0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GCS250PS24

GCS250PS24

  • 厂商:

    XPPOWER

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 24V 250W

  • 数据手册
  • 价格&库存
GCS250PS24 数据手册
GCS Series AC-DC Power Supplies XP Power 150/180/250/350 Watts • Convection/Forced-cooled Ratings • Universal 85 - 264 VAC Input • IT & Medical Safety Approvals (Class I & II) • < 0.5 W Standby Power (150 & 180 Models) • -40° C to +70° C Operation • Remote On/Off • Class B Emissions • 3 Year Warranty The GCS Series has been designed to minimise the no load power consumption and maximise efficiency in order to facilitate equipment design to the latest environmental legislation. Approved for Class I and Class II applications, this range of single output AC-DC power supplies are packaged in an industry standard 3.0" x 5.0" x 1.42" package and achieves EN55011/32 Level B emissions compliance whilst maintaining very low earth leakage currents, making them suitable for a wide range of 1U and other industrial, IT and medical applications. Dimensions: GCS150/GCS180/GCS250/GCS350: 5.00 x 3.00 x 1.42” (127.0 x 76.2 x 36.3 mm) (-C): 5.50 x 3.48 x 1.70” (139.7 x 88.5 x 43.2 mm) (-TF): 5.50 x 3.48 x 2.20” (139.7 x 88.5 x 57.8 mm) (-EF): 6.35 x 3.48 x 1.70” (161.3 x 88.5 x 43.2 mm) (350-EF): 6.00 x 3.50 x 1.75” (152.4 x 88.9 x 44.4 mm) The series has single output versions from 12 V to 56 VDC, dual-fusing for compliance with IEC60601-1 and feature minimal excess heat generation as efficiencies reach 94%. They will deliver up to 350 W of power over an operating range of -40 °C and up to +70 °C and are available with a number of cover options. Models & Ratings Output Voltage V1 12.0 VDC 15.0 VDC 24.0 VDC 28.0 VDC 48.0 VDC 12.0 VDC 15.0 VDC 24.0 VDC 28.0 VDC 48.0 VDC 12.0 VDC 15.0 VDC 24.0 VDC 28.0 VDC 48.0 VDC 56.0 VDC 12.0 VDC 15.0 VDC 24.0 VDC 28.0 VDC 48.0 VDC 56.0 VDC Output Current V1 Convection-cooled(6,7) 9.2 A 7.3 A 4.6 A 3.9 A 2.3 A 12.5 A 10.0 A 6.3 A 5.4 A 3.1 A 15.0 A 12.0 A 7.5 A 6.4 A 3.7 A 3.2 A 16.7 A 13.3 A 8.3 A 7.1 A 4.2 A 3.6 A Forced-cooled(8) 12.5 10.0 6.3 5.4 3.2 15.0 12.0 7.5 6.4 3.7 18.8 15.0 10.4 8.9 5.2 4.5 29.2 23.4 14.6 12.5 7.3 6.25 A A A A A A A A A A A A A A A A A A A A A A Output Voltage (Vfan) & Current 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A 12.0 VDC/0.6 A Max Output Power 157 W 157 W 157 W 157 W 157 W 187 W 187 W 187 W 187 W 187 W 232 W 232 W 257 W 257 W 257 W 257 W 350 W 350 W 350 W 350 W 350 W 350 W Model Number (1,2,3,4,5) GCS150PS12 GCS150PS15 GCS150PS24 GCS150PS28 GCS150PS48 GCS180PS12 GCS180PS15 GCS180PS24 GCS180PS28 GCS180PS48 GCS250PS12 GCS250PS15 GCS250PS24 GCS250PS28 GCS250PS48 GCS250PS56 GCS350PS12(9) GCS350PS15(9) GCS350PS24(10) GCS350PS28(10) GCS350PS48(10) GCS350PS56(10) Notes 1. Add suffix -C for convection-cooled cover, e.g. GCS150PS12-C. 2. Cover kits available. Order part no.: GCS150/180 CVR KIT 3. Add suffix -EF for fan-cooled cover with end fan e.g. GCS150PS12-EF, add suffix -TF for fan-cooled cover with top fan, e.g. GCS150PS12-TF. Note: Vfan output no longer available. 