JTL60 Series
DC-DC Converter
XP Power
60 Watts
xxx Series
• Single and Dual Outputs
• Wide 4:1 Input Range
• 2” x 1” Footprint
• -40 °C to +85 °C Operation
• Full Load at 50 °C Ambient
• 1600 VDC Isolation
• Output Trim ±10%
• Remote On/Off
• 3 Year Warranty
Dimensions:
JTL60:
2.0 x 1.0 x 0.45” (50.8 x 25.4 x 11.5 mm)
The JTL60 series provides a compact, highly efficient and cost effective 60W DC-DC power
supply in a potted construction using a copper case for pcb mounting. Features include soft start,
over temperature protection, over voltage and over current protection.
Models & Ratings
Input
Voltage
Output
Voltage
9-36 V
Input Current(1)
Output
Current
No Load
Full Load
OVP setting
Efficiency
Max.
capacitive load(2)
Model Number(3)
5.0 V
12.0 A
25 mA
2705 mA
6.2 V
92%
30,000 μF
JTL6024S05
12.0 V
5.0 A
25 mA
2705 mA
15.0 V
92%
5850 μF
JTL6024S12
15.0 V
4.0 A
25 mA
2690 mA
20.0 V
93%
3900 μF
JTL6024S15
±12.0 V
±2.5 A
40 mA
2750 mA
±15.0 V
91%
±3900 μF
JTL6024D12
±15.0 V
±2.0 A
50 mA
2730 mA
±20.0 V
91%
±2400 μF
JTL6024D15
5V
12.0 A
25 mA
1345 mA
6.2 V
93%
30,000 μF
JTL6048S05
12 V
5.0 A
25 mA
1350 mA
15.0 V
92%
5850 μF
JTL6048S12
15 V
4.0 A
25 mA
1345 mA
20.0 V
93%
3900 μF
JTL6048S15
±12 V
±2.5 A
40 mA
1375 mA
±15.0 V
91%
±3900 μF
JTL6048D12
±15 V
±2.0 A
50 mA
1375 mA
±20.0 V
91%
±2400 μF
JTL6048D15
18-75 V
Notes
1. Input currents measured at nominal input voltage.
2. Maximum capacitive load is per output.
3. Add suffix ‘-HK’ for optional heatsink
Mechanical Details
Optional Heatsink (-HK)
0.10
(2.54)
0.10
(2.54)
0.40
0.40
(10.16) (10.16)
5
4
0.45
(11.5)
0.10
(2.54)
Print
Face
2.0
(50.8)
Bottom View
0.10
(2.54)
0.10
(2.54)
2
2.0
(50.8)
TOP
Dia
0.04
(1.0)
Pin Connections
Single
Dual
+Vin
+Vin
-Vin
-Vin
Remote On/Off Remote On/Off
+Vout
+Vout
-Vout
Common
Trim
-Vout
Notes
Dimensions inches (mm)
3
0.20
(5.08)
0.60 (15.24)
1
Pin
1
2
3
4
5
6
6
0.10
(2.59)
1
0.69
(17.6)
0.24
(6.0)
1.0 (25.4)
Heat-sink
Thermal Pad
Converter
www.xppower.com
1.
2.
3.
4.
Pin diameter 0.04 ±0.002 (1.0 ±0.05)
Pin pitch and length tolerance ±0.014 (±0.35)
Case tolerance +±0.02 (±0.5)
Stand-off tolerance ±0.004 (±0.1)
JTL60 Series
DC-DC Converter
XP Power
Input
Characteristic
Input Voltage Range
Minimum
Maximum
Units
Notes & Conditions
9
Typical
36
VDC
24 V nominal
18
75
VDC
48 V nominal
Input Reflected Ripple Current
20
Input Surge
mA pk-pk
Through 11 μH inductor and 22 μF capacitor
50
VDC for 100 ms
24 V models
100
VDC for 100 ms
48 V models
Maximum
Units
Notes & Conditions
30
VDC
See Models and Ratings table
Output
Characteristic
Minimum
Output Voltage
5.0
Output Trim
±10
Typical
Initial Set Accuracy
Minimum Load
±1
0
%
See Application Note
%
At full load
%
No minimum load required
From minimum to maximum input at full load
Line Regulation
±0.5
%
Load Regulation
0.5/1.0
`%
From 0% to full load for single/dual output
%
On dual output models, when one output is at 100% load
and other is varied from 25% load to full load
Cross Regulation
±5
Start Up Time
60
Ripple & Noise
Overload Protection
120
ms
100
mV pk-pk
140
%
Short Circuit Protection
Continuous hiccup mode, with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
0.02
%/ ˚C
Overvoltage Protection
Remote On/Off
Measured using 20 MHz bandwidth and 1.0 μF ceramic
capacitor
See Models and Ratings table
Output is on if remote on/off (pin 3) is open or high (3-12 VDC), relative to -Vin (pin 2)
Output turns off if remote on/off (pin 3) is low (
很抱歉,暂时无法提供与“JTL6048S12”相匹配的价格&库存,您可以联系我们找货