Dimensions: [mm]
Recommended Hole Pattern: [mm]
Electrical Properties:
10,2
O 1,3
37,5 ±1,0
10,2 ±1,0
O 1,0 ±0,05
Properties
Unit
Tol.
C
Test conditions
1 V / 1 kHz ± 0.2 kHz
35
µF
±5%
Rated Voltage
VR
up to 85 °C
500
V (DC) max.
Rated Voltage
VR
@ 105 °C
365
V (DC) max.
Insulation Resistance
RISO
1 min @ 100 V (DC)
Dissipation Factor
DF
DF
Dissipation Factor
Rate of Voltage Rise
37,5
42,0 ±1,0
36,0 ±1,0
Value
Capacitance
Scale - 1:1,5
Schematic:
MΩ
min.
@ 1 kHz
0.15
%
max.
@ 10 kHz
1.5
%
max.
30
V/µs
max.
dV/dt
Dielectric Strength Pin to
Pin
10 sec.
750
V (DC) max.
Dielectric Strength Pin to
Case
10 sec.
2000
V (AC) max.
ESR
RESR
Ripple Current
IRIPPLE 10 kHz @ 70 °C
IPeak
Peak Current
4,0 ±0,5
285.71
@ 10 kHz
î = C[µF] · dV/dt
8
mΩ
typ.
13.5
A
max.
1050
A
max.
General Information:
24,0 ±1,0
DC-Link Capacitor; wound type; boxed; MKP-Metallized Polypropylene
Operating Temperature
-40 up to +105 °C
Storage Conditions
(in original packaging)
5 °C up to + 35 °C; 10 % up to 75 % RH
Maximum Selfheating (Rated)
15
Moisture Sensitivity Level (MSL)
°C
1
Climatic Category
40/85/56
Test conditions of electrical properties: +20 °C, 35 % RH if not specified differently
FIT according to separate documentation
Scale - 1:1,5
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
1/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Product Marking:
1st
Current Derating (Typical Curve):
Line right
Matchcode: FTDB
2nd Line
120%
Capacitance & Tolerance Code: 356J (Basis pF), Date Code (YWW), Rated Voltage: 500 V
Properties
Test Conditions
Lead Diameter [ mm ] Force [ N ]
condition
Termination Robustness
IEC 60068 - 2 - 21 Pull Test
0.5 to ≤ 0.8
10
min. 10 sec.
0.9 to ≤ 1.25
20
min. 10 sec.
0.5 to ≤ 0.8
5
min. 2 cycles
0.9 to ≤ 1.25
10
min. 2 cycles
Bend Test
Environmental Tests:
Properties
Standard
Vibration
IEC 61071 & IEC 60068 - 2 - 6
f = 10 Hz to 55 Hz; a = ± 0,35 mm; Test
duration per axis = 10 frequency cycles ( 3
axes offset from each other by 90° ), 1 octave/
min. 45 minutes per axis, 135 minutes in total.
Damp heat, steady state
IEC 61071 & IEC 60068 - 2 - 78
40 ± 2 °C, 93 ± 3 % RH, 56 days.
Change of temperature
IEC 61071 & IEC 60068 - 2 - 14
5 cycles, upper and lower temperature 30
minutes each, 3 minutes max. transfer time.
Endurance test
IEC 61071
85 °C, 1.3 VR, 1000 hours
Certification:
RoHS Approval
Compliant [2011/65/EU&2015/863]
REACh Approval
Conform or declared [(EC)1907/2006]
Applied Ripple Current / Rated Ripple Current [%]
Mechanical Properties:
100%
80%
60%
40%
20%
0%
40
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
50
60
70
80
Temperature [°C]
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
90
100
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
2/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Lifetime (Typical Curve):
Voltage Derating:
120%
130%
70 °C
110%
Rated DC Voltage / Max. DC Voltage [%]
Applied DC Voltage / Max. DC Voltage [%]
120%
110%
85 °C
100%
90%
80%
105 °C
70%
90%
80%
70%
60%
60%
50%
1000
100%
50%
10000
Expected Lifetime [h]
100000
40
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
50
60
70
80
Temperature [°C]
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
90
100
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
3/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Packaging Specification - Tray and Carton: [mm]
Packaging Specification - Outer Carton: [mm]
H
IC
H
C
Pearl Cotton
W
Tolerance
Value
LIC
(mm)
typ.
