SRH05 Series
DC-DC Converter
XP Power
0.5 Amp
xxx Series
• 3 Pin Switching Regulator
• SIP Package
• Ultra Wide Input Range to 72 V
• -40 °C to +85 °C Operation
• Full Load to 60 °C Ambient
• Class B Conducted & Radiated Emissions
• MTBF >4.5 MHrs
• 3 Year Warranty
The SRH05 series of switching regulators provides a convenient cost effective solution to nonisolated DC-DC regulated voltage conversation applications. Operating from a wide DC input the
SRH05 will step down to voltages from 3.3V to 15V DC. Features include continuous short circuit
protection, high efficiency and an industrial operating temperature range.
Dimensions:
SRH05:
0.46 x 0.29 x 0.4” (11.68 x 7.5 x 10.16 mm)
Models & Ratings
Input Current
Full Load,
Full Load,
min Vin
max Vin
Input
Voltage
Output
Voltage
Output
Current
No Load
9-72 V
3.3 V
500 mA
3 mA
225 mA
9-72 V
5.0 V
500 mA
3 mA
315 mA
9-72 V
6.5 V
500 mA
3 mA
14-72 V
7.2 V
500 mA
14-72 V
9.0 V
17-72 V
21-72 V
Efficiency
min Vin
max Vin
Max capacitive
load
Model Number
30 mA
82%
75%
100 μF
SRH05S3V3
45 mA
88%
80%
100 μF
SRH05S05
395 mA
55 mA
91%
83%
100 μF
SRH05S6V5
3 mA
285 mA
60 mA
91%
84%
100 μF
SRH05S7V2
500 mA
3 mA
350 mA
75 mA
92%
86%
100 μF
SRH05S09
12.0 V
500 mA
3 mA
375 mA
95 mA
94%
89%
100 μF
SRH05S12
15.0 V
400 mA
3 mA
300 mA
95 mA
95%
89%
100 μF
SRH05S15
Mechanical Details
0.46 (11.68)
Printed
Face
0.38
(9.66)
0.02
(0.50)
0.20
(5.08)
0.16
(4.10)
0.29
(7.50)
0.02 (0.5)
0.40
(10.16)
0.30
(7.70)
0.08
(2.0)
Pin Connections
0.02
(0.5)
0.01 (0.25)
0.10
(2.54)
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.004 lbs (2.1 g) approx.
3. Pin diameter: 0.02±0.002 (0.5±0.05)
1
4. Pin pitch tolerance: ±0.02 (±0.5)
5. Case tolerance: ±0.02 (±0.5)
www.xppower.com
Pin
1
2
3
Single
+Vin
Ground
+Vout
SRH05 Series
DC-DC Converter
XP Power
Input
Characteristic
Input Voltage Range
Input Filter
Minimum
Typical
9
Maximum
Units
Notes & Conditions
72
VDC
Model dependant. See Models and Ratings table
Capacitor
Input Reflected Ripple
35
mA pk-pk
Input Surge
75
VDC for 100 ms
Through 12 μH inductor and 47 μF capacitor
Maximum
Units
Notes & Conditions
15
VDC
See Models and Ratings table
3
%
At full load
mA
Minimum load required to meet specification. Operation at
no load will not cause damage.
Output
Characteristic
Minimum
Output Voltage
3.3
Typical
Initial Set Accuracy
Minimum Load
10
Line Regulation
1.0
%
Load Regulation
0.6
%
From 10% to full load
Transient Response
±3
%
For 25% load change
Ripple & Noise
75
mV pk-pk
20 MHz bandwidth
Short Circuit Protection
Continuous, with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
0.02
%/ ˚C
Maximum
Units
General
Characteristic
Minimum
Typical
Efficiency
Isolation: Input to Output
92
0
Switching Frequency
120
Mean Time Between Failure
4.5
Notes & Conditions
%
See models and ratings table
VDC
Non isolated
kHz
See application notes
800
MHrs
Weight
0.004 (2.1)
Soldering temp
MIL-HDBK-217F, +25 °C GB
lb (g)
260
Case material
Non-conductive black plastic UL94V-0 rated
Pin material
Solder coated C5191R-H
Potting material
Silicon UL94V-0 rated
°C
Waveflow. 0.05” (1.5mm) from case, 10 seconds max.
Environmental
Characteristic
Maximum
Units
Operating Temperature
Minimum
-40
Typical
+85
°C
Storage Temperature
-40
+125
°C
Case Temperature
Humidity
Notes & Conditions
Derate from 100% load at +60 °C to 40% at +85 °C
+100
°C
95
%RH
Non-condensing
Cooling
Natural convection
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Conditions
Conducted
EN55032
Class B
See Application Note
Radiated
EN55032
Class B
See Application Note
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
ESD Immunity
EN61000-4-2
±6 kV/±8 kV
A
Radiated Immunity
EN61000-4-3
10 Vrms
A
EFT/Burst
EN61000-4-4
±2.0 kV
A
See Application Note
Surges
EN61000-4-5
±1.0 kV
A
See Application Note
Conducted Immunity
EN61000-4-6
10 V rms
A
Magnetic Fields
EN61000-4-8
1 A/m
A
www.xppower.com
Notes & Conditions
Contact discharge/Air discharge
2
SRH05 Series
DC-DC Converter
XP Power
Safety Approvals
Agency
Standard
Test Level
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Notes & Conditions
Application Note
Standard Application
+Vin
+Vout
SRH05
C1
C2
-Vin
-Vout
C1 = 3.3 µF/100 V required if input voltage is above 50 VDC
C2 = 100 µF (optional) to improve transient response
EMI & Surge/EFT Filter
+Vin
SRH05
L1
C1
C2
C1 = 220 µF/100 V
L1 = 12 µH
C2 = 220µF/100 V
Load
-Vin
C1, C2 and L1 should be placed as close to the SRH05 as possible
Switching Frequency vs Load
800
700
Frequency (KHz)
600
500
400
300
200
100
50
10
10
50 100
200
300
400
500
Output Current (mA) (Vin = 24 V - 72 V)
3
www.xppower.com
02 Nov 2021
很抱歉,暂时无法提供与“SRH05S12”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+67.30463
- 10+65.61759
- 20+64.59704
- 国内价格 香港价格
- 1+64.995751+7.83444
- 5+63.072255+7.60259
- 10+61.0793610+7.36237
- 25+58.4942625+7.05077
- 100+54.57967100+6.57891