UCP180 Series AC-DC Power Supplies XP Power 180 Watts • 120W convection cooled -40°C to +70°C operation • 180W with 10CFM forced air cooling -20°C to +70°C operation • 4.3” x 2.5” footprint • Low 1.16” profile U channel construction • ITE & Medical (BF, 2 x MOPP) approvals • Class B conducted & Class A radiated emissions • Input voltage range 85 to 264VAC • Output voltages from 12 to 48VDC • No load input power 0.9 Input Current - Full Load Inrush Current Earth Leakage Current A 115/230 VAC 120 A 230 VAC cold start, 25 ºC 115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max) 95/180 No load Input Power Input Protection 230 VAC, 100% load. EN61000-3-2 class A 2.2/1.1 245 μA 0.5 W F3.15 A/250 V Internal fuse fitted in line and neutral. Output - Main Output Characteristic Output Voltage - V1 Minimum Typical 12 Initial Set Accuracy Minimum Load Units Notes & Conditions 48 VDC See Models and Ratings table ±1 % 50% load, 115/230 VAC A No minimum load required s 115/230 VAC full load 0 Start Up Delay Hold Up Time Maximum 2 10 19/13 ms Min at full load, 115 VAC. Typical at 120 W/ 180 W Drift ±0.02 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC Load Regulation ±0.5 % 0-100% load 4 % Recovery within 1% in less than 500 μs for a 50-75% and 75-50% load step 10 % Transient Response Over/Undershoot 5 Ripple & Noise 1 % pk-pk Full load 20 MHz bandwidth and 10 μF electrolytic capacitator in parallel with 0.1 μF ceramic capacitator Overvoltage Protection 110 140 % Vnom, recycle input to reset Overload Protection 110 175 % Of forced cooled rating 0.02 %/˚C Short Circuit Protection Temperature Coefficient Trip & Restart www.xppower.com 2 UCP180 Series AC-DC Power Supplies XP Power General Characteristic Minimum Typical Efficiency Maximum Units 94 Isolation: Input to Output Input to Ground Output to Ground % 230 VAC Full load (see fig. 1 to 2) 4000 VAC 2 MOPP 1500 VAC 1 MOPP 1500 VAC 1 MOPP μA kHz At 264 VAC, 60 Hz PFC 80 kHz Main converter 12.2/8.1 W/in3 Forced/convection-cooled 300 kHrs MIL-HDBK-217F, Notice 2 +25 °C GB 0.53 (240) lb(g) For U channel version Patient Leakage Current 50 80 130 37 Switching Frequency Notes & Conditions 50 Power Density Mean Time Between Failure Weight Efficiency Vs Load Figure 1 UCP180PS12 at 180 W 100% Efficiency 90% 115Vac 80% 230Vac 70% 60% 10 20 30 40 50 60 70 80 90 100 Load (%) Figure 2 UCP180PS24 at 180 W 100% Efficiency 90% 115Vac 80% 230Vac 70% 60% 10 20 30 40 50 60 70 80 Load (%) 3 www.xppower.com 90 100 UCP180 Series AC-DC Power Supplies XP Power Environmental Characteristic Minimum Typical Maximum Units °C Operating Temperature -40 +70 Storage Temperature -40 +85 Cooling 10 Humidity 5 Operating Altitude Notes & Conditions -40 °C for 120 W load, -20 °C for 180 W load, See derating curve, fig.3 and fig.4 °C CFM Forced-cooled > 120W 95 %RH Non-condensing 5000/4000 m ITE/Medical Shock ±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27 Vibration Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 Temperature Derating Curves Figure 3 - 120 W Convection Cooled 60 0 -40 Some specification parameters may not be met Output Load (W) 120 -20 0 +50 +70 Ambient Temperature (ºC) Figure 4 - 180 W Forced Cooled Output Load (W) 180 90 0 -20 0 +50 +70 Ambient Temperature (ºC) www.xppower.com 4 UCP180 Series AC-DC Power Supplies XP Power EMC: Emissions Phenomenon Conducted Radiated Standard Test Level EN55011/32 Class B EN55011/32 Class A Harmonic Current EN61000-3-2 Class A Voltage Functions EN61000-3-3 Criteria Notes & Conditions Class B with King Core ferrites Output cable: KCF-130-B Input cable for 120 W load: K5B RC 14x28.5x7-M for all models with additional KCF-130-B on 48V version. Input cable for 180 W load: K5B RC 14x28.5x7-M plus KCF-130-B. EMC: Immunity Phenomenon Medical Device EMC Low Voltage PSU EMC Standard Test Level Criteria IEC60601-1-2 Ed.4.0 : 