4. Add suffix -R for remote on/off, e.g. GCS150PS12-R, GCS150PS12-RC with convection cover or GCS150PS12-REF/GCS150PS12-RTF with fan covers, (remote on/off is standard on GCS350 models). 1 5. GCS250PS12-C & GCS250PS15-C models derate 20% when convection cooled. 6. GCS350 convection rating quoted at 40 °C, others at 50 °C, see thermal derating curve. 7. GCS350-C models derate 15% when convection-cooled at 40 °C. 8. 7 CFM required to meet stated current for GCS150/180/250 and 15 CFM for GCS350. 9. Add suffix ‘-J’ for optional dual row molex connector. See GCS350 model mechanics for details. 10. Add suffix ‘-S’ for optional screw terminals. See GCS350 mechanics for details. www.xppower.com GCS Series AC-DC Power Supplies XP Power Input Characteristic Input Voltage - Operating Input Frequency Power Factor Minimum 85 47 Typical 115/230 50/60 >0.9 1.5/0.7 1.8/0.8 2.2/1.1 2.4/1.2 3.6/1.8 80 Input Current - Full Load Inrush Current Maximum 264 63 0.5 2.3 5 3 1 3 4 60/120 200 95/185 250 95/185 250 95/185 250 GCS150/180: F3.15 A/250 V internal fuse in both No Load Input Power Earth Leakage Current Input Protection Units VAC Hz Notes & Conditions Derate output power 4 V to switch on (see fig. 6) Inhibit Remote On/Off (-R models) (Standard on GCS350 models) With the inhibit lo (pin 4) pulled low as detailed above, connecting inhibit hi (pin 5) to inhibit lo (pin 4) will enable V1 & V fan output. (see fig. 7) Enable Remote On/Off (Inhibit) Remote On/Off (Enable) Figure 6 Figure 7 POWER SUPPLY POWER SUPPLY Inhibit Hi Pin 5 Inhibit Lo Pin 4 Inhibit Lo Pin 4 0V 0V Signals Connector Signals Connector Environmental Characteristic Operating Temperature Storage Temperature Minimum -40 -40 Typical Maximum +70 +85 7 Cooling Humidity Operating Altitude Units °C °C Notes & Conditions See derating curve, fig. 8 Forced Cooled >110 W GCS150 Forced Cooled >150 W GCS180 Forced Cooled >180 W GCS250 GCS350 Non-condensing CFM 15 5 95 5000 %RH m Shock ±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/-0.5msec), half sine. Conforms to EN60068-2-27 & EN60068-2-47 Vibration Single axis 10 - 500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 Thermal Derating Curve 350 300 300 200 175 170 130 87 250 Open Frame Output Load (W) 225 Some specification parameters may not be met Output Load (W) 50 350 250 Some specification parameters may not be met Output Load (%) 100 Figure 10 - GCS350 Forced cooled ratings With Cover 5 -20 0 50 Ambient Temperature (ºC) 70 175 150 100 87 Forced Cooled 50 65 0 -40 225 200 Some specification parameters may not be met Figure 9 - GCS350 Convection cooled ratings Figure 8 - GCS150, 180, 250 0 -40 -30 -20 -10 0 10 20 30 40 Ambient Temperature (ºC) 50 www.xppower.com 60 70 0 -40 -30 -20 -10 0 10 20 30 40 Ambient Temperature (ºC) 50 60 70 GCS Series AC-DC Power Supplies XP Power EMC: Emissions Phenomenon Conducted Standard Test Level EN55011/32 Class B Criteria Notes & Conditions Class B Radiated