CPB600PS24

CPB600PS24

  • 厂商:

    XPPOWER

  • 封装:

  • 描述:

    CPB600PS24 - AC-DC Chassis Mount - XP Power Limited

  • 数据手册
  • 价格&库存
CPB600PS24 数据手册
AC-DC Chassis Mount 400-650 Watts CPB600 Series • THE XPERTS IN POWER Universal PFC Input • Low Profile (61mm) • Wide Output Voltage Adjustment • Remote ON/OFF • Power Good Signal • Remote Sense • Peak Current Available Specification Input Input Voltage Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current • • • • • • 95-264 VAC (120-370 VDC) 47-63 Hz 8.2 A max at 115 VAC 40 A max at 230 VAC 0.98/0.95 at 115/230 VAC 0.75 mA max at 230 VAC 60 Hz Remote ON/OFF • 12 V 3 mA applied between RCG & RC2 will inhibit the output of the unit & the fan General Efficiency Isolation • • See Table 3000 VAC Input to Output 2000 VAC Input to Ground 500 VAC Output to Ground 130kHz PFC, 330 kHz PWM Output Output Voltage Output Voltage Adjustment Minimum Load Start-Up Time Hold-up Time Drift Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overload Protection • • • • • • • • • • • See Table See Table No minimum load required 400 ms typical at 230 VAC, 100% load 20 ms typical at 100% load ±0.4% max ±0.5% max ±1.0% max 0-100% load ± 1% max pk-pk 20 MHz bandwidth 110-130% of Vnom Recycle input to reset Operates at 105% of rated current (101% of pk rating), 5 s recycle input to reset ±1.25% max -20 °C to +50 °C Operates in the event of fan failure or if the operating temperature/ derating criteria is exceeded Compensates for 0.3 V drop max If not required sense terminals must be connected locally ie: +S to +M and -S to -M on CN1 Switching Frequency • Environmental Operating Temperature Storage Temperature Relative Humidity Shock Vibration • • • • • -20 °C to +70 °C, derate linearly above +50 °C to 50% at +70°C -20 °C to +75 °C 20-90% non condensing 20 G 11 ms, once each x, y and z axis 2 G 10-55Hz for 3 min periods for 60 min along each x, y and z axis EMC & Safety Emissions ESD Susceptibility Radiated Susceptibility EFT/Burst Surge Safety Approvals • • • • • • EN55022 Level B conducted EN55022 Level A radiated EN61000-4-2 Level 2 contact, Level 3 air EN61000-4-3 Level 3 EN61000-4-4 Level 3 EN61000-4-5 Level 3 line to line Level 4 line to ground UL60950, C-UL (CSA 60950) EN60950 Temperature Coefficient Overtemperature Protection Remote Sense • • • • • www.xpplc.com sales@xpplc.com OUTPUT VOLTAGE & CURRENT RATINGS Output Voltage 3.3 V (2.64-3.96) 5.0 V (3.96-6.00) 7.5 V (5.25-8.25) 12.0 V (8.25-13.2) 15.0 V (10.50-16.5) 24.0 V (16.5-26.4) 36.0 V (25.2-39.6) 48.0 V (38.4-56.0) Current Max 120 A 120 A 80 A 53 A 43 A 27 A 18 A 13 A Peak 31 A(1) Regulation Line Load 20 mV 40 mV 20 mV 40 mV 36 mV 60 mV 48 mV 100 mV 60 mV 120 mV 96 mV 150 mV 144 mV 150 mV 192 mV 300 mV Ripple Noise(2) 120 mV 120 mV 150 mV 150 mV 150 mV 150 mV 200 mV 200 mV Efficiency 72% 77% 79% 82% 82% 84% 84% 83% (3) CPB Model CPB600PS3V3 CPB600PS05 CPB600PS7V5 CPB600PS12 CPB600PS15 CPB600PS24 CPB600PS36 CPB600PS48 • Notes 1. Peak current duration 100 ms max with a duty cycle ≤35% 170-264 VAC only. 2. Measured over a 20 MHz bandwidth and from 0 °C to +50 °C. 3. Measured at nominal 230 VAC input and 100% load. Mechanical Details Weight 3.4kg Pin 1 2 3 4 5 6 7 8 9 10 CN1/CN2 PIN CONNECTIONS Function +M + Output Voltage Monitoring +S + Remote Sensing -M - Output Voltage Monitoring -S - Remote Sensing VB Voltage Balance CB Current Balance TRM Adjustment of Output Voltage -S - Remote Sensing RC2 Remote ON/OFF RCG Remote ON/OFF Ground Pin 1 2 3 4 5 6 7 8 CN3 PIN CONNECTIONS Function -S - Remote Sensing -S - Remote Sensing AUX Auxiliary Output (12 V/0.1A) RC1 Remote ON/OFF AUXG AUX Ground N.C. No Connection PG Power Good Signal PGG Power Good Ground Output Voltage Adjustment 60-110% of the rated output voltage is achieved by: 1. Using on-board potentiometer. 2. Applying a voltage externally between TRM & -S on CN1 or CN2. 3. Connecting a resistor externally between TRM & -S on CN1 or CN2. The external voltage level is calculated below & should not be less than -0.7 V or more than 3.0 V. External Trim Voltage = Required Vout x 2.5 Vnom Mating Connector & Terminal for CN1, CN2 & CN3 Connector CN1 S10B-PHDSS CN2 CN3 S8B-PHDSS Mating Connector PHDR-10VS PHDR-8VS Terminal Reel Loose SPHD-002T-P0.5 BPHD-001T-P0.5 BPHD-002T-P0.5 J.S.T Mfr www.xpplc.com sales@xpplc.com Rev 2.0
CPB600PS24 价格&库存

很抱歉,暂时无法提供与“CPB600PS24”相匹配的价格&库存,您可以联系我们找货

免费人工找货