350,00
WIC
(mm)
typ.
250,00
L
IC
HIC
(mm)
typ.
60,00
No. of
Layer (pcs.)
1
No. of
Pearl Cotton (pcs.)
1
IC
W
Qty.
(pcs.)
80
Material
Paper
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
Tolerance
Value
L
C
LC
(mm)
typ.
375,00
WC
(mm)
typ.
265,00
HC
(mm)
typ.
265,00
C
No. of
Inner Carton (pcs.)
Qty.
(pcs.)
Material
4
320
Paper
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
4/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Classification Wave Soldering Profile:
Classification Wave Soldering Profile:
Profile Feature
tp
Tp
Preheat Temperature Min
Preheat Temperature Typical
First Wave
Second Wave
Preheat Temperature Max
Sn-Pb Assembly
100 °C
100 °C
Ts typical 120 °C
120 °C
Ts max
130 °C
130 °C
ts
70 seconds
70 seconds
Ramp-up Rate
ΔT
150 °C max.
150 °C max.
Peak Temperature
Tp
250 °C - 260 °C
235 °C - 260 °C
Time of actual peak temperature
tp
max. 10 seconds
max. 5 seconds each wave
max. 10 seconds
max. 5 seconds each wave
Preheat Time ts from Ts min to Ts max
Temperature
Pb-Free Assembly
Ts min
Ts max
Ts typical
Ramp-down Rate, Min
~ 2 K/ second
~ 2 K/ second
Ramp-down Rate, Typical
~ 3.5 K/ second
~ 3.5 K/ second
Ts min
Ramp-down Rate, Max
~ 5 K/ second
~ 5 K/ second
Time 25 °C to 25 °C
4 minutes
4 minutes
refer to EN61760-1:2006
Preheat area
Cool down area
Time
typical temperature procedure
min temperature procedure
max temperature procedure
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
5/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Cautions and Warnings:
The following conditions apply to all goods within the product series of Film Capacitors
of Würth Elektronik eiSos GmbH & Co. KG:
General:
• This electronic component is designed and manufactured for use in general electronic equipment.
• Würth Elektronik must be asked for a written approval (following the certain PPAP level procedure) before incorporating the components
into any equipment in the field such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train
control, ship control), transportation signal, disaster prevention, medical, public information network etc. where higher safety and
reliability are especially required and/or if there is the possibility of direct damage or human injury.
• Electronic components that will be used in safety-critical or high-reliability applications, should be pre-evaluated by the customer.
• Direct mechanical impact to the product shall be prevented as material of the body, pins or termination could flake or in the worst case
it could break.
• Avoid any water or heavy dust on capacitors surface, which may cause electrical leakage, damage, overheating or corrosion.
• Würth Elektronik products are qualified according to international standards, which are listed in each product reliability report. Würth
Elektronik does not warrant any customer qualified product characteristic, beyond Würth Elektronik specifications, for its validity and
sustainability over time.
• The customer is responsible for the functionality of his or her own products. All technical specifications for standard products also apply
to customer specific products.
• The component is designed and manufactured to be used within the datasheet specified values. If the usage and operation conditions
specified in the datasheet are not met, the body, pins or termination may be damaged or dissolved.
• Do not apply any kind of flexural or compressive force onto soldered or unsoldered component.
• The capacitance tolerance as specified within the datasheet is only valid on the date of delivery and according specified measurement
criteria.
• The storage conditions stated in the original packaging apply to the storage time and not to the transportation time of the components.
Operating climatic conditions
• Do not exceed the lower nor the upper specified temperature under no circumstances.
