VES90 Series
AC-DC Power Supplies
XP Power
90 Watts
• Energy Efficiency Level VI
• European CoC Tier 2
• High Power Density
• Single Outputs from 12 V to 48 V
• 100
kHrs
0.82 (370)
lb (g)
MIL-HDBK-217F at 25 °C GB
Efficiency Curves
VES90PS12
100%
Efficiency
90%
80%
115Vac
230Vac
70%
60%
50%
10
20
30
40
50
60
70
80
90
100
Load (%)
VES90PS24
100%
Efficiency
90%
80%
115Vac
230Vac
70%
60%
50%
10
20
30
40
50
60
70
80
90
100
Load (%)
EMC: Emissions
Phenomenon
Emissions
Harmonic Current
Voltage Flicker
Standard
EN55032
EN61000-3-2
EN61000-3-3
Test Level
Level B
Class A
www.xppower.com
Notes & Conditions
Conducted & Radiated
3
VES90 Series
AC-DC Power Supplies
XP Power
EMC: Immunity
Phenomenon
Standard
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Dips and Interruptions
EN61000-4-11
Test Level
Criteria
±15 kV Air, ±8 kV contact
3 V/m
2
Installation Class 3
3V
3 A/m
Dip: 30% 500 ms
Dip: 60% 200 ms
Dip: 100% 5000 ms
Int: 100% 10 ms
A
A
A
A
A
A
A/B
A/B
B
A
Notes & Conditions
High Line/Low Line
High Line/Low Line
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
UL
UL60950-1, UL62368-1
TUV
EN60950-1, EN62368-1
CB
IEC60950-1, IEC62368-1
CCC
China Compulsory Certification, GB4943
AU/NZ
AU/NZ 60950.1
CE
Meets all applicable directives
UKCA
Meets all applicable legislation
Mechanical Details
5.47 (139.0)
47.24 ±0.79 (1200 ±20)
2.28
(58.0)
1 3
2
4
LED Indicator
1.22
(31.0)
IEC320-C14
Rating Label
Pin
1
2
3
4
Function
Output +
Output +
Return
Return
Shell
Connected to output
return and input ground
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
2. Output connector: Power Mini DIN, mates with Kycon KPJX-4S or equivalent.
3. Weight: 0.82 lbs (370 g) approx.
www.xppower.com
28 Oct 2021
很抱歉,暂时无法提供与“VES90PS24”相匹配的价格&库存,您可以联系我们找货