0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MPQ-120B

MPQ-120B

  • 厂商:

    XPPOWER

  • 封装:

  • 描述:

    MPQ-120B - 1~4 Output Medical Type - XP Power Limited

  • 数据手册
  • 价格&库存
MPQ-120B 数据手册
1~4 Output Medical Type 120W Medical Features Universal AC input / Full range Low leakage current 100M Ohms for I/P-O/P, I/P-FG, O/P-FG by using 500VDC test voltage. EMI COMPLIANCE EMI Specifications Conducted & Radiation Harmonic distortion Voltage flicker EMS COMPLIANCE EMS Specification ESD air ESD contact RF field susceptibility EFT(Electrical Fast Transient)/Burst Lightning/Surge Conducted RF susceptibility Magnetic field immunity Voltage dip, interruption Digital phone carrier immunity MTBF 262,100 hours min. at full load and 25 calculated per MIL-HDBK-217F. DIMENSION (L*W*H) 177.8x107.95x35.5mm or 7"x4.25"x1.4" PACKING 0.55Kg; 24pcs/14.5Kg/1.04CUFT Compliance Level EN55011, Class B EN55022, Class B EN61000-3-2 EN61000-3-3 Compliance Level EN61000-4-2, Level 3, 8KV EN61000-4-2, Level 2, 4KV EN61000-4-3, Level 2, 3V/m Level 3, 10V/m EN61000-4-4, Level 2, 1KV/5KHz Level 3, 2KV/5KHz EN61000-4-5, Level 4, 2KV/Line-Line 4KV/Line-Earth EN61000-4-6, Level 2, 3Vrms/m Level 3, 10Vrms/m EN61000-4-8, Level 2, 3A/m Level 3, 10A/m EN61000-4-11,Compliance ENV50204, Level 2, 3V/m, 900MHz Level 3, 10A/m, 900MHz of ambient temperature, File Name:120W MEDICAL-SPEC 2006-04-13 1 ~4 Output Medical Type Output Chart MODEL MPS-120-3.3 MPS-120-5 MPS-120-12 MPS-120-15 MPS-120-24 MPS-120-48 MPD-120A OUTPUT VOLTAGE 3.3V 5V 12V 15V 24V 48V 5V 12V MPD-120B 5V 24V MPT-120A 5V 12V -5V MPT-120B 5V 12V -12V MPT-120C 5V 15V -15V MPT-120D 5V 24V 12V MPQ-120B 5V 12V -5V -12V MPQ-120C 5V 15V -5V -15V MPQ-120D 5V 12V 24V -12V MPQ-120E 5V 12V 15V 24V Notes : 120W Medical WITH FAN (25CFM) 24A 22A 10A 8A 5A 2.5A 10A 5A 10A 2.9A 10A 4.8A 0.6A 10A 4.4A 0.6A 10A 4A 0.6A 10A 2.2A 0.6A 10A 4.2A 0.6A 0.6A 10A 3.2A 0.6A 0.6A 10A 1A 2.1A 0.6A 10A 3A 0.6A 0.6A RIPPLE & NOISE VOLTAGE PEAK LOAD (Max.) TOLERANCE WITH 25CFM FAN (Note 2) (Note 3) 26A 26A 11A 8.8A 5.5A 2.8A 12A 6A 12A 3.2A 12A 5.8A 1A 12A 5.3A 1A 11A 4.4A 1A 12A 2.64A 1A 11A 5A 1A 1A 11A 3.8A 1A 1A 11A 1.1A 2.3A 1A 11A 3.3A 1A 1A 80mVp-p 80mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 80mVp-p 250mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 150mVp-p 80mVp-p 80mVp-p 300mVp-p 120mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 150mVp-p 80mVp-p 80mVp-p 80mVp-p 150mVp-p 300mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 2.0% 7.0% 2.0% 8.0% 2.0% +8,-6% 5.0% 2.0% 6.0% 5.0% 2.0% +6,-7% 5.0% 