ECP225-A Series
AC-DC Power Supplies
XP Power
225 Watts
• Low 1”Profile
• High Power Density
• 3”by 5.0”Footprint
• 150 W Convection/ 225 W Force Cooled Ratings
• 5 V Standby and 12 V Fan Outputs
• Medical and ITE Approvals
• High Efficiency, up to 94%
• Less than 0.5 W No Load Input Power
The ECP225-A series is designed to minimize the no load power consumption and maximize
efficiency to facilitate equipment design to meet the latest environmental legislation. Approved for
medical and ITE applications, this range of single output AC/DC power supplies are packaged in an
ultra-low profile 1” height with a foot print of just 3.0” by 5.0”. The ECP225-A provides up to 225 W
force-cooled or 150 W convection-cooled leading to very high power densities of 15 W/in3 or 10
W/in3 respectively. A 5 V, 2 A standby output and a 12 V, 500 mA fan supply are included in the
design. The power supply contains two fuses and low leakage currents as required by medical
applications and is safety approved to operate in a 70 °C ambient. The low profile and safety
approvals covering ITE and medical standards along with conducted emissions to EN55011/22 level
B allow the versatile ECP225-A series to be used in a vast range of applications.
Dimensions:
ECP225-A:
5.00 x 3.00 x 1.00” (127.0 x 76.2 x 25.4 mm)
Models & Ratings
Output
Voltage
Output Current
Convection-cooled
Standby Voltage
Forced-cooled(1)
Convection-cooled
Forced-cooled
Model Number(4)
12.0 V
12.50 A
18.75 A
5 V/1.0 A
5 V/2.0 A
12 V/0.5 A
92%
ECP225PS12-A
15.0 V
10.00 A
15.00 A
5 V/1.0 A
5 V/2.0 A
12 V/0.5 A
92%
ECP225PS15-A
24.0 V
6.25 A
9.38 A
5 V/1.0 A
5 V/2.0 A
12 V/0.5 A
92%
ECP225PS24-A
28.0 V
5.36 A
8.04 A
5 V/1.0 A
5 V/2.0 A
12 V/0.5 A
92%
ECP225PS28-A
48.0 V
3.10 A
4.69 A
5 V/1.0 A
5 V/2.0 A
12 V/0.5 A
92%
ECP225PS48-A
Notes
1. Requires 10 CFM.
2. Measured with 20 MHz bandwidth and 10 μF electrolytic capacitor in parallel with 0.1 μF ceramic capacitor
3. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 225 W load and 230 VAC input.
4. Typical voltage, actual regulated voltage will be in range of 10.5 V to 11.1 V
5. Regulation of the fan output requires a minimum load of 10 W on the main output.
1
Fan Output(4,5) Efficiency(3)
www.xppower.com
ECP225-A Series
AC-DC Power Supplies
XP Power
Input
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage - Operating
85
115/230
264
VAC
Derate output from 100% at 90 VAC to 90% at 85 VAC
Input Frequency
47
50/60
63
Hz
Power Factor
>0.9
Input Current - Full Load
Inrush Current
Earth Leakage Current
2.2/1.1
A
115/230 VAC
120
A
80/140
No load Input Power
Input Protection
Agency approval, 47-63 Hz
230 VAC, 100% load EN61000-3-2 class A
EN6100-2-2 class C > 145W
230
μA
230 VAC cold start, 25 ºC
115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max)
0.5
W
When main output is Inhibited
F3.15 A/250 V Internal fuse fitted in line and neutral.
Output - Main Output
Characteristic
Minimum
Output Voltage - V1
Typical
12
Initial Set Accuracy
Maximum
Units
Notes & Conditions
48
VDC
See Models and Ratings table
±1
%
50% load, 115/230 VAC
V1 only via potentiometer. See Mech. Details, Vfan will track
Output Voltage Adjustment-V1
5
%
Minimum Load
0
A
Start Up Delay
2
Hold Up Time
10
20/13
s
ms
115/230 VAC full load.
Min at full load, 115 VAC. Typical at 150W/ 225W
Drift
±0.02
%
After 20 min warm up
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±0.5
%
0-100% load.
