-DM-KM-25
9926 Series AC Version - dimensions in mm (in.)
120/240 VAC, 50/60Hz
0.5A
25A
66
(2.6)
-40…+65°C
14AWG min., 10AWG max.
10AWG min.
Although the 9926 series uses a magnetic only trip mechanism, CSA
testing indicates a trip characteristic similar to thermal magnetic trip
mechanisms. No de-rating is required at elevated temperatures.
Additional trip curves and amp ratings are available
upon request.
Tripping Time
10
Seconds
1
0.1
Minutes
0.001
0.001
(%) Rated Current
4000
5000
0.4
1
0.01
4000
5000
0.6
Ambient Temperature 30°C
10
0.01
2000
2500
3000
1.5
0.1
1500
4
1
1000
28
10
400
500
125% 150% 200% 400% 600% 800% 1000%
minimum 15
8
4
0.7
0.09 0.007 0.005
(sec)
10
100
105
130
150
200
Sample trip characteristics - KM
Tripping Time
Trip Curves—Hydraulic Magnetic Type
Typical time/current characteristics at 30ºC
100
Ambient Temperature 30°C
1
Seconds
The 9926 circuit breakers do not have provisions for marking tags.
A possible solution is to cut the adhesive SchS2 tag rail to length
(approximately 20 mm on a single pole unit so the current rating
remains visible or approximately 30 mm on a two pole unit).
The SchS2 accepts DEK, WS and ESG 8/17 marking tags.
The part number for adhesive SchS2 is 1720600000.
Operating Characteristics
Curve KM
Operating Characteristics
Curve 1
100
*Wire sizes: gauges specified are the minimum allowable as per CSA
and UL standards.
9926 Series–AC version Trip Curve
1000
1000
2000
2500
3000
9926 Series–AC version Trip Curve
1500
67101960
67101961
67101913
64.8
(2.55)
1000
Power lug, straight
Power lug, 90°
Lock-out handle
45
(1.77)
400
500
67101974
5
(0.2)
300
Bus-bar end cap, 2 pole
13
(0.51)
32
(1.26)
Minutes
Part No.
67101904
67101972
67101973
19
(0.75)
20 in.-lb
100
105
125
150
200
Torque
Approval
UL 489 listed, CSA C22.2 No. 5-02, CE, VDE
Accessories
Bus-bar (1 pole, insulated, 1 m)
Bus-bar (2 pole, insulated, 1 m)
Bus-bar end cap, 1 pole
90
26
(1.02)
92.8
(3.65)
10000 mechanical operations
Operating temperature
Wire size*
0.5-15A:
20-25A:
57
(2.24)
Operating life
13
(0.51)
28.5
(1.12)
10,000A
1500V, 50/60Hz
100MM
71.4
(2.81)
Interrupting capacity
Dielectric strength
Insulation resistance
17.9
(0.7)
74
(2.91)
minimum
maximum
maximum 300
(sec)
Type: Double Pole
Current Ratings
(amps)
300
•
•
•
•
•
•
•
9926 Series
Single Pole
(%) Rated Current
Trip Curve 1 applies to the following part numbers where
"XX" is the current rating:
Single Pole— 99262512XX
Double Pole— 99262522XX
3
9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – A C Ve r s i o n w i t h C o n t a c t s
Circuit Breakers with
Auxiliary switch, Trip alarm,
Combination of both
9926 Series
Single Pole
w/ Auxiliary Contact
9926 Series
Single Pole Trip
(Alarm Contact)
9926 Series
Single Pole Combination
(Auxiliary & Alarm Contact)
• AC voltages (120/240V)
• Single and double pole versions
• UL 489 and CSA listed
• Factory fitted auxiliary or trip alarm
• Compact 6.5mm width
• Attached to right hand side of
circuit breaker
Technical Data
Type: Single Pole Aux
Voltage
120/240 VAC, 50/60Hz
Current
minimum
Current
Ratings
(amps) Part No.
1 9926261001
2 9926261002
5 9926261005
10 9926261010
15 9926261015
20 9926261020
25 9926261025
0.5A
maximum
Interrupting capacity
25A
10,000A
Dielectric strength
Insulation resistance
Operating life
1500V, 50/60Hz
100MM
10000
mechanical operations
Operating temperature
-40…+65°C
Wire size*
0.5-15A:
20-25A:
Torque
14AWG min., 10AWG max.
