ACDC
1015 Watts
xppower.com
CU1015 Series
•
Low Cost
•
Small Size
•
PCB Mount
•
15 Watt Medical Version
•
Single Output 3.324 V
•
Peak Load Capability
•
Nonstandard Outputs Available
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 85-264 VAC (120-370 VDC)
• 47-63 Hz
• 0.13 A rms at 230 VAC (CU10)
0.20 A rms at 230 VAC (CU15)
Inrush Current
• 20 A at 115 VAC, 40 A at 230 VAC,
cold start 25 º C
Earth Leakage Current • Class 2 (no earth)
Input Protection
• 1A fuse (CU10)
2A fuse (CU15, CU15-M)
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
See table
±5%
±1%
No minimum load required
1.5 s max
14 ms max
16 ms typical at full load and 115 VAC
0.6%
0.5% max
1.0% max 10% load to full load
4% max deviation, recovery to within 1%
within 500 µs for 25% load change
1% max pk-pk (see note 1)
130-150% of Vnom, recycle input to reset
Trip and restart (Hiccup mode)
0.05%/˚ C
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
Environmental
Operating Temperature • CU10/15: 0 ˚ C to +65 ˚ C, derate from
full load at +45 ˚ C to no load at +65 ˚ C
CU15-M: 0 ˚ C to +70 ˚ C, derate from
full load at +50 ˚ C to 50% load at +70 ˚ C
Cooling
• Convection-cooled
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -20 ˚ C to +85 ˚ C
Operating Altitude
• 3000 m
Vibration
• 10 Hz to 500 Hz, 2 g for 10 mins/cycle
60 min each cycle
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & interruptions
Safety Approvals
1
• See tables
• 3000 VAC Input to Output (CU10/15)
4000 VAC Input to Output (CU15-M)
• 100 kHz typical for 10 W models
67 kHz typical for 15 W models
• 2.43 W/in3 (CU10); 3.17 W/in3 (CU15)
• >500 kHrs per MIL-HDBK-217F
(15 & 24 V units >400 kHrs)
• CU15-M: EN55011 Level B conducted
Others: FCC20780 Level B,
EN55022 Class B conducted
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-3, level 3, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, 10 V, Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 1000 ms, 100% 5000 ms,
Perf Criteria A, B, B
• CU15-M: EN60601, UL2601-1, CSA22.2
No. 601.1 per cUL
Others: EN60950, UL1950, CSA22.2 No.
234 per cUL
Output Current
Output
Voltage(3)
Output
Power
8.25 W
3.3
5.0
9.0
12.0
15.0
24.0
10 W
VDC
VDC
VDC
VDC
VDC
VDC
10 W
3.3
5.0
9.0
12.0
15.0
24.0
15 W
Nominal
3.00 A
3.00 A
1.67 A
1.25 A
1.00 A
0.63 A
VDC
VDC
VDC
VDC
VDC
VDC
Notes
1. Measured at 20 MHz bandwidth. 3.3 V models are 50 mV maximum.
2. Peak load lasting