JTK30 Series
DC-DC Converter
XP Power
30 Watts
xxx Series
• Single and Dual Outputs
• 1” x 1” Footprint
• -40 °C to +100 °C Operation
• Full Load at 55 °C Ambient
• 1600 VDC Isolation
• Output Trim ±10%
• Remote On/Off
• MTBF 370 kHrs
• 3 Year Warranty
Dimensions:
JTK30:
1.0 x 1.0 x 0.43” (25.4 x 25.0 x 10.9 mm)
Models & Ratings
Input
Voltage
Output
Voltage
Input Current(1)
Output
Current
No Load
Full Load
OVP setting
Efficiency
Max.
capacitive load(2)
Model Number(3)
JTK3024S3V3
3.3 V
7.0 A
10 mA
1095 mA
3.9 V
88%
10000 μF
5.0 V
6.0 A
10 mA
1405 mA
6.2 V
89%
7200 μF
JTK3024S05
12.0 V
2.5 A
10 mA
1405 mA
15.0 V
89%
1200 μF
JTK3024S12
15.0 V
2.0 A
10 mA
1375 mA
18.0 V
91%
1000 μF
JTK3024S15
±12.0 V
±1.25 A
10 mA
1405 mA
±15.0 V
89%
±750 μF
JTK3024D12
±15 V
±1.0 A
10 mA
1375 mA
±18.0 V
91%
±500 μF
JTK3024D15
3.3 V
7.0 A
8 mA
540 mA
3.9 V
89%
10000 μF
5V
6.0 A
8 mA
695 mA
6.2 V
90%
7200 μF
JTK3048S05
12 V
2.5 A
8 mA
695 mA
15.0 V
90%
1200 μF
JTK3048S12
15 V
2.0 A
8 mA
680 mA
18.0 V
92%
1000 μF
JTK3048S15
±12 V
±1.25 A
8 mA
695 mA
±15.0 V
90%
±750 μF
JTK3048D12
±15 V
±1.0 A
8 mA
685 mA
±18.0 V
91%
±500 μF
JTK3048D15
9-36 V
18-75 V
JTK3048S3V3
Notes
1. Input currents measured at nominal input voltage.
2. Maximum capacitive load is per output.
3. Add suffix ‘-HK’ for optional heatsink.
Mechanical Details
0.1
(2.54)
Top View
0.4
(10.16)
4
6
5
0.8
(20.32)
3
2
1.0 (25.4)
1
0.1
(2.54)
0.6
(15.24)
Bottom View
1
0.2
(5.08)
0.1
(2.54)
0.5
(0.02)
0.41
(10.4)
1
1.0 (25.4)
0.66 (16.8)
2
Dia
0.04
(1.0)
DIA
0.04
(1.0)
1.0
(25.4)
3
0.3
(7.62)
0.1
(2.54)
0.24
(6.0)
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.042 lbs (19 g) approx.
3. Pin diameter: 0.04±0.002 (1.0±0.05)
Optional Heatsink (-HK)
6
5
4
1.0
(25.4)
0.4
(10.16)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
www.xppower.com
Pin
1
2
3
4
5
6
Pin Connections
Single
Dual
+Vin
+Vin
-Vin
-Vin
Remote On/Off
Remote On/Off
+Vout
+Vout
Trim
Common
-Vout
-Vout
JTK30 Series
DC-DC Converter
XP Power
Input
Characteristic
Input Voltage Range
Minimum
Maximum
Units
Notes & Conditions
9
Typical
36
VDC
24 V nominal
18
75
VDC
48 V nominal
Input Reflected Ripple Current
30
mA pk-pk
Through 12 μH inductor and 47 μF capacitor
50
VDC for 100 ms
24 V models
100
VDC for 100 ms
48 V models
Maximum
Units
Notes & Conditions
30
VDC
See Models and Ratings table
Input Surge
Output
Characteristic
Minimum
Output Voltage
3.3
Output Trim
±10
Typical
Initial Set Accuracy
Minimum Load
±1
0
%
Single Output Versions
%
At full load
%
No minimum load required
From minimum to maximum input at full load
Line Regulation
±0.5
%
Load Regulation
0.5/1.0
%
From 0% to full load for single/dual output
±5
%
On dual output models, when one output is at 100% load
and other is varied from 25% load to full load
75/60
mV pk-pk
Cross Regulation
Ripple & Noise
Overload Protection
170
%
Short Circuit Protection
Trip and Restart (hiccup), with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
0.02
%/ ˚C
Overvoltage Protection
Remote On/Off
Single output with 10 μF/25 V X7R MLCC on output
Dual output with 10 μF/25 V X7R MLCC on each output
measured using 20 MHz bandwidth
See Models and Ratings table
Output is on if remote on/off (pin 3) is open
Output turns off if remote on/off (pin 3) is low (
很抱歉,暂时无法提供与“JTK3024D12”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+259.20992
- 5+248.80103
- 20+238.87127