10AWG min.
20 in.-lb
Description
QL-A-1-13-DM-KM-1
QL-A-1-13-DM-KM-2
QL-A-1-13-DM-KM-5
QL-A-1-13-DM-KM-10
QL-A-1-13-DM-KM-15
QL-A-1-13-DM-KM-20
QL-A-1-13-DM-KM-25
Current
Ratings
(amps) Part No.
1
9926281001
2
9926281002
5
9926281005
10 9926281010
15 9926281015
20 9926281020
25 9926281025
Description
QL-T-1-13-DM-KM-1
QL-T-1-13-DM-KM-2
QL-T-1-13-DM-KM-5
QL-T-1-13-DM-KM-10
QL-T-1-13-DM-KM-15
QL-T-1-13-DM-KM-20
QL-T-1-13-DM-KM-25
9926 Series
Double Pole Trip
(Alarm Contact)
9926 Series
Double Pole
w/ Auxiliary Contact
Approval
UL 489 listed, CSA C22.2 No. 5-02, CE, VDE
Type: Single Pole Combo
Type: Single Pole Trip
Current
Ratings
(amps) Part No.
1
9926271001
2
9926271002
5
9926271005
10 9926271010
15 9926271015
20 9926271020
25 9926271025
Description
QL-AT-1-13-DM-KM-1
QL-AT-1-13-DM-KM-2
QL-AT-1-13-DM-KM-5
QL-AT-1-13-DM-KM-10
QL-AT-1-13-DM-KM-15
QL-AT-1-13-DM-KM-20
QL-AT-1-13-DM-KM-25
9926 Series
Double Pole Combination
(Auxiliary & Alarm Contact)
*Wire sizes: gauges specified are the minimum
allowable as per CSA and UL standards.
The 9926 circuit breakers do not have provisions for
marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a
single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit). The SchS2
accepts DEK, WS and ESG 8/17 marking tags. The
part number for adhesive SchS2 is 1720600000.
Type: Double Pole Aux
Current
Ratings
(amps) Part No.
1
9926262001
2
9926262002
5
9926262005
10 9926262010
15 9926262015
20 9926262020
25 9926262025
Type: Double Pole Trip
Description
QL-A-2-13-DM-KM-1
QL-A-2-13-DM-KM-2
QL-A-2-13-DM-KM-5
QL-A-2-13-DM-KM-10
QL-A-2-13-DM-KM-15
QL-A-2-13-DM-KM-20
QL-A-2-13-DM-KM-25
1000
Operating Characteristics
Curve KM
9926272005 QL-T-2-13-DM-KM-5
9926272010 QL-T-2-13-DM-KM-10
9926272015 QL-T-2-13-DM-KM-15
9926272020 QL-T-2-13-DM-KM-20
9926272025 QL-T-2-13-DM-KM-25
31.3
(1.23)
26.2
(1.03)
(N/O)16
(N/C)18
(C)15
Ambient Temperature 30°C
TRIP ALARM Q. CONNECTORS
21.1
(0.83)
10
5.5
(0.22)
0.5
(0.02)
Tripping Time
Minutes
100
57.0
(2.24)
1
10
14(N/O)
21.3
(0.84)
(%) Rated Current
4000
5000
2000
2500
3000
1500
1000
400
500
300
0.001
32.9
(1.3)
10.7
(0.42)
0.5
(0.02)
0.1
100
105
125
150
200
7
(0.28)
2.8
(0.11)
11(C)
Seconds
12(N/C)
AUX SWITCH Q. CONNECTORS
1
0.01
4
Part No.
Description
9926272001 QL-T-2-13-DM-KM-1
9926272002 QL-T-2-13-DM-KM-2
Dual Mount Dimensions in mm (in.)
Trip Curves—Hydraulic
Magnetic Type Typical
time/current characteristics
at 30ºC
Additional trip curves and
amp ratings are available
upon request.
Type: Double Pole Combo
Current
Ratings
(amps) Part No.
