ASB160 Series
160W
AC-DC
AC-DC POWER
POWER SUPPLIES
SUPPLIES
BASEPLATE
COOLED
The ASB160 series is a range of complete low profile, full brick, baseplate cooled AC-DC
power supplies which requires no external components.
The series includes a complete built in EMC filter and AC fuse as well as bulk storage
capacitor providing a complete AC-DC power solution ready for installation into end
applications.
The ASB160 offers high efficiency to minimise waste heat and heat sinking requirements
and operates from -40°C to +90°C on the module baseplate.
Features
Applications
• Complete AC-DC power supply
• No extra components required
• Baseplate cooled full brick package
• Low profile
• Input range 90 to 264VAC
AC-DC
Converters
Industrial
Electronics
Instrumentation
Railway
Security
Technology
• Single outputs from 12 to 54VDC
• Output voltage trim ±5%
• High efficiency - up to 93%
• Over current, over voltage and over temperature protection
• Optional heatsink available
• -40 to +90°C baseplate operating temperature
Dimensions
• 3 year warranty
2.40 x 4.60 x 0.78” (61.0 x 116.8 x 19.7 mm)
Models & Ratings
Model number(1)
Output Voltage
Output Current
Ripple & Noise
Efficiency(2)
ASB160PS12
12.0V
13.30A
120mV
92.0%
ASB160PS15
15.0V
10.66A
150mV
93.0%
ASB160PS24
24.0V
6.66A
240mV
92.0%
36.0V
4.44A
360mV
93.0%
ASB160PS48
48.0V
3.33A
480mV
93.0%
ASB160PS54
54.0V
2.96A
540mV
91.0%
ASB160PS36
Output Power
160W
`
Notes:
1. Add suffix ‘-HK’ to receive with optional heat-sink fitted.
3. Optional heatsink can be ordered as a separate item using
part number IFH HEATSINK
2. Typical efficiency with 230VAC input and full load.
ASB160 Series
AC-DC POWER SUPPLIES
Input
Characteristic
Minimum
Input Voltage
90
Input Frequency
47
Typical
Maximum
Units
264
VAC
63
Hz
1.7/0.82
Input Current
Inrush Current
Earth Leakage Current
A
115VAC/230VAC
100
A
230VAC, cold start at 25°C
750
µA
264VAC, 60Hz
0.9
Power Factor
Notes & Conditions
Full load
No Load Input Power
0.5/0.7
W
Maximum
Units
12V-48V/54V
Internal T3.15A/250VAC fitted in line
Input Protection
General
Characteristic
Minimum
Typical
92
Efficiency
%
Isolation: Input to Output
3000
VAC
Input to Ground
1500
VAC
Output to Ground
500
VAC
180
250
kHz
100
150
Switching Frequency
18.5
Power Density
Mean Time Between Failure
See models and ratings table
Main converter, variable, load dependant
PFC
W/in3
160
khrs
0.62 (280)
Weight
Notes & Conditions
MIL-HDBK-217F at 25°C GB and 115VAC
lb(g)
Output
Characteristic
Output Voltage
Minimum
12
Maximum
Units
Notes & Conditions
54
VDC
See Models and Ratings table
1
Initial Set Accuracy
Output Voltage Trim
Typical
95
%
At 60% load
105
%
Of nominal output voltage. See application note
1.3
s
10
ms
No minimum load required
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
8
10
ms
Full load and 115VAC
Line Regulation
±0.5
%
Load Regulation
±0.5
%
Transient Response
2
%
Maximum deviation, recovering to less than 1% within
300µs for 25% step load
Ripple and Noise
1
% pk-pk
20MHz bandwidth, measured with 20MHz Bandwidth
and 10µF electrolytic in parallel with 0.1µF ceramic
capacitor
Overload Protection
110
140
%
Overvoltage Protection
110
150
%
Short Circuit Protection
Trip and restart (hiccup), auto resetting
Thermal Protection
Measured internally at the baseplate, auto resetting
Temperature Coefficient
Remote Sense
0.02
5
Auto recovery except 54V version recycle AC to reset
%/°C
After 20 minute warm up
%
Maximum compensation
2
ASB160 Series
AC-DC POWER SUPPLIES
Environmental
Characteristic
Operating Temperature
Minimum
Typical
Maximum
-40
Units
+90
°C
5
90
%RH
-40
+90
°C
5000
m
Notes & Conditions
Baseplate Temperature, see derating curve
Conduction cooled via baseplate
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Shock
IEC68-2-27, 30g, 11ms half sine, 3 times in each of 6 axes
Vibration
IEC68-2-6, 10-500Hz, 2g 10 mins/sweep, 60 mins for each of 3 axes
Non-condensing
EMC: Emissions
Phenomenon
Standard
Test Level
EN55032
Level B
Harmonic Currents
EN61000-3-2
Class A
Voltage Flicker
EN61000-3-3
Conducted
ESD
Notes & Conditions
EMC: Immunity
Phenomenon
Standard
Radiated
Radiated Immunity
EFT/Burst
Surge
Conducted
EN61000-4-6
Dips and Interruptions
Test Level
Criteria
EN61000-4-2
3/2
A
EN61000-4-3
3V/m
A
EN61000-4-4
2
A
EN61000-4-5
Installation Class 3
A
EN61000-4-11
Notes & Conditions
±8kV air/±4kV contact
3V
A
Dip: 100% 10ms
A/B
High Line/Low Line
Dip: 30% 500ms
A/B
High Line/Low Line
Int: 100% 5000ms
B
Safety Approvals
Safety Agency
Standard
UL
UL62368-1
TUV
EN62368-1
CB
IEC62368-1
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Notes & Conditions
3
ASB160 Series
AC-DC POWER SUPPLIES
Mechanical Details
4.20 (106.7)
4.20 (106.7)
0.299(7.60)
(7.60)
0.299
FG
FG
Earth
Earth
Moun ng inserts ø0.13 (3.2) through 4 places
Moun ng inserts ø0.13 (3.2) through 4 places
4.20 (106.7)
4.20 (106.7)
0.299(7.60)
(7.60)
0.299
ACN
ACN
0.299(7.60)
(7.60)
0.299
+Sen
+Sen
+Vout
+Vout
Trim
Trim
-Vout
-Vout
-Sen
-Sen
ACL
ACL
0)
(1.00)
39 1.00
0.039 (2
0 ))
.
