UCP225 Series
225W
AC-DC POWER SUPPLIES
CONVECTION
COOLED
The UCP225 series is designed to minimize the no load power consumption and maximize
efficiency to facilitate equipment design to meet the latest environmental legislation.
Approved for medical and ITE applications, this range of single output AC/DC power supplies
are packaged in an ultra-low profile 1.18” height with a foot print of just 3.12” by 5.0”. The
UCP225 provides up to 225W force-cooled or 150W convection-cooled leading to very high
power densities of 12.2W/in3 or 8.1W/in3 respectively. A 12V, 500mA fan supply is included
in the design which can also be delivered with an optional 5V/2A standby output. The power
supply contains two fuses and low leakage currents as required by medical applications and is
safety approved to operate in a 70°C ambient. The low profile and safety approvals covering
ITE and medical standards along with conducted emissions to EN55011/32 level B allow the
Applications
versatile UCP225 series to be used in a vast range of applications.
Features
• Low 1.18” Profile U Channel Construction
Healthcare
Home
Healthcare
Industrial
Electronics
Instrumentation
Security
Technology
• -40°C to +70°C Operation
• 3.12” by 5.0” Footprint
• 150W Convection/225W Forced Cooled Ratings
• Optional 5V Standby and Remote On/Off
Dimensions
• 12V Fan Output
• Medical and ITE Approvals
UCP225:
• High Efficiency, up to 95%
5.00 x 3.12 x 1.18” (127.0 x 79.2 x 29.2 mm)
• Less than 0.5W No Load Input Power
Models & Ratings
Model Number(3,4,5,6)
Output Voltage
Output Current
Optional Standby Output
Convection-cooled
Forced-cooled(1)
Convection-cooled
Forced-cooled(1)
Fan Output(7,8)
Efficiency(2)
UCP225PS12
12V
12.50A
18.75A
5V/1.0A
5V/2.0A
12V/0.5A
92%
UCP225PS15
15V
10.00A
15.00A
5V/1.0A
5V/2.0A
12V/0.5A
92%
UCP225PS18
18V
8.33A
12.50A
5V/1.0A
5V/2.0A
12V/0.5A
92%
UCP225PS24
24V
6.25A
9.38A
5V/1.0A
5V/2.0A
12V/0.5A
92%
UCP225PS28
28V
5.36A
8.04A
5V/1.0A
5V/2.0A
12V/0.5A
92%
UCP225PS36
36V
4.16A
6.25A
5V/1.0A
5V/2.0A
12V/0.5A
92%
UCP225PS48
48V
3.10A
4.69A
5V/1.0A
5V/2.0A
12V/0.5A
92%
Notes:
1. Requires 10CFM or optional top fan cover, -TF
2. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 225 W load
and 230 VAC input
3. Add suffix -T for input and output screw terminals e.g. UCP225PS24-T
4. Add suffix -TF for fan cover version e.g. UCP225PS24-TF
5. Add suffix -C for vented cover version e.g. UCP225PS24-C
6. Add suffix -A for optional 5V, 2A standby and remote on/off e.g. UCP225PS24-A
7. Typical voltage, actual regulated voltage will be in range of 10.5V to 11.1V
8. Regulation of the fan output requires a minimum load of 10W on the main output.
UCP225 Series
AC-DC POWER SUPPLIES
Summary
Characteristic
Input Voltage Range
Minimum
Typical
Maximum
Units
Notes & Conditions
85
115/230
264
VAC
Derate from 100% at 90VAC to 90% at 85VAC
0.5
No Load Input Power
W
94
Efficiency
-40
Operating Temperature
+70
%
Model dependent
°C
-40°C for 150 W load, -25°C for 225W load, see derating curve
EMC
EN55011/32 Level B Conducted & Level A Radiated, EN61000-3-2, EN61000-3-3
Safety Approvals
IEC62368-1, IEC60601-1, UL62368-1, EN60601-1
Input
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage - Operating
85
115/230
264
VAC
Derate output from 100% at 90VAC to 90% at 85VAC
Input Frequency
47
50/60
63
Hz
>0.9
Power Factor
Input Current - Full Load
Inrush Current
2.2/1.1
A
115/230VAC
120
A
230VAC, cold start 25°C
80/140
Earth Leakage Current
230VAC, 100% load. EN61000-3-2 class A, class C >145W
No Load Input Power
230
μA
