JVA15 Series
DC-DC Converter
XP Power
15 Watts
xxx Series
• Renewable Energy, Industrial Applications and EV Applications
• Ultrawide Input Range - 200-1500 VDC
• Fully Encapsulated PCB Mount & DIN Rail Versions
• Optional DIN Rail Versions with Built In EMI Filter & 1500 VDC Fuse
• -40 °C to +70 °C Operating Temperature
• 3 Year Warranty
The JVA series offers high isolation DC-DC converters with an ultra wide DC
input range. Configuration options provide convenient installation choices.
Dimensions:
JVA15: 4.92 x 2.95 x 1.57” (124.9 x 74.9 x 40.0 mm)
JVA15-D: 5.08 x 4.02 x 1.92” (129.0 x 102.0 x 49.0 mm)
JVA15-DF: 5.75 x 5.43 x 2.17” (146.05 x 137.9 x 55.0 mm)
Models & Ratings
Output Power Input Voltage
10 W
15 W
200-1500 V
Output
Voltage
Overvoltage
Output Current Input Current(1)
Protection (typical)
Typical
Efficiency(4)
Maximum
Capacitive Load
Model Number(2,3)
5.0 V
8.0 V
2000 mA
64%
6000 μF
JVA151500S05
12.0 V
20.0 V
1250 mA
71%
2000 μF
JVA151500S12
15.0 V
20.0 V
1000 mA
72%
1200 μF
JVA151500S15
24.0 V
30.0 V
625 mA
74%
470 μF
JVA151500S24
120 mA
Notes
1. At 200 VDC input
2. For DIN rail mount option, add suffix '-D' e.g. JVA151500S12-D
3. For DIN rail with added EMI filter option, add suffix '-DF' e.g. JVA151500S24-DF
4. At 800 VDC Input
Input
Characteristic
Input Voltage Range
Minimum
Typical
200
Maximum
Units
Notes & Conditions
1500
VDC
See derating curve
Input Current
120/30/16
mA
200 VDC/800 VDC/1500 VDC input
Inrush Current
50/150
A
200 VDC/1500 VDC input
Input Filter
Pi type
Undervoltage Lockout
On 180-195 V, Off 170-185 V
Input Protection
External 15 A/1500 VDC required
This is already included in the optional -DF version
Output
Characteristic
Minimum
Output Voltage
5
Initial Set Accuracy
Minimum Load
Typical
Maximum
Units
24
V
±2
0
A
2
s
Line Regulation
±1
%
Load Regulation
±1
Ripple & Noise
150
%
300
mV pk-pk
320
%
Short Circuit Protection
1
No minimum load required
0 - 100% load
20 MHz bandwidth
Trip & Restart (hiccup mode), auto recovery
120
Overvoltage Protection
Temperature Coefficient
See Models and Ratings table
%
Start Up Delay
Overload Protection
Notes & Conditions
Trip & Restart (hiccup mode)
See Models and Ratings table
0.02
%/ ˚C
www.xppower.com
JVA15 Series
DC-DC Converter
XP Power
General
Characteristic
Minimum
Typical
Efficiency
Isolation
Maximum
Notes & Conditions
%
4000
See Models and Ratings table
VAC
Switching Frequency
65
For 60 s
kHz
5000
Operating Altitude
Mean Time Between Failure
Units
72
m
300
Derate from 100% load at 2000 m to 80% load at 5000 m
kHrs
MIL-HDBK-217F, +25 °C GB
0.9 (400)
Weight
JVA15
1.01 (460)
lb (g)
JVA15-D
1.56 (710)
JVA15-DF
Environmental
Characteristic
Maximum
Units
Notes & Conditions
Operating Temperature
Minimum
-40
Typical
+70
°C
See derating curve
Storage Temperature
-40
+85
°C
Case Temperature
Humidity
5
95
°C
95
%RH
Non-condensing
Cooling
Natural convection
Shock
±3 shocks in each plane, total 18 shocks of 30 g : 11 ms halfsine. Conforms to EN60068-2-27 & EN60068-2-47