1
9926282001
2
9926282002
5
9926282005
10 9926282010
15 9926282015
20 9926282020
25 9926282025
2
(0.08)
9926 Series–AC version Trip Curve
Current
Ratings
(amps)
1
2
5
10
15
20
25
Description
QL-AT-2-13-DM-KM-1
QL-AT-2-13-DM-KM-2
QL-AT-2-13-DM-KM-5
QL-AT-2-13-DM-KM-10
QL-AT-2-13-DM-KM-15
QL-AT-2-13-DM-KM-20
QL-AT-2-13-DM-KM-25
9 9 2 6 S e r i e s B r a n c h R a t e d C i rc u i t B re a k e r s – D C Ve r s i o n
Circuit Breakers
Hydraulic Magnetic Type
9926 Series
Single Pole
(80 VDC)
9926 Series
Single Pole
(125 VDC)
• Single pole versions only
• U2 trip curve for general purpose
applications
• 80 and 125 VDC
• Up to 60A
• Just 13 mm wide
• Mounts on 35mm DIN-rail
• UL 489A listed
• VDE
Type: Single Pole (80 VDC)
Current
Ratings
(amps)
0.5
1
2
3
4
5
10
15
20
25
30
35
40
45
50
60
Accessories
Part No.
9926251900
Description
QY-1-13-DM-U2-0.5
9926251901
9926251902
QY-1-13-DM-U2-01
QY-1-13-DM-U2-02
9926251903
9926251904
QY-1-13-DM-U2-03
QY-1-13-DM-U2-04
9926251905
9926251910
9926251915
QY-1-13-DM-U2-05
QY-1-13-DM-U2-10
QY-1-13-DM-U2-15
9926251920
9926251925
9926251930
9926251935
9926251940
QY-1-13-DM-U2-20
QY-1-13-DM-U2-25
QY-1-13-DM-U2-30
QY-1-13-DM-U2-35
QY-1-13-DM-U2-40
9926251945
9926251950
QY-1-13-DM-U2-45
QY-1-13-DM-U2-50
9926251960
QY-1-13-DM-U2-60
9926 Series–DC version Trip Curve
9926251840
QY-1-13-DM-U2-40-B1
9926251845
9926251850
9926251860
QY-1-13-DM-U2-45-B1
QY-1-13-DM-U2-50-B1
QY-1-13-DM-U2-60-B1
74
(2.91)
66
(2.6)
13
(0.51)
92.8
(3.65)
Minutes
Ambient Temperature 30°C
10
1
19
(0.75)
1
32
(1.26)
0.1
5
(0.2)
45
(1.77)
64.8
(2.55)
0.01
300
0.001
100
105
130
150
200
Approval
UL 489A Listed, CE, VDE
Tripping Time
100 MM
10000
mechanical operations
Operating temperature
-40…+65°C
Wire size*
1-15A:
14 AWG min.,
10 AWG max.
20-25A:
10 AWG min.
Torque
20 in.-lb
QY-1-13-DM-U2-15-B1
QY-1-13-DM-U2-20-B1
QY-1-13-DM-U2-25-B1
QY-1-13-DM-U2-30-B1
QY-1-13-DM-U2-35-B1
10
Seconds
Insulation resistance
Operating life
9926251815
9926251820
9926251825
9926251830
9926251835
Dimensions in mm (in.)
Operating Characteristics
Curve U2 DC
(4% Ripple Factor)
100
80,125 VDC
0.5 A
60 A
10,000 A
1500 V, 50/60 Hz
QY-1-13-DM-U2-05-B1
QY-1-13-DM-U2-10-B1
Additional trip curves and amp ratings
are available upon request.
1000
minimum
maximum
Interrupting capacity
Dielectric strength
9926251805
9926251810
57
(2.24)
67101913
QY-1-13-DM-U2-02-B1
QY-1-13-DM-U2-03-B1
QY-1-13-DM-U2-04-B1
28.5
(1.12)
Lock-out handle
9926251802
9926251803
9926251804
71.4
(2.81)
67101961
Description
QY-1-13-DM-U2-01-B1
4000
5000
Power lug, 90°
2000
2500
3000
67101973
67101960
1500
Bus bar end cap, 1 pole
Power lug, straight
1000
Part No.
67101904
Part No.
