ACM06 Series
AC-DC Power Supplies
6 Watt
xxx Series
• Energy Efficiency Level VI
• European CoC Tier 2
• Medical and ITE Approvals
• Interchangeable Mains Connectors
• Optional White Versions
• Output Voltages from 5 V to 12 V
• Class II Construction
• 3 Years Warranty
The ACM06 series of wall plug adaptors comply with the latest energy efficiency level VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector as well as USB versions, these adaptors suit a wide variety of cost
sensitive industrial and medical applications while maintaining industry leading performance.
Dimensions:
ACM (body only):
2.89 x 1.21 x 1.67” (73.5 x 30.7 x 42.5 mm)
Models & Ratings
Output Power
6W
Output Voltage
Output Current
Total Regulation(3)
Efficiency(4)
Model Number(1,2,5)
5.0 V
9.0 V
1000 mA
600 mA
5%
5%
80.0%
79.8%
ACM06US05(6)
ACM06US09
12.0 V
500 mA
5%
82.0%
ACM06US12
Notes
1. Model number is for body only. AC input plugs must be ordered separately, see
AC input plug section.
2. Other output voltages available, contact sales for details.
3. Total regulation includes initial set accuracy, line and load regulation.
4. Typical average value measured at 115 VAC.
5. For white case version add suffix ‘-W’ e.g. ACM06US12-W. MOQ applies, contact
sales for details.
6. For 5 V version with optional USB type A connector in case, add suffix -BB,
e.g ACM06US05-BB.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Minimum
90
47
Typical
Maximum
264
63
0.2
70
Units
VAC
Hz
A
A
75
mW
Maximum
12
5
Units
V
A
s
ms
ms
%
4
% deviation
Notes & Conditions
100 VAC
240 VAC, cold start at 25 °C
EN61000-3-2, class A
Internal fuse in line
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Transient Response
1
Minimum
5
0
Typical
4
30
10
Ripple & Noise
150
mV pk-pk
Short Circuit Protection
Temperature Coefficient
0.05
%/ ˚C
Notes & Conditions
See Models and Ratings table
No minimum load required
Full load and 100 VAC
See Models and Ratings table
For a 50% step load change at 0.15 A/μs
Measured with 20 MHz bandwidth and 10 μF electrolytic in
parallel with 0.1 μF ceramic capacitor
Continuous, trip and restart (hiccup mode) with auto recovery
www.xppower.com
ACM06 Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Maximum
Units
80
Efficiency
Notes & Conditions
Typical average of efficiencies measured at 25%,
50%, 75% and 100% load and 115 VAC input
%
Energy Efficiency
Isolation
Level VI
4000
20
Leakage Current
Switching Frequency
24
Mean Time Between Failure
250
Weight
VAC
Input to Output, 2 x MOPP
100
µA
At 264 VAC, 60 Hz, from output to ground
70
kHz
kHrs
Variable
lb (g)
Body only
0.22 (100)
MIL-HDBK-217F at 25 °C GB
Environmental
Characteristic
Operating Temperature
Storage Temperature
Operating Humidity
Minimum
Typical
Maximum
Units
0
+60
°C
-20
5
+85
90
°C
%
5000
m
Operating Altitude
Notes & Conditions
Derate from 100% load at 40 °C to 50% load
at 60 °C
RH, non-condensing
Cooling
Natural convection
Shock
1 m drop onto concrete on each of 6 axes, non
operating
Vibration
300
10
Hz
2 g, 0.3 decades/min, 15 mins for each of 3 axes
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55032
Level B
Radiated
EN55032
Level B