Vibration
10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55032
Level A
Radiated
EN55032
Level A
Notes & Conditions
See application notes. Not required for ‘-DF’
versions
EMC: Immunity
Phenomenon
Standard
Immunity
EN55035
Test Level
Criteria
ESD Immunity
EN61000-4-2
±6 kV Contact, ±8 kV Air
A
Radiated Immunity
EN61000-4-3
10 V/m
A
EFT/Burst
EN61000-4-4
3
A
Surges
EN61000-4-5
3
A
Conducted Immunity
EN61000-4-6
10 Vrms
A
Magnetic Fields
EN61000-4-8
10 A/m
A
Notes & Conditions
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
EN
EN62109
Photovoltaic Power System
UL
UL1741/CSA-C22.2 No.107-1
Distributed Energy Resources
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
www.xppower.com
2
JVA15 Series
DC-DC Converter
XP Power
Application Notes
Input Voltage 300-1500 VDC
Thermal Derating Curve
100
90
Output Power (%)
80
70
60
JVA151500S05, S12, S15 with
input voltage 200-300 VDC
50
40
JVA151500S24 with
input voltage 200-300 VDC
0
-40
0
Ambient Temperature (°C)
50
70
100
Input Derating Curve
90
Output Power (%)
80
70
60
50
40
30
20
10
0
200
0
Input Voltage (VDC)
1200
1500
EMI Filter for Conducted Emissions
Model
L1
Fuse
+Input
L2
C1
C7
C9
C10
-Input
C3
+
C4
C2
JVA151500S15
R1
JVA151500S24
R2
+
Lo
JVA40
+
C5
+
C6
JVA151500S12
TVS
+Vo
+Vin
+
C8
Element Model
C7/C8/C9/C10
R3
C3/C4/C5/C6
R4
R1/R2/R3/R4
-Vin
-Vo
L1
L2
Fuse
3
C1 (μF)
JVA151500S05
www.xppower.com
1
C2 (μF)
120
120
120
68
TVS
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ30A
Recommended Value
104K/275 VAC
47 μF/450 VDC
1 MΩ/2 W
330 μH/1 A
7 mH/1 A
3 A UL/CE marked/15 A/1500 VDC
JVA15 Series
DC-DC Converter
XP Power
Mechanical Details
Standard PCB mount
1.57
(40.0)
Front View
0.23
(6.0)
4 ø 0.138 (ø 3.50)
4.92 (125.0)
4.54 (115.5)
Third Angle Projection
5 ø 0.067 (ø 1.70)
5 ø 0.047 (ø 1.20)
2.95
(75.0)
2
3
2.57
(65.5)
1
5
4
Bottom View
1.6
(40.6)
0.40
(10.16)
4
1
5
Pin
1
2
3
4
5
Pin Connections
Function
-Vin
+Vin
No Connection
-Vo
+Vo
3
2
4-M3 (0.118)
4.40 (111.76)
Note:Grid 2.54*2.54mm
Optional DIN rail mount, -D
5.07 (129.0)
9
7
8
Right
View
Front View
4.01
(102.0)
1
2
3
4
Pin
1
2
3
4
5
6
7
8
9
6
Pin Connections
Function
+Vo
-Vo
No Connection
No Connection
No Connection
+Vin
+Vin
-Vin
-Vin
5
LED
1.92 (49.0)
Optional DIN rail mount with filter, -DF
5.78 (146.0)
LED
9
8
7
6
5
2 x M3 Screws
Unscrew two scres to
replace the fuse from
shell
5.43
(138.0)
2.16
(55.0)
Front View
1
2
3
Bottom View
Pin
1
2
3
4
5
6
7
8
9
Pin Connections
Function
-Vin
-Vin
+Vin
+Vin
+Vo
-Vo
No Connection
No Connection
No Connection
4
Notes
1. All dimensions are in inches (mm)
2. Weight: Standard PCB mount: 0.66 lbs (300 g) approx
Optional DIN rail mount, -D: 0.79 lbs (360 g) approx
Optional DIN rail mount with filter, -DF: 1.34 lbs (610 g) approx
www.xppower.com
06 July 2022
很抱歉,暂时无法提供与“JVA151500S15”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+1325.62207
- 3+1271.51505
- 国内价格
- 1+972.06363
- 3+933.25780
- 国内价格
- 1+1021.27497
- 3+980.50457