0.5
W
When main input is inhibited
F3.15 A/250 V Internal fuse fitted in line and neutral
Input Protection
Output - Main Output
Characteristic
Output Voltage - V1
Minimum
Typical
12
Initial Set Accuracy
Minimum Load
Maximum
Units
Notes & Conditions
48
VDC
See Models & Ratings table
±1
%
50% load, 115/230VAC
A
No minimum load required
s
115/230VAC, full load
0
2
Start Up Delay
ms
Minimum at full load, 115VAC. Typical at 150W/225W
Drift
±0.02
%
After 20 min warm up
Line Regulation
±0.5
%
90-264VAC
Load Regulation
±0.5
%
0-100% load
4
%
Recovery within 1% in less than 500μs for a 50-75% and 75-50%
load step
9
%
Full load
1
% pk-pk
Hold Up Time
10
20/13
Transient Response
5
Over/Undershoot
Ripple & Noise
Overvoltage Protection
110
140
%
Overload Protection
110
175
% I nom
0.02
%/°C
Overtemperature Protection
Vnom, recycle input to reset
Trip & restart
Short Circuit Protection
Temperature Coefficient
20MHz bandwidth and 10μF electrolytic capacitator in parallel with
0.1μF ceramic capacitator
Measured internally, auto resetting
2
UCP225 Series
AC-DC POWER SUPPLIES
Output - Optional 5 V Standby Output
Characteristic
Minimum
Typical
Maximum
5.0
Output Voltage
0
Minimum Load
0.5
Start Up Delay
300
Hold Up Time
Notes & Conditions
VDC
±1
Initial Set Accuracy
Units
%
50% load, 115/230VAC
A
No minimum load required
s
115/230VAC, full load
ms
Minimum at full load, 115VAC. Typical at 150W/225W
Drift
±0.02
%
After 20 min warm up
Line Regulation
±0.5
%
90-264VAC
Load Regulation
±0.5
%
0-100% load
Transient Response
4
%
Recovery within 1% in less than 500μs for a 50-75% and 75-50%
load step
Over/Undershoot
5
%
Full load
1.2
% pk-pk
4.0
A
0.02
%/°C
Ripple & Noise
2.4
Overload Protection
20MHz bandwidth and 10μF electrolytic capacitator in parallel with
0.1μF ceramic capacitator
Trip & restart
Short Circuit Protection
Temperature Coefficient
Connect pin 3 of CN2 to pin 1 to turn main output off. Connect to pin 2 or leave open to turn main output on
Remote On/Off
General
Characteristic
Minimum
Typical
Maximum
94
Efficiency
Units
%
Notes & Conditions
Model dependent
Isolation: Input to Output
4000
VAC
2 x MOPP
Input to Ground
1500
VAC
1 x MOPP
Output to Ground
1500
40
Switching Frequency
50
VAC
1 x MOPP
130
kHz
PFC
80
kHz
Main converter
kHz
For optional standby output
65
12.2/8.1
W/in
Forced/convection-cooled
300
khrs
MIL-HDBK-217F, Notice 2 +25°C GB
0.71 (320)
lb (g)
For U channel version
Power Density
Mean Time Between Failure
Weight
3
Specifications subject to change without notice.
3
Efficienc
Convecon-cooled
UCP225 Series
Forced-cooled
115VAC input
85%
230VAC input
80%
75%
70%
100%
10
20
30
40
50
60
80
90
100
AC-DC
POWER
SUPPLIES
70
Load (%)
95%
90%
Efficiency
Efficiency Graphs
Forced-cooled
115VAC input
230VAC input
Efficiency
Efficiency
Convecon-cooled
10
20
30
40
50
60
70
80
90
70%
100
100%
115VAC input
230VAC input
20
Efficiency
30
40
50
60
70
Load (%)
Convecon-cooled
80
90
95%
70%
100
Forced-cooled
90%
115VAC input
230VAC input
Efficiency
10
Efficiency
115VAC input
230VAC input
20
30
40
50
60
70
80
90
100
Convecon-cooled
Forced-cooled
115VAC input
230VAC input
10
20
30
40
Convecon-cooled
50
60
70
80
90
100
Forced-cooled
Load (%)
115VAC input
230VAC input
80%
30
40
50
60
70
80
90
100%
100
Convecon-cooled
Forced-cooled
115VAC input
85%
10
20
Figure 4
95%
UCP225PS24-A
90%
Load (%)
230VAC input
Efficiency
20
30
40
50
60
70
80
90
100
Load (%)
Convecon-cooled
Forced-cooled
115VAC input
85%
230VAC input
80%
80%
75%
100%
100%
75%
70%
95%
10
20
30
40
50
Convecon-cooled
60
70
80
90
100