Harmonic Fluctuations GCS150 Class A GCS180/GCS250/GCS350 Class B GCS180 & GCS250 with 3 turns of output cable through added ferrite core. (Manufacturer: Fair - Rite Products Corp, Part No: 2643800502) EN55011/32 EN61000-3-3 EMC: Immunity Phenomenon Low Voltage PSU EMC Harmonic Current Standard Test Level Criteria EN61204-3 High severity level Class A as below EN61000-3-2 Notes & Conditions All models > 50 W GCS150 > 50 W GCS180 Class C > 80 W GCS250 >125 W GCS350 Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A EN55035 (100 VAC) EN55035 (240 VAC) Dip >95% (0 VAC), 8.3ms A Dip 30% (70 VAC), 416ms B Dip >95% (0 VAC), 4160ms B Dip >95% (0 VAC), 10.0ms A Dip 30% (168 VAC), 500ms B Dip >95% (0 VAC), 5000ms B Dip >95% (0 VAC), 10.0ms A Derate Output Power to 85 W (GCS150) Dips and Interruptions EN60601-1-2 (100 VAC) Dip 60% (40 VAC), 100ms A Dip 30% (70 VAC), 500ms A Dip >95% (0 VAC), 5000ms B Dip >95% (0 VAC), 10.0ms A Dip 60% (96 VAC), 100ms A Derate Output Power to 90 W (GCS180) Derate Output Power to 120 W (GCS250) Derate Output Power to 150 W (GCS350) EN60601-1-2 (240 VAC) Dip 30% (168 VAC), 500ms A Dip >95% (0 VAC), 5000ms B Safety Approvals Safety Agency CB Report UL EN Safety Standard Notes & Conditions IEC60950-1:2005 Ed 2 / IEC62368-1:2014 Information Technology IEC60601-1 Ed 3 Including Risk Management Medical UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14, Information Technology ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08 Medical EN62368-1:2014/A11:2017 Information Technology EN60601-1/A12:2006 Medical CE LVD & RoHS Equipment Protection Class Class I & Class II See safety agency conditions of acceptibility for details Means of Protection Category Primary to Secondary 2 x MOPP (Means of Patient Protection) Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) IEC60601-1 Ed 3 www.xppower.com 6 GCS Series AC-DC Power Supplies XP Power Mechanical Details GCS150 Note: Mounting points A should be connected together for optimum EMI performance 5.0 (127.0) 0.225 (5.72) 4.55 (115.57) 1.43 (36.3) 0.20 (5.1) T1 Q3 C45 A 3.00 (76.2) 2.15 (54.6) AIRFLOW 2.40 (61.0) C23 2.55 (64.77) C6 Q1 C28 L3 A A 0.61 (15.6) 1.18 (29.8) 0.225 (5.72) 0.14 (3.5) 0.20 (5.1) 0.25 Faston Ground Tab 0.15 (3.8) SMD Component Height 0.18 (4.6) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom GCS180 Note: Mounting points A should be connected together for optimum EMI performance 5.0 (127.0) 0.225 (5.72) 4.55 (115.57) 1.43 (36.3) 0.20 (5.1) T1 Q3 C45 A 3.00 (76.2) 2.15 (54.6) AIRFLOW 2.40 (61.0) C23 2.55 (64.77) Q1 C28 C6 A A 0.61 (15.6) 1.18 (29.8) 0.225 (5.72) 0.14 (3.5) 0.20 (5.1) 0.25 Faston Ground Tab Pin 1 2 Function Line Neutral 0.18 (4.6) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom L3 Input Connector J1 Molex pn. 09-65-2038 Output Connector J2 Molex pn. 09-65-2068 Pin 1 2 3 4 5 6 Single Output +V1 +V1 +V1 RTN RTN RTN Fan Connector J3 Molex pn. 22-04-1021 Pin 1 2 Function Fan +(12 V) Fan - Notes 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. Weight: 0.65 lbs (0.29 kg) 7 0.15 (3.8) SMD Component Height 4. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. www.xppower.com Signal Connector J4 JST PN B10B-PHDSS Pin 1 2 3 4 5 6 7 8 9 10 Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C GCS Series AC-DC Power Supplies XP Power Mechanical Details GCS250 12-15 V models Note: Mounting points A should be connected together for optimum EMI performance 5.0 (127.0) 0.225 (5.72) 4.55 (115.57) 1.43 (36.3) 0.20 (5.1) T1 Q3 C45 A 3.00 (76.2) 2.15 (54.6) AIRFLOW 2.40 (61.0) C23 2.55 (64.77) Q1 C28 C6 A A 0.61 (15.6) 1.18 (29.8) 0.225 (5.72) 0.14 (3.5) 0.20 (5.1) 0.25 Faston Ground Tab 0.15 (3.8) SMD Component Height 0.18 (4.6) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom L3 GCS250 Other models Note: Mounting points A should be connected together for optimum EMI performance 5.0 (127.0) 0.225 (5.72) 4.55 (115.57) C45 Q3 1.43 (36.3) 0.20 (5.1) T1 A 3.00 (76.2) 2.15 (54.6) AIRFLOW 2.40 (61.0) C23 2.55 (64.77) Q1 C28 C6 A A 0.61 (15.6) 1.18 (29.8) 0.225 (5.72) 0.14 (3.5) 0.20 (5.1) 0.25 Faston Ground Tab Pin 1 2 Function Line Neutral 0.18 (4.6) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom L3 Input Connector J1 Molex pn. 09-65-2038 0.15 (3.8) SMD Component Height Output Connector J2 Molex pn. 09-65-2068 Pin 1 2 3 4 5 6 Single Output +V1 +V1 +V1 RTN RTN RTN Fan Connector J3 Molex pn. 22-04-1021 Pin 1 2 Function Fan +(12 V) Fan - Notes 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. Weight: 0.65 lbs (0.29 kg) 4. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. www.xppower.com Signal Connector J4 JST PN B10B-PHDSS Pin 1 2 3 4 5 6 7 8 9 10 Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C 8 GCS Series AC-DC Power Supplies XP Power Mechanical Details GCS350 model Note: Mounting points A should be connected together for optimum EMI performance 5.0 (127.0) 1.49 (37.8) 4.55 (115.57) 0.2 (5.72) 0.40 (10.2) Q3 T1 J1 21 M3 Screw 0.5 (12.6) - - 3.0 (76.2) + + A C6 1.84 (46.7) 2.55 (64.77) C23 Q1 C6 A 2 1 5 3 1 L3 (beneath heatsink) A J3 1.7 1.18 (44.8) 0.61 (29.8) (15.6) J4 4 2 0.15 (3.8) SMD Component height 0.22 (5.72) 0.25 faston ground tab 0.20 (5.1) M3 screw terminal bus bar Standard on 12/15 V models Optional on all other models, add suffix ‘-S’ e.g. GCS350PS24-S 0.18 (4.6) 4 x ø.156 (3.96) mounting hole ø.312 (7.92) clearance top and bottom 0.20 (5.1) 0.29 (7.4) 6 1 12 J2 J2 6 2 1 5 3 1 1 J3 2.4 (61.0) J4 4 5 3 1 2 6 Position single row Standard on 24/28/48/56 V models Input Connector J1 Molex pn. 09-65-2038 Pin 1 2 Notes Function Line Neutral Output Connector 6 position J2 Molex pn. 09-65-2068 Pin Function 1 +V1 2 +V1 3 +V1 4 RTN 5 RTN 6 RTN 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. Weight: 0.65 lbs (0.29 kg) 9 2 1 7 J3 J4 4 2 1.6 (40.6) 12 Position dual row Optional on 12/15 V models, add suffix ‘-J’ e.g. GCS350PS12-J Output Connector 12 position J2 Molex pn. 39-28-8120 Pin Function 1-3 RTN 4-6 +V1 7-9 RTN 10-12 +V1 Fan Connector J3 Molex pn. 22-04-1021 Signal Connector J4 JST PN B10B-PHDSS Pin 1 2 Pin 1 2 3 4 5 6 7 8 9 10 Function Fan +(12 V) Fan - 4. J1 mates with Molex Housing Pn. 09-50-1031. 