9926251801
Trip Curves—Hydraulic
Magnetic Type Typical
time/current characteristics
at 30ºC
400
500
Type
Bus-bar (1 pole, insulated 1m)
Technical Data
Voltage
Current
Type: Single Pole (125 VDC)
Current
Ratings
(amps)
1
2
3
4
5
10
15
20
25
30
35
40
45
50
60
17.9
(0.7)
Ordering Data
(%) Rated Current
*Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards.
The 9926 circuit breakers do not have provisions for
marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a
single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit). The SchS2
accepts DEK, WS and ESG 8/17 marking tags. The
part number for adhesive SchS2 is 1720600000.
5
9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s
Circuit Breakers
Hydraulic Magnetic Type
9926 Series
Single Pole
9926 Series
Double Pole
9926 Series
Triple Pole
• AC Voltages 240/480V
• Trip curve 2 for general purpose
applications
• UL 1077 recognized
• VDE, CSA, and CE Approved
• Just 13 mm wide
• Mounts to 35 mm DIN-rail
• Factory fitted auxiliary or trip alarm
• Single, double and triple pole versions
Ordering Data
Type: Single Pole
Current
Ratings
(amps)
1
2
3
4
5
6
8
10
15
20
25
35
40
50
60
Accessories
Part No.
Description
9926251501
QZ-1-13-D-2-01
9926251502
9926251503
QZ-1-13-D-2-02
QZ-1-13-D-2-03
9926251504
9926251505
QZ-1-13-D-2-04
QZ-1-13-D-2-05
9926251506
9926251508
QZ-1-13-D-2-06
QZ-1-13-D-2-08
9926251510
9926251515
9926251520
QZ-1-13-D-2-10
QZ-1-13-D-2-15
QZ-1-13-D-2-20
9926251525
9926251535
9926251540
QZ-1-13-D-2-25
QZ-1-13-D-2-35
QZ-1-13-D-2-40
9926251550
9926251560
QZ-1-13-D-2-50
QZ-1-13-D-2-60
Part No.
Description
9926252501
QZ-2-13-D-2-01
9926252502
9926252504
QZ-2-13-D-2-02
QZ-2-13-D-2-04
9926252505
9926252506
QZ-2-13-D-2-05
QZ-2-13-D-2-06
9926252510
9926252515
QZ-2-13-D-2-10
QZ-2-13-D-2-15
9926252520
9926252525
9926252530
QZ-2-13-D-2-20
QZ-2-13-D-2-25
QZ-2-13-D-2-30
9926252535
9926252540
9926252550
QZ-2-13-D-2-35
QZ-2-13-D-2-40
QZ-2-13-D-2-50
9926252560
QZ-2-13-D-2-60
Part No.
Description
9926253510
QZ-3-13-D-2-10
9926253515
9926253520
QZ-3-13-D-2-15
QZ-3-13-D-2-20
9926253525
9926253530
QZ-3-13-D-2-25
QZ-3-13-D-2-30
9926253540
9926253550
QZ-3-13-D-2-40
QZ-3-13-D-2-50
9926253560
QZ-3-13-D-2-60
65
(2.56)
13
(0.51)
60
(2.36)
26
(1.02)
39
(1.54)
92.8
(3.65)
25.9
(0.94)
45
(1.77)
13
(0.51)
63.8
(2.51)
73
(2.87)
Operating Characteristics
Curve 2
Minutes
100
Ambient Temperature 30°C
10
1
10
1
0.1
0.01
(%) Rated Current
4000
5000
2000
2500
3000
1500
1000
0.001
400
500
The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit).The SchS2 accepts DEK, WS and ESG 8/17 marking tags.
The part number for adhesive SchS2 is 1720600000.
Additional trip curves and
amp ratings are available
upon request.
1000
300
*Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards.
9926 Series–Supplemental Trip Curve
Trip Curves—Hydraulic
Magnetic Type Typical
time/current characteristics
at 30ºC
100
105
130
150
200
Technical Data
Voltage
277/480 VAC @ 50/60 Hz
Current
minimum
0.5 A
maximum
60 A
Interrupting capacity
5 kA @ 277/480 V, 5 kA @ 120 V, 5 kA @ 240 V
Dielectric strength
1500 V, 50/60 Hz
Insulation resistance
100 MM
Operating life
10000 mechanical operations
Operating temperature
-40…+65°C
Wire size*
1-15A:
14 AWG min., 10 AWG max.
20-25A:
10 AWG min.
Torque
20 in.-lb
Approval
UL 1077 Recognized, VDE (EN 60947-2), CSA C22.2 No. 235, CE Approved
Tripping Time
5.0
(0.2)
13
(0.51)
Seconds
Part No.
