TR10 Series
DC-DC Converter
XP Power
1 Amp
xxx Series
• 1A Switching Regulator
• Regulated Single Outputs of 3.3V and 5V DC
• Wide Input Range to 28V
• SIP3 Package
• Non Isolated
• High Efficiency to 93%
• Class B Conducted & Radiated Emissions
• Short Circuit Protection
• Low 1.5mA Standby Input Current
• -40°C to +85°C Operation
Dimensions:
• MTBF >3.8MHrs
TR10:
0.46 x 0.29 x 0.4” (11.68 x 7.5 x 10.16 mm)
• 3 Year Warranty
The TR10 provides a compact efficient switching regulator solution operating
from a wide range DC input with popular regulated output voltages of 3.3V
and 5V. This convenient, cost-effective solution features short circuit protection
and an industrial operating temperature range.
Models & Ratings
Input Current
Input Voltage Output Voltage Output Current
No Load
Full Load,
min. Vin
Full Load,
max. Vin
Max. Capacitive
Load
Efficiency
with full load
Min. Vin
Max. Vin
Model
Number
7-28 V
3.3 V
1000 mA
1.5 mA
530 mA
145 mA
220 μF
89%
82%
TR10S3V3
8-28 V
5.0 V
1000 mA
1.5 mA
670 mA
210 mA
220 μF
93%
86%
TR10S05
Notes
1. Standard tube quantity 30 pcs
Mechanical Details
0.29
(7.5)
0.46
(11.68)
0.38
(9.66)
0.02
(0.50)
TR10
0.13 (3.30)
0.02 (0.50)
Printed
Face
0.16
(4.1)
Pin Connections
1
0.40
(10.16)
0.30
(7.70)
2
3
2.0 (0.08)
0.02 (0.5)
1
0.10
(2.54)
2
3
0.20 (5.08)
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.004 lbs (2.1 g) approx.
3. Pin diameter: 0.02±0.002 (0.5±0.05)
1
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
www.xppower.com
0.01
(0.25)
Pin
1
2
3
Single
+Vin
Ground
+Vout
TR10 Series
DC-DC Converter
XP Power
Input
Characteristic
Input Voltage Range
Input Filter
Minimum
Typical
7
Maximum
Units
Notes & Conditions
28
VDC
See Models and Ratings table
Integral capacitor
Input Reflected Ripple
35
mA pk-pk
Input Surge
30
VDC for 100 ms
Through 12 μH inductor and 47 μF capacitor
Output
Characteristic
Minimum
Output Voltage
3.3
Typical
Maximum
Units
Notes & Conditions
5
VDC
See Models and Ratings table
2.5
%
At full load
mA
Minimum load required to meet specification. Operation at
no load will not cause damage.
Initial Set Accuracy
Minimum Load
100
Line Regulation
1.0
%
Load Regulation
1.5
%
From 10% to full load
Transient Response
±3
%
For 25% load change
Ripple & Noise
100
mV pk-pk
Short Circuit Protection
20 MHz bandwidth
Continuous, with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
0.02
%/ ˚C
General
Characteristic
Minimum
Typical
Efficiency
Isolation: Input to Output
Units
%
0
VDC
Switching Frequency
Mean Time Between Failure
Maximum
90
330
MHrs
0.004 (2.1)
Non isolated
MIL-HDBK-217F, +25 °C GB
lb (g)
Case Material
Non-conductive black plastic UL94V-0
Pin Material
Solder Coated C5191R-H
Potting Material
Silicon, UL94V-0 rated
Water Washing
Use de-ionised water, do not soak, dry thoroughly
260
Soldering Temperature
See models and ratings table
kHz
3.8
Weight
Notes & Conditions
°C
Wave solder peak, 1.5mm from case 10s max. Not suitable
for vapour phase soldering. For further details contact
XP Power applications team.
Environmental
Characteristic
Operating Temperature
Storage Temperature
Case Temperature
Humidity
Cooling
Minimum
-40
-55
Typical
Maximum
+85
+125
+105
95
Units
°C
°C
°C
%RH
Notes & Conditions
Derate from 100% load at +60 °C to 40% at +85 °C
Non-condensing
Natural convection
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Conditions
Conducted
EN55032
Class B
See Application Note
Radiated
EN55032
Class B
EMC: Immunity
Phenomenon
ESD Immunity
Radiated Immunity
EFT/Burst
Surges
Conducted Immunity
Magnetic Fields
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Test Level
±6 kV/±8 kV
20 Vrms
±2.0 kV
±0.5 kV
10 V rms
100 A/m
Criteria
A
A
A
A
A
A
www.xppower.com
Notes & Conditions
Contact discharge/Air discharge
External input capacitor required 330 μF/100 V
External input capacitor required 330 μF/100 V
2
TR10 Series
DC-DC Converter
XP Power
Safety Approvals
Agency
Standard
Test Level
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Notes & Conditions
Application Notes
Standard Application
+Vin
C1
+
TR10
+
Vin
GND
Vout
+
C2
+Vout
+
-Vin
C1
C2
22 μF
47 μF
(optional) to improve
transient response
-Vout
Input Filter to meet Class B Conducted Emissions
+Vin
C3
+
L1
C4
+
TR10
+
Vin
GND
Vout
+
Load
C3
L1
C4
10 μF, 50 V
22 μH
10 μF, 50 V
C3, C4 and L1 should be placed as close to the TR10
as possible
Notes
-Vin
Suggested capacitor type MLCC with low ESR
For inductor use saturation current higher than 2A with a low
DCR rating. Suggested size to be 5 x 5mm minimum.
Output power
Derating Curve
Ambient temperature (°C)
www.xppower.com
23 March 2022