G Series
1.5W
DC-HVDC CONVERTER
CONVECTION
COOLED
The G Series is a line of miniature high voltage converters that provide up to 6kV output,
positive or negative, in a compact PCB mount package. The isolated output is directly
proportional to the input, and is linear from approximately 0.7 volts in. Excellent filtering
techniques and a low noise quasi-sinewave oscillator provide clean, reliable DC to HV DC
conversion with low ripple and low EMI/RFI.
The isolated output allows for user selectable output polarity. When the optional center-tap
pin is grounded, the unit provides both positive and negative outputs from one compact,
low cost module. The pin pattern used on this model has become an industry standard for
high voltage modules. The G Series units are component level converters that are easy to
integrate, low cost, and come with decades of field proven reliability.
Typical Applications
Features
• Mass Spectrometry
• Electrostatic Chucks
• Output Voltages from 100V to 6kV
• Electrophoresis
• Output Voltage Proportional to Input
• Capacitor Charging
• Particle Counter
• Low Turn-on Voltage 0.7VDC
• Ignition/Spark
• Input to Output Isolation
• Sustaining Ion Pumps
• Dual Output Models
• No Minimum Load
Dimensions
• 3 Year Warranty
1.50 x 1.50 x 0.63" (38.1 x 38.1 x 16.0mm)
Block Diagram
(+) In
3
1
+
(-) In
2
RECTIFIER &
MULTIPLIER
OSCILLATOR
Transformer
5
4
(+) Output
Center Tap (for Dual Output option)
(-) Output
G Series
DC-HVDC CONVERTER
Input
Characteristic
Minimum
Input Voltage
0.7
Typical
Maximum
Units
Notes & Conditions
12
VDC
Input Current, No Load
175
mA
See Models and Ratings Table.
Input Current, Full Load
400
mA
See Models and Ratings Table.
Maximum
Units
Notes & Conditions
6000
VDC
See Models & Ratings table
15
mA
See Models & Ratings table
%
At Max Vout, Full Load
Output
Characteristic
Minimum
Typical
Output Voltage
Output Current
±3
Output Voltage Tolerance
Minimum Load
No minimum load required
Regulation
Unregulated, Output is proportional to Input. Unloaded output voltage is typically 10% higher than unloaded.
Ripple and Noise
0.1
2.0
15
Response Time
%
See Models & Ratings table
msec
0 to Max Vout, Full Load [G01 to G60]
Maximum
Units
Notes & Conditions
Environmental
Characteristic
Minimum
Typical
Operating Temperature
-10
+60
°C
Storage Temperature
-25
+90
°C
Case temperature
95
%RH
Non-condensing
Maximum
Units
Notes & Conditions
3500
V
190
kHz
Natural convection
Cooling
Humidity
General
Characteristic
Minimum
Isolation: Input to Output
Switching Frequency
Construction
Mean Time Between Failure
60
Typical
很抱歉,暂时无法提供与“G60CT”相匹配的价格&库存,您可以联系我们找货