67101904
67101972
67101971
67101973
67101974
67101960
67101961
67101913
44
(1.73)
6
Type: Triple Pole
Current
Rating
(amps)
10
15
20
25
30
40
50
60
9926 Series Supplemental – dimensions in mm (in.)
22.5
(0.86)
Type
Bus bar (1 pole, insulated 1m)
Bus bar (2 pole, insulated 1m)
Bus bar (3 pole, insulated 1m)
Bus bar end cap, 1 pole
Bus bar end cap, 2 pole or 3 pole
Power lug, straight
Power lug, 90°
Lock-out handle
Type: Double Pole
Current
Rating
(amps)
1
2
4
5
6
10
15
20
25
30
35
40
50
60
9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s w i t h C o n t a c t s
Circuit Breakers
Auxiliary switch, Trip alarm,
Combination of both
9926 Series
Single Pole
w/ Auxiliary Contact
9926 Series
Single Pole Trip
(Alarm Contact)
9926 Series
Single Pole Combination
(Auxiliary & Alarm Contact)
• AC Voltages 240/480V
• Trip curve 2 for general purpose
applications
• UL 1077 recognized
• VDE, CSA, and CE Approved
• Just 13 mm wide
• Mounts to 35 mm DIN-rail
• Factory fitted auxiliary or trip alarm
• Single, double and triple pole versions
Type: Single Pole Aux
Technical Data
Voltage
277/480 VAC @ 50/60 Hz
Current
minimum
0.5 A
maximum
60 A
Interrupting capacity
5 kA @ 277/480 V,
5 kA @ 120 V, 5 kA @ 240 V
Dielectric strength
Insulation resistance
Operating life
1500 V, 50/60 Hz
100 MM
10000
mechanical operations
Operating temperature
Wire size*
1-15A:
20-25A:
Torque
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926261501
9926261502
Description
QZ-A-1-13-D-2-01
QZ-A-1-13-D-2-02
9926261505
QZ-A-1-13-D-2-05
9926261510
QZ-A-1-13-D-2-10
9926261515
9926261520
QZ-A-1-13-D-2-15
QZ-A-1-13-D-2-20
9926261525
QZ-A-1-13-D-2-25
Type: Single Pole Trip
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926271501
9926271502
Description
QZ-T-1-13-D-2-01
QZ-T-1-13-D-2-02
9926271505
QZ-T-1-13-D-2-05
9926271510
QZ-T-1-13-D-2-10
9926271515
9926271520
QZ-T-1-13-D-2-15
QZ-T-1-13-D-2-20
9926271525
QZ-T-1-13-D-2-25
Type: Single Pole Combo
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926281501
9926281502
Description
QZ-AT-1-13-D-2-01
QZ-AT-1-13-D-2-02
9926281505
QZ-AT-1-13-D-2-05
9926281510
QZ-AT-1-13-D-2-10
9926281515
9926281520
QZ-AT-1-13-D-2-15
QZ-AT-1-13-D-2-20
9926281525
QZ-AT-1-13-D-2-25
-40…+65°C
14 AWG min., 10 AWG max.
10 AWG min.
20 in.-lb
Approval
UL 1077 Recognized, VDE (EN 60947-2),
CSA C22.2 No. 235, CE Approved
9926 Series
Double Pole
w/ Auxiliary Contact
9926 Series
Double Pole Combination
(Auxiliary & Alarm Contact)
9926 Series
Double Pole Trip
(Alarm Contact)
*Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards.
The 9926 circuit breakers do not have provisions for
marking tags. A possible solution is to cut the adhesive
SchS2 tag rail to length (approximately 20 mm on a
single pole unit so the current rating remains visible or
approximately 30 mm on a two pole unit). The SchS2
accepts DEK, WS and ESG 8/17 marking tags.The
part number for adhesive SchS2 is 1720600000.
