DSA-DP20 Series
AC-DC Power Supplies
20 A Redundancy Module
xxx Series
• Ultra Slim Design
• 24 V Redundant Operation
• DIN Rail TS35 / 7.5 or 15 Installation
• Relay Contact Signal Output & Failure Alarm LED Indicator
• 3 Year Warranty
Dimensions:
DSA-DP20:
3.92 x 4.92 x 2.18” (99.8 x 125.2 x 55.5 mm)
Models & Ratings
Input Voltage Range
21-28 V
Input Current
20 A per input
Output Current
20 A
Model Number
DSA-DP20
Mechanical Details
1
2
4.929 (125.2)
DC1
DC2
DSA-DP20
www.xppower.com
Vout
+ -
-Vin
-
-
+Vin
2 1
2.185 (55.5)
3.929 (99.8)
1
www.xppower.com
Pin Connector
Conn Pin
1
2
3
Vin/
Vout
4
5
6
1
2
Alarm
3
4
Designation
+Vout
-Vout
-Vin
-Vin
Vin 2+
Vin 1+
DC1
DC1
DC2
DC2
DSA-DP20 Series
AC-DC Power Supplies
Input
Minimum
Input Voltage Range
Typical
21
Maximum
Units
28
VDC
20
A
Maximum
Units
30
VDC
Notes & Conditions
Number of Inputs
2 inputs
Input Current
Per input
Output
Characteristic
Minimum
Typical
Reverse Voltage
Output Current
20
A
Output Voltage Drop
0.5
VDC
LED Indicators
Notes & Conditions
A green LED per input indicates voltage present
Signals
Characteristic
Input Voltage Alarm
Minimum
Typical
Maximum
Units
Notes & Conditions
Relay contact per input to indicate voltage present. Contacts are closed if voltage is < 20V or > 30V (±5%)
Relay Contact Rating
30 / 1
VDC / A
General
Characteristic
Minimum
Typical
Maximum
500
Isolation Voltage
Isolation Resistance
Units
Notes & Conditions
VAC
Chassis to input
500
VDC
Chassis to output
500
VDC
Chassis to alarm contacts
100
MΩ
Chassis to terminals at 500 VDC, 25 °C & 70% RH
Environmental
Characteristic
Maximum
Units
Operating Temperature
-20
+70
°C
Storage Temperature
-40
+85
°C
Operating Humidity
10
95
%RH
Vibration
Minimum
Typical
Notes & Conditions
See derating curve in Application Notes
Non-condensing
10 ~ 500 Hz, 2 g 10min. / cycle, period for 60min. each along X, Y, Z axes; Certified IEC 60068-2-6
EMC: Emissions
Phenomenon
Standard
Test Level
Radiated
EN55022
Class B
Standard
Test Level
Criteria
Notes & Conditions
Criteria
Notes & Conditions
EMC: Immunity
Phenomenon
Immunity
EN61204-3
ESD Immunity
EN61000-4-2
2
A
Radiated Immunity
EN61000-4-3
3 V/m
A
EFT/Burst
EN61000-4-4
1
A
Surges
EN61000-4-5
1
A
Conducted
EN61000-4-6
3 Vm
A
Magnetic Fields
EN61000-4-8
1 A/m
A
www.xppower.com
2
DSA-DP20 Series
AC-DC Power Supplies
Application Notes
1+1 Redundancy
PSU
PSU
VinA
.
VinB
DSA-DP20
Vout
Load
N+1 Redundancy
PSU
PSU
VinA
PSU
VinB
PSU
VinA
VinB
DSA-DP20
Vout
PSU
.........
PSU
VinA
DSA-DP20
VinB
DSA-DP20
Vout
Vout
Load
Derating Curves
Block Diagram
P
Vout+
DC1
RELAY
1
60
Vin 1+
40
ALARM 2
DC2
Vin 2+
80
LOAD (%)
DC2
RELA Y
2
100
ALARM 1
DC1
-Vin/Vout
20
-20
0
10
20
30
40
50
60
70
AMBIENT TEMPERA TURE (°C)
www.xppower.com
12-Feb-15
很抱歉,暂时无法提供与“DSA-DP20”相匹配的价格&库存,您可以联系我们找货
免费人工找货