Transient Response
4
%
Recovery within 1% in less than 500 μs
for a 50-75% and 75-50% load step
Over/Undershoot
7
%
Full load
Ripple & Noise
1
% pk-pk
Overvoltage Protection
110
140
%
Overload Protection
110
170
% I nom
0.02
%/˚C
Short Circuit Protection
Vnom, recycle input to reset
Trip & Restart
Temperature Coefficient
Overtemperature Protection
Remote On/Off
20 MHz bandwidth and 10 μF electrolytic capacitator in
parallel with 0.1 μF ceramic capacitator.
°C
Measured internally, Auto Resetting
Connect pin 3 of CN2 to pin 1 to turn main output off. Connect to pin 2 or leave open to turn main output on.
Output - 5 V Standby Output
Characteristic
Minimum
Output Voltage
Typical
Initial Set Accuracy
Minimum Load
Units
Notes & Conditions
VDC
±1
0
%
50% load, 115/230 VAC
A
Start Up Delay
Hold Up Time
Maximum
5.0
0.5
300
s
115/230 VAC full load.
ms
Min at full load, 115 VAC.
Drift
±0.02
%
After 20 min warm up
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±0.5
%
0-100% load.
Transient Response
4
%
Recovery within 1% in less than 500 μs
for a 50-75% and 75-50% load step
Over/Undershoot
5
%
Full load
Ripple & Noise
1
% pk-pk
4.0
A
0.02
%/˚C
Overload Protection
3.0
Short Circuit Protection
Temperature Coefficient
Overtemperature Protection
20 MHz bandwidth and 10 μF electrolytic capacitator in
parallel with 0.1 μF ceramic capacitator
Trip & Restart
°C
www.xppower.com
Measured internally, Auto Resetting
2
ECP225-A Series
AC-DC Power Supplies
XP Power
General
Characteristic
Minimum
Typical
Efficiency
Maximum
Units
94
Isolation: Input to Output
Input to Ground
Output to Ground
Switching Frequency
%
Notes & Conditions
230 VAC Full load (see fig. 1 and 2)
4000
VAC
2 MOPP
1500
VAC
1 MOPP
1500
VAC
1 MOPP
70
130
kHz
PFC
50
80
kHz
Main converters
15/10
W/in3
Forced/convection-cooled
300
kHrs
MIL-HDBK-217F, Notice 2 +25 °C GB
0.51(230)
lb(g)
Power Density
Mean Time Between Failure
Weight
Efficiency Vs Load
Figure 1
ECP225PS12-A
12 V at 215 W
5 V at 10 W
100%
Efficiency
95%
90%
85Vac input
90Vac input
85%
115Vac input
230Vac input
80%
264Vac input
75%
70%
10
20
30
40
50
60
70
80
90
100
Load (%)
Figure 2
ECP225PS24-A
24 V at 215 W
5 V at 10 W
100%
95%
Efficiency
90%
85Vac input
90Vac input
85%
115Vac input
230Vac input
80%
264Vac input
75%
70%
10
20
30
40
50
60
70
Load (%)
3
www.xppower.com
80
90
100
ECP225-A Series
AC-DC Power Supplies
XP Power
Environmental
Characteristic
Maximum
Units
Operating Temperature
Minimum
-20
Typical
+70
°C
Storage Temperature
-40
+85
°C
Cooling
10
CFM
Forced-cooled > 150W
Humidity
5
95
%RH
Non-condensing
5000
m
Operating Altitude
Notes & Conditions
See derating curve, fig.3
Shock
±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27
Vibration
Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
Temperature Derating Curve
50
0
-40
High Line Only
100
Output Load (%)
Figure 3
-30
0
+50
+70
Ambient Temperature (ºC)
EMC: Emissions
Standard
Test Level
Conducted
Phenomenon
EN55011/32
Class B
Radiated
EN55011/32
Class A
Class B with King Core
K5B RC 13*23*7 on input cable and
K5B RC 25*12*15 on output cable.
