DCDC
3 Watts
xppower.com
JCB Series
•
2:1 Input Range
•
Operating Temperature 40 °C to +100 °C
•
Single & Dual Outputs
•
1500 VDC Isolation
•
Optional Isolation to 3000 VDC
•
Optional Metal Case
•
3 Year Warranty
Specification
Input
General
• 5 V (4.5-9 VDC)
12 V (9-18 VDC)
24 V (18-36 VDC)
48 V (36-72 VDC)
Input Current
• See table
Input Filter
• Pi network
Input Reflected Ripple • 35 mA pk-pk through 12 µH inductor
Input Surge
• 5 V models 15 VDC for 100 ms
12 V models 24 VDC for 100 ms
24 V models 40 VDC for 100 ms
48 V models 80 VDC for 100 ms
Undervoltage Lockout • None
Reverse Voltage
• None
Protection
Input Voltage Range
Output
Output Voltage
Minimum Load
Initial Set Accuracy
Line Regulation
Load Regulation
Cross Regulation
Transient Response
•
•
•
•
•
•
•
Ripple & Noise
Short Circuit Protection
Overvoltage Protection
Overcurrent Protection
Maximum Capacitive
Load
Temperature
Coefficient
•
•
•
•
•
See table
Minimum load required (see note 1)
±1% max
±0.5% max
±0.5% max
±5% on dual output models (see note 2)
2 MHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -40 °C to +100 °C, derate from 100% load
at +85 °C to no load at +100 °C
Case Temperature
• +100 °C max
Storage Temperature • -40 °C to +125 °C
Humidity
• Up to 95% RH, non-condensing
Cooling
• Natural convection
EMC & Safety
Emissions
ESD Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
• EN55022 Class A conducted &
radiated, with external components,
see application note
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
(see note 7)
• EN61000-4-5, installation class 3,
Perf Criteria A (see note 7)
• EN61000-4-6, 10 V rms, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
Input Voltage
Output Voltage
5.0
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
5.0
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
5.0
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
5.0
9.0
12.0
15.0
24.0
±5.0
±9.0
±12.0
±15.0
±24.0
4.5-9 V
9-18 V
18-36 V
36-72 V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
600
333
250
200
125
±300
±167
±125
±100
±63
600
333
250
200
125
±300
±167
±125
±100
±63
600
333
250
200
125
±300
±167
±125
±100
±63
600
333
250
200
125
±300
±167
±125
±100
±63
Maximum
Capacitive Load
Input Current(6)
No Load
Full Load
Output Current
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
40 mA
40 mA
40 mA
40 mA
40 mA
40 mA
40 mA
40 mA
40 mA
40 mA
20 mA
20 mA
20 mA
20 mA
20 mA
20 mA
20 mA
20 mA
20 mA
20 mA
12 mA
12 mA
12 mA
12 mA
12 mA
12 mA
12 mA
12 mA
12 mA
12 mA
8 mA
8 mA
8 mA
8 mA
8 mA
8 mA
8 mA
8 mA
8 mA
8 mA
857
833
810
810
857
869
857
833
810
857
328
324
316
316
316
324
320
320
320
320
156
156
152
152
156
160
158
156
156
156
81
80
78
78
78
80
79
78
78
78
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
2200
470
470
470
220
±1000
±220
±220
±220
±100
2200
470
470
470
220
±1000
±220
±220
±220
±100
2200
470
470
470
220
±1000
±220
±220
±220
±100
2200
470
470
470
220
±1000
±220
±220
±220
±100
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
µF
Efficiency
Model Number(3,4,5)
70%
72%
74%
74%
70%
69%
70%
72%
74%
70%
76%
77%
79%
79%
79%
77%
78%
78%
78%
78%
80%
80%
82%
82%
80%
78%
79%
80%
80%
80%
77%
78%
80%
80%
80%
78%
79%
80%
80%
80%
JCB0305S05
JCB0305S09
JCB0305S12
JCB0305S15
JCB0305S24
JCB0305D05
JCB0305D09
JCB0305D12
JCB0305D15
JCB0305D24
JCB0312S05
JCB0312S09
JCB0312S12
JCB0312S15
JCB0312S24
JCB0312D05
JCB0312D09
JCB0312D12
JCB0312D15
JCB0312D24
JCB0324S05
JCB0324S09
JCB0324S12
JCB0324S15
JCB0324S24
JCB0324D05
JCB0324D09
JCB0324D12
JCB0324D15
JCB0324D24
JCB0348S05
JCB0348S09
JCB0348S12
JCB0348S15
JCB0348S24
JCB0348D05
JCB0348D09
JCB0348D12
JCB0348D15
JCB0348D24
Notes
1. Minimum load required to meet noise and ripple and initial set accuracy
specifications. Below 25% load, noise and ripple increases to 200 mV pk-pk
typical and load regulation to ±1% max.
