UCP180 Series
AC-DC Power Supplies
XP Power
180 Watts
• 120W convection cooled -40°C to +70°C operation
• 180W with 10CFM forced air cooling -20°C to +70°C operation
• 4.3” x 2.5” footprint
• Low 1.16” profile U channel construction
• ITE & Medical (BF, 2 x MOPP) approvals
• Class B conducted & Class A radiated emissions
• Input voltage range 85 to 264VAC
• Output voltages from 12 to 48VDC
• No load input power 0.9
Input Current - Full Load
Inrush Current
Earth Leakage Current
A
115/230 VAC
120
A
230 VAC cold start, 25 ºC
115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max)
95/180
No load Input Power
Input Protection
230 VAC, 100% load. EN61000-3-2 class A
2.2/1.1
245
μA
0.5
W
F3.15 A/250 V Internal fuse fitted in line and neutral.
Output - Main Output
Characteristic
Output Voltage - V1
Minimum
Typical
12
Initial Set Accuracy
Minimum Load
Units
Notes & Conditions
48
VDC
See Models and Ratings table
±1
%
50% load, 115/230 VAC
A
No minimum load required
s
115/230 VAC full load
0
Start Up Delay
Hold Up Time
Maximum
2
10
19/13
ms
Min at full load, 115 VAC. Typical at 120 W/ 180 W
Drift
±0.02
%
After 20 min warm up
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±0.5
%
0-100% load
4
%
Recovery within 1% in less than 500 μs
for a 50-75% and 75-50% load step
10
%
Transient Response
Over/Undershoot
5
Ripple & Noise
1
% pk-pk
Full load
20 MHz bandwidth and 10 μF electrolytic capacitator in
parallel with 0.1 μF ceramic capacitator
Overvoltage Protection
110
140
%
Vnom, recycle input to reset
Overload Protection
110
175
%
Of forced cooled rating
0.02
%/˚C
Short Circuit Protection
Temperature Coefficient
Trip & Restart
www.xppower.com
2
UCP180 Series
AC-DC Power Supplies
XP Power
General
Characteristic
Minimum
Typical
Efficiency
Maximum
Units
94
Isolation: Input to Output
Input to Ground
Output to Ground
%
230 VAC Full load (see fig. 1 to 2)
4000
VAC
2 MOPP
1500
VAC
1 MOPP
1500
VAC
1 MOPP
μA
kHz
At 264 VAC, 60 Hz
PFC
80
kHz
Main converter
12.2/8.1
W/in3
Forced/convection-cooled
300
kHrs
MIL-HDBK-217F, Notice 2 +25 °C GB
0.53 (240)
lb(g)
For U channel version
Patient Leakage Current
50
80
130
37
Switching Frequency
Notes & Conditions
50
Power Density
Mean Time Between Failure
Weight
Efficiency Vs Load
Figure 1
UCP180PS12 at 180 W
100%
Efficiency
90%
115Vac
80%
230Vac
70%
60%
10
20
30
40
50
60
70
80
90
100
Load (%)
Figure 2
UCP180PS24 at 180 W
100%
Efficiency
90%
115Vac
80%
230Vac
70%
60%
10
20
30
40
50
60
70
80
Load (%)
3
www.xppower.com
90
100
UCP180 Series
AC-DC Power Supplies
XP Power
Environmental
Characteristic
Minimum
Typical
Maximum
Units
°C
Operating Temperature
-40
+70
Storage Temperature
-40
+85
Cooling
10
Humidity
5
Operating Altitude
Notes & Conditions
-40 °C for 120 W load, -20 °C for 180 W load,
See derating curve, fig.3 and fig.4
°C
CFM
Forced-cooled > 120W
95
%RH
Non-condensing
5000/4000
m
ITE/Medical
Shock
±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27
Vibration
Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
Temperature Derating Curves
Figure 3 - 120 W Convection Cooled
60
0
-40
Some specification
parameters may not be met
Output Load (W)
120
-20
0
+50
+70
Ambient Temperature (ºC)
Figure 4 - 180 W Forced Cooled
Output Load (W)
180
90
0
-20
0
+50
+70
Ambient Temperature (ºC)
www.xppower.com
4
UCP180 Series
AC-DC Power Supplies
XP Power
EMC: Emissions
Phenomenon
Conducted
Radiated
Standard
Test Level
EN55011/32
Class B
EN55011/32
Class A
Harmonic Current
EN61000-3-2
Class A
Voltage Functions
EN61000-3-3
Criteria
Notes & Conditions
Class B with King Core ferrites
Output cable: KCF-130-B
Input cable for 120 W load: K5B RC 14x28.5x7-M
for all models with additional KCF-130-B on 48V
version.
Input cable for 180 W load: K5B RC 14x28.5x7-M
plus KCF-130-B.