2014 as below EN61204-3 High severity level as below ESD EN61000-4-2 4 A Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Magnetic Fields EN61000-4-8 4 A Dip >95% (0 VAC), 8.3 ms EN55035 (100 VAC) EN55035 (240 VAC) Dips and Interruptions EN60601-1-2 (100 VAC) EN60601-1-2 (240 VAC) Notes & Conditions ±8kV contact, ±15kV air A Dip 30% (70 VAC), 416 ms A Dip >95% (0 VAC), 4160 ms Dip >95% (0 VAC), 10.0 ms B A Dip 30% (168 VAC), 500 ms A Dip >95% (0 VAC), 5000 ms B Dip 100% (0 VAC), 10.0 ms A Dip 100% (0 VAC), 20 ms B Dip 60% (40 VAC), 100 ms B Dip 30% (70 VAC), 500 ms A Dip 100% (0 VAC), 5000 ms B Dip 100% (0 VAC), 10.0 ms A Dip 100% (0 VAC), 20 ms B Dip 60% (96 VAC), 100 ms B Dip 30% ( 168 VAC), 500 ms A Dip 100% (0 VAC), 5000 ms B Criteria A with load derated to 35 W Criteria A with load derated to 160 W Safety Approvals Safety Agency CB Report UL EN 5 Safety Standard Notes & Conditions IEC60950-1-1, IEC62368-1 Information Technology IEC60601-1 Medical UL62368-1 Information Technology ES60601-1 Medical EN62368-1 Information Technology EN60601-1 Medical CE Meets all applicable directives UKCA Meets all applicable legislation Isolation Safety Standard Primary to Secondary 2 x MOPP (Means of Patient Protection) Notes & Conditions Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Suitable for use in BF applied part applications www.xppower.com UCP180 Series AC-DC Power Supplies XP Power Mechanical Details Standard U-Channel Version 0.57 (14.5) 3.10 (78.7) 0.57 (14.5) 1.16 (29.5) 0.70 (17.8) M3 x 0.5 mounting holes (in 2 positions) 0.36 (9.2) 4.24 (107.6) 3.10 (78.7) L4 2.47 (62.8) 1.75 (44.5) CN2 CN1 TR1 C2 C52 CN3 M3 x 0.5 mounting holes (in 4 positions) 0.36 (9.2) Safety earth connection is via the Fast-on tab indicated by symbol M3 x 0.5 mounting holes (in 2 positions) CN1 Pin 1 AC-L Pin 2 Pin 3 AC-N Mates with JST VHR-3N housing and SVH-21T-P1.1 crimps CN3 CN2 Pin 1 +Vo Pin 1 Fan - Pin 2 +Vo Pin 2 Fan + Pin 3 +Vo Pin 4 Com Pin 5 Com Pin 6 Com Mates with Molex 22-01-1022 housing and 2759 crimps Mates with JST VHR-6N housing and SVH-21T-P1.1 crimps Notes 1. All dimensions shown in inches (mm). Tolerance: ±0.02 (0.5) 2. Weight: 0.53 lbs (240 g) approx. www.xppower.com 6 UCP180 Series AC-DC Power Supplies XP Power Mechanical Details Covered Version (-C suffix) 0.57 (14.5) 1.40 (35.5) 3.10 (78.7) 0.57 (14.5) 1.16 (29.5) 0.70 (17.8) M3 x 0.5 mounting holes (in 2 positions) 0.36 (9.2) 4.24 (107.6) 3.10 (78.7) L4 2.47 (62.8) 1.75 (44.5) CN2 CN1 C2 TR1 C52 CN3 M3 x 0.5 mounting holes (in 4 positions) 0.36 (9.2) Safety earth connection is via any of the U-channel mounting points M3 x 0.5 mounting holes (in 2 positions) CN1 Pin 1 AC-L Pin 2 Pin 3 AC-N Mates with JST VHR-3N housing and SVH-21T-P1.1 crimps CN3 CN2 Pin 1 +Vo Pin 1 Fan - Pin 2 +Vo Pin 2 Fan + Pin 3 +Vo Pin 4 Com Pin 5 Com Pin 6 Com Mates with JST VHR-6N housing and SVH-21T-P1.1 crimps Notes 1. All dimensions shown in inches (mm). Tolerance: ±0.02 (0.5) 2. Weight: 0.61 lbs (275 g) approx. 7 www.xppower.com Mates with Molex 22-01-1022 housing and 2759 crimps UCP180 Series AC-DC Power Supplies XP Power Thermal Considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See Mechanical Details for component locations. Temperature Measurements (At Maximum Ambient) Component TR1 Coil L4 Coil C2 C52 Max Temperature °C 110°C 120°C 105°C 105°C Service Life The estimated service life of the UCP180 is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor within the product when installed in the end application, The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature. Estimated Service Life vs Component Temperature Figure 5 80000 70000 60000 Lifetime (Hrs) 50000 C2 & C52 40000 30000 20000 10000 0 105 95 85 75 65 55 45 C2 + C52 Temperature (ºC) www.xppower.com 20 July 2022
UCP180PS15 价格&库存

很抱歉,暂时无法提供与“UCP180PS15”相匹配的价格&库存,您可以联系我们找货

免费人工找货