0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EPL150PS12

EPL150PS12

  • 厂商:

    XPPOWER

  • 封装:

  • 描述:

    AC-DC OPEN FRAME PSU, 150W IND+M

  • 数据手册
  • 价格&库存
EPL150PS12 数据手册
EPL150 Series AC-DC Power Supplies 150 Watts • 100 W Convection/150 W Forced-cooled Ratings • 2” by 4” Footprint • Low 0.99” Profile • Class I & Class II Operation • 12 V Fan Output • High Efficiency, up to 95% • ITE & Medical (BF) Approvals • High Power Density • Less than 0.5 W No Load Input Power • 3 Year Warranty Dimensions: The EPL150 series maximises efficiency across the load range and minimises no load power consumption minimising heat dissipation, reducing running costs and enabling compliance with the latest environmental goals and legislation. Fully approved as Class I & Class II for ITE, Industrial and Medical applications the EPL150 provides up to 100 W when convection cooled and up to 150 W when force cooled at just 10 CFM. A 12 V 0.5 A fan supply is included to support force cooled applications. The small footprint, low profile, low noise and comprehensive safety agency approvals allow this versatile product to be used in a wide range of ITE and industrial applications. EPL150: 4.00 x 2.00 x 0.99” (101.6 x 50.8 x 25.1 mm) Models & Ratings Output Current Convection-cooled Forced-cooled(1) Output Power Output Voltage 150 W 12.0 V 8.33 A 150 W 15.0 V 6.67 A 150 W 18.0 V 5.56 A 150 W 24.0 V 150 W 150 W 150 W Fan Output Efficiency(2) Model Number 12.50 A 12 V/0.5 A 93% EPL150PS12 10.00 A 12 V/0.5 A 93% EPL150PS15 8.33 A 12 V/0.5 A 93% EPL150PS18 4.17 A 6.25 A 12 V/0.5 A 93% EPL150PS24 28.0 V 3.50 A 5.40 A 12 V/0.5 A 93% EPL150PS28 36.0 V 2.78 A 4.17 A 12 V/0.5 A 93% EPL150PS36 48.0 V 2.08 A 3.10 A 12 V/0.5 A 93% EPL150PS48 Notes 1. Requires 10 CFM. 2. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 150 W load and 230 VAC input. Summary Characteristic Input Range Minimum 80 Typical Maximum 115/230 264 No Load Input Power 0.5 Efficiency Operating Temperature 1 95 -20 +70 Units Notes & Conditions VAC Derate load from 100% at 90 VAC to 90% at 85 VAC and 85% at 80 VAC W % 230 VAC (see fig.1 & 2) °C See derating curve (fig.3) EMC Conducted: EN55011/32, Class B, Radiated: EN55011/32, Class A (Class B with external core, see EMC Emissions for details) Safety Approvals CB/EN/UL/CSA for ITE and Medical www.xppower.com EPL150 Series AC-DC Power Supplies Input Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 80 115/230 264 VAC Derate output from 100% at 90 VAC to 90% at 85 VAC and 85% at 80 VAC Input Frequency 47 50/60 63 Hz Characteristic Power Factor >0.9 Input Current - Full Load Inrush Current Earth Leakage Current A 115/230 VAC 120 A 230 VAC cold start, 25 ºC 115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max) 80/140 No load Input Power Input Protection 230 VAC, 100% load EN61000-3-2 class A 2.2/1.1 230 µA 0.5 W F3.15 A/250 V Internal fuse fitted in line and neutral. Output - Main Output Characteristic Output Voltage - V1 Minimum Typical 12 Initial Set Accuracy Maximum Units Notes & Conditions 48 VDC See Models and Ratings table ±1 % 50% load, 115/230 VAC % None Output Voltage Adjustment-V1 Minimum Load 0 A Start Up Delay Hold Up Time 2 10 20/13 s ms 115/230 VAC full load. Min at full load, 115 VAC. Typical at 100W/150W Drift ±0.02 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC Load Regulation ±0.5 % 0-100% load. Transient Response 4 % Recovery within 1% in less than 500 µs for a 50-75% and 75-50% load step Over/Undershoot 7 % Full load Ripple & Noise 1 % pk-pk Overvoltage Protection 110 140 % Overload Protection 110 170 % I nom 0.02 %/˚C Short Circuit Protection Temperature Coefficient Overtemperature Protection 20 MHz bandwidth and 10 µF electrolytic capacitator in parallel with 0.1 µF ceramic capacitator. Vnom, recycle input to reset Trip & Restart °C www.xppower.com Measured internally, Auto Resetting 2 EPL150 Series AC-DC Power Supplies General Characteristic Minimum Typical Maximum Units 94 Efficiency % VAC 4000 Isolation: Input to Output Input to Ground Output to Ground 230 VAC (see fig. 1 & 2) 2 MOPP 1500 VAC 1 MOPP 1500 VAC 1 MOPP Patient Leakage Switching Frequency Notes & Conditions 50 µA At 264 VAC, 50 Hz 40 130 kHz PFC 50 95 kHz 18.9/12.6 W/in3 Forced/convection-cooled 300 kHrs MIL-HDBK-217F, Notice 2 +25 °C GB 0.43(195) lb(g) Power Density Mean Time Between Failure Weight Main converter Efficiency Vs Load Figure 