Harmonic Current
EN61000-3-2
Class A
Voltage Flicker
EN61000-3-3
Notes & Conditions
EMC: Immunity
Phenomenon
Medical Device EMC
Low Voltage PSU EMC
Standard
Test Level
Criteria
IEC60601-1-2
Ed.4.0 : 2014
as below
EN61204-3
High severity level
as below
ESD Immunity
EN61000-4-2
±8 kV contact, ±15 kV air
A
Radiated Immunity
EN61000-4-3
10 V/m
A
EFT/Burst
EN61000-4-4
Level 3
A
Surge
EN61000-4-5
Level 2
A
Conducted Immunity
EN61000-4-6
6V
A
Magnetic Fields
EN61000-4-8
30 A/m
Dip: 100% 10 ms
Dip: 70% 500 ms
A
A
B
Int: 100% 5000 ms
B
Dip: 30% 25 AC Cycles
A
EN61000-4-11
Dips and Interruptions
EN60601-1-2
Int: 100% 0.5 AC Cycle
At 8 angles, A at 115 VAC, B at 100 VAC
Int: 100% 1 AC Cycle
B
Int.: >95% 5000 ms
B
www.xppower.com
Notes & Conditions
2
ACM06 Series
AC-DC Power Supplies
Safety Approvals
Certification
Safety Standard
Notes & Conditions
UL60950-1, UL62368-1
UL
EN
CB
Information Technology
ANSI/AAMI ES 60601-1
Medical, 2 x MOPP
EN60950-1, EN62368-1
Information Technology
EN60601-1
Medical, 2 x MOPP
IEC60950-1, IEC62368-1
Information Technology
IEC60601-1
Medical, 2 x MOPP
CSA
CSA C22.2 No. 60601
Medical, 2 x MOPP
CCC
China Compulsory Certification, GB4943
AU/NZ
AU/NZ 60950.1
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Mechanical Details
ACM06USXX
70.8 (1800 ±10%)
2.89 ±0.03 (73.5 ±1.0)
0.43 ±0.01 (11.0 ±0.05)
1.67 ±0.03
(42.5 ±1.0)
ø0.09 (ø2.5)
ø0.21 (ø5.5)
1.20 ±0.03
(30.7 ±1.0)
2.89 ±0.03 (73.5 ±1.0)
ACM06US05-BB
1.67 ±0.03
(42.5 ±1.0)
1.20 ±0.03
(30.7 ±1.0)
Notes
ACM06USXX output plug ø5.5 x ø2.5 x 11.0mm, centre positive.
ACM06USXX output lead: UL2468, 18 AWG.
3
www.xppower.com
3
ACM06 Series
AC-DC Power Supplies
AC Input Plugs
Black UK Plug: ACM PLUG UK
White UK Plug: ACM PLUG UK W
Black USA Plug: ACM PLUG US
White USA Plug: ACM PLUG US W
1.73 (44.1)
±0.02 (±0.6)
1.25 (32.0)
±0.11 (±0.5)
0.15 (3.97)
±0.1 (±0.15)
R3
1.94 (49.4)
±0.02 (±0.6)
1.16 (29.5)
±0.11 (±0.5)
0.05 (1.5) ±0.003 (±0.1)
R3
0.87 (22.2)
±0.1 (±0.15)
0.24 (6.3)
±0.003 (±0.1)
0.62 (16.0) ±0.01 (±0.5)
0.35 (9.0) ±0.11 (±0.5)
0.27 (7.0)
±0.007 (±0.2)
0.5 (12.7)
±0.007 (±0.2)
0.69 (17.7)
±0.01 (±0.5)
0.89 (22.7)
±0.01 (±0.5)
0.66 (17.0)
±0.11 (±0.5)
0.03 (4.0)
±0.003 (±0.1)
1.26 (22.25)
±0.007 (±0.2)
0.31 (7.9)
±0.003 (±0.1)
Black Australian Plug: ACM PLUG AU
White Australian Plug: ACM PLUG AU W
Black European Plug: ACM PLUG EU
White European Plug: ACM PLUG EU W
0.35 (9.0)
±0.01 (±0.3)
R 0.8 (20.5)
1.16 (29.5)
±0.02 (±0.6)
1.16 (29.5)
±0.02 (±0.6)
0.06 (1.6)
±0.1 (±0.003)
1.25 (32.0)
±0.02 (±0.6)
1.26 (32.1) ±0.02 (±0.6)
0.24 (6.3)
±0.1 (±0.003)
0.7 (17.8)
±0.02 (±0.6)
0.34 (8.8)
±0.1 (±0.003)
1.40 (35.6)
±0.01 (±0.6)
0.71 (18.2)
±0.01 (±0.5)
0.35 (9.0)
±0.01 (±0.5)
1.16 (29.5)
±0.01 (±0.6)
0.6 (17.0)
0.69 (17.6)
±0.007 (±0.2)
0.55 (14.1)
±0.01 (±0.5)
0.74 (19.0)
±0.01 (±0.5)
1.61 (41.0) ±0.02 (±0.6)
Black China Plug: ACM PLUG CN
White China Plug: ACM PLUG CN W
1.16 (29.5) ±0.01 (±0.5)
0.35 (9.0)
±0.01 (±0.5)
1.25 (32.0)
±0.01 (±0.5)
0.62 (16.0)
±0.01 (±0.5)
0.24 (6.3) ±0.003 (±0.1)
0.05 (1.5)
±0.003 (±0.1)
0.5 (12.7)
±0.007 (±0.2)
www.xppower.com
17 July 2021
很抱歉,暂时无法提供与“ACM06US09”相匹配的价格&库存,您可以联系我们找货
免费人工找货