• Do not use the capacitors under high humidity, high temperature or under high or low atmospheric pressure which may affect capacitors
reliability.
• Surface temperature including self-heating must be kept below the maximum operating temperature.
Operating load conditions
• Due to self-heating the reliability of the capacitor may be reduced, if high frequency AC or pulse is applied.
• Consider carefully possible specific changes of electrical characteristics like capacitance over temperature, voltage and time as well as
the specific performance over frequency for the actual use conditions.
• Avoid any overvoltage and do not apply a continuous overvoltage. If an overvoltage is applied to the capacitor, the leakage current can
increase drastically. The applied working voltage is not allowed to exceed the rated working voltage of the specific capacitor.
• If film capacitors with safety approvals are operated with a DC voltage exceeding the specified AC voltage, the approvals given on the
basis of IEC 60384-14 are no longer valid.
• For the WCAP-FTDB film capacitor the maximum peak voltage Vpeak+ shall not be greater than the rated voltage VR according to the
temperature derating of the rated voltage VR. The peak-to-peak value of the ripple voltage Vp-p should not be greater than 0.3*VR
according to the temperature derating of the rated voltage VR. The rated voltage of the capacitor may need to be reduced for different
operating temperatures. See voltage derating curve within this datasheet.
Packaging:
• The packaging specifications apply only to purchase orders comprising whole packaging units. If the ordered quantity exceeds or is
lower than the specified packaging unit, packaging in accordance with the packaging specifications cannot be ensured.
Product specific
Soldering
Storage conditions
• The solder profile must comply with the Würth Elektronik technical soldering specification. All other profiles will void the warranty.
• All other soldering methods are at the customer’s own risk.
• Strong forces which may affect the coplanarity of the component’s electrical connection with the PCB (i.e. pins), can damage the part,
resulting in void of the warranty.
• Customer needs to ensure that the applied solder paste, the paste thickness and solder conditions are enough to guarantee a sufficient
solder result according to the relevant criteria of IPC-A-610.
• Excessive amount of solder may lead to higher tensile force and chip cracking. Insufficient amount of solder may detach the capacitor
due to defective contacts.
• Do not use excessive nor insufficient flux.
• A storage of Würth Elektronik products for longer than 12 months is not recommended. Within other effects, the terminals may suffer
degradation, resulting in bad solderability. Therefore, all products shall be used within the period of 12 months based on the day of
shipment.
• Do not expose the components into direct sunlight.
• The storage condition in the original packaging is defined according to DIN EN 61760-2.
• The environment in which the capacitors are operated and stored has to have atmospheric characteristics and must be free of dew
condensation and toxic gases (e.g. chlorine, ammonia, sulfur, hydrogen sulphide and hydrogen sulfate).
• Do not expose the capacitor to environments with hazardous gas, ozone, ultraviolet rays or any kind of radiation. Avoid any contact of the
capacitor with direct sunshine, saltwater, spray of water or types of oil during storage.
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
6/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Cleaning
• Do not use any other cleaning solvents for box-typed capacitors except: ethanol, isopropanol, n-propanol - water mixtures. After
cleaning a drying process with temperatures not exceeding 65°C and not longer than 4 hours is mandatory to prevent any kind of
electrical damage.
Coating, molding and potting of the PCB
• If the product is potted in the costumer’s application, the potting material might shrink or expand during and after hardening. Shrinking
could lead to an incomplete seal, allowing contaminants into the body and termination. Expansion could damage the body or
termination. We recommend a manual inspection after potting to avoid these effects.
• If final assemblies will be placed completely in any plastic resin, physical, chemical and thermal influences must be considered.
• When coating and molding the PCB, verify the quality influence on the capacitor.
• Verify the curing temperature and assure that there is no harmful decomposing or reaction gas emission during curing.
• Do not exceed the specified max. self-heating.
Vibration resistance
• Do not exceed the vibration limits given by IEC60068-2-6.
Handling
•
•
•
•
•
After soldering, please pay attention not to bend, twist or distort the PCB in handling and storage.
