E Series
3W
DC-HVDC CONVERTER
CONVECTION
COOLED
The E Series is a broad line of small, component level high voltage converters in a PCB
mount package that provides up 3 Watts continuous output power for models up to 7kV (2
Watts for models >7kV). These HV converters feature low ripple and noise, and low EMI/
RFI by utilizing a quasi-sinewave oscillator, excellent filtering techniques and a fully enclosed
pot-core transformer. The output voltage is directly proportional to the input voltage and is
linear from approximately 0.7 volts to maximum input.
The galvanically isolated output allows for user selectable output polarity. Dual output
models with a center-tap pin provide both positive and negative outputs from one module.
Some models are provided with an external aluminum box for increased EMI/RFI shielding
and rugged mounting. Proven design techniques, classic topology and custom encapsulation
Typical Applications
formula come together to provide engineers with a clean, reliable, low cost, and easy to
integrate high voltage solution.
Features
• Mass Spectrometry
• Electrostatic Chucks
• Output Voltages from 100V to 12kV
• Electrophoresis
• Capacitor Charging
• Output Voltage Proportional to Input
• Particle Counter
• Low Turn-on Voltage 0.7VDC
• Ignition/Spark
• Input to Output Isolation
• Sustaining Ion Pumps
• Dual Output
Dimensions
• No Minimum Load
• 3 Year Warranty
2.50 x 1.5 x 0.85" (63.5 x 38.1 x 21.6mm)
Block Diagram
(+) In
3
1
+
(-) In
2
RECTIFIER &
MULTIPLIER
OSCILLATOR
Transformer
5
4
(+) Output
Center Tap (for Dual Output option)
(-) Output
E Series
DC-HVDC CONVERTER
Input
Characteristic
Minimum
Typical
Units
Notes & Conditions
See Models & Ratings table
12, 15
VDC
Input Current, Full Load
175
mA
Input Current, No Load
400
mA
Maximum
Units
Notes & Conditions
12000
VDC
See Models & Ratings table
30
mA
See Models & Ratings table
%
At Max Vout, Full Load
Input Voltage Range
0.7
Maximum
Output
Characteristic
Minimum
Typical
Output Voltage
Output Current
±5
Output Voltage Tolerance
Minimum Load
No minimum load required
Regulation
Unregulated, Output is proportional to Input. See Application Notes
Ripple and Noise
0.05
1.5
10
Response Time
%
See Models & Ratings table
msec
0 to Max Vout, Full Load
Maximum
Units
Notes & Conditions
Environmental
Characteristic
Minimum
Typical
Operating Temperature (case)
-10
+60
°C
Models E01 to E60
Operating Temperature (case)
-10
+50
°C
Models E70 to E121
-25
+90
°C
95
%RH
Non-condensing
Maximum
Units
Notes & Conditions
Isolation: Input to Output
3500
V