6 position single row J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. 12 position dual row J2 mates with Molex Housing Pn. 39-01-2125 and with Molex series 5556 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. www.xppower.com Function +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C GCS Series AC-DC Power Supplies XP Power Mechanical Details Covered (-C) 0.39 (10.0) 4.72 (120.0) 4 x M3 x 0.5 THD 0.12 (3.0) max screw penetration 0.93 (23.7) 5.50 ±0.05 (139.7, ±1.27) 1 1 J3 2.64 (67.0) 2 2.39 (60.7) J4 10 1 2 6 J2 1 J1 2 3.48, ±0.05 (88.5, ±1.27) 0.85 (21.6) 0.25 Faston Ground Tab 0.43 (10.8) 0.45 (11.4) 0.45 (11.4) 1.70 (43.2) 4 x M3 x 0.5 THD 0.12 (3.0) max screw penetration 1.96 (50.0) 0.76 (19.3) 0.39 (10.0) Input Connector J1 Molex pn. 09-65-2038 Pin 1 2 Function Line Neutral 4.72 (120.0) Output Connector J2 Molex pn. 09-65-2068 Pin 1 2 3 4 5 6 Single Output +V1 +V1 +V1 RTN RTN RTN Fan Connector J3 Molex pn. 22-04-1021 Pin 1 2 Function Fan +(12 V) Fan - Notes 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP). 5. Weight: 1.05 lbs (0.48 kg) www.xppower.com Signal Connector J4 JST PN B10B-PHDSS Pin 1 2 3 4 5 6 7 8 9 10 Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C 10 GCS Series AC-DC Power Supplies XP Power Mechanical Details Top Fan (-TF) 0.39 (10.0) 4.72 (120.0) 2 x M3 x 0.5 THD 0.12 (3.0) max screw penetration 0.93 (23.7) 5.5 (139.7) 1 1 J3 2 J4 10 1 2 6 J2 1 J1 2 2.39 (60.7) 3.48 (88,5) 2.64 (67.0) 0.85 (21.6) 0.25 Faston Ground Tab 0.45 (11.4) 0.43 (10.8) 0.45 (11.4) 2.2 (57.8) 1.7 (43.2) 4 x M3 x 0.5 THD 0.12 (3.0) max screw penetration 1.96 (50.0) 0.76 (19.3) 0.39 (10.0) Input Connector J1 Molex pn. 09-65-2038 Pin 1 2 Function Line Neutral 4.72 (120.0) Output Connector J2 Molex pn. 09-65-2068 Pin 1 2 3 4 5 6 Single Output +V1 +V1 +V1 RTN RTN RTN Fan Connector J3 Molex pn. 22-04-1021 Pin 1 2 Function Fan +(12 V) Fan - Notes 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. 11 PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP). 5. Weight: 1.15 lbs (0.52 kg) www.xppower.com Signal Connector J4 JST PN B10B-PHDSS Pin 1 2 3 4 5 6 7 8 9 10 Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C GCS Series AC-DC Power Supplies XP Power Mechanical Details End Fan (-EF) GCS150/180/250 6.35 (161.3) 0.43 (10.8) J4 J3 6 1 2 1 0.84 (21.5) 0.45 (11.4) 5.50 (139.7) 2 x M3 x 0.5 THD 0.12 (3.0) max screw penetration J1 J2 2.63 (66.9) 10 1 2 3.48 (88.5) 1 2 1.90 (48.2) 1.10 [27.8] 0.45 (11.4) 0.25 Faston (Right Angle) Ground Tab 1.70 (43.2) 0.93 (23.7) 4.72 (120.0) 0.39 (10.0) 4 x M3 x 0.5 THD 0.12 (3.0) max screw penetration 0.76 (19.3) 1.96 (50.0) 0.39 (10.0) 4.72 (120.0) Input Connector J1 Molex pn. 09-65-2038 Pin 1 2 Function Line Neutral Output Connector J2 Molex pn. 09-65-2068 Pin 1 2 3 4 5 6 Single Output +V1 +V1 +V1 RTN RTN RTN Fan Connector J3 Molex pn. 22-04-1021 Pin 1 2 Function Fan +(12 V) Fan - Notes 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP). 