Forced-cooled
Load (%)
85%
10
20
90%
115VAC input
230VAC input
80%
Efficiency
Efficiency
100
85%
70%
10
90%
30
40
Convecon-cooled
85%
50
60
70
Load (%)
80
90
100
Forced-cooled
115VAC input
230VAC input
80%
75%
75%
10
20
30
40
50
60
70
80
90
70%
100
100%
Load (%)
95%
10
20
30
40
50
60
70
80
90
100
Load (%)
95%
Convecon-cooled
90%
Forced-cooled
115VAC input
85%
230VAC input
80%
75%
100%
Efficiency
90%
Efficiency
90
75%
Figure 3
95%
UCP225PS24
10
20
85%
Characteristic
30
40
Convecon-cooled
50
60
70
Load (%)
Minimum
80
90
70%
100
70%
40
50
60
Load (%)
Cooling
95%
90%
Humidity
Typical
115VAC input
Maximum
230VAC input
Units
+70
°C
-40
70
80
90
100
230VAC input
5
10
20
30
40
50
60
70
80
90
100
Forced-cooled
95
%RH
230VAC input
5000/4000
m
115VAC input
Notes & Conditions
-40°C for 150W load, -25°C for 225W load. See derating curves,
figures 5 and 6
°C
CFM
Operating Altitude
80%
+85
10
Convecon-cooled
85%
115VAC input
Load (%)
Forced-cooled
-40
Operating
Temperature
75%
100%
Forced-cooled
80%
80%
Storage10Temperature
20
30
Convecon-cooled
85%
75%
Environmental
90%
Efficiency
80
Forced-cooled
80%
75%
Efficiency
70
85%
80%
70%
95%
60
Load (%)
100%
75%
85%
100%
10
90%
Forced-cooled
Efficiency
Efficiency
Convecon-cooled
90%
70%
50
95%
75%
100%
90%
40
Load (%)
80%
95%
70%
30
Convecon-cooled
Load (%)
85%
70%
20
75%
90%
100%
10
80%
95%
70%
95%
230VAC input
90%
Figure
2
85%
UCP225PS12-A
75%
100%
115VAC input
80%
70%
95%
80%
70%
Forced-cooled
75%
100%
100%
Efficiency
vs Load
95%
90%
Figure
1
85%
UCP225PS12
Convecon-cooled
85%
Forced-cooled >150W
Non-condensing
ITE/Medical
3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27
Shock
75%
Vibration
70%
10
Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
20
30
40
50
60
70
80
90
100
Load (%)
4
UCP225 Series
AC-DC POWER SUPPLIES
Applications Notes
Temperature Derating Curves
225
0
-40
-20
0
0
-40
-20
0+50
+70
+50
0
-25
+70
Ambient TemperatureAmbient
(ºC)
Temperature (ºC)
-20
Output Load (W)
112
225
Some specificaon
parameters may not be met
Output Load (W)
75
Some specificaon
parameters may not be met
75
Output Load (W)
150
Some specificaon
parameters may not be met
Output Load (W)
150
Figure 6
225W Forced Cooled
112
0
0
-25
Some specificaon
parameters may not be met
Figure 5
150W Convection Cooled
-20
0+50
+70
+50
+70
Ambient TemperatureAmbient
(ºC)
Temperature (ºC)
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Conditions
Conducted
EN55011/32
Class B
Radiated
EN55011/32
Class A
Class B with King Core ferrites: Output cable: KCF-130-B,
Input cable for 150W load: K5B RC 14x28.5x7-M for all models with
additional KCF-130-B on 48V version. Input cable for 225W load: K5B
RC 14x28.5x7-M plus KCF-130-B.
Harmonic Current
EN61000-3-2
Class A
Meets Class C for loads above 145W
Voltage Functions
EN61000-3-3
Specifications subject to change without notice.
5
UCP225 Series
AC-DC POWER SUPPLIES
EMC: Immunity
Phenomenon
Medical Device EMC
Standard
Test Level
Criteria
IEC60601-1-2
Ed.4.0
as below
EN61204-3
High severity level
as below
ESD
EN61000-4-2
4
A
Radiated
EN61000-4-3
3
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
3
A
Magnetic Fields
EN61000-4-8
4
A
Dip >95% (0VAC), 8.3ms
A
EN55035
(100VAC)
Dip 30% (70VAC), 416ms
A
Dip >95% (0VAC), 4160ms
B
Dip >95% (0VAC), 10.0ms
A
Low Voltage PSU EMC
EN55035
(240VAC)
Dips and Interruptions
EN60601-1-2
(100VAC)
EN60601-1-2
(240VAC)
Notes & Conditions
±8kV contact, ±15kV air
Dip 30% (168VAC), 500ms
A
Dip >95% (0VAC), 5000ms
B
Dip 100% (0VAC), 10.0ms
A
Dip 100% (0VAC), 20ms
B
Performance criteria A