AC-DC
800 Watts
xppower.com
HDS800 Series
•
High Efficiency up to 92%
•
1U Profile, High Power Density
•
Programmable Output Voltage (0-105%)
•
Programmable Output Current (0-105%)
•
Parallel Operation
•
Fully Featured Signals & Controls
•
3 Year Warranty
Specification
Input
General
Input Voltage
• 90-264 VAC (127-370 VDC),
see derating curve
Input Frequency
• 47-63 Hz
Input Current
• 9.3 A/3.7 A typical at 100/240 VAC
Inrush Current
• 30.0 A/60.0 A typical at 115/230 VAC
Power Factor
• 0.98/0.95, typical at 115/230 VAC full load
Earth Leakage Current • 95% 10 ms, 30% 500 ms,
>95% 5000 ms, Perf Criteria A, A, B
UL62368-1, CSA C22.2 No 62368-1-14,
EN 62368-1, IEC62368-1:2014,
CE (Meets all applicable directives), UKCA
(Meets all applicable legislation)
Notes
1. Tolerance includes setup time tolerance, line regulation and load regulation
Output Power
Output Voltage V1
800 W
800 W
800 W
800 W
800 W
800 W
800 W
12.0 VDC
15.0 VDC
24.0 VDC
30.0 VDC
36.0 VDC
48.0 VDC
60.0 VDC
Output Current
Min
Max
0.0 A
66.7 A
0.0 A
53.4 A
0.0 A
33.5 A
0.0 A
26.7 A
0.0 A
22.3 A
0.0 A
16.7 A
0.0 A
13.4 A
Efficiency(2)
Model Number
89%
90%
92%
92%
92%
92%
92%
HDS800PS12
HDS800PS15
HDS800PS24
HDS800PS30
HDS800PS36
HDS800PS48
HDS800PS60
AC-DC
HDS800
Models and Ratings
Notes
1. Ripple & noise is measured with 20 MHz bandwidth and using 12”twisted pair-wire terminated with 0.1 μF & 47 μF capacitors in parallel.
2. Measured with 230 VAC input and full load.
Mechanical Details
1
1.61 (40.9)
9.80 (249.0)
+V
M6
-V
2
1
3 x M4 (bottom side)
Penetration Depth = 4mm
Max Torque = 1.27 Nm
2.91
(74.0)
Airflow
24
23
5.00
(127.0)
TRIM
STATUS
LED
CN2
E
2.52
(64.0)
N
L
0.55 (14.0)
7.80 (198.0)
1.46 (37.0)
0.81 (20.5)
1.06 (26.9)
6 x M4 (Both sides)
0.98 (25.0)
Penetration Depth = 4mm
Max Torque = 1.27 Nm
0.45 (11.5)
8.70 (221.0)
Pin Functio
Mating connector CN2: Manufacturer :JST Housing:
PHDR-24VS
Contacts: SPHD-002T-P0.5
(28-24 AWG)
1
Notes
1. All dimensions are in inches (mm).
2. Weight 3.85 lb (1.75 kg)
3. Maintain 2” (50mm) clear space at each end.
*Only usable with driver board “KIT-RS232-X”
or “KIT-RS485-1”
0.32 (8.0)
CN2 Control Pin Connections
Pin Function
Description
Description
VS+
Remote sense (+)
9
EN-
2
VO+
10
3
VS-
11
4
VO-
Positive Output
Voltage
Remote Sense (-)
Negative Output
Voltage
12
AUX
5
POK
Power OK
13
ACI
6
GND
PAR
15
8
VSET
Ground
Parallel Operation
Current Share
Aux Output Setting
14
7
16
Pin Function
Inhibit On/Off(-)
17
AUX
GND
Ground
18
GND
Ground
EN+
Inhibit On/Off (+)
+5V/0.5 A or +9V/0.3
A Standby power
19
SCL
I2C Serial Clock
20
SDA
I2C Serial Data
I Program
21
AUX
GND
Ground
22
GND
+5V/0.5 A or
+9V/0.3 A power
Ground
VCI
V Program
23
RX*
Receive
GND
Ground
24
TX*
Transmit
Derating Curve
Thermal Derating Curve
Input Derating Curve
100
100
90
80
Load (%)
Load (%)
80
60
40
70
60
20
50
-10
0
10
20
30
40
50
60
70
40
Ambient Temperature (˚C)
90
Description
+5V/0.5 A or +9V/0.3
A Standby power
100
110
120
Input Voltage (VAC)
264
LED Status
LED Status
Solid (Green)
Solid (Orange)
Slow Blink (Green)
Slow Blink (Orange)
Fast Blink (Red)
Solid (Red)
Slow Blink (Red)
Intermittent Blink (Red)
Short & Long Blink (Red)
Output Status
DC Output OK
DC Output OK in remote control mode
Output Not Enabled
Output Not Enabled in remote control mode