2.0% +8,-6% 5.0% 2.0% 6.0% 5.0% 5.0% 2.0% +6,-7% 5.0% 5.0% 2.0% +8,-6% 8.0% 5.0% 2.0% 6.0% 8.0% 5.0% series RATED CURRENT 24A 22A 10A 8A 5A 2.5A 10A 5A 10A 2.9A 10A 4.8A 0.6A 10A 4.4A 0.6A 10A 4A 0.6A 10A 2.2A 0.6A 10A 4.2A 0.6A 0.6A 10A 3.2A 0.6A 0.6A 10A 1A 2.1A 0.6A 10A 3A 0.6A 0.6A OUTPUT CURRENT MINIMUM LOAD 0A 0A 0A 0A 0A 0A 2A 0.5A 2A 0.3A 2A 0.4A 0A 2A 0.4A 0A 2A 0.4A 0A 2A 0.4A 0A 2A 0.5A 0A 0A 2A 0.5A 0A 0A 2A 0.2A 0.3A 0A 2A 0.5A 0A 0A CONVECTION (max.) 16A 14.7A 6.7A 5.3A 3.3A 1.7A 7.3A 3.6A 7A 1.9A 7.3A 3.5A 0.3A 7.3A 3.2A 0.4A 7A 2.6A 0.4A 7.3A 1.6A 0.4A 7.3A 3.1A 0.4A 0.4A 7.3A 2.4A 0.4A 0.4A 7A 0.7A 1.4A 0.3A 7.3A 2.3A 0.4A 0.4A LINE LOAD REGULATION REGULATION EFFICIENCY 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 2.0% 0.5% 2.0% 0.5% 1.5% 0.5% 0.5% 1.5% 0.5% 0.5% 2.0% 0.5% 0.5% 3.0% 0.5% 0.5% 1.5% 0.5% 0.5% 0.5% 2.0% 0.5% 0.5% 0.5% 2.0% 2.0% 0.5% 0.5% 2.0% 2.0% 0.5% 3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 0.5% 3.5% 0.5% 4.0% 1.0% 3.5% 1.0% 1.0% 3.5% 1.0% 1.0% 3.5% 1.0% 1.0% +4,-3% 1.0% 0.5% 3.5% 1.0% 1.0% 0.5% 3.5% 1.0% 1.0% 0.5% 3.5% 3.5% 1.0% 0.5% 3.0% 3.0% 1.0% 73% 74% 71% 71% 74% 72% 73% 72% 68% 73% 77% 79% 81% 82% 75% (Note 4) 76% 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:120W MEDICAL-SPEC 2006-04-13 1~4 Output Medical Type Mechanical Specification 177.8[7"] 165.1 [6.5"] 120W Medical series Unit:mm CN1 5 4 3 2 1 13 12 11 10 9 8 7 6 5 4 3 2 1 CN2 +V ADJ 10cm 4- 3.96[0.156"] FAN 35.5 [1.4"] Pin Assignment AC Intput Connector (CN1) : Molex 5273-05 or equivalent Pin No. 1 2,4 3 5 MPS-120 FG No Pin AC/N AC/L MPD-120 FG No Pin AC/N AC/L MPT-120 FG No Pin AC/N AC/L MPQ-120 FG No Pin AC/N AC/L Mating Housing Molex 5195 or equivalent Terminal Molex 5194 or equivalent DC Output Connector (CN2) : Molex 5273-13 or equivalent Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 MPS-120 +V +V +V -V -V -V -V +V +V P.F.D. NC No Pin NC MPD-120 V1 V1 V1 COM COM COM COM V2 V2 P.F.D. NC No Pin NC MPT-120 V1 V1 V1 COM COM COM COM V2 V2 P.F.D. V3 No Pin NC MPQ-120 V1 V1 V1 COM COM COM COM V2 V2 P.F.D. V3 No Pin V4 Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Derating Curve 100 Static Characteristics 100 25CFM forced air cooling 80 90 MPS/D-120 Convection cooling 53W MPS-120-3.3 only 73.7W MPS-120-5 only 80W others 80 70 60 LOAD (%) 40 MPT/Q-120 LOAD(%) 60 50 40 20 -20 0 10 20 30 40 50 55 60 70 (HORIZONTAL) 90 100 115 107.95[4.25"] 135 95.25[3.75"] 155 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:120W MEDICAL-SPEC 2006-04-13
MPQ-120B 价格&库存

很抱歉,暂时无法提供与“MPQ-120B”相匹配的价格&库存,您可以联系我们找货

免费人工找货