9926 Series–Supplemental Trip Curve
Trip Curves—Hydraulic
Magnetic Type Typical
time/current characteristics
at 30ºC
1000
Operating Characteristics
Curve 2
Type: Double Pole Aux
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926262501
9926262502
9926262505
Description
QZ-A-2-13-D-2-01
QZ-A-2-13-D-2-02
QZ-A-2-13-D-2-05
9926262510
9926262515
9926262520
QZ-A-2-13-D-2-10
QZ-A-2-13-D-2-15
QZ-A-2-13-D-2-20
9926262525
QZ-A-2-13-D-2-25
Type: Double Pole Trip
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926272501
9926272502
9926272505
Description
QZ-T-2-13-D-2-01
QZ-T-2-13-D-2-02
QZ-T-2-13-D-2-05
9926272510
9926272515
9926272520
QZ-T-2-13-D-2-10
QZ-T-2-13-D-2-15
QZ-T-2-13-D-2-20
9926272525
QZ-T-2-13-D-2-25
Type: Double Pole Combo
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926282501
9926282502
9926282505
Description
QZ-AT-2-13-D-2-01
QZ-AT-2-13-D-2-02
QZ-AT-2-13-D-2-05
9926282510
9926282515
9926282520
QZ-AT-2-13-D-2-10
QZ-AT-2-13-D-2-15
QZ-AT-2-13-D-2-20
9926282525
QZ-AT-2-13-D-2-25
Tripping Time
Minutes
100
Ambient Temperature 30°C
10
9926 Series
Triple Pole
w/ Auxiliary Contact
1
10
9926 Series
Triple Pole Trip
( Alarm Contact)
9926 Series
Triple Pole Combination
(Auxiliary & Alarm Contact)
Seconds
1
0.1
0.01
4000
5000
2000
2500
3000
1500
1000
400
500
300
100
105
130
150
200
0.001
Type: Triple Pole Aux
(%) Rated Current
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926263501
9926263502
9926263505
Description
QZ-A-3-13-D-2-01
QZ-A-3-13-D-2-02
QZ-A-3-13-D-2-05
9926263510
9926263515
9926263520
QZ-A-3-13-D-2-10
QZ-A-3-13-D-2-15
QZ-A-3-13-D-2-20
9926263525
QZ-A-3-13-D-2-25
Type: Triple Pole Trip
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926273501
9926273502
9926273505
Description
QZ-T-3-13-D-2-01
QZ-T-3-13-D-2-02
QZ-T-3-13-D-2-05
9926273510
9926273515
9926273520
QZ-T-3-13-D-2-10
QZ-T-3-13-D-2-15
QZ-T-3-13-D-2-20
9926273525
QZ-T-3-13-D-2-25
Type: Triple Pole Combo
Current
Ratings
(amps)
1
2
5
10
15
20
25
Part No.
9926283501
9926283502
9926283505
Description
QZ-AT-3-13-D-2-01
QZ-AT-3-13-D-2-02
QZ-AT-3-13-D-2-05
9926283510
9926283515
9926283520
QZ-AT-3-13-D-2-10
QZ-AT-3-13-D-2-15
QZ-AT-3-13-D-2-20
9926283525
QZ-AT-3-13-D-2-25
7
9 9 2 6 S e r i e s S u p p l e m e n t a l C i rc u i t B re a k e r s – G F C I
Ground Fault Current Interrupt
Ordering Data
230 (CE) / 240 (UL)
5 kA
–
0.26
1000
2
-40 to +65ºC
-
CB
CB
CB
CB
W/GFI
W/GFI
W/GFI
W/GFI
QF17A2550 - CB W/GFI
Operating Characteristics
Curve 2
100
44
(1.73)
Ambient Temperature 30°C
10
68.8
(2.71)
1
10
26
(1.02)
1
Seconds
Approval
UL 1077 and UL 1053, CE
QF17A2515
QF17A2520
QF17A2525
QF17A2530
Trip Curves—Hydraulic Magnetic
Type Typical
time/current characteristics
at 30ºC
Minutes
Trip Curve (standard)
Operating Temperature
73
(2.87)
65
(2.56)
QF17A2510 - CB W/GFI
0.1
7.8
(0.307)
30 (CE) / 22 (UL)
1+N
Earth Leakage/GFCS
Rated Voltage (V)
Rated Interrupting/
Withstand Capacity (kA)
Weight (kg)
Description
QF17A2505 - CB W/GFI
9926 Series–AC version Trip Curve
5 to 50A
Tripping Time
Technical Data
Standard Ampere Ratings (A)
Sensitivity (mA)
Number of Poles
Equipment Type
9926 Series GFCI – dimensions in mm (in.)
Type: Single Pole GFCI
Current
Ratings
(amps) Part No.
