GSP500 Series
AC-DC Power Supplies
XP Power
500 Watts
• Convection/Forced-cooled Ratings
• Universal 80 - 264VAC Input
• IT & Medical Safety Approvals
• 95% (0 VAC), 8.3ms
Dip 30% (70 VAC), 416ms
A
A
A
Dip >95% (0 VAC), 4160ms
B
Dip >95% (0 VAC), 10.0ms
A
Dip 30% (168 VAC), 500ms
A
Dip >95% (0 VAC), 5000ms
B
Dip >95% (0 VAC), 10.0ms
A
Dip 60% (40 VAC), 100ms
A
Dip 30% (70 VAC), 500ms
A
Dip >95% (0 VAC), 5000ms
B
Dip >95% (0 VAC), 10.0ms
A
Dip 60% (96 VAC), 100ms
A
Dip 30% (168 VAC), 500ms
A
Dip >95% (0 VAC), 5000ms
B
Derate Output Power to 250 W
Safety Approvals
Safety Certification
CB Report
UL
EN
Safety Standard
Notes & Conditions
IEC60950-1 & IEC62368-1
Information Technology
IEC60601-1 Including Risk Management
Medical
UL62368-1, CSA62368-1 via cUL
Information Technology
ANSI/AAMI ES60601-1 & CSA C22.2, No.60601-1
Medical
EN62368-1
Information Technology
EN60601-1
Medical
Equipment Protection Class
Class I
See safety agency conditions of acceptibility for details
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Means of Protection
Category
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Primary to Earth
1 x MOPP (Means of Patient Protection)
55
IEC60601-1
www.xppower.com
GSP500 Series
AC-DC Power Supplies
XP Power
Mechanical Details
GSP500-EF
1.30 (33.00) X 2
A
A
0.20 (5.00)
5.65 (143.40)
6.71 (170.40)
LOGIC CONNECTOR
0.08 (2.00)
1 3
9 10
21
0.63 (15.90)
FAN CONNECTOR
LED
4.00 (101.60)
M4 SCREW-2X
TORQUE: 10.62lbs-in(1.2Nm) Max.
1.14 (28.90)
VOUT (-)
0.77 (19.45)
VOUT (+)
1.93 (48.94)
M3.5 SCREW 9.5mm CENTER
TORQUE: 10.62lbs-in(1.2Nm) Max.
N
L
0.82 (20.95)
7.00 (177.79)
5.65 (143.40)
0.02 (0.50)
AIRFLOW
DIRECTION
DETAIL A
Mounting Hole
8 PLCS M3 X 0.5
0.15 (3.8) MAX Penetration
Torque: 5 lb/in (0.6 Nm)
A
1.65 (41.90)
A
1.30 (33.00)
0.98 (24.90)
0.20 (5.00)
0.21 (5.39)
6.00 (152.40)
5.41 (137.40) X 2
A
Logic Connector(3)
for standard versions
JST B10B-PHDSS
A
4.00 (101.60)
2.36 (60.00)
CL
A
A
0.39 (10.00)X2
Fan Connector (3)
S3B-PH-KL(LF)
Pin
1
2
3
Function
+12 V
N/C
GND
Notes
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
3. Fan connector mates with JST housing PHR-3 and SPH-002T-P0.5S crimp
terminals or equivalent. Logic connector J301 mates with JST housing
PHDR-10VS and SPHD-001T-P0.5 crimp terminals.
www.xppower.com
Pin
1
2
3
4
5
6
7
8
9
10
Function
+Sense
-Sense
Power Fail
No Connection
No Connection
No Connection
+Inhibit
-Inhibit
+5V Standby
-5V Standby
Logic Connector (3)
For Current Share Versions -P
JST B10B-PHDSS
Pin
1
2
3
4
5
6
7
8
9
10
Function
+Sense
-Sense
Power Fail
No Connection
Current Share
Current Share
+Inhibit
-Inhibit
+5V Standby
-5V Standby
6
GSP500 Series
AC-DC Power Supplies
XP Power
Mechanical Details
GSP500
1.30 (33.00) X2
A
A
0.20 (5.00)
5.65 (143.40)
LOGIC CONNECTOR
6.00 (152.40)
0.63 (15.9) X2
1 3
9 10
21
FAN CONNECTOR
LED
M4 SCREW-2X
TORQUE: 10.62lbs-in(1.2Nm) Max.
1.14 (28.90)
VOUT (-)
0.77 (19.45)
4.00 (101.60)
VOUT (+)
N
L
5.65 (143.40)
0.02 (0.50)
DETAIL A
Mounting Hole
8 PLCS M3 X 0.5
0.15[3.8] MAX Penetration
Torque: 5 lb/in (0.6 Nm)
A
1.65 (41.90)
AIRFLOW
DIRECTION
at 12 CFM
A
1.30 (33.00)
0.98 (24.90)
0.20 (5.00)
0.21 (33.00)
6.00 (152.40)
Logic Connector(3)
for standard versions
JST B10B-PHDSS
5.41 (137.40)X2
A
Pin
1
2
3
4
5
6
7
8
9
10
A
4.00 (101.60)
2.36 (60.00)
CL
A
A
0.39 (10.00)X2
Fan Connector (3)
S3B-PH-KL(LF)
Pin
1
2
3
Function
+12 V
N/C
GND
Notes
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
77
3. Fan connector mates with JST housing PHR-3 and SPH-002T-P0.5S crimp
terminals or equivalent. Logic connector J301 mates with JST housing
PHDR-10VS and SPHD-001T-P0.5 crimp terminals.
www.xppower.com
Function
+Sense
-Sense
Power Fail
No Connection
No Connection
No Connection
+Inhibit
-Inhibit
+5V Standby
-5V Standby
Logic Connector (3)
For Current Share Versions -P
JST B10B-PHDSS
Pin
1
2
3
4
5
6
7
8
9
10
Function
+Sense
-Sense
Power Fail
No Connection
Current Share
Current Share
+Inhibit
-Inhibit
+5V Standby
-5V Standby
GSP500 Series
AC-DC Power Supplies
XP Power
Thermal Considerations - GSP500PSxx Models Only
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must
not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component
(out of direct air flow). See below for component locations.
Temperature Measurements (At Ambient 50 °C)
Component
Max Temperature °C
T1 Coil
120 ° C
L3 Coil
120 ° C
Q7 Body
120 ° C
Q102 Body
120 ° C
C20
105 ° C
C102
105 ° C
--
Service Life
The estimated service life of the GSP500PSxx Series is determined by the cooling arrangements and load conditions experienced in the end
application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a
key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative
service life in 24/7 operation.
The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this
temperature.
Estimated Service Life vs Component Temperature
70000
Q102
Lifetime (Hrs)
60000
50000
40000
30000
C20
20000
10000
C102
Q7
0
105
95
85
75
65
55
C20 Temperature (°C)
T1
350000
300000
Lifetime (Hrs)
250000
200000
L3
150000
100000
50000
0
105
95
85
75
65
55
C102 Temperature (°C)
www.xppower.com
06 July 2022
很抱歉,暂时无法提供与“GSP500PS24-EF”相匹配的价格&库存,您可以联系我们找货
免费人工找货