Contact number & arrangement Contact material Voltage Max. switching voltage AC/DC Min. switching voltage Current Rated load
• WT - standard plug-in version with indicating flag and manual testing/latching lever • Miniature size • Cadmium - free contacts available • Coil AC and DC • Plug-in version - rail mount TH35, EN 50022 • Plug-in, solder, PCB versions available • General purpose relays 2C/O AgCdO, AgNi, AgNi/Au 0,2 µm, AgNi/Au 5 µm 250 V / 250 V 5 V (AgCdO) 5 V (AgNi, AgNi/Au 0,2 µm, AgNi/Au 5 µm) AC1 DC1 12 A / 250 V AC - plug-in version 10 A / 250 V AC - PCB version 12 A / 24 V DC - plug-in version 10 A / 250 V DC - PCB version 5 mA (AgNi, AgNi/Au 0,2 µm); 50 mA (AgCdO) 1 mA (AgNi/Au 5 µm) 24 A 12 A - plug-in version 10 A - PCB version 3 000 VA - plug-in version 2 500 VA - PCB version 0,1 W (AgNi/Au 5 µm); 0,3 W (AgNi, AgNi/Au 0,2 µm) 0,5 W (AgCdO) £ 100 mW at 100 mA, 24 V 1 200 cycles/hour 18 000 cycles/hour
Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Resistance Max. operating frequency • at rated load • no load AC1
AC1
Coil
Voltage Rated voltage Must release voltage Operating range of supply voltage Rated power consumption 5...220 V DC 6...240 V AC 50 Hz ³ 0,1 Un DC; ³ 0,2 Un AC see Tables 1, 2 0,9 W DC; 1,6 VA AC C250 250 V AC 2 500 V AC 1 500 V AC 2 500 V AC
³ 2,5 mm ³ 4 mm
Insulation
Insulation category Voltage Insulation rated voltage Dielectric strength • coil-contact • contact-contact • pole-pole Contact-coil distance • clearance • creepage
General data
Operating time (typical value) Release time (typical value) Electrical life • resistive • cos j Mechanical life (cycles) Dimensions (L x W x H) 10 ms AC; 13 ms DC 8 ms AC; 3 ms DC at 12 A, 250 V AC ³ 10 5 see Fig. 2 ³ 2 x10 7 27,5 x 21,2 x 35,6 mm - plug-in standard version (WT) 27,5 x 21,2 x 33 mm - PCB version and version with threaded bolt 35 g -40...+85 °C AC: -40...+55 °C; DC: -40...+70 °C IP 40 10 g (NO); 5 g (NC) 5g for 10...150 Hz max. 270 °C max. 5 s B, cUL, UL, VDE, GOST
Weight Ambient temperature • storing • operating Cover protection category Shock resistance Vibration resistance Solder bath temperature Soldering time Approvals
2
R2
Miniature plug-in power relays
Table 1
Rated voltage V DC
5 6 12 24 48 60 80 110 125 220
Coil data - DC version
Coil resistance (±10%) at 20 °C W
28 40 160 640 2 600 4 000 7 100 13 600 16 000 54 000
Coil code
1005 1006 1012 1024 1048 1060 1080 1110 1125 1220
Coil operating range V DC min. (at 20 °C)
4,0 4,8 9,6 19,2 38,4 48,0 64,0 88,0 100,0 176,0
max. (at 55 °C)
5,5 6,6 13,2 26,4 52,8 66,0 88,0 121,0 137,5 242,0
Coil data - AC 50 Hz version
Coil operating range V AC
Table 2
min. (at 20 °C)
3006 3012 3024 3042 3048 3060 3080 3110 3120 3127 3220 3230 6 12 24 42 48 60 80 110 120 127 220 230/240 12 50 190 565 785 1 240 2 190 3 880 4 150 4 940 16 300 17 400 4,8 9,6 19,2 33,6 38,4 48,0 64,0 88,0 96,0 101,6 176,0 184,0
max. (at 55 °C)
6,6 13,2 26,4 46,2 52,8 66,0 88,0 121,0 132,0 139,0 242,0 253,0
Electrical life at AC resistive load
Fig. 1
Electrical life reduction factor at AC inductive load
Fig. 2
1 0,8
F
Reduction factor
0,6
0,4
1 0,8
0,6
0,4
Power factor
0,2
cosj
3
R2
Maximum DC resistive load breaking capacity
50
Miniature plug-in power relays
Connections diagram (pin side view)
3
Fig. 3
12 (1)
42 (4)
12 10
14 (5) 11 (9)
44 (8) 41 (12)
5 2
A1 (13)
1 0,5
A2 (14)
Terminal (pin) mm
12(1); 42(4); 14(5); 44(8); 11(9); 41(12); A1(13); A2(14) 0,5 x 1,0 for relays f 1,3 mm ± 0,1 for sockets f 1,5 mm ± 0,1
0,1 10
Drilling hole
20 30 40 50 100 200 300
Dimensions - plug-in version (WT), with manual testing/latching lever
Dimensions - version with threaded bolt (without WT)
21,1 21,2 27,4 27,5
6,2 6,3 6,3 4,1 27,5
35,6
6,5
6,6 6,6 21,2
M2,5
6,8
Dimensions - version with cover equipped with mounting flange (without WT)
Dimensions - PCB version (without WT)
43 38
3,5
8
28,4
22
2
6,5
33
6,3 6,5
6
33
4
R2
Mounting
Miniature plug-in power relays
Relays R2 are designed for: • screw terminals sockets GZT2 (modules and clips available) and GZR2 - for DIN rail mounting, • PCB terminals sockets SU4/2D - for PCB mounting,, • solder terminals sockets SU4/2L and G4/2, • direct PCB mounting.
Ordering codes
10 - AgCdO 20 - AgNi 21 AgNi/Au 0,2 µm 23 - AgNi/Au 5 µm
See Tables 1, 2, page 2
2C/O
*
- - -- LDLD WT WTL WTD WTLD no additional features LED indicator arc suppressing diode LED indicator +arc suppressing diode indicating flag + manual testing/latching lever (standard) indicating flag + manual testing/latching lever + LED indicator indicating flag + manual testing/latching lever + arc suppressing diode indicating flag + manual testing/latching lever + LED indicator + arc suppressing diode
* D, LD, WTD, WTLD - only for DC coils WT - standard features plug-in power relays
2002-12-20