EN61000-3-2
Class A
Meet Class C for loads above 145W
Harmonic Current
Voltage Functions
Criteria
Notes & Conditions
EN61000-3-3
EMC: Immunity
Phenomenon
Medical Device EMC
Low Voltage PSU EMC
Standard
Test Level
Criteria
IEC60601-1-2
Ed.4.0 : 2014
as below
EN61204-3
High severity level
as below
ESD
EN61000-4-2
4
A
Radiated
EN61000-4-3
3
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
3
A
Magnetic Fields
EN61000-4-8
4
A
Dip >95% (0 VAC), 8.3 ms
EN55035 (100 VAC)
EN55035 (240 VAC)
Dips and Interruptions
EN60601-1-2 (100 VAC)
EN60601-1-2 (240 VAC)
±8kV contact, ±15kV air
A
Dip 30% (70 VAC), 416 ms
A
Dip >95% (0 VAC), 4160 ms
Dip >95% (0 VAC), 10.0 ms
B
A
Dip 30% (168 VAC), 500 ms
A
Dip >95% (0 VAC), 5000 ms
B
Dip 100% (0 VAC), 10.0 ms
A
Dip 100% (0 VAC), 20 ms
A
Dip 60% (40 VAC), 100 ms
A
Dip 30% (40 VAC), 500 ms
A
Dip 100% (0 VAC), 5000 ms
B
Dip 100% (0 VAC), 10.0 ms
A
Dip 100% (0 VAC), 20 ms
A
Dip 60% (96 VAC), 100 ms
A
Dip 30% ( 168 VAC), 500 ms
A
Dip 100% (0 VAC), 5000 ms
B
www.xppower.com
Notes & Conditions
Derate Output Power to 45W
4
ECP225-A Series
AC-DC Power Supplies
XP Power
Safety Approvals
Safety Agency
CB Report
UL
EN
Safety Standard
Notes & Conditions
IEC62368-1:2014
Audio/Video, Information and Communication Technology Equipment
IEC60601-1 Ed 3 Including Risk Management
Medical
UL62368-1, CAN/CSA C22.2 No.62368-1-14
Audio/Video, Information and Communication Technology Equipment
ANSI/AAMI ES60601-1: 2005 & CSA C22.2 No.6061-1:08
Medical
EN62368-1:2014/A11:2017
Information Technology
EN60601-1:2006
Audio/Video, Information and Communication Technology Equipment
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Isolation
Safety Standard
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Primary to Earth
1 x MOPP (Means of Patient Protection)
Secondary to Earth
1 x MOPP (Means of Patient Protection)
Notes & Conditions
IEC60601-1 Ed 3
Mechanical Details
5.00 (127.0)
4.75 (120.6)
0.25 (6.35) Faston ground tab
VR
1
2.75
(69.9)
Q1
L1
CN2
3.00
(76.2)
11
3
CN1
1
C2
TR1
C52
2
1
CN3
Mounting Screw
Holes 4 Places
0.134 (Ø3.4 ±0.3)
0.06
(1.60)
CN2 - Output Connector
0.11 0.83
(2.80) (21.0)
CN1 - Input Connector
CN3 - Fan Connector
Pin 1
+5 V Standby
Pin 1
Neutral
Pin 1
Fan -
Pin 2
-Vout
Pin 2
Not Fitted
Pin 2
Fan +
Pin 3
Remote On/Off
Pin 3
Line
Pin 4
+Vout
Pin 5
+Vout
Pin 6
+Vout
Pin 7
+Vout
Pin 8
-Vout
Pin 9
-Vout
Pin 10
-Vout
Pin 11
-Vout
Mates with Molex housing
22-01-1022 and 2759 crimp terminals
Mates with JST housing
VHR-3N and JST Series
SVH-21T-P1.1 crimp terminals
Mounting holes marked with
must be connected to safety earth
Mates with JST housing
VHR-11N and JST Series
SVH-21T-P1.1 crimp terminals
Notes
1. All dimensions shown in inches (mm).
Tolerance: ±0.02 (0.5)
5
2. Weight: 0.51 lbs (230 g) approx.
www.xppower.com
ECP225-A Series
AC-DC Power Supplies
XP Power
Thermal Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below
must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component
(out of direct air flow). See Mechanical Details for component locations.
Temperature Measurements (At Maximum Ambient)
Component
Max Temperature °C
TR1 Coil
110°C
L1 Coil
120°C
Q1 Body
120°C
C2
105°C
C52
105°C
Service Life
The estimated service life of the ECP225-A is determined by the cooling arrangements and load conditions experienced in the end
application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of
a key capacitor with in the product when installed by the end application,
The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this
temperature.
Estimated Service Life vs Component Temperature
Figure 4
80000
70000
60000
Lifetime (Hrs)
50000
40000
C52
C2
85
75
30000
20000
10000
0
105
95
65
55
45
C2 + C52 Temperature (ºC)
www.xppower.com
20 July 2022