Over Voltage
Over Loaded
Over Temperature
Fan Fail
AUX Standby Failure
Output Voltage Programming
Via External Voltage
120
Via External Resistor
120
100
Output Voltage (%)
Output Voltage (%)
100
80
60
40
80
60
40
20
20
0
0
0
1
2
3
4.5 4.8 5
4
0
1
2
3
4
4.5 4.8
Resistor Value (k Ω )
Programming Voltage (VDC)
Output Current Program
Via External Voltage
120
Via External Resistor
120
100
Output Current (%)
100
Output Current(%)
AC-DC
HDS800
Application Notes
80
60
40
80
60
40
20
20
0
0
0
1
2
3
4
4.5
5
0
1
2
3
4.5
4
Resistor Value (k Ω )
Programming Voltage (VDC)
Remote Enable
*GND shown in the diagram (below) is referring to the GND of CN2, not the Grounding from output power (V-)
AUX
AUX
2KΩ
SW
2KΩ
EN+
OFF Power OFF
ON Power ON
AUX
AUX
2KΩ
EN+
L
H
AUX
EN-
EN-
GND
GND
OFF Power OFF
ON Power ON
EN+
SW
Power OFF
Power ON
External DC source
(Max = 9Vdc)
AUX
ENL/H
(A) Using internal auxilliary standby
GND
GND
(B) Using external transistor
(C) Using external voltage source
External Programming Voltage Connection
IC=1mA
IC=1mA
IC=1mA
I-sink
min 1mA
220R
CTRL
VCI/ACI
Power Supply
+
-
A/D
PWM
CTRL
VCI/ACI
Power Supply
VC = IC x R
0-5VDC
CTRL
VCI/ACI
Power Supply
R=0-5K
5
5
AC-DC
HDS800
Application Notes
OVP Setting
POK Signal
OVP Trip Point
POWER SUPPLY
AUX
200%
3300R
196%
Pok
Power not
1
120%
2
114%
Power OK
1
2
100% 105%
7%
GND
% of Nominal Output Voltage
CN2 Connector
Open drain signal, low when PSU turns on
Maximum sink current: 20 mA
Maximum drain voltage: 40 V
CN2
23
23
24
1
2
CN2
23
24
2
1
CN2
CN2
2
1
2
1
CN2
Remote Sense
23
24
23
24
Current Share
24
RX*
TX*
AUX
GND
SCL SDA
23
24
AUX GND
VCI
GND
ACI
GND
2
1
CN2
EN+
Load
AUX
EN-
GND
PAR
VSET
23
POK GND
VS-
VO-
VS+
VO+
1
Load
24
23
24
23
24
23
24
RX*
TX*
RX*
TX*
RX*
TX*
RX*
TX*
AUX
GND
AUX
GND
AUX
GND
AUX
GND
SCL
SDA
SCL
SDA
SCL
SDA
SCL
SDA
AUX
GND
AUX
GND
AUX
GND
AUX
GND
2
VCI
GND
VCI
GND
VCI
GND
VCI
GND
ACI
GND
ACI
GND
ACI
GND
ACI
GND
EN+
AUX
EN+
AUX
EN+
AUX
EN+
AUX
EN-
GND
EN-
GND
EN-
GND
EN-
GND
1
2
PAR
VSET
PAR
VSET
PAR
VSET
PAR
VSET
POK
GND
POK
GND
POK
GND
POK
GND
VS-
VO-
VS-
VO-
VS-
VO-
VS-
VO-
VS+
VO+
VS+
VO+
VS+
VO+
VS+
VO+
1
2
1
2
1
2
1
2
Local Sense
CN2
TX*
GND
SDA
AUX
GND
VCI
GND
ACI
GND
RX*
TX*
RX*
TX*
RX*
TX*
RX*
TX*
EN+
AUX
AUX
GND
AUX
GND
AUX
GND
AUX
GND
EN-
GND
SCL
SDA
SCL
SDA
SCL
SDA
SCL
SDA
PAR
VSET
AUX
GND
AUX
GND
AUX
GND
AUX
GND
POK
GND
2
SCL
23
24
Load
Current Sharing with Remote Sensing
24
RX*
AUX
CN2
1
23
1
VS-
VO-
VS+
VO+
23
2
Must be used if remote sense is not
required.
1
24
23
24
23
24
23
24
VCI
GND
VCI
GND
VCI
GND
VCI
GND
ACI
GND
ACI
GND
ACI
GND
ACI
GND
EN+
AUX
EN+
AUX
EN+
AUX
EN+
AUX
EN-
GND
EN-
GND
EN-
GND
EN-
GND
PAR
VSET
PAR
VSET
PAR
VSET
PAR
VSET
POK
GND
POK
GND
POK
GND
POK
GND
VS-
VO-
VS-
VO-
VS-
VO-
VS-
VO-
VS+
VO+
VS+
VO+
VS+
VO+
VS+
VO+
2
1
2
1
2
1
2
Current Sharing with Local Sensing
Notes
In parallel operation, it is possible that only one unit will operate if the load is less than 5% of the combined rated output load.
It is possible to have more than five units in parallel, contact sales for details.
*Pin 23 and 24, Only usable with driver board “KIT-RS232-X” or “KIT-RS485-1”
10 Nov 2022
很抱歉,暂时无法提供与“HDS800PS12”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+2759.45224
- 10+2704.26724
- 50+2650.18595