(
3- 0.079 2.00
3- 0.0 9 (
5- 0.07
5-
0.299(7.60)
(7.60)
0.299
0.400
(10.16)
0.400
(10.16)
0.400
(10.16)
0.400
(10.16)
2.00
(50.8)
2.00
(50.8)
2.40
(61.0)
2.40
(61.0)
0.20 (5.1)
0.20 (5.1)
0.23
(5.9)
0.23
(5.9)
0.78
(19.7)
0.78
(19.7)
Grey
Grey
4.60 (116.8)
4.60 (116.8)
Heatsink Option
4.20 (106.7)
4.20 (106.7)
1.0 (25.4)
1.0 (25.4)
4.60 (116.8)
4.60 (116.8)
Notes:
1. Dimensions shown in inches (mm).
2. Weight: 0.62lb (280g)
3. Pin diameter: 0.08 ±0.002 (2.0 ±0.05)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
6. Baseplate is connected to FG Pin
Derating Curve
0
0
-40 -30
-40 -30
-20
-20
-10
-10
0
10
0
10
20
30
20
30
40
40
50
Ambient
Ambient
Temperature
Temperature
(°C) (°C)
50
60
60
70
70
80
80
90
90
Load (%)
50
50
100
Some specification
parameters
may not be met
Some specification
parameters
may not be met
100
With IFH
With
HEATSINK
IFH HEATSINK
Load (%)
Load (%)
50
100
Some specification
parameters
may not be met
Some specification
parameters
may not be met
Load (%)
100
50
0
0
-40 -30
-40
-30
-20
-20
-10
-10
0
10
0
10
20
30
20
30
40
40
50
50
60
60
70
70
80
80
90
100
90
100
Baseplate
Baseplate
Temperature
Temperature
(°C) (°C)
When ASB160 is fitted with IFH HEATSINK and mounted in horizontal position with heatsink upper most, the baseplate temperature will typically be 85°C in an
Lifetime
Lifetime
ambient
of 40°C.
KHrs
KHrs
400
400
200
200
100
50
100
50
4
Rd
Trim Trim
Load Load
ASB160 Series
-Vo -Vo
Ru
Load Load
100
90
Efficiency (%)
Efficiency Curves
80
ASB160PS12
70
60
80
70
70
60
60
50
50
10
70
40
50
60
70
80
90
50
100
10 20
2030
30 40
4050
50 60
6070
70 80
8090
230 VAC
100 100
10
Efficiency (%)
Efficiency (%)
9020 90 30
80
115 VAC
ASB160PS24
60
100 100
10
80
90100 100
90 20 90
Efficiency (%)
90
30
80
80
70
70
60
60
50
50
10
40
50
60
70
80
90
100
115 VAC
115
230 VAC
230
10 20
2030
30 40
4050
50 60
6070
70 80
80 90
90100 100
Output Voltage Adjustment
Trim down
Trim up
+Vo
+Vo
Trim
Rd
Trim
Load
-Vo
Ru
Load
-Vo
To Trim Down
Connecting an external resistor (Rd) between the Trim pin and the +Vo pin decreases the output voltage. The following table can be used to determine the required external
resistor value to obtain a percentage output voltage change of 5%.
12V
Trim Down (%)
15V
24V
100
5
288.7
398.5
Efficiency (%)
50
Ru
-Vo -Vo
100
Efficiency (%)
Efficiency (%)
0
Trim Trim Rd
36V
48V
54V
1215
1776
2005
Rd (kΩ)
738
90
80
115 VAC
To Trim Up
230 VAC
Connecting an external resistor (Ru) between the Trim pin and the -Vo
pin
increases
the
output
voltage.
The
following
table
can
be
used
to
determine
the
required
external
70
resistor value to obtain a percentage output voltage change of 5%.
60
20
30 Up (%)
40
Trim
5
50
60
12V
70
79
80
90
15V
100
84
50
10
20
24V
30
40
50
Ru (kΩ)
90.8
18 January 2023
36V
60
92.8
70
80
48V
90
89.4
100
54V
90.8
35
很抱歉,暂时无法提供与“ASB160PS12”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+1614.718161+200.30504
- 5+1566.290835+194.29765
- 10+1517.8427510+188.28769
- 25+1453.2552625+180.27564
- 100+1356.36989100+168.25706