1 EPL150PS24 100 W 100% 95% Efficiency 90% 85% 115Vac 80% 230Vac 75% 70% 65% 60% 10 20 30 40 50 60 70 80 90 100 Load (%) Figure 2 EPL150PS24 150 W 100% 95% Efficiency 90% 85% 115Vac 80% 230Vac 75% 70% 65% 60% 10 20 30 40 50 60 70 Load (%) 3 www.xppower.com 80 90 100 EPL150 Series AC-DC Power Supplies Environmental Characteristic Maximum Units Operating Temperature Minimum -20 Typical +70 °C Storage Temperature -40 +85 Cooling 10 Humidity 5 Operating Altitude Notes & Conditions See derating curve, fig.3 °C CFM Forced-cooled > 150W 95 %RH Non-condensing 5000 m Shock ±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27 Vibration Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 Temperature Derating Curve 100 Output Load (%) Figure 3 50 0 -20 0 +50 +70 Ambient Temperature (ºC) EMC: Emissions Standard Test Level Conducted Phenomenon EN55011/22 Class B Radiated EN55011/22 Class A EN61000-3-2 Class A Harmonic Current Voltage Functions Criteria Notes & Conditions Class B with King Core K5B RC 13 x 23 x 7 on input cable and K5B T 25 x 12 x 5 on output cable. EN61000-3-3 EMC: Immunity Phenomenon Medical Device EMC Low Voltage PSU EMC Standard Test Level Criteria IEC60601-1-2 Ed.4.0 : 2014 as below as below EN61204-3 High severity level ESD EN61000-4-2 4 A Radiated EN61000-4-3 3 A A EFT EN61000-4-4 3 Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Magnetic Fields EN61000-4-8 4 A Dip >95% (0 VAC), 8.3 ms EN55024 (100 VAC) EN55024 (240 VAC) Dips and Interruptions EN60601-1-2 (100 VAC) A Dip >95% (0 VAC), 4160 ms Dip >95% (0 VAC), 10.0 ms B A Dip >95% (0 VAC), 5000 ms B Dip 100% (0 VAC), 20 ms B Dip 30% (70 VAC), 500 ms A B A Dip 100% (0 VAC), 5000 ms B Dip 100% (0 VAC), 20 ms B Dip 100% (0 VAC), 10.0 ms EN60601-1-2 (240 VAC) A Dip 30% (168 VAC), 500 ms Dip 60% (40 VAC), 100 ms Dip 60% (96 VAC), 100 ms Dip 30% ( 168 VAC), 500 ms Dip 100% (0 VAC), 5000 ms www.xppower.com ±8kV contact, ±15kV air A Dip 30% (70 VAC), 416 ms Dip 100% (0 VAC), 10.0 ms Notes & Conditions A A A B 4 EPL150 Series AC-DC Power Supplies Safety Approvals Safety Agency Safety Standard Notes & Conditions CB Report IEC60950-1-1, IEC62368-1 Information Technology UL UL60950-1, UL62368-1 Information Technology TUV EN62368-1 Information Technology CB Report IEC60601-1 Medical UL ES60601-1 Medical EN EN60601-1 Medical Isolation Safety Standard Notes & Conditions Primary to Secondary 2 x MOPP (Means of Patient Protection) Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Suitable for use as BF applied part application Mechanical Details 0.06 (1.6) 0.83 (21.0) 0.10 (2.5) 4.0 (101.6) 3.75 (95.3) L4 1.75 (44.5) 2.00 (50.8) CN2 TR1 CN1 C2 C52 C13 Mounting screw holes (in 4 positions) CN1 Pin 1 AC-L Pin 2 Pin 3 AC-N Mates with JST VHR-3N housing and SVH-21T-P1.1 crimps CN3 0.13 (ø3.2) CN3 CN2 Pin 1 +Vo Pin 1 Fan - Pin 2 +Vo Pin 2 Fan + Pin 3 +Vo Pin 4 Com Pin 5 Com Pin 6 Com Mates with Molex 22-01-1022 housing and 2759 crimps Mates with JST VHR-6N housing and SVH-21T-P1.1 crimps Mounting holes marked with must be connected to safety earth in Class I application or connected together in Class II application. Notes 1. All dimensions shown in inches (mm). Tolerance: ±0.02 (0.5) 5 2. Weight: XXX lbs (XXX g) approx. www.xppower.com EPL150 Series AC-DC Power Supplies Thermal Considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using thermocouples placed on the hottest part of the component (out of direct air flow). See Mechanical Details for component locations. Temperature Measurements (At Maximum Ambient) Max Temperature °C Component TR1 Coil 120°C L4 Coil 120°C C13 105°C C52 105°C C2 105°C Service Life The estimated service life of the EPL150 is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of key capacitors with in the product when installed by the end application, The graph below expresses the estimated lifetime based on the temperature of these key components based on the average temperature over the lifetime of the equipment. Estimated Service Life vs Component Temperature Figure 4 160000 150000 140000 130000 120000 Lifetime (Hrs) 110000 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 0 105 95 85 75 C2 C52 65 55 C13 C2, C13 & C52 Temperature (ºC) www.xppower.com 29 Nov 17
EPL150PS12 价格&库存

很抱歉,暂时无法提供与“EPL150PS12”相匹配的价格&库存,您可以联系我们找货

免费人工找货
EPL150PS12
  •  国内价格
  • 1+495.07382
  • 10+485.17026
  • 50+475.46456

库存:7

EPL150PS12
    •  国内价格
    • 1+852.91800

    库存:4