Avoid excessive pressure during the functional check of the PCB.
Avoid bending stress while breaking the PCB.
WCAP-FTXX and WCAP-FTX2 capacitors are not designed and not recommended to be used in series connection to the mains.
The temperature rise of the component must be taken into consideration. The operating temperature is comprised of ambient
temperature and temperature rise of the component.The operating temperature of the component shall not exceed the maximum
temperature specified.
Flammability
• Avoid any external energy or open fire (passive flammability).
These cautions and warnings comply with the state of the scientific and technical knowledge and are believed to be accurate and reliable.
However, no responsibility is assumed for inaccuracies or incompleteness.(V2.2)
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
7/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Important Notes
6. Product Life Cycle
The following conditions apply to all goods within the product range of Würth Elektronik
eiSos GmbH & Co. KG:
Due to technical progress and economical evaluation we also reserve the right to discontinue production and delivery of products. As a
standard reporting procedure of the Product Termination Notification (PTN) according to the JEDEC-Standard we will inform at an early stage
about inevitable product discontinuance. According to this we cannot guarantee that all products within our product range will always be
available. Therefore it needs to be verified with the field sales engineer or the internal sales person in charge about the current product
availability expectancy before or when the product for application design-in disposal is considered. The approach named above does not
apply in the case of individual agreements deviating from the foregoing for customer-specific products.
1. General Customer Responsibility
Some goods within the product range of Würth Elektronik eiSos GmbH & Co. KG contain statements regarding general suitability for certain
application areas. These statements about suitability are based on our knowledge and experience of typical requirements concerning the
areas, serve as general guidance and cannot be estimated as binding statements about the suitability for a customer application. The
responsibility for the applicability and use in a particular customer design is always solely within the authority of the customer. Due to this
fact it is up to the customer to evaluate, where appropriate to investigate and decide whether the device with the specific product
characteristics described in the product specification is valid and suitable for the respective customer application or not.
2. Customer Responsibility related to Specific, in particular Safety-Relevant Applications
It has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime
cannot be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications.
In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable
design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic
component. Therefore, customer is cautioned to verify that data sheets are current before placing orders. The current data sheets can be
downloaded at www.we-online.com.
7. Property Rights
All the rights for contractual products produced by Würth Elektronik eiSos GmbH & Co. KG on the basis of ideas, development contracts as
well as models or templates that are subject to copyright, patent or commercial protection supplied to the customer will remain with Würth
Elektronik eiSos GmbH & Co. KG. Würth Elektronik eiSos GmbH & Co. KG does not warrant or represent that any license, either expressed or
implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination,
application, or process in which Würth Elektronik eiSos GmbH & Co. KG components or services are used.
8. General Terms and Conditions
Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms and Conditions of Würth
Elektronik eiSos Group”, last version available at www.we-online.com.
3. Best Care and Attention
Any product-specific notes, cautions and warnings must be strictly observed. Any disregard will result in the loss of warranty.
4. Customer Support for Product Specifications
Some products within the product range may contain substances which are subject to restrictions in certain jurisdictions in order to serve
specific technical requirements. Necessary information is available on request. In this case the field sales engineer or the internal sales
person in charge should be contacted who will be happy to support in this matter.
5. Product R&D
Due to constant product improvement product specifications may change from time to time. As a standard reporting procedure of the
Product Change Notification (PCN) according to the JEDEC-Standard inform about minor and major changes. In case of further queries
regarding the PCN, the field sales engineer or the internal sales person in charge should be contacted. The basic responsibility of the
customer as per Section 1 and 2 remains unaffected.
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
FPu
001.000
2022-10-13
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
TECHNICAL REFERENCE
WCAP-FTDB DC-Link Capacitor
MDBP375356J500DCPP15041
ORDER CODE
890484428002CS
SIZE/TYPE
BUSINESS UNIT
STATUS
PAGE
Pitch 1: 37.5 mm; Pitch 2: 10.2 mm
eiCap
Valid
8/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.