5
9926291105
10
9926291110
15
9926291115
20
9926291120
25
9926291125
30
9926291130
50
9926291150
4000
5000
2000
2500
3000
1500
1000
400
500
300
100
105
130
150
200
0.001
16.4
(0.646)
8.0
(0.315)
71.4
(2.81)
0.01
26
(1.02)
•
(2.24)
•
•
57
•
CE approved
UL1077 and UL1053 recognized
Small frame size (26mm wide)
Single pole plus switched neutral
earth leakage protection
Trip point is unaffected by ambient
temperature
Current ratings up to 50A
Trip indication
(mid trip handle position)
Trip curve 2 for general purpose
applications
93
(3.66)
82.4
(3.24)
•
•
•
•
9926 Series
GFCI
(%) Rated Current
35.7
(1.406)
8
9926 Series Mounting Options and Accessories
Mounting Options
93%
95
ON
OFF
95
OF
F
ON
OF
F
ON
5 N VERT 45
W
ON
OFF
100%
ON
VERT D 4
O
R
5 N HO IZ DO 4
W
10
ON
OF F
ON
OF
F
%
ON
OF
F
5%
100%
HORIZ 4
5
OFF
UP
UP
It is important to note that in environments that are exposed to
a high degree of vibration, the cables that connect to the circuit
breaker must be securely held in place, as the breaker is not
designed to carry the weight of the cables. A maximum of 35N
can be applied to the terminal area, in a direction perpendicular
to the mounting axis.
%
%
If the product is not vertically mounted in the normal DIN-rail
mounting orientation, a rating factor must be applied. Figure 1
shows a diagram of the rating factor to apply. The published
curves for these circuit breaker products are produced with
the circuit breaker in the vertical mounting position. The rating
factor only applies to the must hold and must trip points of the
curve as the other parts (instantaneous trip point) stay largely
unaffected.
10
5
107%
Accessories
Technical Data
Current Rating
Part Number Table - Example
80A max.
Voltage
Short Circuit Strength
500V max.
25kA
Type
Bus bar (1 pole, insulated 1m)
Bus bar (2 pole, insulated 1m)
Part No.
67101904
67101972
Bus bar (3 pole, insulated 1m)
67101971
To order 9926 Series Single Pole Circuit Breaker
Part No. 9926251100
• Current Rating of 1.0 amp
• Internal Resistance per Pole of 1.1 ohms
• Trip Curve – M1, Medium (Standard)
9 9 2 6 2 5 1 0 0 0
Amperage
Type
Part No.
Bus bar end cap, 1 pole
67101973
Bus bar end cap, 2 pole or 3 pole
67101974
"00" - 0.5A
"01" - 1A
"02" - 2A
/
"60" - 60A
Trip Curves
"0" - Branch AC KM (Standard)
"1" - Branch AC OP (Instantaneous)
"2" - Branch AC 1 (Fast)
"4" - Branch 80VDC 1 (Fast)
"5" - Supplemental 2 (Standard)
"6" - Branch 125VDC OP (Instantaneous)
"7" - Branch 80VDC OP (Instantaneous)
"8" - Branch 125VDC U2 (Standard)
"9" - Branch 80VDC U2 (Standard)
Technical Data
Current Rating
Wire Size
Dimensions
Poles
85A max.
10 AWG min., 4 AWG max.
A: 6 mm B: 32 mm
1 Pole
2 Pole
3 Pole
Type
Type
Power lug, straight
Part No.
67101960
Power lug, 90°
67101961
Type
Lock-out handle
"5" - Base Breaker
"6" - With Auxiliary Contact
"7" - With Trip Alarm Contact
"8" - Combo Aux/Trip Contact
"9" - GFCI
Part No.
67101913