AC-DC
120 Watts AMM120 Series
• • • • • • • Energy Star Level V ≥ 24 V
xppower.com
CEC 2008 & EISA 2007 Compliant Worldwide Medical Approvals Small Size/High Power Density Class I and Class II Versions Operating Temperature up to +60 °C Locking Output Connector
Specification
Input
Input Voltage Input Frequency Input Current • 90-264 VAC • 47-63 Hz • 1.6 A rms at 115 VAC, 0.8 A rms at 230 VAC Inrush Current • 60 A at 115 VAC, 120 A at 230 VAC, cold start +25 °C Power Factor • 0.98 typical Earth Leakage Current • 90 µA max at 115 VAC/60 Hz, (Class I Versions) 150 µA max at 230 VAC/50 Hz Input Protection • Internal 3 A fuse in live and neutral lines
General
Efficiency Isolation • 85% typical • 4000 VAC Input to Output 1500 VAC Input to Ground (Class I only) 500 VAC Output to Ground (Class I only) • 40-120 kHz variable • 3.7 W/In3 • >175 kHrs per MIL-HDBK-217F
Switching Frequency Power Density MTBF
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power at +40 °C to 50% power at +60 °C Cooling • Convection-cooled Operating Humidity • 10-95% RH, non-condensing Storage Temperature • -20 °C to +80 °C Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response 12 to 48 VDC Not user-adjustable ±2 % No minimum load required 2 s max at 115 VAC