2. Cross regulation is ±5% when one output is at 100% the other is varied
between 25% and 100%.
3. For optional 3000 VDC isolation, add suffix ‘-H’ to end of part number.
4. For optional metal case version, add suffix ‘-M’ to end of part number,
eg. JCB0324S12-HM
5. For alternative pin out, add suffix ‘-Z’ to end of part number,eg. JCB0324S12-HMZ
6. Input current measured at nominal input voltage
7. A 220 µF/100 V capacitor across the input is required in order to meet
EN61000-4-4 & EN61000-4-5.
Mechanical Details and Application Notes
0.01
(0.25)
0.90
(22.86)
1
2
PIN CONNECTIONS
1.25 (31.75)
3
9
10 11 12
Bottom View
24 23 22
15.24
(0.60)
0.80
(20.32)
16 15 14 13
0.02
(0.50)
0.10
(2.54)
0.20
(5.08)
0.40
(10.16)
Input Filter
0.12 (3.05) Min.
+Vin
+
Model
+Vout
L
C1
-
DC/DC
Converter
-Vin
-Vout
LOAD
JCB0305
JCB0312
JCB0324
JCB0348
C1
220
220
220
220
*or higher for -H
µF/100
µF/100
µF/100
µF/100
L
V
V
V
V
12
12
12
12
µH
µH
µH
µH
C2
Pin
Single
Dual
Single-H
1
2
3
9
10
11
12
13
14
15
16
22
23
24
+Vin
N.C.
N.C.
N.P.
-Vout
+Vout
-Vin
-Vin
+Vout
-Vout
N.P.
N.C.
N.C.
+Vin
+Vin
-Vout
Common
N.P.
Common
+Vout
-Vin
-Vin
+Vout
Common
N.P.
Common
-Vout
+Vin
N.P.
-Vin
-Vin
N.P.
N.P.
N.C.
N.P.
N.P.
+Vout
N.P.
-Vout
+Vin
+Vin
N.P.
N.C. - No Connection
Dual-Z,
Dual-H Single-Z,
or -HZ
or -HZ
N.P.
N.P.
N.P.
-Vin
-Vin
-Vin
-Vin
-Vin
-Vin
Common
N.P.
Common
N.P.
N.P.
N.P.
-Vout
N.C.
-Vout
N.P.
N.P.
N.P.
N.P.
N.P.
N.P.
+Vout
+Vout
+Vout
N.P.
N.P.
N.P.
Common -Vout Common
+Vin
+Vin
+Vout
+Vin
+Vin
+Vout
N.P.
N.P.
N.P.
N.P. - No Pin
Notes
470 pF/2 KV/
MLCC*
1.
2.
3.
4.
5.
All dimensions are in inches (mm)
Weight: 0.04 lbs (20 g) approx.
Pin diameter: 0.02±0.002 (0.5±0.05)
Pin pitch tolerance: ±0.014 (±0.35)
Case tolerance: ±0.02 (±0.5)
C2
19-Nov-13
DCDC
JCB03
Models and Ratings
很抱歉,暂时无法提供与“JCB0305S24”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+95.081041+11.79476
- 5+92.212125+11.43887
- 10+89.4137310+11.09174
- 25+85.6109025+10.62000
- 100+79.86995100+9.90783