AC-DC
10-15 Watts CU10-15 Series
• • • • • • • Low Cost Small Size PCB Mount 15 Watt Medical Version Single Output 3.3-24 V Peak Load Capability
xppower.com
Non-standard Outputs Available
Specification
Input
Input Voltage Input Frequency Input Current • 85-264 VAC (120-370 VDC) • 47-63 Hz • 0.13 A rms at 230 VAC (CU10) 0.20 A rms at 230 VAC (CU15) Inrush Current • 20 A at 115 VAC, 40 A at 230 VAC, cold start 25 ºC Earth Leakage Current • Class 2 (no earth) Input Protection • 1A fuse (CU10) 2A fuse (CU15, CU15-M)
General
Efficiency Isolation Switching Frequency Power Density MTBF • See tables • 3000 VAC Input to Output (CU10/15) 4000 VAC Input to Output (CU15-M) • 100 kHz typical for 10 W models 67 kHz typical for 15 W models • 2.43 W/in3 (CU10); 3.17 W/in3 (CU15) • >500 kHrs per MIL-HDBK-217F (15 & 24 V units >400 kHrs)
Environmental
Operating Temperature • CU10/15: 0 ˚C to +65 ˚C, derate from full load at +45 ˚C to no load at +65 ˚C CU15-M: 0 ˚C to +70 ˚C, derate from full load at +50 ˚C to 50% load at +70 ˚C Cooling • Convection-cooled Operating Humidity • 95% RH, non-condensing Storage Temperature • -20 ˚C to +85 ˚C Operating Altitude • 3000 m Vibration • 10 Hz to 500 Hz, 2 g for 10 mins/cycle 60 min each cycle
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Drift Line Regulation Load Regulation Transient Response Ripple & Noise Overvoltage Protection Short Circuit Protection Temperature Coefficient • • • • • • • • • • • • • • • See table ±5% ±1% No minimum load required 1.5 s max 14 ms max 16 ms typical at full load and 115 VAC 0.6% 0.5% max 1.0% max 10% load to full load 4% max deviation, recovery to within 1% within 500 µs for 25% load change 1% max pk-pk (see note 1) 130-150% of Vnom, recycle input to reset Trip and restart (Hiccup mode) 0.05%/˚C
EMC & Safety
Emissions • CU15-M: EN55011 Level B conducted Others: FCC20780 Level B, EN55022 Class B conducted • EN61000-4-2, level 3, Perf Criteria A • EN61000-4-3, level 3, Perf Criteria A • EN61000-4-4, level 2, Perf Criteria A • EN61000-4-5, level 3, Perf Criteria A • EN61000-4-6, 10 V, Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 1000 ms, 100% 5000 ms, Perf Criteria A, B, B • CU15-M: EN60601, UL2601-1, CSA22.2 No. 601.1 per cUL Others: EN60950, UL1950, CSA22.2 No. 234 per cUL
ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & interruptions
Safety Approvals
1
AC-DC
Models and Ratings
Output Power 8.25 W Output Voltage(3) 3.3 5.0 9.0 12.0 15.0 24.0 VDC VDC VDC VDC VDC VDC Output Current Nominal 2.50 A 2.00 A 1.12 A 0.84 A 0.67 A 0.42 A Output Current Nominal 3.00 A 3.00 A 1.67 A 1.25 A 1.00 A 0.63 A Peak(2) 4.50 A 4.50 A 3.00 A 1.80 A 1.50 A 0.95 A Peak(2) 3.80 A 2.80 A 1.50 A 1.20 A 1.00 A 0.65 A Efficiency (typical) 65% 70% 72% 75% 75% 78% Efficiency (typical) 70% 73% 75% 80% 80% 82%
CU10-15
Model Number CU10-00 CU10-10 CU10-09 CU10-12 CU10-13 CU10-14 †^ †^ †^ †^ †^
10 W
Output Power 10 W
Output Voltage(3) 3.3 5.0 9.0 12.0 15.0 24.0 VDC VDC VDC VDC VDC VDC
Model Number(4) CU15-00 CU15-10 CU15-09 CU15-12 CU15-13 CU15-14 †^ †^ †^ †^ †^
15 W
Notes
1. Measured at 20 MHz bandwidth. 3.3 V models are 50 mV maximum. 2. Peak load lasting
很抱歉,暂时无法提供与“CU10-10”相匹配的价格&库存,您可以联系我们找货