EMC: Immunity
Phenomenon
Medical Device EMC
Low Voltage PSU EMC
Standard
Test Level
Criteria
IEC60601-1-2
Ed.4.0 : 2014
as below
EN61204-3
High severity level
as below
ESD
EN61000-4-2
4
A
Radiated
EN61000-4-3
3
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
3
A
Magnetic Fields
EN61000-4-8
4
A
Dip >95% (0 VAC), 8.3 ms
EN55035 (100 VAC)
EN55035 (240 VAC)
Dips and Interruptions
EN60601-1-2 (100 VAC)
EN60601-1-2 (240 VAC)
Notes & Conditions
±8kV contact, ±15kV air
A
Dip 30% (70 VAC), 416 ms
A
Dip >95% (0 VAC), 4160 ms
Dip >95% (0 VAC), 10.0 ms
B
A
Dip 30% (168 VAC), 500 ms
A
Dip >95% (0 VAC), 5000 ms
B
Dip 100% (0 VAC), 10.0 ms
A
Dip 100% (0 VAC), 20 ms
B
Dip 60% (40 VAC), 100 ms
B
Dip 30% (70 VAC), 500 ms
A
Dip 100% (0 VAC), 5000 ms
B
Dip 100% (0 VAC), 10.0 ms
A
Dip 100% (0 VAC), 20 ms
B
Dip 60% (96 VAC), 100 ms
B
Dip 30% ( 168 VAC), 500 ms
A
Dip 100% (0 VAC), 5000 ms
B
Criteria A with load derated to 35 W
Criteria A with load derated to 160 W
Safety Approvals
Safety Agency
CB Report
UL
EN
5
Safety Standard
Notes & Conditions
IEC60950-1-1, IEC62368-1
Information Technology
IEC60601-1
Medical
UL62368-1
Information Technology
ES60601-1
Medical
EN62368-1
Information Technology
EN60601-1
Medical
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Isolation
Safety Standard
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Notes & Conditions
Primary to Earth
1 x MOPP (Means of Patient Protection)
Secondary to Earth
1 x MOPP (Means of Patient Protection)
Suitable for use in BF applied part applications
www.xppower.com
UCP180 Series
AC-DC Power Supplies
XP Power
Mechanical Details
Standard U-Channel Version
0.57
(14.5)
3.10 (78.7)
0.57
(14.5)
1.16
(29.5)
0.70
(17.8)
M3 x 0.5 mounting holes (in 2 positions)
0.36
(9.2)
4.24 (107.6)
3.10 (78.7)
L4
2.47
(62.8)
1.75
(44.5)
CN2
CN1
TR1
C2
C52
CN3
M3 x 0.5 mounting holes (in 4 positions)
0.36
(9.2)
Safety earth connection is via
the Fast-on tab indicated by
symbol
M3 x 0.5 mounting holes (in 2 positions)
CN1
Pin 1
AC-L
Pin 2
Pin 3
AC-N
Mates with JST VHR-3N housing
and SVH-21T-P1.1 crimps
CN3
CN2
Pin 1
+Vo
Pin 1
Fan -
Pin 2
+Vo
Pin 2
Fan +
Pin 3
+Vo
Pin 4
Com
Pin 5
Com
Pin 6
Com
Mates with Molex 22-01-1022
housing and 2759 crimps
Mates with JST VHR-6N housing
and SVH-21T-P1.1 crimps
Notes
1. All dimensions shown in inches (mm).
Tolerance: ±0.02 (0.5)
2. Weight: 0.53 lbs (240 g) approx.
www.xppower.com
6
UCP180 Series
AC-DC Power Supplies
XP Power
Mechanical Details
Covered Version (-C suffix)
0.57
(14.5)
1.40
(35.5)
3.10 (78.7)
0.57
(14.5)
1.16
(29.5)
0.70
(17.8)
M3 x 0.5 mounting holes (in 2 positions)
0.36
(9.2)
4.24 (107.6)
3.10 (78.7)
L4
2.47
(62.8)
1.75
(44.5)
CN2
CN1
C2
TR1
C52
CN3
M3 x 0.5 mounting holes (in 4 positions)
0.36
(9.2)
Safety earth connection is via
any of the U-channel mounting points
M3 x 0.5 mounting holes (in 2 positions)
CN1
Pin 1
AC-L
Pin 2
Pin 3
AC-N
Mates with JST VHR-3N housing
and SVH-21T-P1.1 crimps
CN3
CN2
Pin 1
+Vo
Pin 1
Fan -
Pin 2
+Vo
Pin 2
Fan +
Pin 3
+Vo
Pin 4
Com
Pin 5
Com
Pin 6
Com
Mates with JST VHR-6N housing
and SVH-21T-P1.1 crimps
Notes
1. All dimensions shown in inches (mm).
Tolerance: ±0.02 (0.5)
2. Weight: 0.61 lbs (275 g) approx.
7
www.xppower.com
Mates with Molex 22-01-1022
housing and 2759 crimps
UCP180 Series
AC-DC Power Supplies
XP Power
Thermal Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must
not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component
(out of direct air flow). See Mechanical Details for component locations.
Temperature Measurements (At Maximum Ambient)
Component
TR1 Coil
L4 Coil
C2
C52
Max Temperature °C
110°C
120°C
105°C
105°C
Service Life
The estimated service life of the UCP180 is determined by the cooling arrangements and load conditions experienced in the end application.
Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor
within the product when installed in the end application,
The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature.
Estimated Service Life vs Component Temperature
Figure 5
80000
70000
60000
Lifetime (Hrs)
50000
C2 & C52
40000
30000
20000
10000
0
105
95
85
75
65
55
45
C2 + C52 Temperature (ºC)
www.xppower.com
20 July 2022