5. Weight: 1.30 lbs (0.59 kg) www.xppower.com Signal Connector J4 JST PN B10B-PHDSS Pin 1 2 3 4 5 6 7 8 9 10 Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C 12 GCS Series AC-DC Power Supplies XP Power Mechanical Details End Fan (-EF) GCS350 6.00 (152.4) 0.68 (17.3) 0.56 (14.2) 1.75 (44.4) 0.70 (17.7) 0.24 (6.0) 0.99 1.48 (25.1) (37.7) 1.75 (44.4) 0.50 (12.6) 0.86 (21.9) Input Terminal Block Dinkle P/N DT-2C-A02W-03 2.02 1.42 (51.2) (36.2) 3.50 (88.9) M3 Screw 0.25 (6.4) 0.68 (17.2) 4.72 (120.0) 0.88 (22.3) 2 X M3 X 0.5 THD 0.12 (3.0) Max screw penetration 0.68 (17.2) 4.72 (120.0) 0.75 (18.9) 2.00 (50.8) 4 X M3 X 0.5 THD 0.12 (3.0) Max screw penetration Input Connector J1 Dinkle PN DJ-26-AD2W-03 Pin 1 2 3 Notes Function Line Neutral Output Connector 6 position J2 Molex pn. 09-65-2068 Pin Function 1 +V1 2 +V1 3 +V1 4 RTN 5 RTN 6 RTN 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. Weight: 0.65 lbs (0.29 kg) 13 Output Connector 12 position J2 Molex pn. 39-28-8120 Pin Function 1-3 RTN 4-6 +V1 7-9 RTN 10-12 +V1 Fan Connector J3 Molex pn. 22-04-1021 Signal Connector J4 JST PN B10B-PHDSS Pin 1 2 Pin 1 2 3 4 5 6 7 8 9 10 Function Fan +(12 V) Fan - 4. 6 position single row J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. 12 position dual row J2 mates with Molex Housing Pn. 39-01-2125 and with Molex series 5556 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. www.xppower.com Function +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C GCS Series AC-DC Power Supplies XP Power Thermal Considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See Mechanical Details for component locations. Temperature Measurements Component Max Temperature °C T1 Coil 120 ° C L3 Coil 120 ° C Q1 Body 120 ° C Q3 Body 120 ° C C6 105 ° C C23 105 ° C --Service Life The estimated service life of the GCS Series is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative service life in 24/7 operation. The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature. Estimated Service Life vs Component Temperature GCS150/180 GCS250 GCS350 165000 100000 60000 145000 80000 60000 40000 Lifetime (Hrs) 70000 Lifetime (Hrs) Lifetime (Hrs) 185000 120000 50000 40000 30000 20000 20000 95 85 75 65 55 95 85 65 105 55 Lifetime (Hrs) 145000 125000 105000 85000 65000 185000 165000 165000 145000 145000 125000 105000 85000 65000 65 65 55 125000 105000 85000 65000 5000 105 75 55 25000 5000 5000 65 45000 25000 25000 75 GCS350 185000 45000 45000 85 C6 Temperature (°C) Lifetime (Hrs) 165000 85 95 GCS250 185000 Lifetime (Hrs) 75 C6 Temperature (°C) GCS150/180 95 65000 5000 105 C6 Temperature (°C) 105 85000 25000 0 105 105000 45000 10000 0 125000 95 85 75 65 55 105 95 85 75 55 C23 Temperature (°C) C23 Temperature (°C) C23 Temperature (°C) www.xppower.com 20 July 2022
GCS250PS24 价格&库存

很抱歉,暂时无法提供与“GCS250PS24”相匹配的价格&库存,您可以联系我们找货

免费人工找货
GCS250PS24
    •  国内价格
    • 1+1263.35454

    库存:0