ACDC
20/40 Watts
VEH Series
xppower.com
•
Energy Efficiency Level V
•
CEC 2008 and EISA 2007 Compliant
•
Optional Inlet Connectors
•
Class II Versions
•
+60 °C Operating Temperature
•
Compact Dimensions
•
Low Cost
B R A N D
Specification
Input
• 90-264 VAC
• 47-63 Hz
• 0.5 A max VEH20
1.0 A max VEH40
Inrush Current
• 45 A/90 A for 115 VAC/230 VAC,
cold start at 25 °C
Earth Leakage Current • 0.75 mA at 240 VAC/50 Hz
Power Factor
• EN61000-3-2, Class A
Input Protection
• Internal fuse fitted in line
VEH20: T1 A, 250 V
VEH40: T3.15 A, 250 V
No Load Input Power • 250 kHrs to MIL-HDBK-217F at 25 °C,GB
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Storage Temperature • -40 °C to +85 °C
Cooling
• Convection-cooled
Operating Humidity
• 5-95% RH, non-condensing
Operating Altitude
• 2000 m
Shock
• 10 g, 10 ms on 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
•
•
•
•
•
•
•
Conducted Immunity
Magnetic Field
Dips & Interruptions
•
•
•
Safety Approvals
•
EN55022 level B conducted & radiated
EN61000-3-2 class A
EN61000-3-3
EN61000-4-2 level 3 Perf criteria A
EN61000-4-3 3 V/m Perf criteria A
EN61000-4-4 level 2 Perf criteria A
EN61000-4-5 installation class 3
Perf criteria A
EN61000-4-6 level 2 Perf criteria A
EN61000-4-8 1 A/m Perf criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
EN60950-1, UL/cUL60950-1,
Approved as Limited Power Source
Max Output Power
15
20
20
20
20
20
25
40
40
40
40
40
Output Voltage(1)
W
W
W
W
W
W
W
W
W
W
W
W
5.0
12.0
15.0
18.0
24.0
48.0
5.0
12.0
15.0
18.0
24.0
48.0
Output Current
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
3.00
1.67
1.33
1.11
0.83
0.42
5.00
3.33
2.67
2.22
1.67
0.83
A
A
A
A
A
A
A
A
A
A
A
A
Total Regulation(2)
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
Model Number
VEH20US05(3,4)
VEH20US12(3,4)
VEH20US15(3,4)
VEH20US18(3,4)
VEH20US24(3,4)
VEH20US48(3,4)
VEH40US05
VEH40US12
VEH40US15
VEH40US18
VEH40US24
VEH40US48
Notes
1.
2.
3.
4.
Other output voltages available, contact sales for details
Total regulation includes line regulation and load regulation.
Standard input connector is IEC320-C14 inlet. For optional IEC320-C6 inlet add suffix ‘C6’ to model number, e.g. VEH20US12C6.
For optional class II version with IEC320-C8 inlet add suffix ’C2’ to model number e.g. VEH20US12C2
Mechanical Details
VEH20
1.22 (31.0)
1.22 (31.0)
0.02
(0.5)
0.02
(0.5)
3.90 (99.0) For C8 and C6 inlet versions
4.11 (104.0) for C14 inlet versions
1.22 (31.0)
1.65 (42.0)
0.02
(0.5)
AC INPUT
IEC-320-C14 INLET
AC INPUT
IEC320-C8 INLET
(Optional C2 Version)
AC INPUT
IEC320-C6 INLET
(Optional C6 Version)
VEH40
4.21 (107.0)
1.19 (30.1)
1.85 (47.0)
0.02 (0.5)
AC INPUT
IEC320-C14 INLET
Notes
1.
2.
3.
4.
5.
6.
7.
All dimensions are shown in inches (mm). Tolerance ±0.04 (±1.0) max.
Weight: 0.37 lbs (170 g) for VEH20, 0.62 lbs (280 g) for VEH40
Output connector: is 0.22 (5.5) outer diameter barrel, 0.10 (2.5) inner diameter barrel with center positive (+) and outer shell negative (-). Length is 0.433 (11.0).
Output cable length is 48” (1220mm) approx.
For European mains lead order part: EU-MAINS-IEC, for IEC320-C14 inlet, EU-MAINS-C5 for IEC320-C6 inlet, EU-MAINS-8 for Class II
For UK mains lead order part: UK-MAINS-IEC, for IEC320-C14 inlet, UK-MAINS-C5 for IEC320-C6 inlet, UK-MAINS-8 for Class II
For US mains lead order part: US-MAINS-IEC, for IEC320-C14 inlet, US-MAINS-C5 for IEC320-C6 inlet, US-MAINS-8 for Class II
02-May-14
ACDC
VEH20/40
Models and Ratings
很抱歉,暂时无法提供与“VEH40US18”相匹配的价格&库存,您可以联系我们找货